Customer Engineering 
Instruction— Reference 




rii 



sing 



ystem Fundamentals 
100 Central Processing I 
1 Console Control Unit 
ultiplexor 




Customer Engineering Instruction-Reference 



7090 Data Processing System 

System Fundamentals 
7100 Central Processing Unit 
7151 Console Control Unit 
7606 Multiplexor 



CONTENTS 



1.0.00 INTRODUCTION TO THE IBM 7090 






5.3.03 Fixed-Point Arithmetic Instructions 


55 


DATA PROCESSING SYSTEM 


5 




5.3.04 Floating-Point Arithmetic Instructions . 


68 


1.1.00 General System Operation . 


5 




5.3.05 Transfer Instructions 


91 


1. 2. 00 Functional Parts of a Computer System 


5 




5.3.06 Trap Mode Instructions 


97 


1.3.00 7090 System Make-up . 


6 




5.3.07 Skip Instructions . . . . 


99 


1.4.00 7090 General Logic . . . . 


9 




5. 3. 08 Control Instructions 


107 


1.4.01 The Stored Program 


10 




5. 3. 09 Sense Indicator Instructions 


111 


1.4.02 Exercises . . . . 


10 




5.3.10 Index Transmission Instructions 


119 








5.3.11 AND and OR Instructions 


128 


2.0.00 COMPUTER OPERATIONS . 


12 




5.3.12 Convert Instructions 


132 


2.1.00 Storage Word Designation 


12 




5. 3. 13 Floating-Point Trap 


141 


2.2.00 The 7090 Word 


12 








2.2.01 Numeric Quantity (Data) Word 


12 


6. 


0.00 IBM 7151 CONSOLE CONTROL UNIT 


144 


2. 2. 02 CPU Instruction Word 


12 


6. 


1.00 Operator's Panel . . . . 


146 


2.2.03 Data Channel Command Word 


14 




6.1.01 Indicators . . . . . 


146 


2.3.00 Fundamental Components 


14 




6.1.02 Manual Controls . . . . 


149 


2.4.00 A+B=C, Print C . . . . 


17 




6.1.03 Manual Control Keys 


151 


2.5.00 Other Components, Instructions and 




6. 


2.00 Customer Engineer's Test Panel 


158 


Commands . . . . . 


21 




6.2.01 Indicators . . . . . 


158 








6.2.02 Switches . . . . . 


162 


3.0.00 CPU INTERNAL FUNCTIONS 


23 


6. 3. 00 Marginal Check Panel 


165 


3.1.00 Functional Components 


23 








3.1.01 Storage Register (SR) 


28 


7.0.00 REFERENCE INFORMATION 


166 


3.1.02 Accumulator Register (AC) 


28 


7. 


1.00 Condensed Logic . . . . 


166 


3.1.03 Multiplier-Quotient Register (MQ) 


28 




7.1.01 Adders ...... 


166 


3.1.04 Sense Indicator Register (SI) 


28 




7.1.02 Address Register . . . . 


166 


3.1.05 Index Registers (XR) 


28 




7.1.03 Program Register . . . . 


166 


3.1.06 Program Register (PR) 


29 




7.1.04 Sense Indicators . . . . 


166 


3.1.07 Shift Counter (SC) . . . . 


29 




7.1.05 Shift Counter 


168 


3.1.08 Program Counter (PC) 


30 




7.1.06 Program Counter . . . . 


168 


3.1.09 Address Register (AR) 


32 




7. 1. 07 Accumulator ..... 


168 


3.1.10 Address Switches (AS) 


32 




7.1.08 Multiplier Quotient . . . . 


168 


' 3.1.11 Tag Registers . . . . . 


32 




7.1.09 Index Registers . . . . 


170 


3. 1. 12 Adders (AD) 


32 




7.1.10 Storage Register . . . . 


170 


3. 2. 00 Instruction Decoding and Processing 


36 


7. 


2. 00 Service Aids ..... 


170 


3.2.01 Operation Decoders 


36 




7.2.01 One Card Programs 


170 


3.2.02 Control Circuits ... 


36 




7.2.02 Voltage 


174 


3.2.03 Pulses ...... 


36 




7.2.03 Adjustment of C Pulse Set 


174 


3.3.00 Basic Cycle 


36 


7. 


3.00 Operator's Panel . 


176 








7. 3. 01 Console Indicators .... 


176 


4. 0. 00 IBM 7606 MULTIPLEXOR 


38 




7. 3. 02 Indicator Lights .... 


177 


4.1.00 Multiplexor Functional Units 


38 




7. 3. 03 Unitized Assembly Lights & Keys 


178 


4.1.01 Multiplexor Clock . 


38 




7.3.04 Switches and Keys . . . . 


178 


4.1.02 Multiplexor Storage Bus 


41 




7.3.05 Plastic Rocker . . . . 


178 


4.1.03 Multiplexor Storage Bus OR' ing . 


43 




7. 3. 06 Reset Motor ..... 


178 


4.1.04 Multiplexor Address Switches 


43 


7. 


4. 00 CE Panel ...... 


179 


4. 2. 00 Data Flow and Control .... 


43 




7.4.01 Indicator Lights . . . . 


179 


4.2.01 CPU to Core Storage . 


43 




7.4.02 Switches and Receptacles 


179 


4.2.02 Core Storage to CPU . 


44 


7. 


5.00 Marginal Check Panel 


180 








7. 5. 01 MC Switches ..... 


180 


5. 0. 00 CPU DATA FLOW AND TIMING 


45 




7. 5.02 MC Meters ..... 


180 


5.1.00 I Cycle 


45 


7. 


6.00 Tailgate ...... 


181 


5.2.00 Indirect Addressing . . . . 


45 




7.6.01 Signal Connectors ... 


181 


5.3.00 Instructions . . . . . 


47 




7.6.02 Power Connectors . . . . 


181 


5. 3. 01 Word Transmission Instructions 


47 






183 


5. 3. 02 Shifting Instructions .... 


53 


APPENDIX 



IBM 7090 DATA PROCESSING SYSTEM 



MAJOR REVISION--September, 1961 

This edition, Form 223-6895-1, obsoletes Form 223-6895 
and all earlier editions. This edition has been revised 
throughout and should be reviewed completely. 



Address comments concerning this manual to: 
IBM Corporation 
CE Manuals, Department 296 
P.O. Box 390 
Poughkeepsie, New York 

©1961 by International Business Machines Corporation 
Printed in U.S.A. 



Console 
Entry Keys 



J 

Indicators 



35 



Prog 
Reg 


Shift 
Ctr 


Sl-9 


10-17 



Program 
Counter 



17 



1 



35 



Storage 
Register 
Q S 17|18 35 



Address 
Switch 



L_f 



r 



Tag 
Register 



18. 19. 20 



-L2 ,. 
t_J~f 



Adders 
QP1-17I18 35 



Index 
Reg A,B,C 



Address 
Register 



17 



Accumulator 



SQP1 35 



MQ 



35 



CORE STORAGE 



Y Driver 
Gote 



Mem Adr 
Register 



Kegister 
314-10111-17" 



Drvr for 
128YLine 



X Driver 
Gate 



72 Sense 
Amps 



72 

Planes 
128 x 128 



72 Pos 
Data Reg 



Dvrs for 
H 28 X Lines! 



Drvr for 
288 Z Line 



Z Driver 
Gates 



Storage 
Bus OR'ing 



SI 



35 



Multiplexor 
Storage Bus 



S1-2Q21-35 



TCH or IA Command 



Che 



A-D 



Channel 
Bus 



E-H 
J7o Data 
Channels 



Add 


ress 


Switch 


3 


17 



E-H 



CARD MACHINES 



721 Card 
Punch 



716 
Printer 



Channel 
^dr SW 



17 



Channel 
SB SW 



SI 



35 



Location 
Counter 



17 



711 

Card 

Reader 



Calc 
Exit 



35 



Channel 
Adr Ctr 



17 



Word 
Counter 



17 



Operation 
Register 



SI, 2, 19 



Calc 
Entry 



35 





Data 






Register 




SI 35 



Entry 




Keys 




Sl-2Chl- 


35 



Location 




Channel 




Tape 




Ctr SW 




Input SW 




Register 




3 17 




SI 35 




SI 35 



R-W Register 




7 Pos 




1 


2,4,8AB 


C 



Skew Reg 
A & B 



Write 
Triggers 



Channels B-D 



Write 
Head 



Pre Amps 

rzz 



Read 
Head 



CENTRAL PROCESSING UNIT 



MULTIPLEXOR 



DATA CHANNEL A 



TAPE UNIT 



FIGURE 2.5-2. 7090 SYSTEM COMPONENTS — REGISTERS, SWITCHING FUNCTIONS, AND DATA PATHS 



1.0.00 INTRODUCTION TO THE IBM 7090 DATA PROCESSING SYSTEM 



The IBM 7090 Data Processing System is a solid-state digital computer that is approx- 
imately six times faster than its vacuum tube predecessor, the IBM 709. Along with 
increased speed, the 7090 is also mbre versatile. It can perform more than 200 distinct 
operations. 

The 7090 is used in such fields as airplane, rocket, and missile design, atomic 
research, weather, and missile tracking. Using this computer, calculations in these 
fields can be done in much more detail and with greater accuracy than ever before. 
Much of the need for experimental testing is also eliminated; rapid, detailed calcula- 
tions during design can foresee many troubles that formerly would be indicated only by 
testing an assembly. 

The IBM 7090 is also advantageous and economically feasible for business paper 
work such as payroll, billing, and sales analysis. Management, with the aid of such 
a computer, can base business decisions on more up-to-date information than was ever 
before possible. 

1.1.00 GENERAL SYSTEM OPERATION 

A computer system may be made to add, subtract, multiply or divide. According 
to its make-up, a system may also print, read cards, punch cards, read or write mag- 
netic tape, or perform many logic operations. Shifting numbers right or left, setting 
the algebraic sign, and comparing the size of two numbers are examples of logic oper- 
ations. 

To solve a problem, a sequence of arithmetic and logic operations and the required 
data are needed. A computer does one operation at a time. When one operation is 
complete, the next one in sequence begins. Executing operations continues until the 
sequence has run its course and the final answer to the problem has been computed. 
The sequence of operations for solving a problem is called a program. 

1. 2. 00 FUNCTIONAL PARTS OF A COMPUTER SYSTEM 

The normal make-up of a computer system consists of five functional parts: 

1. Input 4. Control of all sections 

2. Storage for data and instructions 5. Output 

3. Arithmetic for actual computing 

These parts work together to accept data and instructions into the system, compute 
the solution to the problem, and send the solution back out of the system. This all takes 
place under the direction of the program. 



5 



The input section of a computer system accepts information from any outside source 
and places it in the storage section. This information may come from punched cards, 
magnetic tape, or manually operated keys. The information may be instructions, data 
(numbers for arithmetic calculations), or alphabetic characters for printing page 
headings, comments, and so forth. 

The storage unit accepts and stores information that comes into the system through 
the input section. When any portion of the information in storage is needed, that por- 
tion is located and sent out to the section that requested it. All information in the sys- 
tem is at one time or another, in storage; therefore, computer speed depends on 
storage speed. The storage scheme of most computer systems today is random access — 
any portion of information can be located directly without searching other locations. 

The arithmetic section is the calculating section of the computer system. Here, 
portions of information > either instructions or data, can be transformed, combined, 
or altered. 

The control section directs the other sections. It tells them what to do and when to 
do it. Instructions come into the control section from storage. The control section 
also controls itself in that it keeps account of the instruction it is using and the one that 
it will use next. 

The output section takes calculated information from storage and presents it to an 
outside user. Commonly used forms of output are: information on magnetic tape, 
punched cards, printed reports, or indicator lights. 

1.3.00 7090 SYSTEM MAKE-UP 

The 7090 system includes all five of the sections previously mentioned. Figure 
1.3-1 shows the general grouping of these sections in the 7090 system; arrows indicate 
the general flow of information. Although the functional sections can be neatly separ- 
ated, in practical application it is more likely that some will be combined and others 
separated. Input and output are combined with a portion of control in a data channel, 
and arithmetic with another portion of control in the central processing unit (CPU). 
Storage is the only functional section that is a separate machine unit. The multiplexor 
controls the routing of information into and out of storage. 

The arrangement shown in Figure 1.3-1 allows input-output to operate somewhat 
independently, sharing storage with CPU. The highest order of controls is in the CPU, 
where control is delegated to the lower order controls in the data channel and multi- 
plexor. 

A representative 7090 system appears in Figure 1. 3-2; the physical grouping of 
7090 functions is shown, with machine types. The IBM 7100 Central Processing Unit 
is contained in two cabinets, or frames, CPU1 and CPU2. The 7151 Console Control 
Unit provides manual controls for the system operated as a whole. The IBM 7606 
Multiplexor and IBM 7302 Core Storage correspond to the same units shown in Figure 
1.3-1. The number of machines available for 7090 input-output (I-O) operations is 
variable, but only seven types are ordinarily used: 



6 



CPU 



Control 
and 
Arithmetic 



Multiplexor 



Control 



Data Channel 




Input - Output 
and 
Control 



Storage 



FIGURE 1 .3-1 . 7090 SYSTEM FUNCTIONAL ARRANGEMENT 



Up to Ten 729 ll's or IV's per Data Channel 



7607 
Data 
Chan 
I 



7607 
Data 
Chan 
II 



7607 



7100 
CPU 
I 



7607 



7100 
CPU 
2 



n 



7607 



7606 
Multi- 
plexor 



7607 
II 



7302 
Core 
Stor 



7607 



7607 
II 



7151 
Console 



721 
Card Punch 



711 
Card 
Reader 



716 1 



Printer 
I 




60^,208v 



PCU 



Power (400 208v, 30) to All Frames 



FIGURE 1 .3-2. BLOCK REPRESENTATION OF 7090 SYSTEM 





(D 






Card 














Data 








CPU 




MPX 




Channel 




Reader 




CPU 



















Storage 



Data 
Channe 



CPU 




-Data 
^Channel 




MPX ✓ 


■ — - 



Storage 



Storage 



Printer 



Run Card Reader and Read A and B 



Add A and B, Store Sum C 



Start the Printer and Print C 



FIGURE 1.4-1. ADD A AND B, PRINT C 
7 



7607 Data Channel Model 1 
716 Printer 
721 Card Punch 



7607 Data Channel Model 2 
729 II Magnetic Tape Unit 
729 IV Magnetic Tape Unit 



711 Card Reader 

The reader, punch, and printer can be used only with the 7607 Data Channel Model 1. 
The 729 II and 729 rv tape units can be intermixed on either model data channel. 

The IBM 7100 CPU is the control center of the 7090 system. In addition, all arith- 
metic and logic circuits are located in the CPU. The CPU receives information from 
storage, decodes it, and performs the necessary operation. Even though 1-0 is an 
independently functioning section, its operation must be initiated from the CPU. 

The IBM 729 II and 729 IV Magnetic Tape Units write information on magnetic tape 
or read information from magnetic tape. The two models perform indentical functions, 
but the 729 IV moves tape at a higher rate than the 729 II. 

The IBM 711 Card Reader reads information from punched cards at 250 cards per 
minute. 

The IBM 716 Printer prints information from core storage at 150 lines per minute. 
The typewheel echo pulses are available to the 7090 system, where they may or may 
not be used to check the accuracy of printing. 

The IBM 721 Card Punch punches information from core storage at 100 cards per 
minute. 

The IBM 7607 Data Channel Models 1 and 2 control the flow of information between 
the I-O units and core storage. A 7607 Model 1 can control any combination of ten 
729 II and 729 IV tape units and up to one each of reader, punch, and printer. The 
printer must be present if either a reader or punch are to be used. A 7607 Model 2 
can control ten tape units, but neither card machines nor printer. The 7090 system 
may include up to eight data channels. 

Each data channel can be regarded as a subsystem, with its own manual control 
console and indicator panel. Once a data channel is set in operation by an instruction 
in the CPU program, it can call in its own instructions (called commands in channel 
operations). These commands make up what is known as an I-O program. This pro- 
gram controls the operation of the I-O unit that is selected and also provides informa- 
tion to or receives information from that I-O unit. Information received from an I-O 
unit is placed in core storage, or information is taken from core storage to be supplied 
to a selected I-O unit. 

The CPU handles instructions that select a particular data channel and the I-O device 
on that channel. The CPU is also responsible for supplying the channel with its first 
command. This first command can be the first of a series of commands (I-O program) 
that will sustain the selected channel and device in operation independently of the CPU. 
When this I-O program has run its course, the selected device stops and the operation 
is complete. 



8 



It is possible for a 7090 with the full eight data channels to have eight 1-0 programs 
and the CPU program in operation simultaneously — each independent of the others and 
all sharing core storage. 

The IBM 7302 Core Storage is a fast, random-access storage unit. A unit of informa- 
tion can be read into (or out of) any one of its 32,768 storage locations in 2.18 micro- 
seconds. Read-out is spoken of as being nondestructive in that the information remains 
intact in core storage after read-out.' Storage serves both the CPU and data channels. 
The only restriction is that no two units can be using storage at exactly the same time. 
If a data channel calls for storage while CPU is using storage, the channel waits until 
CPU permits storage priority to pass to the channel. 

The IBM 7606 Multiplexor is a time sharing and switching device. It provides a path 
to and from storage for the CPU and data channels. The multiplexor also performs 
certain anticipatory, or look-ahead functions associated with data channel operations. 

The IBM 7151 CPU Console Control Unit provides the means to manually control the 
system and to display, in indicator lights, the contents of various registers, or any one 
of the storage locations. Several registers are continually displayed. The console also 
houses the CE test panel and the marginal voltage check panel. 

1.4. 00 7090 GENERAL LOGIC 

The 7090 system operation can be compared to a 407-514 summary punch operation. 
The card feed in the 407 is input; storage, arithmetic, and control are in the 407; the 
407 print wheels and 514 punch are output. The 514 punches a card only when instructed 
to do so by the 407 and information to be punched must be in storage and wired to the 514. 
The 407 waits for a signal from the 514 before proceeding to another operation. Similar 
requirements for control exist in the 7090 system. Input waits in a ready status until 
called for by the control section; the control section manipulates information in a pre- 
determined manner and sequence; output operates when called for by the control section. 
Again — as in the accounting machine, summary punch system — the control section is 
continually informed of the progress of events in all sections so that another operation 
can be initiated as soon as the current operation is complete. 

An example of information flow and control in the 7090, is the sequence taken by the 
system in solving the following problem: 

Given: The quantities A and B punched in a card. 
Problem: Add B to A and print the result, C. 

(A+B = C, print C) 

1. Cause the card reader to run and feed the card. 

2. Read the information from the card and place it in storage. 

3. Bring A from storage into the arithmetic section. 

4. Bring B from storage and add it to A. 

5. Place the result, C, in storage. 

6. Cause the printer to run. 

7. Bring C from storage and send it to the print wheels for printing. 



9 



The program for this problem is made up of instructions and data channel commands 
that control the 7090 to perform the operations outlined. These instructions and com- 
mands progress step-by-step and the control section recognizes each in turn when the 
previous operation is complete. 

Because the control section of the system operates at electronic speed and the card 
reader and printer are relatively slow, it is apparent that much communication is nec- 
essary between the mechanical functions and the control section. The control section 
must wait until A and B have been read from the card before adding them together. The 
sum C can be developed and stored at electronic speed, but must wait in storage until 
the printer is ready to receive it for printing. 

Figure 1.4-1 shows the progression of the steps in the foregoing program. Not 
shown in Figure 1.4-1 are the instructions and commands that initiate each of the oper- 
ations depicted. These are also in storage along with the factors A and B and constitute 
the stored program. As each instruction ends its operation, the next instruction is 
called out and initiates its operation. In this manner, the 7090 system progresses 
through the solution according to the program in storage. 

1. 4. 01 The Stored Program 

The program previously described used CPU instructions and data channel commands 
from storage. These instructions controlled other information going to and from stor- 
age. But how did the instructions and commands get into storage? In the beginning, 
the author of the program decides what instructions and commands to use and in what 
order to use them. There are several ways to get these instructions and commands in- 
to storage without a stored program already in the system. Among these ways are 
direct manual entry from the operator's keys on the IBM 7151 Console Control Unit*, 
entry from cards or tape caused by a command manually entered into a data channel 
from the IBM 7617 Data Channel Console*, and forced automatic operation of a card 
reader or tape unit caused by depression of a load key on the CPU console. 

Whatever the means of entry, both the stored program instructions and the data to 
be processed must be previously translated into machine language in the form of binary 
words. A binary word, as used in the 7090, consists of 36 binary positions. The bin- 
ary number system is explained in Appendix A of IBM 7090 Data Processing System 
Reference Manual, Form A22-6528. Also explained there are processes for conversion 
of decimal numbers to binary numbers, and binary numbers to decimal numbers. A 
third system (called octal) provides a quicker and less cumbersome means of expressing 
binary numbers. 

1.4.02 Exercises 

The following equivalent numbers in binary, octal, and decimal provide an opportun- 
ity to practice conversion from one number system to another. Do the conversions and 
check your results against those given. (Decimal and octal fractions are rounded to 
three places and binary fractions are rounded to nine places.) 



* The CPU console (IBM 7151) is a separate machine type, and there is only one on each 7090 system. 
Each 7607 Data Channel has a manual console of its own (IBM 7617). 



10 



Whole Numbers 



1. 5 10 

2. 1125 10 

3. 177 8 

4. 1325 8 

5. 7777 8 

6. 1 101 0102 

7. 1 111 1112 

8. 1 010 101 2 

9. 4096 10 
10. 3333io 

Fractions 

1. 0.7io 

2. 0.25 10 

3. 0.33 10 

4. 0.145 10 

5. 0.915 10 

6. 0.4 8 

7. 0.57 8 

8. 0.715 8 

9. 0.1012 

10. 0. 101 010 2 

Improper Fractions 

1. 17.05io 

2. 40.96 10 

3. 17.05 8 

4. 77.77 8 

5. 11.112 

6. 10.012 



5 8 = 101 2 

2145 g = 10 001 100 101 2 

1 111 111 2 = 127 10 

1 Oil 010 1012 = 72510 

111 111 111 111 2 = 4095io 

152 8 = 106io 

177 8 = 127io 

125 8 = 85io 

10000 8 = 1 000 000 000 000 2 

6405 ft = 110 100 000 1012 



0. 546 8 
0.2 8 
0.251 8 
0. 112 8 
0.724 8 
0. 1 2 

0. 101 111 2 

0. Ill 001 1012 

0.5 8 

0. 52 8 



0.101 100 110 2 
0.012 

0.010 101 001 2 
0.001 001 012 
0. Ill 010 1 2 
0.5io 
0.734io 
0.9 10 
0. 625io 
0. 656io 



21.031 8 

50.753 8 

1 111.000 1012 

111 111 . Ill 111 2 

3.3 8 

2.2 Q 



10 001.000 011 01 2 

101 000.111 101 0112 

15. 078i 0 

63.984i 0 

3.375io 

2.25io 



11 



2. 0. 00 COMPUTER OPERATIONS 



A more detailed study of 7090 operations requires additional information about the sys- 
tem. This section of the manual deals with the designation of each word location in 
storage, the 36-position 7090 binary word, and the fundamental components of system 
logic. Again, these will be applied to the problem, A+B = C, print C. In this descrip- 
tion of the problem, the importance of the central processing unit (CPU) becomes more 
apparent. 

2. 1. 00 STORAGE WORD DESIGNATION 

The storage unit in the 7090 system contains 32,768 locations. Each of these word 
locations is made up of 36 binary positions. Ordinarily, all 36 positions of any one 
word are moved to or from storage at one time. This is known as parallel data trans- 
mission and allows the moving of a large numeric factor each time that storage reads 
in or out. 

Think of storage as a large double square of pigeon-holes as shown in Figure 2. 1-1. 
Each pigeon-hole has the capacity of a full 36-bit word. When a word is to be stored in 
or taken from any location, this location must be designated. Obviously, there must be 
32,768 of these designations, or addresses, one for each location. Because all opera- 
tions in the 7090 system are done in binary notation, there are 15 binary positions used 
for addressing storage locations. Only 15 are required because storage addresses are 
expressed in octal numbers ranging from 00000 to 77777, rather than from 00001 to 
100000. An address of all zeros designates the first word location in storage. Every 
storage operation, whether directed by the CPU or a data channel, must be addressed. 

2. 2. 00 THE 7090 WORD 

A 7090 word may be a numeric quantity, a CPU instruction, or a data channel com- 
mand. In all cases, the word is a full 36 positions. The logic format of a word differs 
according to its use. 

2. 2. 01 Numeric Quantity (Data) Word 

Numbers, usually referred to as data, normally appear in true form in 35 of the 36 
binary positions in the 7090 word. The remaining position is the algebraic sign of the 
number (Figure 2. 2-1). A binary bit, one, in the sign position is a negative sign. No 
binary bit, zero, in the sign position of the word is a positive sign. The sign position 
and the 35 numeric magnitude positions make up the format of the data word. 

2.2.02 C PU Instruction Word 

The CPU instruction word (Figure 2.2-2) has a different logic format. The CPU 
instruction word gains its distinctive format because it is called for by CPU at a time 



12 




2 Sections, 16,384 Word Locations Per Section 
FIGURE 2.1-1. STORAGE LOCATIONS 



— i — i — i — i — i — i — i — i — i — i — i — i — i — i — i — i — i — i — i — I — i — I — i — i — i — i — i — I — I — i — i — i — i — I — 
1 35 
i i i i i i ' i I I i I i i i i i i — i — i — i — i i — i — 



FIGURE 2.2-1. DATA WORD 



Prefix Tag 



1 

s 

1 


1 

2 

1 


I I 

3 

1 1 


I I I I I I I I 

Decrement 

i i i i i i i i 


I I I 

17 

i i i 


I I 

18 20 

i i 


i I 

21 

i i 


i l i I I I I l 

Address 




1 1 1 1 

35 

i I i i 



FIGURE 2.2-2. INSTRUCTION WORD 



Prefix Tag 



1 

s 

1 


1 

2 

1 


1 1 
3 

1 1 


1 1 1 1 1 1 1 1 1 
Word Count 

l 1 1 1 1 1 1 1 1 


1 1 1 
17 

I 1 I 


1 1 
18 20 

l l 


1 1 

21 

1 1 


1 1 1 1 1 1 1 1 

Address 
1 1 1 1 1 1 1 1 


1 1 1 1 

35 
1 1 1 1 



FIGURE 2.2-3. COMMAND WORD 



13 



when one operation is about finished and an instruction is needed. The author of the 
program must provide the proper instruction word in storage and must build his program 
so that the CPU has the address for that instruction when it is needed. 

Each field of the instruction word has its particular significance because the CPU 
brings the word in as an instruction. The sign position is always a part of the operation 
code. Along with the sign, either the remainer of the prefix field or the decrement field 
dictates what operation is to be done. If there is nothing in the remainder of the prefix, 
the sign and decrement contain the operation code. If either of the two remaining posi- 
tions of the prefix contains a bit, the prefix contains the entire operation code and the 
decrement field is used for another purpose. 

The address field usually contains the address of a data word in storage. This data 
word is brought into the CPU as a part of whatever arithmetic or logic function is called 
for by the operation code. Thus, the instruction not only dictates the operation to be 
performed, but also specifies the address of the data to be used. In some instances, the 
address field is a part of the operation code. When this is the case, the address field is 
not used to address data in storage. 

The tag field is a means of causing the CPU to calculate a storage address that is 
different from the address field of the instruction. 

2. 2. 03 Data Channel Command Word 

Similar in format and application to the CPU instruction word, the data channel com- 
mand word gains its special significance by being called out of storage by the control 
function in the data channel. This, as in CPU, occurs when one operation is finished 
and the data channel needs to be directed what to do next. The two major differences 
are that: 

1. The prefix is always the operation code in the data channel. 

2. Positions 3-17 are a word counter. Whether the operation is reading or writing, 
once the command is in channel, the word count becomes one less each time a 
word is handled. Thus, when the word count becomes zero, the channel must 
ask for a new command. 

Data channel operations always start by unit selection from a CPU instruction. 
Independent operation continues on the same unit as long as successive commands re- 
quire it. Once the succession of commands is broken by a command to disconnect, 
that unit and the channel that was operating have completed their assignment. This is 
all planned in advance by the author of the program, and commands are stored where 
the data channel will call for them at the proper time. 

2. 3. 00 FUNDAMENTAL COMPONENTS 

The fundamental components described in this section are the operating features 
(Figure 2. 3-1) used in the operation A+B = C, print C. For the most part, these are 
groups of binary storage positions where information may be placed outside of the stor- 
age unit itself. These groups are commonly called registers. 



14 



S,3— 



Program Reg 



SI 



S — *■ 35 



Storage Register 



•35 



1-^35 
21-K35 



Adde 



QP1 



35 



QP— *35 



Accumulator 



SQP1 



35 



S,l-*~35 



17 



Program 
Counter 



'17 



3—17 



Address 
Register 



-17 



711 
Card Reader 



Multiplexor 
I ' 



S — »-35 



Memo 
Reg 


ry Data 
ister 


S ^35 












Memory Address 
Register 


3 


17 



716 
Printer 



S — *■ 35 



Calculate 


sr Entry 


S 


*- 35 



S »- 35 



Calculator Exit 



■35 



S — ^35 



S — *~ 35 



Data Register 



35 



S — ^35 



21 —35 



Address 
Counter 



17 



3 -*-17 



S 



Word 
Counter 



■17 



Operation 
Register 



S 1 2 



FIGURE 2.3-1 . FUNDAMENTAL SYSTEM COMPONENTS USED IN A + B = C, PRINT C 



15 



Besides performing a temporary storage function, the registers described also offer 
the ability to break the 36-position word into lesser groups. You will see that particu- 
larly the operation code and the address are extracted from the whole instruction word 
and placed in separate registers. You will also see the use of the address field of the 
instruction word as a part of the operation code. 

Note that the descriptions in this section are elementary and only as complete as is 
required for the problem A -KB = C, print C. Other registers and switching functions 
will be described in later sections. 

The calculator entry and calculator exit handle information coming from or going to 
the card machines (reader, punch, or printer). There is no storage here, but informa- 
tion waits at these points until the data register is ready to receive the information from 
calculator entry or the card punch is ready to receive the information from calculator 
exit. 

The data register is the receiving and distributing point for data passing to and from 
the data channel. Data words are received here from input units for forwarding to 
storage. Data words also come from storage to this register for forwarding to output 
units. 

The channel address counter, word counter, and operation register (with the com- 
mand location counter) are the operating controls in the data channel. Because the lo- 
cation counter is not needed in A+B = C, print C, it has been omitted from Figure 2.3-1. 

The channel address counter holds the storage address for the data word being cur- 
rently handled in the data channel. As a register, this counter receives a beginning 
address from the address field of a command coming into a channel. As each word is 
handled, the channel address counter advances one count. Thus, words are stored from 
channel input in consecutive ascending locations in storage. Likewise, words withdrawn 
from storage for output come from consecutive ascending locations. 

The word counter, as a register, receives a word count from a command coming into 
a data channel. As a counter, it is reduced by one each time a word is handled. The 
data channel recognizes zero in the word counter as a signal that the command has been 
completely executed. 

The operation register receives the prefix portion of a command word coming into a 
data channel. This register is decoded to dictate what operation is to be performed. 

The memory address register receives, through the multiplexor, the address of a 
storage word location to be entered or read out. This address may originate in the 
CPU or in the data channel. 

The memory data register receives a word either from a storage location, or 
(through the multiplexor) from the CPU or the data channel. The latter case is for the 
purpose of storing the word at the addressed location; the former is a read-out to the 
CPU or data channel from the addressed location. 



16 



The circuits in the multiplexor are actually switching circuits rather than registers. 
These switching functions allow either the CPU or the data channel to use storage for 
purposes of addressing and data transmission. The multiplexor also signals storage 
whether the operation is to be stored or read out, governed by control from the CPU or 
data channel. 

The storage register accepts a word from storage for use by the CPU, or from the 
CPU for forwarding to the memory data register. This is true for both instructions 
and data. The storage register also plays a part in certain arithmetic and logic opera- 
tions that are not used in A+B = C , print C . 

The address register and program counter are the addressing registers of the CPU. 
The address register, in every CPU operation involving storage, contains the storage 
address. This address is sent to the memory address register when CPU is using stor- 
age. 

The program counter keeps account of the progress of the program. This counter 
normally advances by one after each instruction has been called for. Thus, the normal 
course of events is to call for instructions from ascending addresses in storage. When 
one operation is complete, the current reading in the program counter goes to the ad- 
dress register for forwarding to the memory address register. The author of the pro- 
gram is responsible for having the next instruction stored at this address. 

The adders and accumulator are the main arithmetic components of the entire sys- 
tem. Although the adders are not registers and have no capacity for holding numbers, 
they play such a prominent part in almost every CPU operation that they cannot be con- 
sidered as an ordinary switching circuit. 

The adders perform a merging function, having the capacity for operating on an 
entire word at one time. Numbers from two sources can be added together and carries 
simultaneously added in. Two full words can be sent to the adders, and the complete 
answer can be taken almost immediately to a register. In addition, the adders provide 
the only means of entry to the accumulator and the only direct route from the address 
field of the storage register to the address register. 

The major use of the accumulator is to receive the output of the adders. The name 
accumulator, although not completely appropriate for a noncounting, nonadding register, 
is applicable in that this register receives and holds sums from the adders. 

The program register receives and holds the operation code of each CPU instruction. 
Decoding the configuration of binary bits in the positions of this register establishes the 
controls for the operation to be done. Each time that an operation is ended and a new 
one is to begin, the old operation code is cleared from the program register and the 
new code is set in. Thus, the controls for the operation completed are dropped and the 
controls for the new operation are brought into effect. 

2.4.00 A+B=C, PRINT C 

The following explanation of 7090's operation in performing A+B = C, print C is more 
detailed than the general sequence in Section 1.4.1. Review that section before proceeding. 



17 



Assume that the necessary instructions and commands are in storage before the 
program starts. Figure 2. 4-1 shows the locations and binary bit configurations of the 
words in storage when the program begins. The following discussion follows these 
words sequentially as the program progresses to completion. 

Before starting the program, the card with A and B punched in it is placed in the 
card reader and the card reader start key is depressed. This action causes the card to 
feed down to the reading brushes and the reader to go into ready status. It is now pos- 
sible for the CPU to direct a data channel (let us say channel A) to run the card reader 
and read the card. 

The operation of the CPU starts with the depression of the start key on the CPU 
console. First, the CPU must have an instruction for the very first operation. Storage 
must have an address for this instruction word to locate it for the CPU. The program 
counter (PC), initially zeros, contains this address, which goes to the address register 
(AR) and then to the memory address register (MAR). The word in storage is now lo- 
cated by its address (00000), set into the memory data register (MDR), and sent to the 
storage register (SR). At the same time that this first instruction goes to the SR, the 
operation code goes to the program register (PR) . Because positions 1 and 2 of the 
word contain no bits, S(sign) and 3 through 11 constitute the operation code, going to S 
and 1 through 9 of the PR. 

The function of the PC for the first instruction is finished when the PR receives the 
operation code. It then advances one to 00001 in preparation for calling in the next 
instruction when the first has completed its operation. 

The function of the first instruction is to select the card reader on channel A. De- 
coding PR (S-9) indicates only a read select, so CPU looks to the SR (23-35) for a 
channel and unit selection. Here, the reader on channel A is indicated. Channel A 
acknowledges the selection of its reader if the reader is ready to run, and the CPU is 
free to go on to another instruction. 

The program counter (PC) now reads 00001, so that when the CPU requests a word 
from storage, the second instruction comes to the SR and PR. This occurs in the same 
manner described for the first instruction, and the PC advances to 00002. 

Decoding the new bit configuration in PR (S-9) at this time indicates that the channel 
registers are to be reset and a command is to be received. The CPU has the address 
of the command in SR (21-35), so this address goes through adders 3-17 to the AR and 
MAR. At the same time, PR decoding in the CPU causes the word at this address, 
00012 (Figure 2.4-1), to go to channel A rather than to the CPU. Channel A receives 
the operation code of the word (S, 1, 2) in its operation register, the word count (3-17) 
in its word counter (WC), and the first storage address (21-35) in its channel address 
counter (CAC). 

At this point in the program, all operations have occurred at electronic speed within 
a few microseconds. Channel A has its reader selected for a reading operation, a 
disconnect -type operation code, a word count of two, and a beginning address where the 
first of the two words is to be stored. The reader feeds and reads the card, and channel 
A stores the first word at 00014 according to the CAC. The WC decreases to 1 and the 



18 



S 1 2.3 4 5 6 7 8 9 101112 1 314 15 16171819 20 212223 2425 26 2728 29 303132333435 





|o 


0 


0|1 1 111 1 0;0 1 OjO 0 OlO 0 0 1 0 0 0 1 0 0 OjO 0 ljO 1 1 ; 0 1 0; 0 


0 


ll 


00000- 






K6QQ 06I6CT \_ nonncl A V^QTCt KSQQCr 








|o 


0 


0 1 1 0 ljl 0 ojo o ojo 0 ojo 0 0 1 0 0 0 1 0 0 0 i 0 o ojo o ojo 0 ljo 


1 


o| 


00001- 






Keset* \_nannel A Keojsters ana Lood a Lommond rrom Location UUUI^ 








1° 


0 


0 1 0 0 Oil 1 0;0 o olo o olo 0 0 1 0 0 0 1 0 0 OjO 0 0|0 0 OjO o ojo 


1 


o| 


00002- 






\A/nilp InnnnP A In Cln^rnfrirm Tn w o trio NJovt Inctri i^t-irtrt Frr\m 1 Arntinn 00007 
"IHIC V.llUflflGl AA Id III WfJCIUI IUI1 ^ 1 Ur\C I lie INCAl 1 DM 1 U (- 1 1 ON riOlTl LOLQl IOM \J\J\J\J£. 








|o 


0 


0 1 1 0 1|0 0 0;0 0 0|0 0 0;0 0 0 1 0 0 0 1 0 0 0 • 0 0 0|0 0 OjO 0 ljl 


0 


o| 


00003- 






Clear the AC and Enter the Contents of Location 00014 (A) 








1° 


0 


0 1 1 0 olo 0 0;0 o ojo o ojo 0 0 1 0 0 0 [ o o ojo o ojo 0 ojo 0 ljl 


0 


ll 


00004- 






Add to the Contents of the AC From Location 00015 (B) 








1° 


0 


o|i i ojo o ojo o ljo o ojo o o | o o o | o o olo o ojo o ojo o ljo 


0 


ll 


00005- 






Store the Contents of the AC at Location 0001 1 (C) 






1 


0 


0 


0 j 1 1 ljl 1 Ojl 1 ojo o ojo o o|o o o|o o ojo 0 ljO 1 ljl i ojo 


1 


o| 


00006- 






Write Select Channel A Printer 






1 
1 


o 


0 


o|i o Hi o ojo o ojo o ojo o o|o o o|o o ojo o ojo o ojo o ljo 


1 


1 1 
1 1 


00007- 






Reset Channel A Registers and Load a Command From Location 00013 






1 


0 


0 


0 1 0 0 ojo o ojo o ojo o ojo 0 0 1 0 0 0 1 0 o ojo o ojo o ojo o ojo 


0 


o| 


00010- 




Halt CPU Operation. When Started Again, Take the Next Instruction From Location 00000 




1 










1 


00011- 






This Location is Reserved for C. 






1 


0 


0 


0|0 o ojo 0 olo 0 ojo 0 OjO 1 0 | 0 0 0 | 0 o ojo 0 ojo 0 ojo 0 ljl 


0 




00012- 




Run the Selected I/O Unit for Only Two Words, Starting at Location 00014 (Read A and B) 




I 


0 


0 


o|o o ojo o ojo o ojo o ojo 0 1 1 0 0 0 | o o ojo o ojo o ojo o ijo 


0 


ll 


00013- 






Run the Selected I/O Unit for Only One Word, Located at 00011 (Print C) 







FIGURE 2.4-1 . PROGRAM WORDS FOR A + B = C, PRINT C 



19 



CAC steps to 00015 when the first word, factor A, has been sent to storage. When the 
second word, factor B, is read, the data channel sends it to storage location 00015 as 
indicated by the CAC. The word count now goes to zero as the WC is reduced again. 
With a disconnect operation code, the work of the data channel is done and the CPU is 
notified of this. 

What has CPU been doing during the relatively long period of mechanical operation 
of the card reader ? It cannot be allowed to go on until factors A and B have been read 
in and stored. 

When channel A acknowledged receipt of its command, the CPU sent to storage for 
the word at 00002. The PC to AR to MAR caused the word at 00002 to come from stor- 
age to SR and PR. Decoding the bits in PR sent the CPU to the address in SR (21-35) 
for a new instruction and indicated that nothing more was to be done except that this 
address was also to be put in the PC. This operation was indicated to be conditional, 
however, and was to be done only if channel A was in operation. Channel A was in oper- 
ation, so the following events occurred while channel A read in factors A and B and 
stored them. 

1. PC advanced to 00003. 

2. SR (21-35), through adders 3-17, went to AR and then to MAR, each time being 
00002. 

3. AR contents of 00002 replaced PC contents of 00003. 

4. Storage sent back the same word originally called for as the third instruction. 

5. The same operation code was decoded and the entire operation repeated, so 
long as channel A remained in operation. 

Eventually, channel A completes reading in and storing factors A and B. This time, 
the CPU does not send for 00002 again, but allows the PC to retain 00003 and sends this 
to AR and MAR. Now the word at 00003 comes to SR and PR. Decoding PR causes the 
accumulator to be cleared. The address field, SR (21-35), of the instruction goes 
through adders 3-17 to AR and then to MAR. This time, the CPU is not finished with its 
operation and is not looking for a new instruction. Instead, factor A comes from storage 
location 00014 to the SR. No portion of this word enters the PR and the clear and add 
operation code is retained there. Factor A goes from the SR through the adders to the 
accumulator (AC). There is no offsetting of the address field this time, because the 
SR contains a data word rather than an instruction word. 

With the placement of factor A in the accumulator, the clear and add operation is 
complete, so the CPU sends to storage for a new instruction. The PC has advanced to 
00004, and this address through AR and MAR causes storage to send the contents of 
00004 to SR and PR. Decoding the new operation code in the PR, the CPU sends SR 
(21-35) through adders 3-17 to the AR and MAR. This address of 00015 is the address 
of factor B, which is to be added to the contents of the AC. The PC advances to 00005. 
Storage sends factor B to the SR in the same manner" that it sent factor A previously. 
Here, again, the CPU has not yet completed its operation, and the word is treated as 
a data word. From the SR, factor B goes to the adders. At the same time, factor A 
goes to the adders from the AC, due to the operation code in the PR. The sum of factors 
A and B out of the adders goes to the AC, replacing factor A there. The CPU has now 
completed the add instruction, using the address of factor B. 



20 



The address of 00005 in the PC, through the AR and MAR, brings the next instruction 
to the SR and PR. Decoding the PR, the CPU operation is store and the address — SR 
(21-35)— at which to store is 00011. The PC advances to 00006, Sum C in the AC, be- 
cause of decoding store, goes to the SR after SR (21-35) goes to the AR and MAR. Then 
storage accepts SR to the memory data register (MDR) and stores it at address 00011. 
The operation is now complete and sum C is stored for printing. 

The only remaining task for the CPU is to tell channel A to start the printer and to 
give channel A the address of C. The next instruction, coming from 00006 as dictated 
by the PC, decodes as write select. The PC advances to 00007. Again, as in read select, 
the channel and unit selection is in the address field of the instruction. The bit configura- 
tion there indicates the printer on channel A. Channel A acknowledges the selection if the 
printer is ready. This frees the CPU to ask for another instruction, this time from 00007. 
The instruction, decoded in the PR, directs the resetting of channel A registers and the 
loading of a command from the address found in the address field of the instruction. In 
this case, SR (21-35) has the address of the command. The address goes to adders 3-17, 
then to the AR and MAR. Storage delivers the contents of this address, 00013, to chan- 
nel A instead of the CPU because of controls set up by the PR. 

By this time, the PC had advanced to 00010, so when channel A has received its com- 
mand, the CPU receives the contents of 00010 as an instruction. Decoding a PR of zeros 
causes the CPU to stop. The operation code of zeros is called halt and transfer. If the 
CPU should be restarted, the address field of 00010, which is all zeros, would go to the 
PC and the program would restart at 00000. 

The role of the CPU in A+B = C, print C is now ended. However, channel A still 
has to print C. The printer is started and channel has a disconnect command in the 
operation register, a word count of one, and the address of C — 00011 — in the CAC. 
These all came from storage location 00013 as the CPU executed the instruction at 
00007. Channel sends 00011 from the CAC to the MAR. Sum C comes back to the DR, 
and the WC steps to zero. As soon as the printer is ready to receive C, the word goes 
from the DR to the calculator exit and is printed. Channel A is also finished now, and 
A+B = C, print C has been accomplished. 

If you have followed the program for A+B = C, print C, carefully, referring to 
Figure 2. 3-1, you should now have a general idea of the operation of the 7090 system. 

2. 5. 00 OTHER COMPONENTS, INSTRUCTIONS, AND COMMANDS 

The preceding explanation is simplified, and many components and functions are 
omitted. Before continuing with a study of this manual, study the instructions and com- 
mands described in IBM 7090 Data Processing System Reference Manual, Form 
A22-6528. 

Figure 2. 5-1 shows two other possible configurations of the CPU instruction word: 
Figure 2.5-2 is a more complete representation of system components. These figures 
will prove helpful in studying the 7090 Reference Manual. 



21 



Decrement 









\ 

Taq 




■ i r— ■ 

S 1 2 

i i 


i t" r i ~t~ r i — r— 

3 

i i i i i i i i 


1213 
i 


I I 1 


18 20 
i i 


1 1 — T 1 1 1 1 1 1 1 1 1 1 1 

Address 

i i i i i i i 'i 



Indirect Effective 
Address Address 



CPU Instruction Word Address Modification Fields 



Variable Length Shift 
Mpy or Div Count Count 



— r i 

S 1 2 

i i 


1 1 'I 1 1 T ' 

3 

i i i i i i 


1 

10 

i 


i — r 1 t r~T 

12 17 
i i i i i 


1 1 
i i 


I I 1 1 1 

21 




1 'ITT 1 - T"1 1 

28 35 

i i i i i i i i 




















Convert 


Address 



Count 



CPU Instruction Word Count Fields 



FIGURE 2.5-1 . CPU INSTRUCTION WORD VARIATIONS 



Following the study of the instructions and commands used in the 7090 system, study 
the operation of the individual current switching component circuits that make up the 
system. These are explained in Transistor Components Circuits, IBM Customer 
Engineering Manual of Instruction, Form 223-6889. 

These books, together with the information previously presented in this manual, 
comprise the information needed to continue the study of this manual beyond this point. 

The following information in this manual, although generally in outline form, is quite 
specific and requires the use of 7090 systems diagrams to provide maximum benefit. 



22 



3. 0. 00 CPU INTERNAL FUNCTIONS 



3. 1. 00 FUNCTIONAL COMPONENTS 

Figure 3.1-1 shows the basic registers and switching units of the 7100 CPU. 
Because the registers and switching units have different requirements, they are 
made up of various types of basic components which are explained below. 

Shift Cell 

A shift cell allows simultaneous read-in and read-out operations. Shift cells are 
used to shift data to adjacent positions within a register, or to read out old data and 
read in new data simultaneously. 

The basic shift cell is shown in Figure 3. 1-2 A. Two triggers have multiple inputs 
to turn on the selected register position. The control lines "set" and "hold" are gen- 
erated by the CP set pulse. Note that "hold" falls prior to the rise of "set" and rises 
again prior to the fall of the set pulse. Refer to Figure 3. 1-2B. 

The numbers on the timing chart in Figure 3. 1-2B correspond to the test points of 
Figure 3. 1-2 A. With the input line active, the signal at test point 2 becomes active. 

Test point 2 conditions the +TO with its output, test point 3, conditioning one leg of 
the +TA. The set pulse conditions the other leg of the +TA. The output of this trigger, 
test point 4, remains active for the duration of the set pulse. Test point 4 conditions 
the lower +TO, so that test point 5 becomes active and conditions one leg of the +TA. 
Because "hold" becomes active prior to the fall of the "set," the lower trigger latches 
and retains the information. 

The registers that contain shift cells are: 

1. Storage register (SR) 

2. Accumulator register (AC) 

3„ Multiplier-quotient register (MQ) 
4. Index register (XR) 



Triggers 

A trigger acts as an information storage unit. Information can be read into a 
trigger, and retained there until the trigger is reset. 

The registers that contain triggers are: 

1. Program register (PR) 

2. Address register (AR) 

3. Sense indicators (SI) (This register actually uses two triggers for each 
position to permit complement operations; it should not be confused 
with shift cell registers. ) 



23 



From Multiplexor SB 



Comp Inds 





Indicators 




0 




35 



SC12-17-*AD3-8 



s 


Prog Reg 


Shift Ctr 




1 9 


10 


17 



Prog Ctr 
3 17 



Adr 


Sw 


3 


17 



2 Adr Reg 



17 



15 Pos 



Tag Reg 
18,19,20 



S-5 



SB OR'ing Multiplexor 



Stg Reg 



35 



18 Pos 



3-11 



12-17 



P-5 



Adder 



AC 



30-35 



Op Panel Keys 



3 17 
XR A,B,C 



1-5 



MQ 



30-35 



To Adr Sw in Multiplexor 



FIGURE 3.1-1 . 7090 CENTRAL PROCESSING UNIT 



-o 



no 



(3) 



+TA 



Set 



(4) 



© 



Hold 



+TO 



15L 



+TA 



I6L 



Set 

Hold _ 

Input (1) 

(21 
(31 
(4)_ 

(5L 

(6) 



Each Division Equals 20 Nanoseconds 



Output 



FIGURE 3.1-2. SHIFT CELL 



High Order 



Low Order 



Reset 
Count 

= 0 





o 







Input 



Count 

= 1 



Count 

= 2 





o 







Count 
= 3 





X 







1st Pulse 2nd Pulse 3rd Pulse 

FIGURE 3.1-3. COUNT-UP COUNTER 



(X = On; O = Off) 



25 



Switching Units 

Switching circuits are comprised of AND and OR logic blocks. They cannot hold 
information, and their output is conditioned only as long as the input is conditioned. 

The switching units are-. 

1. Address switches (AS) 

2. Adders (AD) (See Section 3. 1. 11 for arithmetic adding applications.) 
Binary Counters 

A binary counter is a group of binary trigger positions designed to count the number 
of input pulses to the low-order position. There are two types of binary counters: 

1. Count -Up Counter: Each position, as it goes off, reverses the status 
(on-off) of the next higher position (Figure 3. 1-3). 

2. Count-Down Counter: Each position, as it goes on, reverses the status 
of the next higher position (Figure 3. 1-4). 

Each counter position has three inputs (Figure 3. 1-5): 

1. Set Pulse: Presets counter to some initial status. 

2. Step Pulse: Advances (count up) or decreases (count down) a preset 
number. 

3. Reset Line: Resets counter positions to all zeros. 



Speed -Up Counting 

In a counter position for a large number, normal circuitry (where one position 
feeds the next higher position) can cause a considerable delay. An example of this 
delay is shown in Figure 3. 1-6. When each position goes off, it feeds the next 
higher position and reverses its status. Because of the high speed of the system, 
this delay must be overcome to insure reliable operation. The following system 
is used to reduce the delay. 

The outputs of several positions are AND'ed, and if all these positions are 
impulsed, their AND changes the next higher position, as shown in Figure 3. 1-7. 
The stepping of a low-order counter position may step all positions above it. 
Therefore, circuits are attached to the counter unit to speed up counter operation. 
Figures 3. 1-7A and 3. 1-7B show the logic of the speed-up circuits used with the 
shift counter and program counter. 



7090 Counters 

1. The program counter (PC) (instruction counter) is a count-up type (Systems, 
Volume 5, 03. 00. 05. 1-3. 05. 09. 1). See Figure 3. 1-7A. 

2. The shift counter (SC) is a count-down type (Systems, -Volume 5, 03.04.14.1- 
.03.04.19.1). See Figure 3. 1-7B. 



26 



High Order 



Low Order 



Preset 
Count 
= 7 



Count 

= 6 



J-L" 



Count 

= 5 



_n_ 



Count 
= 4 



_tlT 



1st Pulse 2nd Pulse 3rd Puis 

FIGURE 3.1-4. COUNT DOWN COUNTER 



Step 



Reset _ 


Counter 
Position 




Jet ^ 


>- 





-3^- To Next Higher Position 



FIGURE 3.1-5. BINARY COUNTER INPUTS 



10 



FIGURE 3.1-6. NORMAL COUNTER RIPPLE DELAY 



o 




X 




X 




X 




X 




X 




X 




X 




X 




X 







































Input 



Before Step 



After Step 



Adv 
PC 



PC 
6,7, 
and 8 

= 1 




A 

r 




Step 
PC 5 




















PC9 
10 & 
11 

Equals 
1 






A 




Step 
PC8 


















PC12, 
13 & 
14 

Equals 
1 






A 




Step 
PC11 


















PC15, 
16, & 
17 

Equals 
1 






A 




Step 
PC14 













Step 
PCI 7 



To PC5 



To PC8 



To PC11 



To PCM 



To PCI 7 



SCI 2, 
& 13 
Off 

Previou: 



SCI 4 & 
15 Off 
Previou: 
to Step 



SC16 & 
17 Off 
Pre- 
vious to 
.Step 



Step 
SC 



Step 
SC11 



Step 
SCI 3 



Step 
SCI 5 



Step 
SC17 



To SC11 



To SCI 3 



To SC15 



To SCI 7 



FIGURE 3.1-7B. SHIFT COUNTER STEP CONTROL 



FIGURE 3.1-7A. PROGRAM COUNTER STEP 
GENERATOR 



27 



3. 1. 01 Storage Register (SR) (Systems 2. 01. 00. 1-2. 01. 37. 1) 



The storage register is a 37 -position shift cell register and the register positions are 
labeled (S), (1-35), and (Q). All instructions and data coming into or leaving the CPU 
go through the storage register, positions (S), (1-35). Storage register positions (S), 
(1-35), and (Q) are also used for holding factors and partial results during the execu- 
tion of many instructions. 

3. 1. 02 Accumulator Register (AC) (Systems 2. 03. 00. 1-2. 03. 37. 1) 

The accumulator is a 38-position shift cell register used in nearly every arithmetic 
operation. The register positions are labeled (S), (Q),(P), (1-35). Positions (S), (1-35) 
accommodate the word in standard operations. Positions (Q) and (P) are used as 
overflow positions because the sum of two 35-position numbers can be greater than 35 
positions. Postion P also holds the S bit of a word during logical operations. As the 
name implies, the accumulator is the unit into which results accumulate; it does not 
perform the addition. 

3. 1. 03 Multiplier-Quotient Register (MQ) (Systems 2. 04. 00. 1-2. 04. 35. 1) 

The multiplier -quotient register is a 36 -position shift cell register with the positions 
labeled (S), (1-35). This register has several uses. During a multiply operation it holds 
the multiplier; after the multiply operation it holds the least significant half of the prod- 
uct. During a divide operation, it holds the least significant half of the dividend; after 
the divide operation it holds the quotient. In several floating point operations, the MQ 
holds the least significant 35 bits of the result. 

3. 1. 04 Sense Indicator Register (SI) (Systems 2. 06. 00. 1-2. 06. 35. 1) 

The sense indicator register is a 36-position trigger register, labeled (0-35). Each 
position of the register contains two triggers. One of the triggers is used to retain in- 
formation in the register, and the other trigger is used as a remembering device during 
an invert operation. The sense indicator register is controlled completely by the pro- 
gram and is not used by the computer as a part of its arithmetic operations. It can be 
used as a set of switches which are set and tested by the program to check the progress 
or direction of the program. The SI register may also be used to store words or parts 
of words temporarily and, in this way, it is useful for altering and testing words. The 
SI register inputs and outputs go directly to the storage register. 

3. 1. 05 Index Registers (XR) (Systems 2. 07. 01. 1-2. 07. 15. 1) 

There are three 15-position shift cell registers called index registers A, B, and C. 
The register positions are labeled (3-17). The three registers are identical in opera- 
tion and are used for instruction address modification. , They are activated by the tag 
positions of an instruction and can be used singly or in parallel or combinations. They 
modify an address by adding the complement of their contents to the address; in effect , 
the address is reduced by the contents of the index register. 

There are many instructions which operate on the index registers, thereby making 
these registers useful programming tools for counting, word alteration, program loop 
control and so forth. 



28 



3. 1. 06 Program Register (PR) (Systems 3. 04. 00. 1-3. 04. 03. 1) 

The program register is a ten-position trigger register whose positions are labeled 
(S), (1-9). The program register receives the operation code of the instruction directly 
from the storage bus and holds the operation code throughout the execution of the instruc- 
tion. The output of the program register is decoded to initiate and control the CPU so 
it will execute the instruction. Positions (1-5) contain the primary operation part of the 
operation code; positions (6-9) contain the secondary part. 

3. 1. 07 Shift Counter (SC) (Systems 3. 04. 14. 1-3. 04. 19. 1) 

The shift counter (SC) is an eight -position, count-down counter. The SC counts the 
number of shifts taken during a shift operation and is also used as part of the decoder 
for operations that have a primary operation code of 76. See Section 5. 00. 00. 

Figure 3. 1-8B is a reproduction of an ALD page without the reset lines, but with 
special terms applied to blocks or combinations of blocks. 

Because the SC is a step-down counter, a number must be set in the counter at the 
start of the operation. The address switches are gated to set the SC. Considering a 
shift of seven, the "+P AS to SC" line to positions 15, 16, and 17 will be active. This 
condition causes one trigger (A or B) in each position, to latch on, thereby indicating 
a 1 in the three positions. 

With "AS 17 to SC 17" active, the +OR circuits at 3F and 3H are conditioned, indi- 
cating that trigger B will latch on and trigger A will be in a preset condition. The in- 
phase output of the +OR at 3F conditions the A trigger of position 16, along with "AS 16 
to SC 16. " The out-of-phase line of the +OR at 3F deconditions trigger B. Now positions 
16 and 17 have a bit. Position 15 has both triggers preset by "AS 15 to SC 15. " Because 
the SC is not being stepped at this time, trigger B of position 15 will latch on. 

The SC is divided into groups of two for lookahead operations. The outputs of each 
group are AND'ed together to determine if the higher order positions are to be stepped. 
The high-order position of each group have a line, "-N SC set gate," to prevent an error 
if a number other than seven is set in the SC. Suppose a 1 is in the AS; this sets trig- 
ger B of position 17. The in -phase output of the +OR at 3F will condition one leg of the 
+AND at 4D, as this in-phase output did previously. Because position 16 trigger B is 
off, the out-of-phase output of the +OR at 3B is plus. With trigger B of position 16 off 
(not turned on yet because of circuit delays), the out-of-phase output of trigger B is also 
plus. Normally, this output would condition the preset AND circuit at 4C and the A trig- 
ger of position 16 would turn on. The turning on of the A trigger of position 16 is pre- 
vented by "-N SC set gate," which deconditions the circuit at 4C whenever the AS is 
gated to the SC . 

A 70 ns pulse, generated by the CP set pulse, steps the SC. When in automatic, the 
SC is stepped every clock pluse until reaching zero. The "+N step SC 17" and "-N step 
SC 17" are generated by the same pulse and will be active at the same time. • These two 
lines condition triggers A and B of position 17. Because trigger B of position 17 is on, 
the minus step pulse to the +AND at 4F will turn off. Because trigger B of position 16 
is in the preset condition, it will latch on with the out-of-phase output of position 17 go- 
ing positive. Position 15 will not be affected because the step control circuits are not 
conditioned. Both triggers A and B of position 17 are off, with trigger A preset. Both 
positions 15 and 16 have trigger B on and the SC value is now six. 



29 



The next step pulse (2nd) latches on the A trigger of position 17. The in-phase out- 
put of the +AND at 4H conditions the + OR at 3F, presetting trigger B of position 17. The 
out-of-phase output of the +OR at 3F goes minus and causes trigger B of position 16 to 
turn off. Because the A trigger was not preset, both triggers in position 16 will be off 
at the end of the step pulse. After the step pulse, however, trigger B will be preset. 
Trigger A of position 17 can stay on only for the duration of the step pulse. When the 
step pulse ends, the 68 uuf capacitor at 2H keeps the output of the preset AND circuit 
active long enough to allow trigger A to latch on. At the end of this step pulse (2nd) , 
the SC contains a 5. 

The next step pulse turns off position 17, and only trigger B of SC 15 is on. The SC 
is now 4. 

Step control circuits now allow positions 15 and 17 to receive the next step pulse. 
This step pulse will turn off position 15 by deconditioning the AND circuit that corre- 
sponds to 4F in Figure 3. 1-8B (Systems 03. 04. 16. 1 for actual circuit). The B trigger 
of position 17 and the A trigger of position 16 are latched on. The SC will continue to 
step down until it reaches zero. Figure 3. 1-8A is a timing chart that shows the stepping 
of the SC. The solid lines indicate the latched condition, while the dotted lines indicate 
a preset condition. 

3. 1. 08 Program Counter (PC) (Systems 3. 05. 00. 1-3. 05. 07. 1) 

The program counter (PC) is a 16-position count-up counter. The high-order position, 
PC2, is used to signal that all addresses in core have been set to zero, on the clear 
operation only. The remaining positions, 3 through 17, indicate the location of the next 
instruction to be executed by the CPU when it is operating sequentially. 

Figure 3. 1-9B is a reproduction of an ALD page without the reset lines, and with 
special terms applied to blocks or combinations of blocks. 

The step of the PC is generated on Systems 03. 05. 08. 1. Two lines, "-N STP PC 
17" and "N minus to STP PC 17, " are generated by +-N advance PC CNTR. " These 
two lines are active whenever PC is stepped. 

With the PC set to zero, a step pulse will advance the PC to one. To do so, the step 
pulse AND's with the out-of-phase output of trigger B of position 17 (now off), to condi- 
tion the AND circuit at 4H. The +A at 4H presets trigger A of PC 17. 

Trigger A remains preset until the step pulse falls (becomes positive), and then trig- 
ger A latches on. A capacitor holds the preset condition until the latching action takes 
place. 

With trigger A latched on, its output conditions the -^OR at 3G as well as the +OR at 
3H, signaling a 1 in PC17. With the +OR at 3G conditioned, its in-phase output presets 
trigger B of PC17. The in-phase output of 3G also presets the +AND at 4D, which in 
turn presets trigger A of position 16. 

The next step pulse will reset trigger A and latch trigger B of PC17. After the step 
pulse, trigger B of PC17 goes off. With the PC17 trigger off, its out-of-phase output 
becomes plus, conditioning the +AND at 4E, which latches trigger A of PC16. The +OR 
at 3C is conditioned, presetting trigger B of PC16. The output of the +OR at 3C also 



30 



Step Pulse 
Trig A SCI 7 
Trig B SCI 7 
Trig A SCI 6 
Trig B SCI 6 



Trig B SC15 

SC Value 7 6 



in 



FIGURE 3. 1-8A. SHIFT COUNTER 



(Tgr B) 



-N SC Set Gate 



+P AS 16 to SC16 



(Tgr A) 



Position 16 



Output 



CAP 
68 uu 



-N Stp SCI 7 



(Tgr B) 



+P AS17 to SC17 



+N Step SCI 7 



(Tgr A) 



□ 



Position 17 



Output 



CAP 
68 uu 



FIGURE 3. 1-8B. SHIFT COUNTER POSITIONS 16 AND 17 



Step Pulse 
Trigger A PC 17 

Trigger B PC17 

Trigger A PC 16 

Trigger B PC 16 

Trigger A PC 15 

Trigger B PC 15 
Value 



(Tgr B) 



n n 



rr 



i L 

n 



in 



0 1 2 3 4 5 

FIGURE 3. 1-9A. STEPPING OF THE PROGRAM COUNTER 




FIGURE 3. 



1-9B. PROGRAM COUNTER 



POSITIONS 16 



AND 17 



presets trigger A of PC 15 through the +AND circuit at 4H on Systems 03. 05. 06. 1. This 
+AND circuit corresponds to the preset AND circuit at 4H in Figure 3. 1-9B. At this 
point, both triggers of PC 17 are turned off, trigger A of PC 16 is on, and trigger B is 
preset. Trigger A of PC15 is also preset. 

With the "next step PC17," position 17 will turn on in the same manner as before. 
The different positions will turn on and off as the PC counts up. Figure 3. 1-9A is a 
timing chart showing the stepping of the PC with six pulses. The solid lines indicate 
the actual condition of a trigger; the dotted lines, a preset condition. 

The PC is divided into groups of three, with the outputs of the different groups used, 
as a lookahead circuit. Each of these groups of three acts like positions 15, 16, and 
17, just discussed; however, they will not be stepped as often. 

3. 1. 09 Address Register (AR) (Systems 3. 06. 00. 1-3. 06. 04. 1) 

The address register is a 15-position register whose positions are labeled (3-17). 
The address register gets the desired core storage address before a word is brought 
out of core storage. The address goes from the address register to the address selec- 
tion components in core storage. 

3. 1. 10 Address Switches (AS) (Systems 3. 06. 06. 1-3. 06. 10. 1) 

The address switch is a 15-position gating circuit with positions labeled (3-17). The 
switches receive information from the program counter or the adders and this informa- 
tion can be gated through the switches to the address register, shift counter, or storage 
register. 

3. 1. 11 Tag Registers (Systems 2. 08. 01. 1) 

The tag register is a three -position trigger register numbered 18, 19, and 20. It is 
fed directly from the multiplexor storage buses and is used to hold the tag portion of an 
instruction during the instruction execution. 

3 . 1 . 12 Adders (AD) (Systems 2 . 02 . 01 . 1-2 . 02 . 37 . 1) 

The adders are transistor switching circuits used to combine binary numbers or words 
into a binary sum. There are 37 separate adders (Q), (P), (1-35) in the adder unit 
capable of adding two binary words. 

The adders do the arithmetic calculation of the system. Basically all the system will 
do is add. Subtraction is done by adding a complement number. Multiplication is 
accomplished by a series of additions and shifts. Division is accomplished by a series 
of complement additions and shifts. 



32 



Figure 3. 1-8 shows a basic adder circuit. The adder circuit is designed to use three 
inputs at one time with one of the three inputs being a carry from the next low order 
position. The adder produces two outputs, a sum and a carry. The adders are designed 
to follow the example of binary addition illustrated in Figure 3. 1-9. 

Some adders have several inputs because the adders have multiple uses. However, 
only two of the outside inputs and the carry in can be active at the same time. The add- 
ing function of these multipurpose adders is the same as shown in the basic adder cir- 
cuit, Figure 3.1-8. 

Adder Unit and Look Ahead Circuits (LAC) 

The basic principle behind connecting individual adders together to make an adder 
unit is to take the carry out of one adder and connect to the carry in of the next high 
order position adder. This would mean that, if all adder positions contained a one and 
a one was added to the low order position, a carry would have to ripple through the adder 
unit from the low order position to the high order position. As the carry ripples through 
the adders the logic circuits introduce a delay into this action. The 7090 is too fast to 
accept these conditions. To overcome this slow ripple condition in the adders, the 7090 
adders have associated circuits that speed up the carry operation. These circuits de- 
termine how many adder positions the carry must go through, then send the carry al- 
most immediately to a higher order adder a few positions from the initial carry impulse. 
These carry speed-up circuits are called look ahead circuits (LAC). The logic of the 
operation of the look ahead circuits is shown in Figure 3. 1-10 and Figure 3.1-11. Notice 
that for look ahead purposes the adders are grouped into five groups of five adders each 
and two groups of six adders. The output of the first stage LAC feeds the inputs of the 
second stage LAC. 

All adder positions, except the Q position, have two LAC outputs. One is the OR 
LAC and the other is the AND LAC. The OR LAC gives a usable output to the first stage 
LAC when a bit is sent to either input 1 or input 2 or both. The AND LAC gives a usable 
output to the first stage LAC when bits are sent to both inputs 1 and 2. 

There are two outputs from the first stage LAC. One output is the carry out LAC and 
the other output is active when all adders in the group are receiving at least one input. 
This latter output is simply called look-ahead. The carry out (CO) LAC is active when 
any combination of bits in that particular group of adders would cause a carry out of the 
high order adder of the group. 

The second stage LAC uses the outputs of the first stage LAC, along with a line to 
indicate a carry in or a bit to adder 35. These LAC initiate a carry into the low order 
adder of the next higher group. 

Following through the first and second stage LAC, note that if adder 35 has an AND 
LAC output and adders 34-30 have OR LAC outputs, a carry in would be sent to adder 
29. If all adders have an OR LAC output, these outputs would cause a carry in to be 
sent to adders 29, 24, 19, 14, 8, and 3 almost simultaneously if a carry into adder 35 
occurred. 

Note that a carry has to ripple through a maximum of 6 adders rather than through 
37 because of the look ahead circuits, and the carry operation through the adders has 
been greatly speeded up. 



33 



35A 
34V 
33V 
32V 
31V 
30V 



29A 
28V 



27V 
26V 



25V 



24A 
23V 



22V 
21V 



20V 



19A 
18V 



17V 
16V 



15V 



14A 
13V 
12V 
11V 
10V 
9V 



8A 
7V 
6V 
5V 
4V 



3A 
2V 
IV 
PV 
QV 



34A 

33V 



32V 
31V 



30V 



28A 
27V 
26Y_ 
25V 



-23A. 
22V 

.2QY_ 



18A 
17V 



16V 
15V 



13A 
12V 
1 IV 
10V 
9V 



7A 

5V 
4V 



2A 
IV 
PV 
QV 



CO 



33A 
32V 
31V 
30V 

32A 
_3_LY_ 
30V 



27A 

2£Y_ 

25V 



26A 
25V 



22A 
21V 



20V 



21A 
20V 



17A 
16V 



15V 



16A 



15V 



12A 
11V 
10V 
9V 



11A 
10V 
9V 



6A 
5V 
4V 



5A 
4V 



1A 

PV 
QV 



PA 
QV 



31A 
30V 



30A 



_35Y_ 
34V 

33V 
32V 
31V 

3QV 



25A. 



LA(35-30) 
2.02.46.1 



Co(35-30) 
2.02.46.1 



29V 

2SY_ 

27V 
26V 
25V 



20A 



Co(29-25) 
2.02.45.1 



LA(29-25) 



24V 
23V 
22V 
21V 
20V 



_L5A_ 



1 



2.02.45.1 



Co(24-20) 
2.02.44.1 



19V 

iav_ 

IZY_ 
16V 

LA(24-20) 15V 
2.02.44.1 



1 



10A 
9V 



9A 



LA(19-15) 
2.02.43.1 



Co(l 9- 15) . 
2.02.43.1 



14V 
13V 
12V 
I IV 
10V 
9V 



4A 



8 V 
7 V 
6 V 
5 V 

LAQ4-9) 4 V 
2.02.42.1 



Co(14-9) 
2.02.42.1 



OA 



I 



Co(8-4) 
2.02.41.1 



3 V 
2 V 
1 V 
P V 

LA(8-4) Q V 
"2.02.41.1 



O 



Co(3-Q) 
2.02.40.1 



LA(3-Q) 
'2.02.40.1 



A = 2 Bits (AND V = At Least 1 Bit (OR Co = Carry Out 
LAC) lac) 



LA = Look Ahead 
FIGURE 3.1-10. FIRST STAGE LOOK AHEAD CIRCUITS 



Cin 35 i 
( 35-30) LA 



Co(35-30) 



+ A 



Cin 35 
(3 5-30) LA 
( 29-25(LA 

C o(35-30)r - 

( 29-25)LA 



Co(29-25) 



Cin 35 
( 35-30)LA 
( 29- 25) LA 
( 24-20)LA 

C o(35-30) . 

( 29-25)LA + 
( 24-20)LA A 



C o(29-25)r 
( 24-20)LA 



Co(24-20) 



Cin 29 
2.02.53.1 



Cin 24 
2.02.52.1 



Cin - Carry In 



FIGURE 3.1 



Cin 35 
(35-30)L£ 
( 29-25)L/ 
( 24-20)L/ 
( 19-15)L/ 
( 14-9)LA 

Co(35-30; - 

(2 9-25)LA 

( 24-20)LA 

(1 9-15)LA 

( 14-9)LA 

C o(29-25) r 
( 24-20)LA 
(1 9-15)LA 
( 14-9)LA 

C o(24-20] - 
(1 9-15)LA 
( 14-9)LA 

C o(19-15V - 
(14-9)LA 



Co(14-9) 



O 



Cin 14 
2.02.52.1 



C in 35 
(3 5-30)LA 
(29-25JLA 
(2 4-20)LA 
(1 9-15)LA 
(1 4-9) LA 
(8-4)LA 

C o(35-30) , 
(2 9-25)LA 

(2 4-20)LA 
(1 9-15)LA 

( 14-9)LA 

(8-4)LA 

C o(29-25) . 
(2 4-20)LA 
(1 9-15)LA 
( 14-9)LA 
(8-4)LA 

Co(24-20: - 
(1 9-15)LA 
(1 4-9) LA 
(8-4)LA 

Co(19-15; 
( 14-9)LA 
(8-4)LA 

Co(14-9) . 
(8-4)LA 



Cin 3 



(3-Q)LA 



Co(3-Q) 



-O 



Overflow (Co-Q) 
2.02.53.1 



Cin 3 
2.02.50.1 



Cin 8 
2.02.51.1 



Co(8-4) 



LOOK AHEAD CIRCUITS 



Carry From Adder 9 to Adder 8 

A special circuit can prevent or allow a carry from adder 9 to adder 8. The reason 
for this is that a floating-point word has two separate parts, a characteristic (positions 
1-8) and a fraction (positions 9-35). During some floating-point operations, a carry out 
of the fraction must not be allowed to gate to the characteristic. 

3. 2. 00 INSTRUCTION DECODING AND PROCESSING 

The output of the program counter is gated to the address register through the address 
switches. The output of the address register is then used to locate the address of the 
instruction in core storage. The output of core storage is sent to the storage register 
and the operation code is also sent to the program register. The output of the program 
register then is decoded to instruct the system. 

3. 2. 01 Operation Decoders 

The output of the program register feeds two decoders. The outputs of positions 1-5 
feed the primary operation decoders (POD), and the outputs of positions 6-9 feed the 
secondary operation decoders (SOD). The primary operation is used to establish the 
basic execution control routing. The secondary operation decoder is used only for the 
sense, or primary operation 76 instructions. 

Some similar instructions have the same primary operation code. Direct outputs of 
the program register or storage register are sent to individual machine circuits to 
cause the machine to operate according to the minor differences among these similar 
instructions. 

3. 2. 02 Control Circuits 

The control circuits cause the machine to operate according to the decoding of the 
instruction. Specific control circuits cause data to be moved and functions to be per- 
formed so the machine gives the desired results of the instruction. 

3. 2. 03 Pulses 

The control circuits require a great number of pulses and gates. These pulses and 
gates, obtained by mixing clock pulses from the multiplexor clock, function in the 7090 
as the circuit breakers function in electro -mechanical card machines. They are used 
to establish proper sequence of operation in the system. 

3. 3. 00 BASIC CYCLE 

The basic cycle in the CPU is 2. 1818 microseconds. It is divided into 12 equal times 
of the 181. 8 milli-microseconds each. The 12 times are sent to the CPU from the 
multiplexor. 

There are three different types of cycles used by the CPU. These are: 

1. Instruction I cycle 

2. Execution E cycle 

3. Logic L cycle 

Every instruction has an I cycle. This cycle brings the instruction from core stor- 
age to the CPU, where the instruction is decoded. Some instructions require only the 
I cycle for their execution; most instructions require additional cycles. 



36 



E cycles are used when information is to be moved between core storage and the CPU 
to execute an instruction. 

L cycles are used to execute an instruction when information from core storage is 
not needed. 

Most instructions use only one E or L cycle for their execution, but some instruc- 
tions require multiple E or L cyclps. For example: a convert instruction requires 
several E cycles; a multiply instruction requires several L cycles. 



37 



4. 0. 00 IBM 7606 MULTIPLEXOR 



The IBM 7607 Multiplexor is best described as the unit of the 7090 system that passes 
all data to or from core storage. These data may be CPU instructions, data channel 
commands, data to be processed by the CPU, data that has been processed by the CPU, 
or input-output words. Data that go to core storage come to the multiplexor from the 
CPU and data channels. 

Multiplexing is the forming of parallel paths from a serial path when data are going 
to core storage. When data are coming from core storage, multiplexing is the forming 
of a serial path from parallel paths. 

In addition to its function of multiplexing, the multiplexor contains the clock for the 
CPU and data channels, and a matrix for zero testing data coming from core storage. 
The multiplexor also contains look-ahead circuits that are used in conjunction with the 
data channel operations. The CPU clock and CPU multiplexing circuits are described 
in this manual; the remainder of multiplexor functions are described in Customer 
Engineering Manual of Instruction, IBM 7607 Data Channel , Form 223-6898. 

Two of the four standard modular system (SMS) sliding gates in the multiplexor 
frame are reserved for special features. The remaining two SMS sliding gates house 
the multiplexor circuitry. 

Data flow from core storage to the multiplexor storage bus, then to either the CPU 
or any one of the data channels. See Figure 4. 0-1. The address field (21-35) of the 
data coming from core storage also flows to the multiplexor address switches. The 
flow through the multiplexor address switches is controlled by the look-ahead circuits 
in the multiplexor. 

Data going to core storage flow through the multiplexor storage bus OR'ing. This 
bus is a group of OR circuits that multiplex data going to core storage. It is completely 
independent of the multiplexor storage bus. 

The multiplexor address switches receive addresses from the CPU, data channels, 
and the multiplexor storage bus. These switches multiplex the address sent to core 
storage and the location counter switches in each data channel. 

4. 1. 00 MULTIPLEXOR FUNCTIONAL UNITS 

The multiplexor contains the multiplexor clock, storage bus, storage bus OR'ing, 
and the address switches. 

4.1.01 Multiplexor Clock 

The multiplexor clock (Figure 4. 1-1) supplies timing pulses to the 7090 system. The 
clock consists of a 12-stage ring. The clock is started by turning on the zero clock 
trigger with a start clock pulse. The A0(D1) clock pulse is obtained by gating the last 
half of the zero clock trigger pulse with the negative portion of the even ring drive pulse. 
The rise of the A0(D1) pulse turns on one clock trigger. The A1(D1) pulse is obtained 



38 



Memory Data 
Register Out 
Sw's 
0- -71 



CPU 
Storage Register 



-35 




Channel 
Address Sw's 



-17 



CPU 
Address Register 

3- -17 



Multip 
Storage 


exor 
Bus 


S, 1- - 


20 | 21-35 



Multiplexor 
Storage Bus 
OR'ing 



S, 1- 



-35 



Multiplexor 
Address Switches 



17 



CPU 
Storage Bus 

S, 1- -35 



Channel 
Input Switches 

S, 1- -35 



Memory Data 
Register in 
Sw's 
0- -71 



Memory 
Address Register 

3- -17 



Channel Location 
Counter Sw's 



3- 



-17 



FIGURE 4.0-1. FLOW TO AND FROM THE MULTIPLEXOR 



39 



Even Ring Drive 

Odd Ring Drive 
Starr Clock Pulse 

0 Clock Trigger 

AqD] Clock Pulse 

1 Clock Trigger 

Ai Dl Clock Pulse 

2 Clock Trigger 
A2DI Clock Pulse 

3 Clock Trigger 
A 3 D! Clock Pulse 

4 Clock Trigger 
A4D1 Clock Pulse 

5 Clock Trigger 
A5D1 Clock Pulse 

6 Clock Trigger 
A D D 1 Clock Pulse 

7 Clock Trigger 
A7D1 Clock Pulse 

8 Clock Trigger 
A8D] Clock Pulse 

9 Clock Trigger 
A 9 D 1 Clock Pulse 

10 Clock Trigger 
A]qD 1 Clock Pulse 

1 1 Clock Trigger 
A] 1 Di Clock Pulse 



ruijrirLruiJiJi^rLrLr^ 
_rmimjmnimnj^JxrihjiJirL 



u 



n 



JT 



n 



_JT 



n 



_n_ 
n_r 

_jt 



n 



La 



n 



JT 



"LJ" 
_TL 



JT 



JT 



JT 



1_T 

_JT 



UJ 

I 

_n 



i— r 

_TL 



i__r 

_JT 



JT 



JT 



JT 



JT_ 



JT_ 



_n_ 
~u 
n 



FIGURE 4.1-1. MULTIPLEXOR CLOCK 



40 



by gating the last half of the 1 clock trigger pulse with the negative portion of the odd 
ring drive pulse. The rise of the A1(D1) pulse turns on two clock trigger, and the turn- 
ing on of the two clock trigger turns off zero clock trigger. This sequence continues 
through 11 clock trigger. The rise of the All(Dl) pulse turns zero clock trigger on 
again. The following chart shows the controls significant to each stage of the ring. 



Clock 


Turned 








Gated 


Tgr 


on by 


Turned off by 


Duration 


Output 


Output 


0 


All(Dl) 


2 clock tgr 


A11(D2) 


A11(D2) 


A0(D1) 


1 


A0(D1) 


3 clock tgr 


A0(D2) 


A0(D2) 


A1(D1) 


2 


A1(D1) 


4 clock tgr 


A1(D2) 


A1(D2) 


A2(D1) 


3 


A2(D1) 


5 clock tgr 


A2(D2) 


A2(D2) 


A3(D1) 


4 


A3(D1) 


6 clock tgr 


A3(D2) 


A3(D2) 


A4(D1) 


5 


A4(D1) 


7 clock tgr 


A4(D2) 


A4(D2) 


A5(D1) 


6 


A5(D1) 


8 clock tgr 


A5(D2) 


A5(D2) 


A6(D1) 


7 


A6(D1) 


9 clock tgr 


A6(D2) 


A6(D2) 


A7(D1) 


8 


A7(D1) 


10 clock tgr 


A7(D2) 


A7(D2) 


A8(D1) 


9 


A8(D1) 


11 clock tgr 


A8(D2) 


A8(D2) 


A9(D1) 


10 


A9(D1) 


0 clock tgr 


A9(D2) 


A9(D2) 


A10(D1) 


11 


A10(D1) 


1 clock tgr 


A10(D2) 


A10(D2) 


All(Dl) 



Note that the pulse width of each clock trigger is twice that of an individual clock 
pulse. This slower switching of the clock triggers provides for increased reliability 
in the operation of the clock. 

The multiplexor clock pulse distribution enables the individual clock pulses to be 
distributed to the CPU and data channels. Because of inherent delays in logic blocks, 
clock pulses distributed to the CPU arrive about one clock pulse late. For this reason, 
those clock pulses distributed from the multiplexor to the CPU are labeled one higher 
than the actual clock pulse. Therefore, an A0(D1) pulse going to the CPU would be 
labeled A1(D1). This pulse leaves the multiplexor at AO time but, when it arrives at 
the CPU, the A1(D1) pulse is rising at the multiplexor. It is important to notice that 
A1(D1) pulses at the CPU and multiplexor now are in coincidence, although developed 
from different clock triggers. This provides for continuity in the timing relationship 
between the CPU and multiplexor. 

4. 1. 02 Multiplexor Storage Bus 

The multiplexor storage bus (Figure 4. 1-2) routes all data from core storage to 
either the data channels or the CPU. Seventy-two lines from core storage feed the bus, 
36 of which lines carry data at a given time. Lines 0-35 are logically OR'ed with lines 
36-71, respectively. 

The bus feeds a group of 36 AND circuits that act as inputs to the CPU. The bus also 
feeds both banks of the data channel by way of the channel buses. 

In a multiplexor storage bus test, positions 1-35 of the multiplexor storage bus feed 
a matrix, which tests positions 1-35 and 3-17 for a zero condition. The zero test on 
positions 3-17 is used in conjunction with the multiplexor look-ahead circuits. Zero 
testing positions 1-35 provide for minimum execution time of various CPU instructions. 



41 



Memory Data 
Register Out Sw's 



0- 



-35 36- 



•71 



Multiplexor 
Stg Bus to 
CPU Stg Bus 

1 .00.01 .1 



Multiplexor 
Storage Bus 



S,l- 



-20 | 21- -35" 



AND 



S.I- TIM?- -35 



Channel Bus 
A - D 
S,l- -35 

2.05.10.1 



\ 

Channel Bus 
E - H 
S,l- -35 



2.05.10.1 



Multiplexor 
Address Sw's 

3- -y 

3.06.22.1 



CPU 
Inst Reg 
S,l_- -9_ 

3.04.00.1 



CPU 
Storage Reg 
S,l- 

2.01 .00.1 



Channel 

Input Switches 

A-D 
S,l- : 

60.26.01.1 



35 



Channel 
Input Switches 

s,i- E " H 



-35 



60.26.01.1 



Channel Location 
Counter Sw's 
E-H 



17 



60.10.13.1 



Memory 
Address Register 

3- -17 

1 .02.00.1 



Channel Location 
Counter Switches 
A-D 

3^ -17 

60.10.13.1 



FIGURE 4.1-2. FLOW FROM MULTIPLEXOR TO CPU 
AND DATA CHANNELS 



CPU 
Storage Register 

IS,] -351 

2.01.00.1 



Channel A-D 
Stg Bus Sw's 

S,l- -35 

60.10.19.1 



Channel E-H 
Stg Bus Sw's 

S,l- -35 

60.10.19.1 



Multiplexor 
Stg Bus OR'ing 



2.05.22.1 



Memory Data 
Register in Sw's 



0- -71 



FIGURE 4.1-3. FLOW FROM CPU AND DATA CHANNELS 
TO MULTIPLEXOR 



42 



4. 1. 03 Multiplexor Storage Bus OR'ing 

All data going to core storage are routed through the multiplexor storage bus OR'ing 
circuits. See Figure 4. 1-3. These circuits consist of OR circuits that multiplex data 
coming from either bank of the data channels or the CPU. Positions S, 1-35 of the CPU 
storage register are logically OR'ed with positions S, 1-35 of both banks of channel 
storage bus switches. This provides the proper isolation between the three sets of in- 
puts to the bus, and allows for the proper matching of the output. 

It is important to notice that data being routed through these circuits are gated at the 
CPU storage register or the channel storage bus switches. 

The output of the OR circuits consists of 36 (S, 1-35) lines, powered and matched, 
to route data to core storage. 

4.1.04 Multiplexor Address Switches 

The address, where data are taken to or from, must be switched through the multi- 
plexor address switches. These switches determine whether the address going to 
core storage is from a data channel, the CPU, the multiplexor storage bus, or 
is a forced address due to a channel trap. The switches also provide isolation between 
the various inputs. The switches have three outputs, all of which are active simultan- 
eously. Two of the outputs feed both banks of the data channels and terminate at the 
location counter switches. The third output feeds the memory address register in core 
storage. 

4. 2. 00 DATA FLOW AND CONTROL 

Data flow through the multiplexor and its associated control circuitry in the CPU 
can best be described by examining the following paths: 
CPU to core storage 
Core storage to CPU 

4. 2. 01 CPU to Core Storage 

Data that flow from the CPU to core storage (Figure 4. 1-3) are routed from the stor- 
age register through the multiplexor storage bus OR'ing circuits to the memory data 
register. Data flow is controlled by gating at the output of the storage register. The 
data are gated during an E cycle in which CPU control circuitry calls for store control. 

The address at which the data are being stored is switched through the multiplexor 
address switches. The CPU address register output is gated through these switches as 
long as the B time trigger is not on. The address is sampled at the memory address 
register at a given time. 

The data flow from the multiplexor to core storage on 36 data lines. At core storage, 
the data must be set to either 0-35 or 36-71 of the memory data register. The address 
set to the memory address register specifies which half of the memory data register 
is set. 



43 



4. 2. 02 Core Storage to CPU 



When in automatic status, data flow from core storage to the CPU (Figure 4. 1-2) 
always occurs during I cycles and may occur during E cycles. In either case, the data 
are routed to the multiplexor storage bus where they are gated to the CPU. Data trans- 
mitted to the CPU during I cycles are in the format of instructions, whereas data trans- 
mitted to the CPU during E cycles may be in any format. 

Notice that the bus unconditionally feeds both banks of data channels. However, data 
are gated through the channel input switches only during B cycles or the E cycle of a 
reset and load or load channel instruction. The address field (21-35) of the bus also 
feeds the multiplexor address switches. These positions are gated through the switches 
only during a look -ahead address control operation. 

I Cycle Flow 

At I6(D3), data on the multiplexor storage bus are gated to the CPU. CPU storage 
bus positions S, 1-35 are set to the storage register at 17 (Dl), while positions S, 1-11 
are routed to the instruction register. If the CPU storage bus positions 1 or 2 hold a 
one at 18 (Dl), bus positions S, 1, and 2 are set to instruction register positions S, 8, 
and 9, respectively. If the CPU storage bus positions 1 or 2 do not hold a one at I8(D1), 
bus positions S, 3-11 are set to instruction register positions S, 1-9 respectively. 

E Cycle Flow 

During all E cycles in which store control is not up, the multiplexor storage bus is 
gated to the CPU at E6(D3). At E7(D1), positions S, 1-35 of the CPU storage bus are 
set to the storage register. 



44 



5. 0. 00 CPU DATA FLOW AND TIMING 



5.1.00 I CYCLE 

I cycle operation is much the same for all instructions. E and L cycle operations 
vary depending on the instruction. 

I cycle operation is shown in Figure 5. 1-1. The end operation trigger (END OP TGR) 
is turned on during the last cycle of an operation and for an initial starting condition. 
This causes the I time trigger to be turned on. Also with the end operation trigger on, 
the address of the instruction is sent to core storage. The instruction is then taken 
from that address in core storage and sent to the CPU on the storage bus (SB). The 
instruction is put into the storage register (SR) and the operation code is sent to the 
program register (PR). Note the difference between instructions with a bit in positions 
1 and 2 and those without a bit in 1 or 2. Few instructions have a bit in positions 1 or 2. 

When the instruction is decoded the computer will decide what kind of a cycle is to be 
taken. Most instructions requiring an L cycle have operation codes 0-177 or from 700 
on. Instructions with operation codes between these limits usually require an E cycle. 
The exceptions to these general L and E time call rules are in the MF systems pages. 

Some instructions require only one cycle; therefore, the end operation trigger is 
turned on during I time. This forces "go to I time" on Systems 8. 00. 12. 1. "Go to I 
time" will turn on the master I time trigger and will prevent turning on of the master 
E or L time triggers. 

The program counter is advanced to give the location of the next sequential instruc- 
tion in core storage. The address portion of the instruction is sent to the address 
register. For primary operations 76 it is sent to the shift counter. The address in 
the address register is used to locate a particular address in storage if the next cycle 
is an E cycle. Part of the address is sent to the shift counter on primary operations 
76. The shift counter is used on these operations along with the program register to 
instruct the system. 

5.2.00 INDIRECT ADDRESSING 

Indirect addressing is a programming device which permits changing an instruction 
addresSo Bits in positions 12 and 13 of an instruction are signals for indirect address- 
ing. This causes an E cycle, during which the word located at the original instruction 
address is read out of storage and its address portion is substituted for the instruction 
address. The instruction then operates on the new address. Only indexable instruc- 
tions may be indirectly addressed. The only change in operation of an instruction 
caused by indirect addressing is the insertion of an E cycle. As with direct address 
instructions, indexing is automatic. 



45 



End Operation 
Tgr A 10- 16 

8.00.09.01 




Yes 



Go to 1 Time 

A10-M9 

8.00.12.1 




PC -*AS 

A9 (D3) 

3.05.09.1 


1 




** 


Mst 1 Time Tgr 




AS -*AR 


All -*-All 




All (Dl) 


8.00.18.01 




3.06.18.1 



AR 



• MAR 



AR -*-PC 

13 (Dl) 

3.06.05.1 



AD (3-17)-* 
AS A9(D3) 

3.06.16.1 




SB-^SR 

17 (Dl) 



2.12.50.1 



Reset PR and 
SC 17 (Dl) 



2.1 1 .40.01 




SB (S, 3-11) -*■ 
PR (S, 1-9) 
17 (D2) 
2.11 .40.1 



SB (S, 1, 2) 

-^PR(S, 8, 9) 

17 (D2) 
2.11 .40.1 



PR (1-5) 
— »-POD 

3.01 .00.- 



PR (6-9) 
— »- SOD 

3.07.00.- 



Reset Tag 
Reg 17 (Dl) 

2.08.01 .1 



Set Tag 
Reg 18 (D2) 

2.08.01 .1 



Yes 



IA 
Cycle 



\200-677>^ 










LTime 


Call 




19 (D3) 




8.00. 


16.1 



Not L Time 
Call 

8.00.16.1 



1 








Go to L Time 




G o to E Time 


19 (D3) 




19- 


A7 


8.00. 


12.1 




8.00. 12. 1 



Address 
Modification 



SR (18-35) 
AD(P-17) 
19 (D3) 

2.12.16.1 



Advance 
PC 19 (Dl) 



2.11.51 




Yes 



AD (3-17) 
AS 19 (D3) 



3.06.16.01 




8.00.20. 



Next Machine Cycl 



FIGURE 5.1-1. INSTRUCTION CYCLE 



46 



Indirect addressing controls are shown in Figure 5.2-1. Once an indirect addressing 
condition is recognized, the IA control trigger is turned on to block normal operations 
and an E cycle is initiated. When the E cycle is completed, the trigger is turned off, 
and normal execution is resumed. 

5.3.00 INSTRUCTIONS 

5.3.01 Word Transmission Instructions* 

Word transmission instructions are necessary to move information into and out of 
the CPU. Factors must be brought in from core storage and results must be returned. 
Instructions are available to move parts of words or whole words to or from core stor- 
age. 

Store STO -t-0601 (I, E) Figure 5.3-1 

This instruction moves a full word to core storage. The contents of the AC(S,l-35) 
replace the contents of storage location X. The AC is unchanged,, The store prefix, 
decrement, tag, address, and MF store control lines are activated so a full word can 
be put into core storage. 

Store Logical Word SLW +0602 (I, E) Figure 5.3-1 

This instruction replaces the contents of storage location X with the contents of the 
AC(P-35). The AC is unchanged. Execution of this instruction is identical to that of 
store except for the routing of AC(P) to the storage register sign position. AC(P-35) 
is gated to SR(S-35) on Systems 2. 12. 02. 1. 

Store MQ STQ -0600 (I,E) Figure 5. 3-1 

The contents of core storage location X are replaced by the contents of the MQ(S, 1-35) 
register. The contents of the MQ are unchanged. This instruction operates similarly 
to store, except that the word sent to the SR comes from the MQ rather than from the 
AC. 

Store Zero STZ +0600(1, E) Figure 5.3-1 

This instruction causes zeros to be placed in all positions of storage location X. 
The operation of this instruction is similar to store, except that nothing is put on the 
SB. Therefore, when the storage bus is gated to core storage, zeros are put into that 
location of storage. 

Store Prefix STP +0630 (I, E) Figure 5.3-2 

This instruction places the contents of AC positions (P, 1 and 2) into core storage 
location X, positions (S, 1 and 2). The contents of the AC and storage positions ( 3 
through 35) are unchanged. MF store prefix and MF store control are activated to cause 
core storage to store what is on SB(S, 1 and 2). To get the information to the storage 
bus, it must be moved from the accumulator to the SR. 

♦See Store Location and Trap, and Figure 5. 3-34. 



47 



I Time of IA 
Type Instruc- 
tion 



Address 
Modification 
XR Adders 
2.12.19.1 



AD (3-17) _, 
AS I9 D3 

3.06.16.1 



SR (18-35) 
AD (P-17) 



2.12.16.1 




End 
Op On 



Yes 



Yes 



No 




Sue 
TRA or XECT 



AS — » 
111 Dl 



AR 



3.06.18.1 



No 






' ._ 


1 




Address 




SR (18-35) 


Modifica- 




—►AD (P-17) 


tion 






(2.12.16.1) 








Yes 



No 



Yes 




Turn on IA Tgr 


I9D1 




2.10.65.1 



2.01 .12.1 




AD(3-17)-» 
E9 D3 

3.06.16.1 



-AS 



Yes 



Turn off IA Tgr 
E ll D l 
2.10.65.1 




IA? 



AS -1- 
Ell Dl 


>■ AR 


3.06 


.18.1 




-< 


1 




Next Cycle 
Determined by 
Instruction 



FIGURE 5.2-1 . INDIRECT ADDRESSING 



48 



I Time 
Pri Op 60 



SLW 



AC (p-35) 
SR (S-35) 
El (Dl) 
2.12.02.1 




Inst 



Store Ctrl 
2.09.00.1 



E Time 



MF Store Ctrl 
2.09.00.1 




STQ 



AC(S,l-35) 
->SR 
E1(D1) 
2.12.01 .1 



X 



MQ(S-35) 
-►SR 
E1(D1) 
2.12.07.1 



SR SB 
E4(D3) 

2.09.00.1 



MF Store 
Prefix 



2.09.01 .1 



MF Store 
Deer 

2.09.01 .1 



MF Store 
Tag 

2.09.01 



MF Store 
Address 

2.09.01 . 



SB ->■ Memory 
Data Reg 



End Op 



FIGURE 5.3-1 . STO + 0601; STQ - 0600; STZ + 0600; SLW + 602 



Store Decrement 



STD +0622 (I, E) 



Figure 5. 3-2 



The contents of AC(3-17) replace the contents of positions (3-17) of core storage lo- 
cation X. The remaining storage positions are unchanged, and the AC is unchanged. 
This instruction operates similarly to store prefix, except that MF store decrement 
rather than MF store prefix is made active. 

Store Tag STT +0625 (I, E) Figure 5.3-2 

The contents of AC(18-20) replace the contents of positions (18-20) of core storage 
location X. The AC and the remaining positions of core storage are unchanged. This 
instruction operates similarly to store prefix, except that MF store tag rather than 
MF store prefix is made active. 

Store Address STA +0621 (I, E) Figure 5.3-2 

The contents of AC(21-35) replace the contents of positions (21-35) of core storage 
location X. The remaining positions of storage and the contents of the AC are un- 
changed. This instruction also operates similarly to store prefix, except that MF store 
address rather than MF store prefix is made active. 

Store Left Half MQ SLQ -0620 (I, E) Figure 5.3-3 

The contents of positions (S-17) of the MQ replace the contents of positions (S-17) of 
storage location X. The remaining storage positions and the contents of the MQ are 
unchanged. MF store prefix, MF store decrement, and MF store control lines are 
activated so SB(S-17) can be read into storage. The word is sent from the MQ to the 
SR so it can be put on the SB. 

Store Instruction Location Counter STL -0625 (I, E) Figure 5.3-4 

The contents of the program counter, which contains the location of the STL instruc- 
tion plus one, replace the contents of positions (21-35) of storage location X. The 
contents of the PC and the remaining positions of storage are unchanged. The MF store 
address and MF store control lines are activated so the address portion of the storage 
word can be changed. The PC contents are sent to core storage on the SB. The con- 
tents of the PC are sent to the SR through the AS and the output of the SR feeds the SB. 

Load MQ LDQ +0560 (I, E) Figure 5.3-5 

The contents of the MQ are replaced by the contents of storage location X. The 
storage word is put into the SR, and the output of the SR is sent to the MQ. 

Exchange AC and MQ XCA +0131 (I) Figure 5.3-6 

The contents of the AC(S,l-35) are interchanged with the contents of the MQ(S,l-35). 
AC positions Q and P are reset. The SR is used for temporary storage while routing the 
MQ to the AC. 

Exchange Logical Accumulator and MQ XCL -0130(1) Figure 5.3-7 

This instruction interchanges the contents of AC(P-35) and the contents of the MQ 
(S-35). Positions (S) and (Q) of the AC are cleared. Execution is identical to that of 
XCA except for the handling of AC positions (S) and (P). The contents of the MQ are 
put into the SR. The contents of the SR(S, 1-35) and the AC (P,l-35) are interchanged, 
putting the original MQ in the AC. Gating the output of the SR(S, 1-35) to the MQ(S, 1-35) 
places the original AC contents in the MQ. AC positions (Q) and (S) are cleared because 
of normal shift cell operations. 

50 



I Time 
Pri Op 62 
3.01.11.1 




FIGURE 5.3-2. STP +0630; STD +0622; STT +0625; STA +0621 



I Time 
Pri Op 62 



E Time 



MF Store 
Ctrl 

2.09.00.1 

r 

MQ(S-35) 
-*SR E1(D1) 
2.12.07.1 
I 

SR-*SB 

E4(D3) 
2.09.00.1 



MF Store 
Prefix 
2.09.01 .1 



MF Store 
Deer 

2.09.01 .1 



/Pref and Decn 
Portion of SB-» 

Memory 
V Data Reg y 



End Op 



I Time 
Pri Op 62 



E Time 



MF Store 
Ctrl 

2.09.00.1 



PC-*-AS 

E0(D3) 
3.05.09.1 



T 



AS->SR(21- 
35) E2(D2) 

3.06.12.1 



SR-»-SB 

E4(D3) 
2.09.00.1 



'Adr Portion 
of SB ->-Mem 

Data Reg 



MF Store 
Address 
2.09.01 . 



End Op 



FIGURE 5.3-3. SLQ - 0620 



FIGURE 5.3-4. STL -0625 



I Time 
Pri Op 12 



1 Time 
Pri Op 56 






E Time 







SB->SR E7(D1) 
2.12.50.1 



MQ -kSR 

I10(D1) 

2.12.07.1 






End Op 







I Time 
Next Inst 



E End Op 
8.00.00.1 



SR(l-35)- 
I0(D3) 

2.12.14.1 



►AD 



1 Time 
Next 


nst 






SR(S-35) 
->MQ I3(D1) 

2,12-40.1 



SR(S) -*AC(S) 
12 (Dl) 

2.12.37.1 



AC(S,1 


-35) 


-►SR I2(D1) 


2.12. 


01 .1 



SR (S-35) -► 
MQ I3(D1) 

2.12.40.1 



AD(Q-35) 
-►AC I2(D1) 

2.12.31 .1 

_J 



FIGURE 5.3-5. LDQ +0560 



FIGURE 5.3-6. XCA +0131 



I Time 
Pri Op 12 



MQ -vSR 

I10(D1) 

2.12.07.1 



End Op 



I Time 
Next Inst 



SR (S-35)-*AD 
(P-35) 10 (D6) 

2.12.15.1 



AD (Q-35) -i 
AC 12 (Dl) 

2.12.31 .1 



AC(P-35)-*SR 
(S-35) 12 (Dl) 

2.12.02.1 



SR (S-35) 
MQ 13 (Dl) 

2.12.40.1 



Set AC(S)(Plus) 
1 6 (Dl) 
2.12.92.1 



I Time 
Pri Op 76 



L Time 



End Op 



I Time 
Next Inst 



Op K-+-SR 
12 (Dl) 

4.20.14.1 



SR-fc-MQ 

I5(D1) 
2.12.40.1 



FIGURE 5.3-7. XCL -0130 



FIGURE 5.3-8. ENK +0760. . .0004 



Enter Keys 



ENK +0760. . . 0004 (I,L) 



Figure 5. 3-8 



The word represented in console keys (S, 1-35) replaces the contents of the MQ. This 
is a primary operation 76 instruction. The word in the keys is put into the SR and the 
output of the SR is gated into the MQ. 

5. 3. 02 Shifting Instructions 

Shift instructions are used to align words, or for fast multiplication or division by a 
power of 2. Shifting moves the bits of the AC or MQ, or both, to the right or left within 
the registers. Bits shifted out of the end of a register are lost and bits shifted away 
from either end of a register are replaced by zeros. Because the shift counter receives 
only the last eight positions of the instruction address, the maximum number of shifts 
possible is 255io (11 HI Hl2). 

The number of shifts to be taken is indicated by the address portion of the shift in- 
struction. This address is gated to the shift counter at Ill(Dl). Shifting starts at the 
next LI time and continues to shift at the rate of one position of shift for each clock 
pulse until the shift counter has been reduced to zero. 

The cyclic makeup of a shifting instruction is an I time followed with as many L times 
as required to complete the shifts designated by the address portion of the instruction. 
Eleven shifts may be completed during the first L time, and twelve shifts may be com- 
pleted during all succeeding L times. The "end operation" condition is signaled by 
having the shift counter at seven or less at any L10 time of a shift instruction. This 
means that up to five shifts may be made in the I time of the following instruction. 

Shifting to the left is the same as multiplying by a power of 2; shifting to the right 
reduces or divides by a power of 2. The number of shifts is equal to the exponent. 

Accumulator Left Shift ALS +0767 (I, L. . . ) Figure 5.3-9 

This instruction causes the contents of the AC (Q-35)* to be shifted left a number of 
places equal to the eight low order positions of the address. Zeros replace any bits 
shifted away from position (35). Bits shifted past Q are lost. A "1" shifted into the P 
position turns on the AC overflow indicator. 

Long Left Shift LLS +0763 (I, L. . . ) Figure 5. 3-10 

For this instruction the contents of the MQ and AC (except the sign positions) are 
shifted left the number of places designated by the eight low order positions of the ad- 
dress. The MQ (1) position is shifted to the AC (35) position. The AC sign is set to 
agree with the MQ sign. Bits shifted past Q are lost and bits shifted away from MQ(35) 
are replaced by zeros. Bits shifted into P cause the AC overflow indicator to be turned 
on. 

Logical Left Shift LGL -0763 (I, L. . .) Figure 5.3-10 

This instruction shifts the contents of AC(Q-35) and MQ(S-35) left the number of 
places designated by the address. Bits shifted from MQ(1) enter MQ(S), and from MQ 
(S) enter AC (35). Bits shifted into AC(P) cause the AC overflow indicator to be turned 
on. Bits shifted past AC(Q) are lost and bits shifted away from MQ(35) are replaced by 
zeros. The operation of LGL is similar to LLS except for handling of the MQ sign. 



* This text section uses (Q - 35) to represent (Q,P, 1 - 35). 



53 




Yes 



Step SC Each 
Clock Pulse 

2.11.79.1 



Shift Gate LI to 
SC = 0 



2.11.79.1 



ALS Ctrl 
2.09.70.1 



Set and Shift 
AC Lt 

2.12.34.1 



/ SC Stepped and 
( AC Shifted Every 
V Clock Pulse 




Turn On AC 
Ov Tgr 

2.10.36.1 



L End Op 
A10(D1) 

8.00.01 .1 



FIGURE 5.3-9. ALS +0767 



I Time 
Pri Op 76 



AS(10-17) -*SC 
111 (Dl) 

2.11,78.1 



L Time 




Yes 



L End Op 
A10 (Dl) 

8.00.01 .1 




Inst 



2.11 .79.1 





Set 

MQ(S) -»AC(S) 
2.12.42.1 



Turn On AC 
Ov Tgr 

2.10.36.1 



Step SC Each 
Clock Pulse 
2.11 .79.1 



Set and Shift AC 
(P-35) and MQ 
(2-35) Lt 

2.12.34.1 

2.12.42.1 



MQ(1)-*AC(35) 
2.12.42.1 



LGL 



MQ(1)-*MQ(S) 
2.12.42.1 



MQ(S)- 
(35) 

2.12.42.1 



AC 



SC Stepped and 
AC-MQ Shifted 
\Every Clock Pulse 



FIGURE 5.3-10. LLS+0763; LGL -0763 



Accumulator Right Shift ARS +0771 (I, L. . . ) Figure 5. 3-11 



This instruction causes the contents of AC (Q-35) to be shifted right the number of 
places indicated by the address. Bits shifted away from Q are replaced by zeros; bits 
shifted past position (35) are lost. ARS is similar to ALS except for direction of the 
shifting. 



Long Right Shift LRS +0765 (I, L. . . ) Figure 5. 3-12 

The contents of the MQ and AC (except the sign positions) are shifted right the 
number of places indicated by the address. The MQ sign is set to agree with the AC 
sign. Bits shifted away from Q are replaced by zeros and shifted past AC (35) enter 
MQ(1). Bits shifted past MQ(35) are lost. 



Logical Right Shift LGR -0765 (I, L. . . ) Figure 5. 3-12 

This instruction shifts the contents of the AC(Q-35) and MQ(S-35) right the number 
of places designated by the address. Bits shifted out of AC(35) are entered into MQ(S) 
and from MQ(S) to MQ(1). Bits shifted past MQ(35) are lost. The operation of LGR is 
the same as LRS except for the handling of the MQ sign. 

Rotate MQ Left RQL -0773 (I, L. . .) Figure 5. 3-13 

This instruction shifts the contents of the MQ, including the sign, left the number 
of places designated by the address. Bits shifted out of MQ(1) enter the sign position 
and from the sign position enter MQ(35). 



5. 3. 03 Fixed-Point Arithmetic Instructions 

Fixed-point arithmetic instructions are the basic calculating instructions. Addition 
is the foundation of all of these instructions, and parts of the ADD instruction will be 
found in all instructions. All arithmetic instructions use the accumulator. 



Clear and Add CLA +0500 (I,E) Figure 5.3-14 

The instruction clears the AC (S, Q-35) and loads positions (S, 1-35) with the con- 
tents of the storage location indicated by the address. The word that is to be put into 
the AC is brought from core storage to the SR during the E cycle. In the I cycle of the 
next instruction, positions (1-35) are gated from the SR through the AD to the AC. The 
sign position is gated directly from the SR to the AC. 



Clear and Subtract CLS +0502 (I,E) Figure 5.3-14 

This instruction replaces the contents of the AC with the word from the core storage 
location indicated by the address. The sign of the word is reversed. Execution of this 
instruction is the same as the CLA except that the sign of the word is inverted during 
the E cycle after the word has entered the SR. 



55 



I Time 
Pri Op 7 6 

I 

AS(10-17)*SC 
111 (Dl) 

2.11.78.1 



L Time 




No 



Shift Gate 
LI to SC = 0 

2.11 .79.1 



ARS Ctrl 
2.09.70.1 



Set and Shift 
AC RT 

2.12.33.1 



Step SC Each 
Clock Pulse 

2.11.79.1 



SC Stepped and 
AC Shifted Every 
Clock Pulse 



L End Op 
A10(D1) 
8.00.01 .1 



FIGURE 5.3-11. ARS +0771 



I Time 
Pri Op 7 6 



AS(10-17)*SC 
lll(Dl) 
2.11 .78.1 

I 




Shift Gate 
LI to SC = 0 



Step SC Each 
Clock Pulse 
2.11 .79.1 


Set and Shift 

AC(Q-34) 

and MQ(l-34) RT 

2.12.33.1 

2.12.43.1 




1 



1 












AC(S)-*MQ(S) 
2.12.33. 1 


AC(35)-*MQ(1) 
2. 12.33.1 


AC(35)*-MQ(S) 
2.12.33.1 


MQ(S)-*MQ(1) 
2.12.43.1 















SC Stepped and 
AC-MQ Shifted 
Every Clock 
Pulse 



FIGURE 5.3-12. LRS +0765; LGR -0765 



I Time 
Pri Op 76 
Sec Op 13 

AS(10-17)-*SC 
I 11(D1) 

2.11 .78.1 
P 

L Time 




~5 




2.11.79.1 



RQL Ctrl 
2.09.70.1 



MQ(1) 


Set and 


-*MQ(S) 


Shift MQLt 


2.12.42.1 


2.12.42.1 



MQ(S) 
-*MQ(35) 
2.12.42.1 



Step SC Each 
Clock Pulse 
2.12.42.1 



L End Op 
A10(D1) 
8.00.01 .1 



SC Stepped and 
MQ Shifted 
, Every Clock Pulse, 



FIGURE 5.3-13. RQL -0773 



I Time 
Pri Op 50 

E Time 



SB-vSR 

E7(D1) 
2.12.50.1 




Change SR (S) 
E9(D1) 

2.09.95.1 
— H 



End Op 



I Time 
Next Inst 



SR(l-35)-*AD 
10 D3) 




SR (S-35) AD 
AD(P-35) 
10 (D6) 
2.12.15.1 



2.12. 



SR(S) -*-AC(S) 
12 (Dl) 

2.12.37.1 



V 

AD(Q-35)-*AC 
12 (Dl) 
2.12.31 .1 



Set AC (S) (Plus) 
16 (Dl) 

2.12.92.1 



FIGURE 5.3-14. C LA +0500; CLS +0502; CAL-0500 



Clear and Add Logical Word 



CAL -0500 (I, E) 



Figure 5.3-14 



This instruction clears the AC(S,Q, P, 1-35) and enters the word stored at the location 
indicated by the address into AC (P, 1-35). This instruction operates the same as CLA 
except that the (S) of the word is sent to AC(P). The sign of the word in the AC is positive. 

Add ADD 4-0400 (I, E) Figure 5.3-15 

This instruction causes the word, stored at the location indicated by the address, to 
be added algebraically to the contents of the AC. The resulting sum or difference re- 
places the AC factor. 

The following rules of addition are used during the execution of the add instruction: 

1. Accumulator and storage register signs alike: 

a. Add true accumulator factor to the storage register factor. 

b. The accumulator sign is unchanged. 

2. Accumulator and storage register signs unlike: 

a. Add l's complement of the accumulator factor to the storage register 
factor. 

(1) If no end-carry results, complement the accumulator factor and 
leave the accumulator sign unchanged. 

(2) If an end-carry results, add one to the result and change the 
accumulator sign. 

Except for bringing a word from storage to the SR, most of the execution of this 
instruction is accomplished during the I cycle of the next instruction. The contents of 
the AC or the l's complement of the AC and the contents of the SR are added in the 
adders. Whether to use true AC or complemented AC is determined by the comparison 
between the AC and SR signs. Complement addition is used to obtain the difference be- 
tween the contents of the SR and the contents of the AC. 

The difference between the SR and AC contents can be a complement number or a 
true number. The result will be in complement form if the AC is larger than the SR 
factor. A true number will result if the AC factor is smaller than the SR factor. Dur- 
ing the addition a carry out of AD position Q indicates that the AC factor is smallerand 
no Q carry indicates that the AC factor is larger. To remember the carry, a Q carry 
trigger is turned on by a carry out of AD position (Q). 

If the result of the complement addition is a true number it is one less than it should 
be because the l's complement rather than the 2's complement was used in the addition. 
Therefore, a one is added to the result in the AC to get the correct difference. If the 
result of the addition is a complement number, it must be re-complemented to get the 
correct true number. The sign of the result in the AC is set the same as the sign of 
the largest original factor, as determined by the status of the Q carry. 

Example 1 
Signs Alike 

-7 + (-6) = -13 
-0111 SR(7) 
-QUO AC (6) 
-1101 Result in AC (13) 



58 



SUB 



Invert SR (S) 
E9(D1) 

2.09.95.1 



Inst 



SUB, SBM 




SBM 



Set SR(S) Minus 
E9(D1) 
2.09.95.1 



I Time 
Pri Op 40 



E Ti; 



SB-*SR 
E7(D1) 
2.12.50.1 




Inst 



ADD, ADM 



ADM 




Set SR(S) Plus 

E9(D1) 

2.09.95.1 



Inst 



ADD 



Alike 



Unlike 





- 2.12.94.1 




~t r- 








SR+AD 
10 (D3) 
2.12.14.1 




Comp AC (Q-35] 
♦AD IO (D3) 

2.12.22.1 








FIGURE 5.3-15. ADD +0400; ADM +0401; SUB +0402; SBM -0400 



59 



Example 2 

Signs Unlike, AC Smaller 

7 + (-6) = + 1 
+0111 SR(7) 

-1001 l's comp of AC (6) 
-0000 Q carry 

1 Add one 

-0001 Result in AC 
-1-0001 Change sign 

Add Magnitude 



Example 3 

Signs Unlike, AC Greater 

6 + (-7) = -1 
+0110 SR(6) 

-1000 l's comp of AC(7) 



-1110 No Q carry, Result in AC 
-0001 Comp AC 



ADM +0401 (I,E) 



Figure 5.3-15 



For this instruction, the word at the storage location indicated by the address is to 
be considered positive. This positive word is added, algebraically, to the contents of 
the AC. ADM operates the same as ADD, except that the sign of the word is set posi- 
tive after it has entered the SR. 



Subtract 



SUB +0402 (I,E) 



Figure 5.3-15 



This instruction algebraically subtracts the word at the storage location indicated by 
the address from the contents of the AC. The execution of SUB is similar to ADD, 
except that the sign of the word in the SR is inverted. 



Subtract Magnitude 



SBM -0400 (I,E) 



Figure 5.3-15 



For this instruction the sign of the storage word indicated by the address is considered 
negative. This negative word is added algebraically to the contents of the AC. The 
execution of SBM is the same as ADD, except that the sign of the SR word is forced 
negative. 



Add and Carry Logical Word 



ACL +0361 (I, E) 



Figure 5.3-16 



This instruction adds the 36-bit logical word stored at the location indicated by the 
address to the contents of the AC(P-35). AC(S) is ignored; AC(Q) is unchanged. A 
carry out of AD(P) is added to position 35 in the adders. The operation of this instruc- 
tion is the same as ADD, except for the handling of the (S), (Q), and (P) positions. 



Multiply 



Figure 5.3-17 



MPY +0200 (Min I,E) 

(Max I,E, 12L) 

This instruction multiplies the word stored at the location indicated by the address 
by the contents of the MQ. The 35 most significant bits of the 70-bit product replace 
the AC(l-35), and the 35 least significant bits replace the MQ(l-35). Positions (Q) 
and (P) of the accumulator are cleared, and the signs of the AC and MQ are set to the 
algebraic sign of the product. 



00 0110 Multiplicand (SR) 

1011 Multiplier (MQ) 

0110 Partial Product 
0110 " " 
0000 " " 

0110 " " 



1000010 Product (AC and MQ) 



60 



I Time 
Pri Op 36 



E Tir 



SB -►SR 

E7(D1) 
2.12.50.1 



End Op 



I Time 
Next Inst 



ACC (Q) — *> 
SR (9) I2(D1) 

2.12.01.1 



SR(S-35)+AD 
(P-35)I0 (D6) 
2.12.15.1 



AC(Q-35)*AD 
(Q-35)I0(D6) 
2.12.24.1 




kD P Can? 



Yes 



No 



SR (Q) — »- 
ACC(Q) I5(D1) 
2.12.38.1 



Carry — 
AD(35) 
2.12.29.1 



AD(P-35)- 
15 (Dl) 



►AC 



2.12.30.1 



1 Time 
Pri Op 20 






E Ti 


me 




MQ & SR 
Signs Alike 

2.12.94.1 



Set MQ & AC 
Signs Plus 
El 1 (Dl ) 
2.12.92.1 



2.12.52.1 



Clear MQ 1-35 
El 1 (Dl ) 

2.15 .18.1 



L Tin 



End Op in 
E Control 

2.09.46.1 



MQ & 
Signs I 

2.12. 


, SR 
'nl ike 

?4.1 






Set MQ & AC 
Signs Minus 

E 1 1 (Dl) 
2.12.92.1 



SR-*AD 
All L Time 

2.12.14.1 



Add cycle MPY, 
MPR, VLM L0(D3) 
L4(D3), L8(D3) 
2.09.54.1 




AC-* 
"L Tin 
2.12.; 


-AD 
ne" 

24.1 




-<- 




AD- 
L2(D1), 
L10( 
2.12. 


*AC 

L6(D1) 
Dl) 
31 .1 



Yes 



MQ(34)=1 



No 




Shift MQ & AC 
Rt L3(D1) L7(D) 
LI 1 (Dl ) 

2.09.54.1" 



Shift MQ & AC 
Right Every Clock 
Pulse After 1st L0 
2.09.54.1 



Shift MQ & 
AC Right 1st 
L0 

2.09.54.1 



Step SC 


2.11.79.1 






< 


> 




Yes 


End Op 


L Control 


2.09.43.1 







No 



I Time 
Next 
Instruction 



FIGURE 5.3-16. ACL +0361 



FIGURE 5.3-17. MULTIPLY +0200 



In the 7090, multiplication follows this procedure closely. Starting at the right of the 
multiplier in the MQ, only one position of the multiplier is scanned at a time. In the 
7090 there is no means of remembering partial products so they may be added alter 
each position of the multiplier has been used. Therefore, if the multiplier position be- 
ing scanned is a one, the multiplicand is added to any previous partial product that is in 
the AC. In the 7090, multiplication is done as follows: 



0110 Multiplicand (SR) 

1011 Multiplier (MQ) 

0000 Start with zeros in AC 

+0110 Right MQ position scanned 

0110 Partial Product 

+0110 Next MQ position scanned 

10010 Partial Product 

0000 Next MQ positions scanned 

010010 Partial Product 

+0110 Next MQ position scanned 

1000010 Product (AC and MQ) 



In this example, each time the multiplicand is added to the previous partial product, 
the multiplicand must be moved to the left to correctly line up the bit positions. In the 
7090, the partial product is moved to the right rather than the multiplicand moving to 
the left. The end result is the same. 



Multiplication in the 7090 breaks to two major procedures: 

1. Addition of SR and AC contents. 

2. Shifting the contents of the AC and MQ right. 

Figure 5. 3-17 shows a MPY operation in the 7090. During the E cycle, in addition 
to bringing the multiplicand to the SR, the AC is cleared and the sign is set. This 
allows the MPY to start with the AC containing zeros. Also during the E cycle the word 
coming from storage is tested to see if all positions contain a zero. If the multiplicand 
is zero the product is to be zero. To save machine time, the MQ is cleared and the 
instruction ends operation; 43s (35io) is P u t into the SC. The SC will be used to indi- 
cate when all bits of the MQ have been tested. Also, because the storage word was not 
zero, the computer is put into L time for multiplication. 

Now MQ(35) is tested for a bit. If there is a bit in MQ(35), the SR and AC contents 
are added and the result is put into the AC. If MQ(35) had no bit, this addition would 
not have been done because the sum of zero and a number equals the same number. The 
AC and MQ are shifted right to put the next position of the multiplier in MQ(35) to be 
tested, and put the partial product in correct alignment with the multiplicand. This 
type of shift is called a slow-speed shift. High-speed shifting (shifting once for each 
clock time) will occur if MQ(34) contains zero. This is done to speed the multiplica- 
tion operation. Each time the AC and MQ are shifted, the shift counter is stepped and, 
as long as the shift counter does not equal zero, MQ(34) is once more tested and the 
process starts again. When the SC has been stepped down to zero, the computer signals 
that multiplication is complete. Because all positions of the multiplier have been 
scanned and all additions have been completed, MPY then ends operation. 



62 



Note that three additions can be done during each cycle of MPY. The maximum num- 
ber of shifts during an L cycle can be 12, depending on positions (34) and (35) of the MQ. 
Maximum number of machine cycles required for MPY is 14; minimum is two. 

Multiply and Round MPR -0200 (Min I,E) Figure 5.3-18 

(Max I,E, 12L) 

This instruction executes a multiplication followed by rounding the AC contents. The 
multiplication is identical to MPY* the rounding is accomplished by adding one to AC 
(35) if MQ(1) contains a one. 

Variable-Length Multiply VLM +0204 (Min I, E) Figure 5.3-19 

(Max I,E, 12L) 

This instruction operates much the same as MPY, except that the number of multi- 
plier positions to be tested is specified by a number in the decrement portion of the instruc- 
tion. The difference between MPY and VLM occurs in the E cycle. A count from the 
decrement portion of the instruction is put into the SC rather than 43s. Usually this 
count will be less than 43s. A count of 60g or greater will cause an I/A cycle, and the 
count field (12-17) will OR with 12-17 of the IA word. 

Divide or Halt DVH +0220 (Min I,E,L) Figure 5.3-20 

(Max I,E, 12L) 

This instruction divides the contents of the AC and MQ, taken together as the dividend, 
by the word stored at the location specified by the address. A 35-position quotient is 
developed in the MQ, and the remainder of the dividend is left in the AC. The sign of 
the MQ is set to the algebraic sign of the quotient, as determined by the SR and AC 
signs. The sign of the remainder remains the same as the sign of the dividend. The 
size of the registers restricts the size of the factors to be divided. If the AC portion 
of the dividend were greater than or equal to the divisor, the quotient would be too large 
for the MQ. In this case, division cannot take place, and the computer is stopped with 
the divide check indicator on. 

The following demonstrates binary division: 
QUO Quotient (MQ) 
1011 J 1000010 Dividend (AC and MQ) 
1011 
01011 
1011 
00000 
0000 

0000 Remainder (AC) 

Note that the divisor will go once or not at all into the high order positions of the 
dividend. Therefore, it is only necessary to determine if the divisor is equal to or 
smaller than these positions of the dividend. If the divisor is equal to or smaller than 
the selected positions of the dividend, a one is put in the quotient and the divisor is 
subtracted from that portion of the dividend. If the divisor is larger than the selected 
portion of the dividend, a zero remains in the quotient. Another position of the dividend 
is now taken into account, and the procedure starts again. This continues until all posi- 
tions in the dividend have been used. 

In the 7090, the SR and AC are complement added to determine if a reduction of the 
high order positions of the dividend is possible. If the reduction is possible, these 



63 



I Time 
Next Inst 



AC(Q-35) ->AD 


10 (D3) 




2.12.24 


.1 




MQl = i ^-tJa- 

Yes 



Carry ->AD(35) 
10 (D3) 

2.12.29.1 



AD(Q-35)-> 
12 (Dl) 

2.12.31 .1 



►AC 



Operates the Same as MPY, Except 
that the Above is also Done During 
the I Cycle after,MPY. 



FIGURE 5.3-18. MPR - 0200 



E Time 



SR(S,l-35)-*AD 
(P-35) E0(D3) 

2.12.15.1 



AD(3-17) ->AS 
E2(D1) 

3.06.16.1 



AS(12-17)->SC 

E2(D1) 

2.11 .78.1 



Prevent 43g- 
SC E3(D1) 

2.11.78.1 



Operates the Same as MPY, Except 
that the Above is also Done During 
the E Cycle. 



FIGURE 5.3-19. VLM + 0204 



64 



I Time 
Pri Op 22 



AD-»AC 
E6(D1) 

2.12.31 .1 



SB— -*SR 
E7(D1) 

2.12.50.1 



SR_w\D 
E8(D3) 

2.12.14.1 



AC — *-AD 

E8(D3) 

2.12.24.1 
\ 









Comp AC-»-AD 




E4(D3) 






2.12.22.1 





VDH, VDP 



DVH 
DVP 



SR(S,l-35) 
-*AD(P-35) 

E0(D3) 

2.12.15.1 



AD(3-17) ■ 
E2(D1) 

3.06.16.1 



-AS 



AS(12-17) 
-*-SC E2(D1) 

2.11 .78.1 




SC = 0 



Yes 



No 



43 8 — SC 
E3 (Dl) 
2.11 .78.1 



(SR^AC) 



No 





Q Carry 



Yes (SR> AC) 



1 I 



Q Carry 

and 
SC=0 



Div Shift 
Ell(Dl) 

2.09.50.1 

T 



Div sh;rt 

Ctrl 
2.09.51 .1 



Comp MQ1 
-*-AC(35) 

2.12.42.1 









E End Op 







To End Op 
Figure 
3.5-20B 



f 



Sh AC (P-35) 

and MQ (2-35) Lt 
2.12.34.1 
2.12.42.1 



1 



SR & ACC 
Signs Unlike 
2.12.94.1 



Set MQ Sign 
Minus El 1 
2.09.51.1 



SR & ACC 
Signs Alike 
2.12.94.1 

I 

Set MQ Sign 
Plus Ell 
2.09.51 .1 



MPY - Div 
Step SC 
2.11 .79.1 

ZZT" 



I To L Time \ 
Figure 3.5-20B] 



FIGURE 5. 3-20A. DVH +0220; DVP +0221; VDH +0224; VDP +0225 



65 




l-*-MQ(35)L2 
(D1),L6(D1) 
LlO(Dl) 
2.09.51 .1 



AD-»AC L2(D1) 
L6(D1), L10(D1) 

2.12.31 .1 



Yes 




SC = 0 



No 



Div Shift Ctrl 
L3(D1),L7(D1) 
LI HDT) 
2.09.51.1 



Comp MQ 1 " 
AC(35) 

2.12.42.1 



Sh AC(P-35) 

and MQ(2-35)Lt 
2.12.34.1 
2.12.42.1 



Mpy - Div 
End Op 
2.09.51.1 



-Div Step SC 
L3 (Dl), L7(D1) 
Lll (Dl) 
2.09.51.1 



Turn on Div 
Ck Tgr Ell 

2.10.53.1 

d 



Divide Ck 
End Op Ell 

2.09.50.1 



Turn On 
Tl - Ell 
2.10.53.1 



L Tii 




Off 



On 



Turn On Mst 
Stop Tgr I 5 

4.20.11 .1 



'?> Cycle Inter Al l\ 
8.00.13.1 Prevent) 
l,E and L Cycles / 



End Op 

~T~ 



I Time 
Next Inst 



DVH, VDH^ |nst 




DVP,VDP 



Comp A 
1 0 (D3 
2.12 


^C-*AD 
22.1 






AD -»-AC 
I2(D1) 

2.12.31.1 






Turn Off 
Tl I6(D1) 
2.10.53.1 



FIGURE 5.3-20B. DVH + 0220; DVP + 0221 ; VDH + 0224; VDP + 0225 



66 



positions of the dividend are reduced by the amount of the divisor and the difference is 
put into the AC. If a reduction is not possible the AC remains the same. A successful 
reduction causes a one to be put into MQ(35). After the reduction time, the AC and MQ 
are shifted left to bring the next position of the dividend into the AC and another reduc- 
tion is tried. This operation continues until all positions of the MQ portion of the divi- 
dend have been moved to the AC. 

Figure 5.3-20 shows the sequence of a DVH operation. Because subtraction in the 
7090 is accomplished through complement addition, the AC contents are put into comple- 
ment form early in the E cycle. This complement and the contents of the SR are added 
to determine if the quotient will be small enough for the MQ register. A Q carry indi- 
cates that division is possible and a no Q carry indicates that division is not possible. 
Also, during the E cycle, 43g is put into the SC and this will be used to indicate when 
all dividend positions have been used. 

When there is no Q carry as a result of the E cycle test, the divide check trigger is 
turned on and the computer is signalled to divide check end operation. An L cycle 
occurs before actual end operation because the divide check end operation signal comes 
too late in the E cycle. During the I cycle of the next instruction, the master stop trig- 
ger is turned on and this causes B cycle interrupt to be activated. B cycle interrupt 
prevents I, E, and L cycles. 

A Q carry as the result of the E cycle test allows normal divide operation to take 
place. Toward the end of the E cycle the AC and MQ are shifted left, the SC is stepped 
and the MQ sign is set. This brings the next position of the dividend into the AC. Note 
that while shifting from MQ(1) to AC (35), the information is complemented because a 
complement number is used in the AC. 

The computer then goes into L cycles 0 A reduction is attempted and a 1 is put into 
MQ(35) if the reduction is successful. Again there is a left shift of the AC and MQ and 
the SC is stepped. This attempted reduction and shifting procedure continues until the 
SC equals zero. When the SC=0, divide end operation is actuated. 

During the I cycle of the next instruction the AC is again complemented to make the 
remainder a true number. 



Divide or Proceed DVP +0221 (Min I,E, L) Figure 5.3-20 

(Max I,E, 12L) 

The execution of this instruction is identical to DVH except that the computer is not 
stopped for the divide check violation, but proceeds to the next instruction. The divide 
check trigger is not allowed to turn on the master stop trigger during the I cycle of the 
next instruction. 

Variable -Length Divide or Halt VDH +0224 (Min I, E) Figure 5. 3-20 

(Max I,E,12L) 

This instruction operates the same as DVH, except that the number of reductions to 
be taken is specified by the count in positions (12-17) of the instruction. The number of 
positions in the quotient is equal to the count and will be contained in the low-order 
positions of the MQ. The count should be restricted to a number between 0 and 433. A 
zero count ends operation in E time and prevents the shift at the end of the E cycle. A 



67 



count of 438 will give the same result as DVH. A count greater than 43s causes part of 
the quotient to be shifted into the AC , where it can be altered. A count of 60s or greater 
will cause an i/A cycle, and the count field (12-17) will OR with 12-17 of the IA word. 

Variable-Length Divide or Proceed VDP +0225 (Min I,E) Figure 5.3-20 

Max I.E.12L) 

The execution of this instruction is the same as VDH, except that the computer will 
not stop for a divide check, but will proceed to the next instruction. 

Round RND +0760. . . 0010 Figure 5. 3-21 

(I,L) 

This instruction examines the contents of MQ(1) and if it contains a one, the magni- 
tude of the AC is increased by one. If MQ(1) contains a zero, the AC is unchanged. The 
MQ is not changed in either case. AC overflow is possible. This is a primary opera- 
tion 76 instruction. The contents of the AC are sent to the AD and, if MQ(1) contains 
a one, a one is sent to AD(35) and the output of the AD replaces the contents of the AC. 

Clear Magnitude CLM +0760. . .0000 Figure 5.3-22 

(I, L) 

This instruction puts zeros in AC(Q-35). CLM is a primary operation 76 instruction. 
The operation is accomplished by gating the AD to the AC, with nothing in the adders. 
The AC(S) remains unchanged. 

Complement Magnitude COM +0760. . . 0006 Figure 5.3-22 

(I.L) 

The contents of the AC(Q-35) are complemented. Positions containing ones are 
changed to zeros and positions containing zeros are changed to ones. This instruction 
is executed by complementing the AC to the AD and replacing the contents of the AC 
with this complement. 

5.3.04 Floating-Point Arithmetic Instructions 

The range of numbers anticipated during a calculation may be extremely large, 
extremely small or, in some cases, unpredictable. Such situations make fixed-point 
arithmetic difficult to work with for two reasons; 

1. The size of the number is limited by the size of the register 
(35 binary bits or 10 decimal digits). 

2. The programmer must keep track of the point in all numbers throughout 
the calculation. 

To meet the needs of large numbers and to automatically keep track of the point, an 
alternative set of arithmetic instructions, called floating-point arithmetic instructions, 
are available. 

Floating-point arithmetic is merely arithmetic dealing with numbers in exponential 
form. The numbers 5.6 x 10 3 or 56000 x 10 " 4 have a familiar form. The numbers 
are made of three parts; a fraction (5. 6 or 56000), an exponent (3 or -4), and a base (10). 

Floating-point numbers in binary are similar to decimal floating-point numbers. 
The major difference is the base. Numbers in the 7090 use 2 as a base, because it is 
a binary computer. The other difference is one of terms. Instead of a decimal point, 
we will call it a binary point. 

The following chart gives a comparison of fixed -point binary numbers and floating- 
point binary. 



68 



I Time 
Pri Op 76 



AS00-17)-> 
SCI 11 (Dl) 
2.11 .78.1 



L Ti 



End Op 



X 



I Time 
Next Inst 



<J5 
CO 



AC(Q-35) -> 
ADI0(D3) 
2.12.24.1 



AD(Q-35) 
-»-AC I2(D1) 
2.12.31 .1 




2.10.36.1 



FIGURE 5.3-21. RND +0760. . .0010 



I Time 
Pri Op 76 

AS(10-17) 

*sci n(Di) 

2.11.78.1 



L Time 
End Op 



I Time 
Next Inst 



CLM 




Comp AC(Q-35) 
-►AD I0(D3) 



2.12.22.1 



AD(Q-35) 
-*-ACI2(Dl) 
2.12.31 .1 



FIGURE 5.3-22. CLM +0760. . .0000; COM +0760. . .0006 



Fixed-Point Binary Floating Point 

(4) 000100 1 x 2 011 

(11) 001001 :i001x2 100 



Because the 7090 works in binary, all floating-point numbers will be to the base 2. 
Therefore, to represent a floating-point number in the computer, there is no need to 
carry the base along with the number. This cuts our need to representing the fraction 
and the exponent. The exponent is represented in positions (1-8) of the word and is 
now called the characteristic. The fraction is contained in positions (9-35). The 
binary point is to the left of the 9 bit. The sign position is used to sign the fraction. 
Word layout takes this format: 

S l 8 .9 35 

Characteristic Fraction 

The value of the number in the characteristic field signifies the exponent and its 
sign. The characteristic is derived by adding 200g to the exponent. If the character- 
istic is 200g the exponent is zero. If the number is 201 to 377, the exponent is posi- 
tive. If it is 0 to 177, the exponent is negative. The following chart gives examples 
of exponential numbers and their floating point representation: 

Exponential Floating Point 

Binary S 1-8 9-35 

+ .lx 2 011 + 10000011 10000 0 

-. 01 x 2 001 - 10000001 0100 0 

+ . 1 x 2" 011 + 01111101 1000 0 

Normal and Unnormal Forms 

A floating-point number is said to be in normal form when the digit immediately to 
the right of the point is a significant bit (1). If the number is a zero, it is said to be in 
unnormal form. The exception to this rule is a normal zero: a normal zero is a 
floating-point number whose characteristic and fraction are both zero. 

To go along with the two types of numbers, the instructions are also divided into two 
categories, normal and unnormal. The difference in computer operation is that the 
normal instructions always attempt to produce a normal answer and the unnormal in- 
structions do not. 

Arithmetic of Floating Point 

Addition of floating-point numbers is done by adding the fractions of floating-point 
numbers which have equal characteristics. The characteristics are set equal pre- 
ceding the addition by placing the number with the smallest characteristic in the AC. 
The fraction is then shifted right, and for each right shift one is added to the character- 
istic. When the characteristic of the AC equals the characteristic of the SR, shifting 
stops, and the fractions of the AC and SR are added. Bits shifted out of AC (35) enter 
MQ(9). The sum appears in the AC and forms the most significant part of the answer. 
The least significant part is the bits that were shifted into the MQ. The MQ character- 
istic is set 27io less than the AC characteristic to complete an unnormalized floating 



70 



add. If it were a normalizing instruction, a check would be made to see if a 1 were in 
AC position nine. If AC(9) does contain a 1, the operation would be complete; if not , 
the AC would shift left until a one did appear in position nine. Shifting increases the 
number, so to keep it the same, the characteristic is reduced by the number of left 
shifts taken. Floating-point subtraction works the same except that the fractions are 
subtracted. 

Floating-point divide is accomplished by dividing the fraction of the dividend by the 
fraction of the divisor and subtracting the characteristics. During the subtraction of 
the characteristics, the 200g that is added to all exponents is lost. Therefore, before 
the answer is final, 200g must be added to the quotient characteristic. 

Floating multiply is accomplished by multiplying the fraction in the SR by the fraction 
in the MQ. The exponents in multiply are added, so in a floating multiply, the computer 
adds the characteristics. Because 200g had been added to each exponent originally, 
the characteristic is increased by 400g after the addition. Before the answer is final, 
200g must be subtracted from the characteristic. The most significant part of the prod- 
uct is in the AC and the least significant part in the MQ. 

Sign control is as follows: 

Multiplication and Division Signs of factors alike; answer plus 

Signs of factors unlike; answer minus 
Addition Answer always has sign of the largest factor 

Subtraction After sign of SR is inverted, answer always has 

sign of the largest factor 

Floating-Point Tally Counter 

The floating-point add, multiply, and divide type instructions require an I, an E, 
and several L cycles. Execution of the instruction is accomplished during the L cycles. 
To differentiate between the different types of L cycles, there is a tally counter. This 
is a five stage counter whose output is added with L time to direct the various phases 
in the execution of the instruction. When the required operations are complete for 
first step L time, the tally counter is stepped to produce second step L time. This 
causes the computer to go into the next phase in the execution of the instruction. The 
operation continues to the next step, and so on. All five steps of the tally counter are 
not used for every instruction; each instruction uses as many as it requires. 

Floating Add FAD +0300 (Min I, E, 4L) Figure 5.3-23 

(Max I,E, 13L) 

This instruction adds, algebraically, the floating-point number stored at the location 
indicated by the address and the floating-point number contained in the accumulator. 
The most significant portion of the result appears as a normalized floating-point number 
in the accumulator. The least significant portion of the result appears in the MQ as a 
floating-point number with a characteristic 27-^q less than the characteristic of the 
number in the accumulator. The signs of the AC and MQ are set to the sign of the 
larger factor. If both the resulting MQ and AC fractions are zero, the registers will 
be reset to contain normal zeros with the signs corresponding to the original factor 
having the smaller characteristic. If the characteristics were equal, the resulting 
signs will correspond to the original AC sign. 

The result in the AC is always normalized, whether the original factors were normal 
or not. No attempt is made to normalize the MQ. 

First Step L Time. As first step L time is entered, one of the floating-point words 
to be added is in the AC and the other is in the SR. The objectives of 1st step L time 
are to: 



71 



I Time 
Pri Op 30 



E Time 



OBJECTIVES: 

1 . Bring Characteristic and Fraction to SR. 



SB — *SR 
E 7 (Dl) 

2.12.50.1 



L Time 
1st Step 

2.10.30.1 



OBJECTIVES: 

1 . Prepare for Alignment of Fractions. 
2. Test to See if Alignment would Exceed 
Capacity of Registers. 



(Do NOT Interchange Equals) 




Reset MQ 

(S, l-35)AO(D3) 

2.13.95.1 



Turn on T2 
Tgr 

2.10.38.1 



No (C AC >C SR, Interchange AC and SR) 



1 






1 


r 


SR(S) AC(S) 
A6 (Dl) 

2.13.91.1 


AC(S)-»~SR(S) 
A6(D1) 

2.12.01.1 




AC(l-35)-*SR 
A6(D1) 

2.13.01.1 


AD(Q-35)-*AC 
A6(D1) 

2.13.31.1 



' AC(P) is ' 
Also Gated 
To SR(S) At 

. This Time . 



(C ACC is Always < than C SR, 
so 1 to Adder 8 is Carry to Units 
Position) 



1— *AD(8) 
A8(D3) 

2.13.27.1 



Comp AC(Q-8) 
-►AD A8(D3) 

2.13.22.1 
T 



No (CDIFF < 77 8 ) 



Yes (CDIFF > 77 8 ) 







\ 1 or 2 J— 




AD (3-17)-»AS 
A8 (D3) 




Clear AC 
(Q-35) 


3.06. 


16.1 




2.15.18.1 










AS (3-8) — *■ 

3SBW 

3.06.18.1 










^ m * 





To L Time 2nd Step (Fig 5.3-23B) 



FIGURE 5.3-23A. FAD +0300 



72 



FP Shift 
Rt 

2.13.42.1 



Sh Ac (9-34) 
Rt Every Clock 
Time 

2.12.33.1 




Yes 



OBJECTIVES: 

1 . Alignment of Fractions 

(Must have Common Denominator) 



Sh MQO -34) 
Rt Every Clock 
Time 

2.12.43.1 



Ac (35)-»-MQ(9) 
Every Clock Time 

2.13.42.1 



Step SC Every 
Clock Time 

2.13.71 .1 




OBJECTIVES: 

1 . Test for Possible Double Precision Handling 
2. Add (Signs Alike, or Signs Unlike) 




Turn Off T2 
Tgr A2 (Dl) 



2.10.31 .1 



Unlike 



Alike (True Addition) 



£ 



SR(l-35) 
AO (D6) 

2.13.21 .1 



AD 




AD(Q-35)-»-AC 
A5 (Dl) 

2.13.31.1 




Allow 
Carry AD(9) 
AD (8) A0(D6) 

2.10.46.1 



(Acc Overflow is 
Possible) 



1 


1 








J 


1 


FP Shift 
Rt A6 (Dl) 

2.13.42.1 




Sh AC(9-34) 
Rt A6 (Dl ) 

2.12.33.1 




Sh MQ(l-34) 
Rt A6(D1) 

2.12.43.1 


AC(35KMQ(9) 
A6 (Dl) 

2.13.42.1 




1 _^ AC(9) 
A6 Dl 
2.10.27.1 




- 


1 











To Complement Addition (Fig 5.3-23C) 



To 4th Step (Fig5.3-23D) 
FIGURE 5. 3-23B. FAD +0300 



73 



SR (1-35)*AD 


A0(D6) 




2.13. 


21.1 



Comp AC(9-35) 
-*-AD AO (D6) 

2.13.22.1 



(MQ = 0) 



AD (Q-35)-*AC 
A5 (Dl) 

2.13.31 .1 



Carry -»^D (35) 
AO (D6) 

2.13.27.1 



COMPLEMENT ADDITION 

1 . 9 Carry, Add 1 to Units Position, Change the Sign of 
Acc (SR was > than Acc). 

2. No 9 Carry, Re-complement and Leave the Sign. 
(SR was < than Acc) 






Yos AC (*-35) < SK(5»-35) 


Turn on Col 




9 Carry Tgr 




2.10.37.1 




} 







Off 




T2 
Tgr 



On (MQ ^ 0) 












Turn on FP 
Tgr A6(D1) 

2.10.29.1 




MQ(l-35)-*-SR 
A6(D1) 

2.13.12.1 








f 



SR — AD 
A8(D3) 

2.13.21.1 



AC-^SR 

A10 (Dl) 

2.13.01 .1 



AD (9-35) *AC 
A10 (Dl) 

2.13.31 ■) 



(MQ SR) 



(Interchange SR and AC 
for Double precision 
accuracy) 



To 4th Step L Time (Fig 5.3-23D) 



FIGURE 5.3-23C. FAD +0300 



74 



From Addition, signs alike 



r 



L Time 
4th Step 

2.10.33.1 



Turn Off 
Coi 9 Carry Tr 
A0(D1) 

2.10.37.1 



Comp AC(9-35) 
AD A0(D3) 

2.13.22.1 



1 -*-AD<35) 
A0(D3) 

2.13.27.1 




FP Tgr 



Off 



(Effectively Complemented the MQ 
and Added 1 to the Units Position) 



On 



AD(9-35)-»-AC 
A2(D1) 

2.13.31 .1 



SR (l-35)-»»AD 
A4(D3) 

2.13.21 .1 



(Interchange SR and Acc) 



AC(l-35)-»-SR 
A6(D1) 

2.13.01 .1 



AD(Q-35)*AC 
A6(D1) 

2.13.31.1 



(MQ Now Complemented +1 in SR, 
Set Sr to MQ to Complete Double 
Precision) 



SR(l-35)- 
.A8(D1) 

2.13.41.1 



•MQ 



Turn off FP 
Tgr A10(D1) 

2.10.29.1 



From Addition, signs unlike 



OBJECTIVES: 

1 . Zero Test Acc Frac (Do Not Normalize All Zeros) 
2. Complete Double Precision if Necessary 




Yes AC (9-35) = 0) 



Off (MQ = 0, Do Not 

Normalize All Zeros) 



AD(Q-35) -*AC 
A8 (D3) 

2.13.31.1 




=1 (AC Frac is Normalized) 



(Reset Ac) 



0 (Normalize) 
To 5th Step L Time (Fig 5.3-23E) 

FIGURE 5. 3-23D. FAD +0300 



To End Operation (Fig 5.3-23E) 



75 



(To End Op) 



5th Step 
L Time 

2.10.34.1 



OBJECTIVES: 
1 . Normalize 




FP Shift Lt 
2.13.42.1 



Sh AC(10-35) 
Lt Every Clock 
Time 
2.12.34.1 



Sh MQ(2-35) 
Lt Every Clock 
Time 

2.13.42.1 



MQ(9) - AC (35 
Every Clock 
Time 
2.13.42.1 



Step SC Every 
Clock Time 

2.13.71.1 



Turn on FP 
Tgr A7(D1) 

2.10.29.1 



AC(Q-8)->AD 
5th Step L 

2.13.24.1 



FP End Op 
2.10.35.1 



I Time 
Next Instruction 



Ones— *»AD(Q, 
P, 1,2) 

2.13.27J 



AD(Q-8)-*AC 
All(Dl) 

2.13.31 .1 



OBJECTIVES: 

1 . Compute MQ Char. 

2. Set Acc(s) to MQ(s) 

3. Set MQ Char, if Acc or MQ 
Fraction are / 0 











AC(Q-8)-»-AD 
10 (D3) 

2.13 




l-»-AD(Q,P, 
1,2,3,6,8) 
10 (D3) 

2.13.27.1 



(2's Complement of 27l0; 
Underflow is Possible) 



SC(12-17)-*AD 
5th Step L (3-8) 

3.04.15.1 



(SC Contains 2's Complement 
of Number of Shifts Required to 
Normalize, AC Underflow is 
Possible.) 











AC(S)— 


MQ(S) 




AD(l-8)— SR 


12 (Dl) 






12 (Dl) 


2.13.91 .1 




2.13.04.1 






















Ca rry Of£ 

Yes (Acc or MQ Frac . f 0) 



SR(l-8)-»-MQ 
13 (Dl) 

2.13.41.1 



FIGURE 5. 3-23E. FAD +0300 



76 



1. Put the word with the smallest characteristic in the AC. 

2. Determine the difference between AC and SR characteristics. 

a. If the difference is less than 100g, put the difference in the SC. 

b. If the difference is greater than 77s, clear the AC. 

To determine which characteristic is smaller, the 2's complement of the AC char- 
acteristic is added to the SR characteristic. Also, during this time the MQ is reset 
and T2 trigger is turned on. These are the initial starting conditions for T2 and the MQ. 
Trigger T2 will be used later, during the execution of the instruction, if the MQ con- 
tains a zero or not. 

A Q carry, because of the complement addition of the AC characteristic to the SR 
characteristic, means that the SR characteristic is larger. No Q carry means that the 
AC characteristic is larger. Therefore, the word in the SR is moved to the AC and the 
word in the AC is moved to the storage register. 

Again, the 2's complement of the AC characteristic is added to the SR characteristic 
to determine the exact difference between the characteristics. A characteristic differ- 
ence of less than 100g causes the difference to be put into the SC and a difference greater 
than 77g causes the AC to be cleared. The AC is cleared for a difference greater than 
77g because, due to this difference, the information eventually would be shifted out of 
the AC and MQ anyway. Shifting the MQ and AC fractions right makes possible setting 
the characteristics of the SR to the characteristic of the AC. It takes 66g shifts to move 
a bit from AC fraction position (9) out through MQ fraction position (35). The character- 
istic difference is checked for 77g rather than 66g because this is easier to do in the 
computer. The AC is cleared rather than let shifting take place because machine time 
is saved. 

Second Step L Time. Second step L time is used to shift the AC and MQ fractions 
right a number of places equal to the difference between the AC and MQ characteristics. 
The principle here is the same as moving the point to the left and increasing the expo- 
nent by one for each position that the point is moved. The changing of the characteristic 
is done later. However, the fraction is adjusted for this change during second step. 
The AC and MQ fractions are shifted right until the SC is stepped down to zero. 

Third Step L Time. Third step L time occurs when the SC equals 0. The objectives 
of the third step are to: 

1. Set the AC characteristic equal to the SR characteristic. 

2. Add, algebraically, the AC fraction to the SR fraction. 

3. Make AC sign equal to the algebraic sign of the result of the addition. 

The AC characteristic is set equal to the SR characteristic as a result of the addition 
because the AC(9-35) or the l's complement of AC(9-35) is sent to the adders with SR 
(1-35). Therefore, when AD(Q-35) are gated back to the AC, the correct characteristic 
is set into the AC along with the result of the addition. 

When binary fractions with like signs are added, there is a possibility of a carry out 
of the high order fraction position. This is the same as a carry across a decimal point. 
The 7090 has no register position to hold this carry (1), therefore, the fraction and 
characteristic of the sum must be adjusted. This is done by moving the AC and MQ 
fractions one position to the right, putting the one in the high order position of the AC 
fraction, and increasing the characteristic by one. The characteristic is automatically 
increased by one during the addition because the carry out of AD(9) goes to the AD(8). 



77 



When signs are unlike, a complement addition occurs. A column 9 carry resulting 
from this addition means the AC fraction was smaller than the SR fraction and the re- 
sult placed in the AC is a true number. Assuming the MQ to be zero, this true number 
is 1 less than the sum, because the l's complement of the AC fraction was used for addi- 
tion. Therefore, a one is added to the AC fraction. If the MQ contains something other 
than zero, the result of the addition isl minus MQ fraction less than it should be. There- 
fore, one is not added to the AC fraction, but the MQ is subtracted from this one. This 
is done by, in effect, complementing the MQ. Because no provisions are in the circuits 
to complement the MQ , the MQ contents are moved to the AC through the SR. The re- 
sult of the addition is moved to the SR when the MQ contents are brought into the AC . 

Fourth Step L Time. Fourth step L time is used to: 

1. Complement the AC fraction. 

a. AC contains original MQ fraction if the MQ was not zero. 

b. If original MQ fraction was zero, it was not moved to the AC; therefore, 
this complementing is used to test the AC fraction for a zero result of the 
addition. 

2. If the MQ and AC are zero, clear the AC to give a zero characteristic. 

3. End operation if normalizing is not needed. 

a. If AC and MQ are zero. 

b. If AC (9) contains a one. 

After complementing the AC fraction with the FP trigger on (MQ was not zero), the 
complement is sent to the MQ and the result of the addition is moved from the SR back 
to the AC. Again available circuits must be used to get the complement to the MQ. 
Therefore, the AC is gated to the SR and the SR is gated to the MQ. 

Fifth Step L Time. Fifth step L time is used for normalizing the result and ending 
operation. Normalizing is done by (1) shifting the AC and MQ fractions left until AC (9) 
receives a one, (2) counting the number of shifts, and (3) subtracting the number of 
shifts from the characteristic. The SC is used to count the number of shifts. Since the 
SC is a count down counter which starts from zero, the 2's complement of the number 
of shifts will be in the SC when shifting is stopped. Adding this complement to the 
characteristic of the AC gives the correct adjusted characteristic. 

I Time. I time of the next instruction sets the MQ(S) and characteristic. The AC(S) 
is gated to the MQ(S) so both signs are the same. 

For an MQ and AC fraction that is not zero, the characteristic of the MQ is set 27iq 
(338) * ess ^an the AC characteristic. This is done by adding the 2's complement of 33g 
to the AC characteristic and putting the result into the MQ characteristic. 

Unnormalized Floating Add UFA -0300 (Min I, E, 3L) 

(Max I,E,8L) 

This instruction algebraically adds two floating-point numbers in the same manner 
as FAD. The result, however, is not normalized. The sequence of operation for UFA 
is the same as FAD with these exceptions: 

1. For like SR and AC signs, UFA ends operation at the end of the third step 
because a normalizing step is not needed. 

2. UFA ends operation at the end of the third step if AC and SR signs are unlike 
and there is no column 9 carry as a result of the addition. This is because 
the correct unnormalized result is in the AC and MQ at the end of the 3rd step. 



78 



Floating Add Magnitude FAM +0304 (Min I,E,4L) 

(Max I,E, 13L) 

This instruction algebraically adds the magnitude of the floating-point number stored 
at the location designated by the address to the floating-point number in the accumulator. 
The sequence of operations is identical to that of FAD except that the SR sign is set 
positive during the E cycle. This control line is on Systems 2. 09. 95. 1. 

Unnormalized Add Magnitude UAM -0304 (Min I,E,3L) 

(Max I,E,8L) 

This instruction operates the same as FAD, with the exceptions pointed out in UFA 
and FAM . 

Floating Subtract FSB +0302 (Min I,E,4L) 

(Max I,E,13L) 

This instruction algebraically subtracts the floating point number stored at the loca- 
tion indicated by the address from the floating-point number in the accumulator. FSB 
operates the same as FAD, except that the sign of the word in the SR is inverted during 
the E cycle. This is shown on Systems 2. 09. 95. 1. 

Unnormalized Floating Subtract UFS -0302 (Min I,E,3L) 

(Max I,E,7L) 

This instruction algebraically subtracts two floating-point numbers without normal- 
izing the result. Execution is the same as FAD with the exceptions noted in UFA and 
FSB. 

Floating Subtract Magnitude FSM +0306 (Min I,E,4L) 

(Max I,E,13L) 

This instruction algebraically subtracts the magnitude of the floating-point number 
stored at the location indicated by the address from the floating-point number in the 
accumulator. Execution of this instruction is the same as FAD, except that the sign of 
the word in the SR is forced minus during the E cycle. This is shown on Systems 
2.09.95. 1. 

Unnormalized Subtract Magnitude USM -0306 (Min I, E , 3L) 

(Max I,E,9L) 

This instruction operates the same as FSM, with the exceptions explained under 
UFA. 

Floating Multiply FMP +0260 (Min I,E) Figure 5.3-24 

(Max I,E,11L) 

This instruction multiplies the floating-point number stored at the location designated 
by the address by the floating-point number stored in the MQ. The product appears as 
two floating-point numbers: the most significant part in the accumulator, and the least 
significant part in the MQ. The signs of both registers are set to the algebraic sign of 
the product. If the multiplicand is zero, the product will be two normal zeros with 
proper algebraic signs. If the AC fraction or the multiplier fraction is zero, the AC is 
reset to a normal zero and no characteristic is assigned to the MQ. If the AC fraction 
is not zero, the MQ is assigned a characteristic 27io l ess than the AC characteristic. 

Remember that when multiplying numbers using exponents, the fractions are multi- 
plied and the exponents are added. Multiplying the fractions is done much the same as 
in a MPY operation, by adding and shifting. Adding the characteristic is not enough 



79 



I Time 
Pri Op 26 



t OBJECTIVES: 
E Time 1 . Multiplicand to SR 

2. Zero Test Multiplier Fraction and 
Multiplicand for a Normal Zero 

. I 3. 338 t0 Snift Counter 

4 . Reset Ac (9-35) 



SR(l-8) • 
E Time 



►AD 



2.10.25.1 



MQ (9-35)- 
E0 (D3) 



►SR 



2.12.07.1 



(Multiplicand is a 
Normal Zero) 



Yes 



Mpy Stg Zero 
2.09.53.1 



End Op in 
E Time 

2.09.46.1 



Reset MQ 
Ell (Dl) 

2.15.18.1 



No 




MQ = 0 Turn On 
FP Tgr E2 (Dl) 

2.12.07.1 * 



Turn On FP 
Tgr 

2.10.29.1 




2.10.63.1 
No (SR9-35 may = 0) 



Off 



On 



FP End Op 
2.10.25.11 



33 8 -»* 


SC 


E3 (Dl) 




2.11 . 


78.1 



SB-^SR 

E7 (Dl) 

2.12.50.1 



AD(Q-35) —. 
A10 (Dl) 

2.13.31 .1 



►AC 



AC (9-35) = Zero 

AC (1-8) = Multiplicand Char 



Conditioned by UFM 



V To End Operation (Figure 5.3-24D) * To L Time 1st Step (Figure 5.3-24B) 

FIGURE 5.3-24A. UFM -0260; FMP +0260 



80 



L Time 1st Step 



2.10.23.1 



OBJECTIVES: 

1 . Adjust Characteristics 



AC(Q-8) -> AD 
A0(D3) 

2.13.24.1 



1-*>AD (Q,P,1) 
AO (D3) 

2.13.27.1 



Subtract Base 200s From Multiplicand Char 



AD(Q-8) 


-*■ AC 


A2 (Dl) 




2.13.31 .1 


1 




AD(l-8) 


SR 


A4 (Dl) 




2.13.04.1 



Zeros to SR (1-8) 



MQ (1-8) -*-SR 
A6(D1) 

2.13.12.1 



SR (1-8) -*• MQ 
A6(D1) 

2.13.41 .1 



Multiplier Char to SR, Zeros to MQ(l-8) 



AC(Q-8) 


AD 


A8(D3) 




2.13.24.1 



SR(l-8) 


AD 


A8(D3) 




2.13.21 .1 



Addition of Multiplicand and Multiplier 
Characteristics 



AD(Q-8) 


-►AC 


A10(D1) 




2.13.31 .1 



Sum in Accumulator, Overflow or Underflow is 
Possible 



To L Time 2nd Step (Fig5.3-24C) 

FIGURE 5.3-24B. UFM - 0260; FMP + 0260 



81 



Turn On 
T2 Tgr 
2.10.38.1 




OBJECTIVES: 

1 . Multiply 

2. Normalize 1 Place if Necessary 



Add Cycle 
AC(9-35)-»-AD| 
2nd Step L 
2.12.24.1 



SR (9-35)-* AD 
2nd Step L 

2.13.21 .1 



Reset 90V 
Tgr AO, AU 
A8 
2.10.24.1 



AD(9-35)-»-AC 
A2(D1)A6(D1) 
A10(D1) 
2.12.31 .1 



1-*AC(9) 

A3(D1)A7(D1) 

All(Dl) 

2.10.27.1 



Sh AC and MQ Rt 

A3(D1)A7(D1) 

All(Dl) 

2.09.54.1 



MQ 



AC(9-35)- 
(9) A3(D1) 
A7(D1)A11(D1) 

2.13.42.1 



Step SC 

A3(D1)A7(D1) 

All(Dl) 

2.09.51.1 



Sh AC and MQ) 
Rt 



2.09.54.1 



Sh AC(9-34) 
MQ(l-34) Rt 
2.12.33.1 
2.12.43.1 



AC(35)-*MQ(9) 
Every Clock Time 

2.13.42.1 



Step SC 
Every Clock 
Time 

2.09.54.1 



To Turn on FP Trigger (Fig 5.3-24D) 



FIGURE 5.3-24C. UFM - 0260; FMP + 0260 



82 



Figure 5.3-2A 



To 
End Op 



Yes 



Figure 5.3-24C 

t 



Turn On 
FP Tgr A6(D1) 

2.1C.29.1 




No (Normalize 1 Place) 



AC(Q-8)-»-AD 
A8(D3) 

2.13.24.1 * 



1 — »► AD 

(Q-8) 

2.10.24.1' 



(Subtract one from Char by Adding 2's 
Complement of 1 ) 



AD(Q-8)-»>AC 
A10(D1) 

2.13.31 .1 * 



FP Shift Lt 
A10(D1) 

2.13.42.1 



Sh AC(10-35) 
MQ(2-35) Lt 

2.12.34.1* 
2.12.42.1 



MQ(9) — »-AC 
(35)A10(D1) 

2.13.42.1* 



End Op 



I Time 
Next Inst 



OBJECTIVES: 

1 . Set MQ Char if AC Frac ^ 0 
2. Set Signs of AC and MQ 



(Set MQ Char) 
No 




AD(l-8) -»-SR 


12 (Dl) 


2.13. 


04.1* 


1 





SR(l-8)- 
I3(D1) 



-MQ 



2.13.41 .1 



Comp AC (9-35) 
-*»AD I0(D3) 

2.12.22.1 



Yes 

(Reset AC) 



Reset ACC 
12 (Dl) 
2.10.25.1* 



1-*AD(35) 
I0(D3) 

2.13.27.1 



AC(Q-8)- 
I0(D3) 

2.13.24.1 



•AD 



Unlike 



Set AC and MQ 
Signs Minus 16 (Dl ) 

2.13.91 .1 



2's Comp 33g ■ 
AD I0(D3) 

2.13.27.1 




Alike 



Set AC and MQ 
Signs Plus 16 (Dl) 

2.13.91 .1 




T2 
Tgr 

4* 



Off 



(Did Not 
go to L 
Time) 



Reset MQ 
(1-35)I4(D1) 

2.10.25.1 ' 



^Conditioned by UFM 



FIGURE 5.3-24D. UFM -0260; FMP + 0260 



83 



to produce the proper characteristic of the product. Because both of the original char- 
acteristics are the exponent plus 20 O3, adding these characteristics would produce a 
resultant characteristic 200g too large. Therefore, the addition of the characteristics 
must be adjusted by 2OO3. 

The execution of this instruction is accomplished by I, E, and L cycles. The L 
cycles are divided into first step L time and second step L time. 

The E cycle, in addition to bringing the word from storage, has the following objec- 
tives: 

1. For a zero MQ fraction 

a. Put zeros in the characteristic of the SR and the MQ 

b. End operation at the end of the E cycle 

2. For a zero storage fraction 

a. Reset the MQ 

b. End operation at the end of the E cycle 

3. Set 33 § in the SC (used to count the number of shifts) 

4. Reset the AC 

If either the MQ or the storage fraction is zero, the product must also be zero. 
Therefore, for this zero condition the MQ(l-35) and the AC(Q-35) contain zeros at the 
end of the E cycle. This is a normal zero product. For this zero condition end opera- 
tion comes at the end of E time because no further multiplication is necessary. 

To check the MQ fraction for zero, MQ(9-35) is gated to the SR. The set and hold of 
the SR are not operated; the information does not go to the SR but to the zero checking 
circuits on Systems 2. 12. 47. 1. The FP trigger is used to remember the MQ zero 
condition and to cause end operation at the end of the E cycle. 

First step L time is used to get the initial characteristic of the final product. This 
characteristic may be changed at the end of FMP if normalizing is required. 

The characteristic of the SR is reduced by 200g so the characteristic of the product 
will be only 200s greater than the exponent. The multiplicand characteristic minus 
200g is put into the AC, and the multiplier characteristic is put into the SR. The two 
characteristics are added to produce the AC characteristic for the product. During 
this time the MQ characteristic is set to zero. 

Second step L time is used to do the fraction multiplication and to normalize the 
product. The multiplication is done the same as in MPY, by adding and shifting. For 
no bits in MQ(34-35) fast shifting occurs, otherwise only three shifts per cycle take 
place. If there is a carry out of AD (9) during the add cycle, a one is put into AC 
(9) when the AC and MQ are shifted right. 

When 33g shifts are complete, the fraction multiplication is accomplished and the 
shift counter equals zero. The shift counter going to zero turns on the FP trigger, and 
the trigger is used to instruct the system that the multiplication part of the instruction 
is finished. 

If AC (9) is zero, a single normalizing step is performed. One step is the maximum 
needed if two normal numbers were used for the multiplication. 



84 



During I time of the next instruction, the AC fraction is checked for zero by adding 
one to the l's complement of the fraction. If the fraction is zero, the addition will 
cause a column 9 carry. For a zero AC fraction, the whole AC is set to zero and the 
characteristic of the MQ is left at zero. If the AC fraction is not zero, there is no 
column 9 carry and the MQ characteristic is set 27^0 l ess than the AC characteristic. 
During I time of the next instruction, the AC and MQ signs are set to the algebraic sign 
of the product. 

Unnormalized Floating Multiply UFM -0260 (Min I,E) 

(Max I,E,11L) 

This instruction multiplies the floating-point number stored at the location indicated 
by the address by the floating-point number in the MQ. This instruction operates the 
same as FMP except that the result is not normalized or tested. The minus PR (S) pre- 
vents FP normalizing gate (Systems 2. 10.24. 1). The PR (S) not being plus prevents the 
reset of the AC during the following I cycle (Systems 2. 10. 25. 1). The minus PR (S) 
prevents turning on the FP trigger if MQ = 0, Systems 02. 12. 07. 0. 

Floating Round FRN +0760. . . 0011(1, L) Figure 5. 3-25 

This instruction examines the contents of MQ(9) and if MQ(9) contains a bit, a one 
is added to the contents of the AC. A carry out of AC (9) increases the characteristic 
by one, causes the fraction to be shifted right, and a one to be placed in AC (9). 

Floating Divide or Halt FDH +0240 (Min I, E, L) Figure 5. 3-26 

(Max I,E,12L) 

This instruction divides the floating-point number placed in the AC by the floating- 
point number stored at location X. The result is a floating-point quotient in the MQ 
and the floating-point remainder of the dividend in the AC. The sign of the MQ is the 
algebraic sign of the quotient. The sign of the AC is the sign of the dividend. The 
characteristic of the MQ is equal to the characteristic of the ACC minus the character- 
istic of the SR, increased by 200s. The characteristic of the remainder is 27iQless 
than the original dividend characteristic . 

If two normalized numbers are used as divisor and dividend fractions, the dividend 
fraction cannot be twice as large as the divisor fraction. Therefore, the 7090 is 
designated to halt only when the dividend fraction is at least twice as large as the divisor 
fraction. The divide check indicator is turned on to cause the halt. The contents of the 
MQ will be normal zero and the contents of the ACC will remain unchanged. 

A zero dividend fraction causes the division to be skipped, but does not halt the 
computer. A normal zero quotient, plus remainder, results. If the initial factors are 
normal floating point numbers, the quotient is also normal. 

As in any division using exponents, the fractions are divided and the exponent of the 
divisor is subtracted from the exponent of the dividend. The result is the correct quo- 
tient factor and exponent. Division of the fractions is done in the same manner as DVH, 
by shifting left and attempting reduction. When reduction is successful, a bit is put 
into MQ(35). Only 27^q reductions are attempted in FDH because the fraction is con- 
tained in 27-LQ Positions. 

FDH uses an E cycle and several L cycles. The L cycles are divided into three 
types (first, second, and third step) through use of the tally counter. 



85 



1 Time 
Pri Op 76 






L Tim 


e 




MQ(9) = 1 



No 





Yes 


FP Rnd Gate 


LO (D6) 




2.10. 


27.1 



AC(Q-35) 
-*-AD L0(D6) 

2.13.24.1 



One *AD(35) 


L0(D6) 




2.13 


.27.1 



No 



AD(Q-35) 
-»-AC L5(D1) 

2.10.27.1 






Yes 




CarryAD(9) 
-»AD(8) 






2.10. 


46.1 




1 


f 



Sh AC(9-34) 
Rt L8(D1) 

2.12.33.1 



One-*-AC(9) 
L8(D1) ' 

2.10.27.1 



End Op 



FIGURE 5.3-25. FRN +0760. . .001 1 



86 



FP Shift Rt 
E10 (Dl) 

2.13.42.1 



I Time 
Pri Op 24 



E Time 



OBJECTIVES: 

1 . 33g to Shift Counter 

2. Divisor to SR 

3 . Prepare for Divide Check 
Test by Halving AC Frac 



33o-*SC 
E3 (Dl) 

2.11.78.1 



Reset MQ (S, 
1-35) E6(D1) 

2.13.95.1 



♦ SR 
Dl 



2.12.50.1 



(Divisor Char and Fraction 
now in SR) 



Sh AC (9-34) 
Rt E10(D1) 

2.12.33.1 



Sh MQ (1-34) 
Rt E10 (Dl) 

2.12.43.1 



AC(35) -*-MQ 
(9) E10 (Dl) 

2.13.42.1 



L Time 
1st Step 



2.10.41.1 



OBJECTIVES: 

1 . Divide Check Test 

2. Set MQ Sign 

3. End Op if AC Frac Equals Zero 

4. Char Diff to AC if FP Tgr is on 




Turn On 

FP Tgr A3(D1) 

2.10.29.1 



Turn On 

T2 Tgr A3(D1) 

2.10.38.1 



Turn on Divide 
Chk Tgr A3(D1) 
and Tl Tgr 
2.10.53.1 




Alike 



Set MQ(s) 
Minus A3(D1) 

2.13.91.1 



FP Shift Lt 
A3(D1) 

2.13.42.1 



Sh AC (10-35) 
Lt A3(D1) 

2.12.34.1 



Sh MQ(2-35) 
Lt A3(D1) 

2.12.42.1 



SR(l-8) 


-*AD 


A4 (D3) 




2.13.21 .1 



MQ(9) — ►AC" 
(35) A3 (Dl) 

2.13.42.1 




Comp AC (Q-35) 
AD A4(D3) 



Yes 



Turn on Col 
9 Carry Tgr 

2.10.37.1 




FP 



Off 



(Partial Char Diff; 
Quotient Overflow or 
Underflow is Possible) 



V. Trigger S 




On 


AD(Q-8)-»-AC 
A6 (Dl) 




2.13.31.1 













To Fig 5.3-26B 



FIGURE 5. 3-26A. FDH + 0240 



87 



From Fig 5.3-26A 




On (AC (9-35) = 0) 



Off 



End Op 
2.10.35.1 



Turn On T2 
A10(D1) 

2.10.38.1 



Set AC(s) 
Plus A10(D1) 

2.13.91 .1 



AD (Q-35) 
AC A10(D1) 

2.13.31 .1 



(Reset AC) 



OBJECTIVES: 

1 . Test for Quotient Equal to 
1 or More . 



To I Time - Fiq 5.3-26D 



(Dividend now is Complement Form 
for Reduction Cycles) 




To L Time 3rd Step - Fig 5.3-26C 

FIGURE 5.3-26B. FDH + 0240 



From Fig 5.3-26B 

I 



L Time 
3rd Step 
2.10.43.1 
2.10.44.1 



OBJECTIVES: 

1 . 27 Reduction Attempts, 26 Shifts 

2. Compute Quotient Char 

3. Re-compute Original Dividend Char and Set 
to AC (Q-8) 

4. End Op; Go to I Time 



SR(9-35)— *- 
AD 3rd Step L 

2.13.21 .1 



AC(Q-35)— >■ 
AD 3rd Step L 

2.13.24.1 



1-»*AD(1) 


A4(D3) 




2.13. 


27.1 



( For Final Quotient Char Add 2008 ; MQ 
Overflow or Underflow is Possible) 



SR (1-8) — * 
MQ A6(D1) 

2.13.41 .1 



AD(l-8)^ 

SR A6(D1) 

2.13.04.1 



(Final Quotient Char in SR; 
Save Original Divisor Char 
in MQ) 



No 




AD(9-35)— 
AC A2(D1) 
A6(D1) A10(D1) 

2.13.31.1 



1-**MQ(35) 
A2(D1) A6(D1) 
A10(D1) 

2.09.51 .1 



Yes (SR>AC; 
Simulated AD 
8 Carry) 



(SC = 0) On 



SR (1-8) — * 
MQ A7(D1) 

2.13.41 .1 



MQ(l-8) — * 
SR A7(D1) 

2.13.12.1 



SR (1-8) —J 
AD A8(D3) 

2.13.21 .1 




FP Shift Lt 
A3(D1) A7(D1) 
All (Dl) 

2.13.42.1 



Sh AC (10-35) 
MQ(2-35) Lt 
2.12.34.1 
2.12.42.1 



l-»-AC(35) 

A3(D1) A7(D1) 
All(Dl) 
2.13.42.1 



NOTE: FP Tgr Must be on 
to Finish Computation of 
Original Dividend Char 



Step SC 
A3(D1)A7(D1) 
All (Dl) 
2.13.71.1 



End Op 
2.10.35.1 



AD(Q-8) — 3 
AC A10(D1) 

2.13.31 .1 



(Original Dividend Char is 
now in AC; if Quotient>" than 
1, it is now Original +1) 





No 



Turn On 
FP Tgr 

2.10.29.1 



To I Time Fig 5.3-26C 



FIGURE 5.3-26C. FDH+0240 



89 



From End Op Fig 5.3-26B 



From End Op Fig 5.3-26C 




Turn O 


n MST 


Tgr 




4.20.11.1 


1 




B Cycle 


Inter- 


rupt All(Dl) 


8.00. 


13.1 



OBJECTIVES: 

1 . Set Char of Remainder to Original Dividend 
Char -27 10 if T2 is off (No Divide Check, 
and AC Frac f 0) 
2. Stop If Divide Check Occurred 



Comp AC (9-35) 
AD 10 (D3) 

2.13.22.1 



AC(Q-8) - 
AD 10 (D3) 

2.13.24.1 



AD (Q-35) - 
AC 12 (Dl) 

2.13.31 .1 



1 -> AD(Q,P, 
1, 2, 3, 6, 8 
I0(D3) 
2.13.27.1 



(2's Comp 
of 27 10 ) 



FIGURE 5.3-26D. FDH+0240 



90 



The E cycle is used to: 

1. Reset the MQ 

2. Bring the divisor from storage 

3. Set 33g (27io) into the SC (used to count the number of shifts during divide) 

4. Divide dividend fraction by 2 by shifting the fraction right one place (to be 
used for comparison of dividend fraction to divisor fraction) 

First step L time is used to: 

1. Determine if dividend fraction is more or less than two times the divisor 
fraction 

2. Set the MQ(S) to the algebraic sign of the quotient 

3. Shift dividend left one place to put dividend back to initial position 

4. Check AC fraction for zero 

5. Get the difference between divisor and dividend characteristics 

6. End operation if the AC fraction is zero or if the dividend fraction is twice 
as large or larger than the divisor fraction 

7. Reset the whole AC if the AC fraction is zero 

Second step L time is used to: 

1. Increase the characteristic difference by one if dividend fraction is equal to 
or greater than the divisor fraction 

2. Shift the dividend fraction left one place if the dividend fraction is less than 
the divisor fraction 

3. Step the shift counter down to 26 10 --the desired number of shifts to move a 
bit from MQ(35) to MQ(9). 

Third step L time is used to do the actual division. The objectives of third step L 
time are to: 

1. Attempt to reduce the AC fraction by the amount of the divisor fraction 

2. If the reduction is successful put a 1 in MQ(35) 

3. Shift AC and MQ left one place, step shift counter, and put a 1 in AC (3 5) 

4. Repeat steps 1, 2, and 3 until the SC equals zero 

5. Compute the characteristic of the quotient and put it into the MQ 

6. End operation when the shifting and reductions are complete 

I time of the next instruction is used to: 

1. If there was no divide check and the dividend fraction was not zero: 

a. AC fraction is re -complemented to get true number 

b. Characteristic of the remainder is set to 27-lq less than the original 
characteristic of the dividend 

2. Stop the machine if there was a divide check 

Floating Divide or Proceed FDP +0241 (Min I,E, L) 

(Max I,E,12L) 

This instruction operates the same as FDH, except that a divide check does not 
halt the computer. 

5.3.05 Transfer Instructions 

Transfer instructions are used to alter the sequence of instructions. The condi- 
tional transfers allow automatic testing of problem conditions without stopping the 



91 



computer. The transfer instructions greatly reduce program length by allowing program 
loops and subroutine operation 

Transfer TRA +0020 (I) Figure 5. 3-27 

The transfer instruction causes the computer to take its next instruction from loca- 
tion X and resets the instruction counter to X. The address portion of the transfer in- 
struction is substituted for the instruction counter when setting the address register to 
locate the next instruction. The instruction counter is then set to this new address, 
and the instruction sequence continues from the new location. 

Transfer on MQ Plus TQP +0162(1) Figure 5.3-28 

If the sign of the MQ register is positive, a transfer will be taken to storage location 
X. If the MQ sign is minus, the computer proceeds to the next instruction in sequence. 

Transfer on Plus TPL +0120 (I) 

If the sign of the accumulator is plus, a transfer is taken to storage location X. 
If the sign is minus, the computer proceeds to the next instruction in sequence. TPL 
is executed in the same manner as TQP, except that the AC sign rather than the MQ 
sign is tested. See Systems 2. 10. 08. 1. 

Transfer on Minus TMI -0120 (I) 

If the sign of the AC is minus, a transfer is taken to storage location X. If the AC 
sign is plus, the computer proceeds to the next instruction in sequence. The execu- 
tion of this instruction is the same as TQP, except that the AC sign rather than the 
MQ sign is tested. See Systems 2. 10. 08. 1. 

Transfer on Overflow TOV +0140 (I) 

If the AC overflow trigger is on as a result of a previous operation, a transfer is 
taken to storage location X, and the overflow trigger is turned off. If the overflow 
trigger is off, the computer proceeds to the next instruction in sequence. Execution 
of TOV is much like TQP, except that the overflow trigger rather than the MQ sign is 
tested. See Systems 2. 10. 08. 1. The AC overflow trigger is turned off on Systems 
2. 10.36. 1. 

Transfer on No Overflow TNO -0140 (I) 

If the AC overflow trigger is off, the next instruction is taken from storage location 
X. If the overflow trigger is on, no transfer is taken, and the overflow trigger is turned 
off. Operation of this instruction is the same as TQP, except that the overflow trigger 
rather than the MQ sign is tested. 

Transfer on Quotient Overflow TQO +0161 (I) 

If the quotient overflow is on because of a previous operation, a transfer is taken to 
storage location X, and the quotient overflow trigger is turned off. If the quotient over- 
flow trigger is off, the computer proceeds to the next Instruction in sequence. This is 
a 704 compatibility instruction. 

Transfer on Zero TZE +0100 (I, L) Figure 5. 3-29 

If the contents of the AC (including the overflow positions) are zero, a transfer is 
taken to storage location X. If the contents are not zero, the computer proceeds to 
the next instruction in sequence. In either case the contents of the AC are not changed. 



92 



I Time 
Pri Op 02 



Any Trans or 
Store and Trap 

2.11.55.1 

~~t 



Block Normal 
AD->-AS 
19 (D3) 
3.06.16.1 



One Cycle 
Trans Cond 
Met 

2.10.08.1 



Xfer Cndtl 
AD ->-AS 
19 (D3) 
2.10.09.1 



SR(18-35)-*AD 
(P-17) 19 (D3) 

2.12.16.1 



I End Op 
8.00.02.1 



AD(3-17)->AS 
I 9 (D3) 

3.06.16.1 



Prevent 
PC-* AS 
13.05.09.1 



I Time 
Next Inst 



AR-fc-PC 

I3(D1) 
3.06.05.1 



AS ->■ AR 

lll(Dl) 

3.06.18.1 



I Time 
Pri Op 16 



Any Trans or 
Store and Trap 



2.11 .55.1 




.12.16.1 



One Cycle 
Trans Cond Met 

.10.08 



Block Normal 
AD-»~AS 
19 (D3) 
3.06.16.1 



Xfer Cndtl 
AD-*AS 
2.10.09.1 



AD(3-17)-*AS 
I 9 (D3) 
3.06.16.1 



AS -*>AR 
lll(Dl) 
3.06.18.1 



Prevent 
PC-* AS 
3.05.09.1 



I End Op 
8.00.02.1 



I Time 
Next Inst 



AR PC 

I3(D1) 

3.06.05.1 



I Time 
Pri Op 10 



Any Trans or 
Store and Trap 

2.11 .55.1 



Trans Cndtl 
AD -*AS 



2.10.09.1 
T 

£ — =1 



AD (3-17)-»-AS 
19 (D3) 
3.06.16.1 



AS -»> AR 
lll(Dl) 
3.06.18.1 









L Time 





Comp AC->-AD 
L Time 
2.12.22.1 



1 



No 





Carry AD(35) 
L5 (D6) 
2. 12.29.1 



,Q Carry 



Yes 



TNZ 



TZE 



Inst 



TZE 



Condition Met 
2.10.07.1 




Inst 
TNZ 



AR-*PC 
L9(D1) 
3.06.05.1 



L End Op 
8.00.01 .1 



FIGURE 5.3-27. TRA +0020 



FIGURE 5.3-28. TQP + 0162 



FIGURE 5.3-29. TZE + 0100; TNZ - 0100 



To test for a zero condition, the accumulator is complemented to the adders, and a one 
is added to position 35. If a zero condition exists, a carry results which ripples through 
all of the adders and turns on the Q carry trigger. The Q carry trigger is used to condi- 
tion the transfer circuits. 

Transfer on No Zero TNZ -0100 (I, L) Figure 5.3-29 

If the contents of the AC are not zero, the next instruction is taken from storage lo- 
cation X. If the contents are zero, the computer proceeds to the next instruction in 
sequence . 

Transfer on Low MQ TLQ +0040 (I, L) Figure 5.3-30 

An algebraic comparison is made between the MQ and the accumulator contents. If 
the MQ contents are less than the accumulator contents, an instruction transfer is 
made to storage location X. If the MQ is greater or equal, no transfer is taken. For 
this instruction a -i-O is considered to be larger than a -0. The contents of both registers 
are left unchanged. 

The operation is performed by adding the contents of the MQ to the complemented 
accumulator contents. The Q carry trigger is then matched with the register signs to 
determine whether the conditions for transfer have been met. To prevent transfers 
when the factors are equal, a one is added to AC(35) to produce a Q carry when the AC 
factor is plus. 

The following table illustrates comparisons which might be made, along with the 
desired result: 



No. in AC 


No. in MQ 


Q Carry 


Transfer 


-7 


-6 


No 


No 


-6 


-6 


No 


No 


-0 


-6 


Yes 


Yes 


-0 


-0 


No 


No 


+0 


-0 


Yes 


Yes 


-0 


+0 


No 


No 


-6 


+6 


No 


No 


,-0 


+6 


Yes 


No 


+6 


+6 


Yes 


No 


+7 


+6 


No 


Yes 



Transfer on Channel in Operation TCO +XXXX (I, L) Figure 5.3-31 

This instruction causes a transfer to storage location X if the particular data channel 
is in use. Operation codes +0060 through +0067 are used to check data channels A through 
H, respectively. 

Transfer on Channel Not in Operation TCN -XXXX (I, L) Figure 5. 3-31 

TCN causes a transfer to storage location X if the data channel is not in operation. 
Operation codes -0060 through -0067 are used to select data channels A through H, 
respectively. 



94 



1 Time 
Pri Op 04 






Any Trans or 
Store and Trap 

2.11 .55.1 






Trans C 
AD 

2.10 


Indtl 
AS 

.09.1 



AD(3-17)-*-AS 
9 (D3) 

3.06.16.1 



Comp AC(Q-35) 
-*-AD L Time 

2.12.22.1 



AS -fr- 


AR 


ill (Dl) 


3.06. 


18.1 



L Tin 



MQ(S-35)-*-SR 
L2 (Dl) 

2.12.07.1 




AC(S)Plus 
No 



Yes 



SR-*-AD 
L5 (D6) 

2.12.14.1 



Carry-*. 
AD (35) 

2.09.30.1 



w I No Transfer 

^ on Equals 



Yes 




SR(S) Minus 








Condition 
Met 

2.10.07.1 






Minus on TR 

Met L9(D1) 
2.10.09.1 






AR -*■ PC 
L9 (Dl) 

3.06.05.1 










End Op 



FIGURE 5.3-30. TLQ +0040 



95 



I Time 
Pri Op 06 



Any Trans or 
Store and Trap 

2.11 .55.1 



Trans Cndtl 
AD -*AS 
2.10.09.1 



AD(3-17)-*AS 
I 9 (D3) 
3.06.16.1 



AS -*AR 

lll(Dl) 

3.06.18.1 









L Time 





No 




Cond Met 
2.10.07.1 



AR — * 


•PC 


L9(D1) 


3.06. 


05.1 



I Time 
Pri Op 02 



Any Trans or 
Store and Trap 

2.11 .55.1 



Trans Cndtl 
AD-*AS 
2.10.09.1 



I 



AD(3-17)->- 
I 9 (D3) 
3.06.16.1 

t 



AS 



AS —v AR 
lll(Dl) 
3.06.18.1 









L Time 








PC 


L9(D1 


) 


3.06.05.1 









1 Time 
Next Inst 




Turn Off 
Channel Trigger 
2 (D2) 

60.32.02.2 



End Op 



End Op 



IGURE 5.3-31 . TCO + 0060; + 0061; + 0062; Etc. 

TCN - 0060; - 0061; - 0062; Etc. 



FIGURE 5.3-32. TRC + 0022; -0022; + 0024; Etc. 

TEF + 0030; -0030; + 0031; Etc. 



Transfer on Data Channel Redundancy Check TRC ±XXXX(I, L) Figure 5. 3-32 



If the data channel redundancy check trigger is on, a transfer is taken to location X 
and the trigger is turned off. If the trigger is off, the computer takes the next sequential 
instruction. Operation codes +0022, -0022, +0024, -0024, +0026, -0026, +0027, and 
-0027 are used to select data channels A through H, respectively. 

Transfer on Data Channel End of 'File TEF ±XXXX(I, L) Figure 5. 3-32 

If the data channel end-of-file trigger is on, a transfer is taken to storage location 
X and the trigger is turned off. If the trigger is off, the computer takes the next in- 
struction in sequence. Operation codes +0030, -0030, +0031, -0031, +0032, -0032, 
+0033, and -0033 are used to select data channels A through H, respectively. 

5. 3. 06 Trap Mode Instructions 

The 7090 can be operated in either of two modes, normal or trapping. Entrance to 
trapping mode is gained by executing the ETM instruction. Exit is accomplished by 
using the LTM instruction or the clear or reset keys on the console. Trapping mode 
affects the operation of transfer instructions except TTR. In trapping mode, the location 
of each transfer instruction is stored in the address portion of location 0000. Successful 
transfers are not executed; instead, an instruction transfer, or trap, is taken to location 
0001. One instruction, trap transfer, is immune to trapping mode. The locating of 
successful transfers and the trap to a common check point make trapping mode useful 
for debugging program flow. Unsuccessful transfers have their location stored in the 
address portion of 0000, but do not trap to 0001. 

Enter Trapping Mode ETM +0760. . . 0007 (I, L) 

This instruction places the computer in trapping mode by turning on the trap mode 
trigger on Systems 2. 10. 53. 1. The computer remains in trapping mode until a LTM 
instruction is executed or the clear or reset buttons are depressed. ETM is a primary 
operation 76 instruction and requires an I and an L cycle. 

TRA in Trapping Mode TR A +0020 (I, E) 

The effect of trapping mode on a transfer is shown in Figure 5. 3-33. 

Leave Trapping Mode LTM -0760. . . 0007 (I, L) 

This instruction returns the computer to normal mode by turning off the trap mode 
trigger on Systems 2. 10. 53. 1. This is a primary operation 76 instruction, and an I 
and an L cycle are required. 

Trap Transfer TTR +0021 (I) 

This is the only instruction which provides an instruction transfer to location X 
regardless of the operating mode of the computer. The TTR instruction nullifies the 
transfer blocking circuits of trapping mode (Systems 2. 10. 53. 1) and operates like TRA. 

Store Location and Trap STR -1000 (I, E) Figure 5.3-34 

This instruction stores its location plus one in the address portion of storage loca.- 



97 



I Time 
Pri Op 02 











1 






Prevent Xfer 




Prevent Step of 






Cndtl AD-W\S 




PC 






2.10.09.1 




2.11.51.1 








r 




Prevent 1 End 




AS -*-AR 




Op 






lll(Dl) 




Zero in AR 


8.00.02.1 




3.06. 


18.1 





E Time 



End Op 
E10 (Dl) 
1.00.09.1 



AS-^-AR 

Ell (Dl) 

3.06.18. 




Retain Op Code 
and Decrement 



Advance PC 
E9(D1) 

2.11.51.1 



FIGURE 5.3-33. TRA +0020 TRAP MODE 



I Time 
Pri Op 00 



Trans Ctrl 
2.11.55.1 



Advance PC 
I9(D1) 
2.11 .51 .1 



Prevent AD 
(3-17) --AS 

19 (D3) 

2.10.09.1 




AS-*AR 
lll(Dl) 

3.06.18.1 











Zero in AR 



E Time 



MF Store 
Address 

2.09.01 .1 

— CZ 



MF Store 
Ctrl 

2.09.00.1 



J 



PC --AS 
E0(D3) 

3.05.09.1 



AS-*-SR (21- 
35) E2 (Dl) 

3.06.12.1 



SR —SB 
E4(D3) 

2.09.00.1 

C 



Prevent 
SB-*»SR 
E7(D1) 
2.12.50.1 

z~r~ 



One -*AS 
(16) E10(D2) 

3.06.14.1 



AS -»-AR 

Ell(Dl) 

3.06.18.1 



Two 



End Op 
E10 (Dl) 



Prevent PC 
—AS E9 
(D3) 

3.05.09.1 



I Time 
Next Inst 



AR— ^PC 

13(D1) 

3.06.05.1 



Two 



PC 



Step PC 



FIGURE 5.3-34. STR-1000 



tion 0000. It then traps or transfers the computer to location 0002 where the instruction 
sequence is resumed. STR does not place the computer in trapping mode. 

5.3.07 Skip Instructions 

The skip instructions allow the programmer to alter the program to meet special 
conditions without stopping the computer. These instructions are similar to the condi- 
tional transfer instructions but, instead of transferring, they cause one or two instruc- 
tions to be skipped. Skipping is accomplished by supplying an extra advance pulse to 
the instruction counter. 

Most skip instructions cause the computer to skip when the condition being tested is 
met. The exceptions are the error testing and I-O testing instructions, which cause 
skipping when the condition being tested is not met; e. g. , when there are no errors. 
This exception (skip on no error) allows a straight-line program until an error is de- 
tected. To process an error, an instruction transferring to an error subroutine usually 
follows the test instruction. Another exception, the CAS instruction, has three possible 
results: it can fail to skip for AC greater, skip once for equal, or skip twice for AC less. 

P Bit Test PBT -0760. . . 0001(1, L) Figure 5. 3-35 

A bit in accumulator (P) position causes the computer to skip one instruction. If 
there is no bit in (P), the computer takes the next instruction in sequence. 

Low-Order Bit Test LBT +0760. . . 0001 (I, L) Figure 5. 3-35 

A bit in accumulator (35) causes the computer to skip one instruction. If there is 
no bit in (35), the computer takes the next instruction in sequence. 

Storage Zero Test ZET +0520 (I, E) Figure 5.3-36 

If the contents of storage location X, except the sign, are zero, the computer will 
skip one instruction. If storage is not zero, the computer proceeds to the next instruc- 
tion in sequence. Storage is unchanged. The information from storage on the SB is 
tested for zero as shown on Systems 2. 12. 52. 1. 

Storage Non-Zero Test NZT -0520 (I, E) Figure 5.3-36 

If positions (1-35) of storage location X are not zero, the computer skips the next 
instruction. If the contents of storage location X are zero, no skip is taken. Storage 
is unchanged. 

Compare Accumulator with Storage CAS +0340 (I,E, L) Figure 5. 3-37 

The accumulator is compared with the word at storage location X. Comparison is 
accomplished by taking an algebraic difference. If the accumulator is greater than the 
word in storage, no skip is taken. If the accumulator is equal to the word in storage, 
one instruction is skipped. If the accumulator is less than the word in storage, the 
next two instructions are skipped. Neither the accumulator nor the word in storage is 
changed. 



99 



I Time 
Pri Op 76 



L Tin 




Off 



To Sense 
Skip 

2.09.58.1 



Sense Skip 

L9(D1) 

2.09.59.1 



I 



Advance PC 



2.11.50.1 



Turn Off Div 
Ck Tgr L10(D1) 

2.10.53.1 



End Op 



FIGURE 5.3-35. PBT - 0760. . .0001; LBT +0760. . .0001; DCT +0760. . .001 



I Time 
Pri Op 52 



ZE 

E Time 



SB ->SR 

E7(D1) 

2.12.50.1 




Advance PC 
E9(D1) 
2.11.50.1 



End Op 



FIGURE 5.3-36. ZET +0520; NZT -0520 




Advance PC 



L9(D1) 
2.11.50.1 

End Op 



FIGURE 5.3-37. CAS +0340; LAS-0340 



To execute this instruction, an E cycle is required to bring the word in storage to 
the storage register; then an L cycle is used for two comparisons in the adders. For 
the first comparison, the SR and the complement of the AC are fed to the adders; the 
Q carry and sign conditions are matched to condition the first possible skip. The sec- 
ond comparison is made after a one has been added to the difference, to differentiate 
words of equal magnitude. 

The following illustrate some of the possible combinations: 



Number in 


Number in 


Q Carry Tgr 




Accumulator 


Storage 


1st Comp 


2nd Comp 


Result 


-6 


-7 


On 


On 


Next Instruction 


-6 


-6 


Off 


On 


Skip 1 Instruction 


-6 


-4 


Off 


Off 


Skip 2 Instructions 


-6 


+6 


Off 


On 


Skip 2 Instructions 


-0 


+0 


Off 


On 


Skip 2 Instructions 


+0 


-0 


Off 


On 


Next Instruction 


+6 


-6 


Off 


On 


Next Instruction 


+6 


+4 


Off 


Off 


Next Instruction 


+6 


+6 


Off 


On 


Skip 1 Instruction 


+6 


+7 


On 


On 


Skip 2 Instructions 



Logical Compare Accumulator with Storage LAS -0340(1, E, L) Figure 5.3-37 

This instruction compares the contents of the AC (P, 1-35) with the logical word (S, 1-35) 
stored at location X. The sign of the AC is disregarded; the contents of the AC and 
storage are unchanged. 

If the contents of the AC are greater than the contents of storage location X, the 
computer takes the next instruction in sequence. If the AC equals storage, the computer 
skips one instruction. If the contents of the AC are less than the contents of storage, 
the computer will skip the next two instructions. 

This instruction is executed the same as CAS, except that the signs are not used for 
an algebraic comparison and AC(P) is compared against SR(S). 

Plus Sense PSE +0760. . . XXXX(I, L) 

This instruction provides a means to test the status of any of the six sense switches, 
to turn on or off the four console sense lights, and to permit the transmission of an 
impulse to or from the exit or entry hubs of either the printer or punch. 

The address portion of the instruction determines whether a light, switch, printer, 
or card punch is being sensed; further, it determines* which light, switch, or hub is 
being sensed. The octal addresses for the different sense instructions are: 

Address Instruction 

0140 Turn off all sense lights (Figure 5.3-38) 

0141-0144 Turn on sense light 1, 2, 3, or 4, respectively (Figure 

5.3-39) 



102 



I Time 
Pri Op 76 



SR(18-35) -*AD 
(P-17) I9(D3) 

2.12.16.1 



I 



AD(3-17) -» 
I 9 (D3) 
3.06.16.1 

— tz 



■AS 



AS(12-17)-»»SC 
lll(Dl) 
2.11.78.1 



J 



L Time 



Sense Op Pnl 
Class Adr A14 

3.02.01 .1 



UA00 



3.03.00.1 



Turn Off Sense 
Lights Lll(Dl) 
2.09.60.1 



I Time 
Pri Op 76 



SR(18-35)-*-AD 
(P-17) I9(D3) 

2.12.16.1 



AD(3-17)*»AS 
1 9 (D3) 
3.06.16.1 

nz 



AS(12-17)-vSC 
I 11(D1) 
2.11.78.1 



L Time 

~T~ 



Sense Op Pnl 
Class Adr A14 

3.02.01 .1 

nz 



UA 1,2,3, or 4 

3.03.01 .1 
-K3.03.04.1 



Turn On Sense 
Light 1,2,3, 
or 4 

2.09.60.1 



1 Time 
Pri Op 76 



SR(18-35)-»AD 
(P-17) I9(D1) 

2.12.16.1 



AD(3-17)-> 
I 9 (D3) 
3.06.16.1 



AS 



AS(12-17)-* 
lll(Dl) 
2.11.78.1 



•SC 



L Time 
I 





I 


Sense Op Pnl 
Class Adr B16 

3.02.01 .1 




UA 1,2,3,4, 
5 or 6 
3.03.01 .1 
♦3.03.06.1 












Sense Skip 
L9(D1) 

2.09.59.1 

T~ 



Advance PC 
2.11.50.1 



End Op 



FIGURE 5.3-38. PSE +0760. . .0140 



FIGURE 5.3-39. PSE +0760. . .0141 , 0142, 0143, 0144 



FIGURE 5.3-40. PSE +0760. . .0161 , 0162, ETC. 



Address 
0161- 0166 



1341- 
2341- 
3341- 
4341- 
5341- 
6341- 
7341- 
10341- 



■ 1342 

• 2342 

■ 3342 

■ 4342 

■ 5342 
6342 

• 7342 
■10342 



Instruction 

If the corresponding sense switch is down (on), the 
computer skips the next instruction. If the sense switch 
is up (off), the computer takes the next instruction in 
sequence (Figure 5.3-40). 

The computer causes an impulse to appear at the specified 
exit hub of the control panel of the card punch attached to 
Data Channel A, B, C, D, E, F, G, or H respectively 
(Figure 5. 3-41). 



1360 
2360 
3360 
4360 
5360 
6360 
7360 
10360 



If an impulse is present at the entry hub of the control 
panel of the printer attached to Data Channel A, B, C, D, 
E, F, G, or H respectively, the computer skips the next 
instruction. If there is no impulse, the computer takes 
the next instruction in sequence (Figure 5.3-42). 



1361- 
2361- 
3361- 
4361- 
5361- 
6361- 
7361- 
10361- 



• 1372 

■ 2372 

■ 3372 

• 4372 

■ 5372 

• 6372 
7372 

10372 



The computer causes an impulse to appear at the specified 
exit hub of the control panel of the printer attached to Data 
Channel, A, B, C, D, E, F, G, or H, respectively 
(Figure 5.3-43). 



Minus Sense 



MSE -0760. . .XXXX(I,L) Figure 5.3-44 



If the sense light, on the operator's console, corresponding to the address portion 
of the instruction is on, this light is turned off and the computer skips the next instruc- 
tion. If the sense light is off the computer takes the next instruction in sequence. 
Addresses 0141-0144 correspond to sense lights 1-4, respectively. 



Input-Output Check Test 



IOT +0760. . .0005 (I, L) 



Figure 5. 3-45 



If the I-O check trigger is on, the indicator is turned off and the computer takes the 
next instruction in sequence. If the I-O check indicator is off, the computer skips the 
next instruction. 



Divide Check Test 



DCT +0760. . .0012 (I, L) 



Figure 5. 3-35 



This instruction examines the status of the divide check trigger. If the trigger is 
off, the next instruction is skipped. If the trigger is on, it is turned off and the computer 
takes the next instruction in sequence. 



104 



I Time 
Pri Op 76 



SR(18-35)-*AD 
(P-17) 19 (D3) 

2.12.16.1 



AD(3-17)- 
AS I 9 (D3) 
3.06.16.1 
EZZ 



AS(10-17) 
^SCIll(Dl) 
2.11 .78.1 



J 



L Tin 



O 
Cn 




Produce Out- 
put from Punch 
Sense Ctrl Panel 
Hub 1 or 2 



End Op 



I Time 
Pri Op 76 



I Time 
Pri Op 76 



SR(18-35)-*AD 
(P-17) 19 (D3) 

2.12.16.1 
♦ 



SR(18-35) 
-*AD (P-17) 

2.12.16.1 



AD(3-17) -» 
AS I 9 (D3) 
3.06.16.1 



AS(10-17) 
-*SC lll(Dl) 
2.11 .78.1 



T 



£ 



AD (3-17) 
*AS I9(D3) 

3. 06.16.1 
v 



1 



AS(10-17) 

-►sciihdi; 

2.11.78.1 



L Tin 



L Tii 



Select Channel 

6.00.05.1 
-»-6. 00.07.1 




Select Channel 

6.00.05.1 
-^6.00.07. 1 




UA (1-12) 
3.03.01 .1 
♦3.03.12.1 



No 



'Produce Output 
from one of the 1 0^ 
Printer Sense Ctrl 

.Panel Hubs 



End Op 



End Op 



FIGURE 5.3-41. PSE +0760. .. 1341 , 2342, 3341, ETC. 



FIGURE 5.3-42. PSE +0760. .. 1360, 2360, ETC. 



FIGURE 5.3-43. 



PSE +0760... 1361, 1372, 2361, 2362, ETC. 



I Time 
Pri Op 76 



I Time 
Pri Op 76 



SR(18-35)-*AD 
(P-17) 19 (D3) 

2.12.16.1 



AD(3-17) 
AS 19 (D3) 
3.06.16.1 

— 



L Time 



1 



AS(12-17) 
SC lll(Dl) 
2.11 .78.1 

T 



Sense Op Pnl 
Class Adr A14 

3.02.01 .1 



Turn Off Sense 
Light Lll(Dl) 

2.09.60.1 



UAl,2,3or4 

3.03.01 .1 
-3.03.04.1 



Sense Skip 
L9(D1) 

2.09.59.1 



Advance PC 



2.1 1 .50.1 




SR(18-35) ->AD 
(P-17) 19 (D3) 

2.12.16.1 



AD(3-17)-» 
AS 19 (D3) 
3.06.16.1 



L Tin 



1 



AS(12-17)-». 
SC 1 1 1 (D3) 
2.11.78.1 



J 



Yes 



Turn Off I/O 
Ck Tgr Lll(Dl) 

2.10.53.1 



UA 05 



3.03.05.1 




To Sense Skip 
DOT Or 

2.09.58.1 



Sense Skip 
L9(D1) 

2.09.59.1 



Advance PC 
2.11 .50.1 



End Op 



End Op 



FIGURE 5.3-44. MSE - 0760 .. .0141 , 0142, 0143, 0144 



FIGURE 5.3-45. I OT +0760. . .0005 



106 



Beginning-of-Tape Test BTT +0760. . . XXXX (I, L) Figure 5. 3-46 



This instruction tests the status of the beginning-of-tape indicator in a particular 
data channel. Address 1000-10000 selects data channels A-H respectively. If the 
beginning-of-tape indicator for the selected channel has been turned on by a previous 
instruction, the indicator is turned off and the computer takes the next instruction in 
sequence. If the indicator is already off, the computer skips the next instruction. 

End-of-Tape Test ' ETT -0760... XXXX (I,L) Figure 5.3-46 

This instruction uses address 1000-10000 to select the data channel in which the 
end-of-tape indicator is to be tested. If the indicator is on, it is turned off and the 
computer takes the next instruction in sequence. If the indicator is off, the computer 
skips the next instruction. 

5. 3. 08 Control Instructions 

Control instructions are provided so the programmer may change the problem condi- 
tions or service the computer. 

Halt and Proceed HPR +0420 (I, L) Figure 5. 3-47 

This instruction causes the computer to stop at the end of I time. When the start 
button is depressed, the computer proceeds to the next instruction in sequence. When 
halted, the PC contains the address of the next sequential instruction. 

Halt and Transfer HTR +0000 (I, L) Figure 5. 3-48 

This instruction causes the computer to stop at the end of I time by turning on the 
master stop trigger at Iio(Dl). Depressing the start button causes the computer to 
proceed in L time of a transfer operation and the computer takes an instruction trans- 
fer to location X. When halted, the PC contains the address of the HTR instruction. 

No Operation NOP +0761 (I,L) 

The NOP instruction performs no active function, but is used to reserve space for 
other instructions. Since this instruction has a primary operation 76, an I and an L 
cycle are required. The only function of this instruction is to turn on the end operation 
trigger to allow the computer to proceed to I time of the next sequential instruction. 
SOD Ol on Systems 3. 07. 01. 1 causes L END OP on Systems 8. 00. 09. 1. 

Execute XEC +0522 (I) Figure 5.3-49 

This instruction causes the computer to perform the instruction at location X. The 
program counter is not altered; therefore, after the instruction at location X has been 
executed, the computer proceeds to the next sequential instruction (instruction in next 
position beyond the XEC instruction). XEC prevents AR to PC on Systems 3. 06. 05. 1. 

If the instruction at location X is an unconditional transfer or a successful conditional 
transfer, the computer does not proceed to the next instruction following the XEC, but 
proceeds to the address specified by the transfer. Another exception occurs when the 
instruction at location X is a skip type, and the conditions are met for this skip. The 
PC is stepped and the skip is in relation to the location of the XEC instruction. 

Set Sign Plus SSP +0760. . . 0003 (I, L) Figure 5. 3-50 

This instruction places a zero (a plus) in the accumulator sign position. Positions 
(Q-35) of the accumulator are unchanged. 



107 



BTT 
6.01.10.1 



I Time 
Pri Op 76 



ETT 
6.01 .10.1 



L Time 



Channel 
Address 
6.00.05.1 



BTT and 
Channel Adr 
60.20.05.1 



ETT and 
Channel Adr 
60.20.05.1 




Turn On Ind 
Sync Tgr LI (D2) 

60.32.03.1 



Sense 
L9(D 

2.0? 


Skip 
1) 

.59.1 






Advan 
2.11 


ce PC 
.50.1 



End Op 



BTT 




ETT 



Turn Off BOT 
Ind 1 2 (D2) 

60.32.02.1 



Turn Off EOT 
Ind 12 (D2) 

60.32.02.1 



FIGURE 5.3-46. BTT +0760, ETT -0760 



I Time 
Pri Op 42 



T 



Halt Ctrl 
8.00.33.1 



Turn On Prog 
Stop Tgr (110) 
4.20.11.1 



Turn On Mst Stop 
Tgr I 10 (Dl) 
4.20.11.1 



B Cycle 
Interrupt 
8.00.13.1 



Prevent l,E, and' 
L Time 

8.00.18.1 
8.00.19.1 
8.00.20.1 



L Time Call 

I 9(D3) 
8.00.16.1 



Go To 
L Time 
8.00.12.1 



Turn On Mst L 
Time Tgr I 11(D1) 
8.00.20.1 




Turn On Start 
Tgr A0->A8 

4.20.07.1 



Intlk Reset 



4.20.12.1 



Turn On 
End Op Tgr 
8.00.09.1 



Go To 
I Time 
8.00.12.1 



Turn Off Mst L 
Time Tgr Al 1 
(Dl) 

8.00.20.1 



Turn Off Mst 
Stop Tgr A6(D1) 

4.20.11 .1 



Turn Off B Cycle 
Interrupt All (Dl) 
8.00.13.1 



1 



Turn Off Prog 
Stop Trigger 
4.20.11.1 



Gate Out 
"L" Cycle 



Turn On Mst I 
Time Tgr Al 1 
(Dl) 

8.00.18.1 



FIGURE 5.3-47. H PR +0420 



1 Time 




Pri Op 00 








Halt Ctrl 




8.00.33.1 





/Prevent PC \ 
[Advance 19 (Dl) 

V 2. 11. 51.1 ) 



Turn on Mst Stp 
Tgr 110 (Dl) 

4.20.11.1 



B Cycle 
Interrupt 

8.00.13.1 



L Time 


Call 


8.00 


.16.1 






Go To 




L Time 


8.00. 


12.1 



Turn On Mst L 
Time Tgr I 1 1 
(Dl) 

8.00.20.1 



AD(3-17) -*• 
AS 19 (D3) 
3.06.16.1 



'Prevent l,E, anc 
L Time 

8.00.18.1 
8.00.19.1 
8.00.20.1 




Minus on TR 
Met Ln 2 L9 
(Dl) 
2.10.09.1 

\ 



AR-^PC 
L9 (Dl) 
3.06.05.1 
1 



End Op 



AS AR 
111 (Dl) 
3.06.18.1 



FIGURE 5.3-48. HTR + 0000 



109 



I Time 
Pri Op 52 



SR(18-35)-»AD 
(P-17) I9(D3) 

2.12.16.1 



Prevent PC 
Advance 
I9(D1) 
2.11.51.1 



Prevent 
PC-*AS 
I9(D3) 
3.05.09.1 



AD(3-17)-*AS 
I9(D3) 

3.06.16.1 

L 



AS ->AR 
lll(Dl) 

3.06.18.1 



End Op 
8.00.02.1 



Prevent 
AR-*PC 
13 (Dl) 
3.06.05.1 



SSP 



Set AC(S) 
Plus 

2.09.57.1 



I Time 
Pri Op 76 



L Time 



End Op 



I Time 
Next Inst 




Inst 



SSM 



Set AC(S) 
Minus 

2.09.57.1 









Set AC(S) 
I6(D1) 

2.12.92.1 





I Time 
Pri Op 76 



L Tin 



End Op 



Set AC(S) 
Minus I6(D1) 

2.12.92.1 




Set AC(S) 
Plus I6(D1) 

2.12.92.1 



FIGURE 5.3-49. XEC + 0522 



FIGURE 5.3-50. SSM - 0760. . .0003; SSP + 0760. . .0003 



FIGURE 5.3-51. CHS +0760. . .0002 



Set Sign Minus 



SSM -0760. . . 0003(1, L) Figure 5. 3-50 



This instruction places a one (a minus) in the accumulator sign position. Positions 
(Q-35) of the accumulator are unchanged. 

Change Sign CHS +0760. . . 0002(1, L) Figure 5. 3-51 

This instruction complements the sign position of the accumulator. A one is re- 
placed by a zero and a zero is changed to a one. Positions (Q-35) of the accumulator 
are unchanged. 

5. 3. 09 Sense Indicator Instructions 

The sense indicator instructions are a group of instructions which operate on the sense 
indicator register. These instructions enable the computer to set and test the indicators 
under program control. 

Load Indicators LDI +0441(1, E) Figure 5.3-52 

The contents of storage location X (S,l-35) are placed in indicator positons (0-35). 
The contents of storage are unchanged. 

Store Indicators STI +0604(1, E) 

The contents of indicator positions (0-35) replace the contents of storage location X. 
The indicators are unchanged. Execution of this instruction is the same as STO 
(Figure 3. 5-1, Section 3. 5. 01) except that SI(0-35) is taken to the SR rather than AC 
(S, 1-35). SI(0-35) to the SR(S, 1-35) is shown on Systems 2. 12. 13. 1. 

OR Storage to Indicators OSI +0442(1, E) Figure 5. 3-52 

This instruction places the logical OR of the word at storage location X and the 
contents of the indicators in the sense indicator register. Storage is unchanged. 

Invert Indicators from Storage IIS +0440(1, E) Figure 5. 3-52 

This instruction inverts the positions of the SI register which have corresponding 
"1" bits in the word at storage location X. 

Reset Indicators from Storage RIS +0445(1, E) Figure 5.3-53 

This instruction utilizes the word at storage location X to reset the sense indicator 
register position. A "1" bit in any position of the word causes the corresponding sense 
indicator trigger to be turned off. Indicator positions which correspond to "0" bits are 
unchanged. Storage is unchanged. 

Set Indicators of Right Half SIR +0055(1) Figure 5.3-54 

For this instruction, the control field (18-35) of the instruction is OR'ed with the 
right half of the sense indicator register. A "1" bit in either the control field or the 
indicator places a "1" bit in the corresponding sense indicator. Because the only 



111 



I Time 
Pri Op 44 



E Tir 



IIS, OSI 



SR Output- 
Hanging on 

Input to SI 




Electronic Reset 
of SI E0(D3) 

2.12.64.1 



SB -* SR 
E7(D1) 
2.12.50.1 



Inst 



Dl 
OSI 



Set SI 

E10(D1) 

2.12.63.1 




IIS 









Invert SI 
E10(D1) 
2.12.61 .1 



I Time 
Pri Op 44 



E Time 

ZfZ 



SB -»-SR 
E7(D1) 
2.12.50.1 



SR Output 
Hanging On 
Input to SI 



Reset SI 
E10(D1) 

2.12.62.1 



'Each SI PositionA 
Corresponding to a\ 
Position of the SR ) 
Containing a IBit/ 
is Reset / 



^Set SI Posi- \ 
tion for Bit 1 
in SR Position J 



f Invert SI Posi- 
tion for Bit in 
^ SR Position 



FIGURE 5.3-52. LDI +0441; OSI +0442; IIS +0440 FIGURE 5.3-53. RIS +0445 



112 



1 Time 
Pri Op 04 



End Op 



I Time 
Next Inst 



SIR,RIR,IIR 



SR(18-35) ->AD 
(18-35) I0(D3) 

2.12.14.1 




Inst 



SIL, RIL, ML 



SR( 18-35) AD 
(P-17) I0(D3) 

2.12.16.1 

~3 



AD(P-35)-*-SR 
(S-35) I2(D1) 

2.12.04.1 



SR Output 
Hanging on 
SI Input 



RIR.RIL 







Reset SI 

I4(D1) 

2.12.62.1 





Inst 




SIR, SIL 



IIR, IIL 



Invert SI 
I4(D1) 
12.12.61 .1 



Set SI 
14 (Dl) 
2.12.63.1 



Reset SI Position 
for Bit in SR 
Position 




FIGURE 5.3-54 SIR + 0055; SIL - 0055; RIR + 0057; 

RIL - 0057; IIR + 0051; IIL - 0051 



113 



input to the sense indicator register is from the SR, the control field must be placed in 
the right half of the SR, and the left half of the SR must be cleared before setting the 
indicators. This is accomplished by gating only the right half of the SR to the adders 
and then gating adders (P, 1-35) to SR(S, 1-35), 

Set Indicators of Left Half SIL -0055 (I) Figure 5. 3-54 

This instruction OR's the control field (18-35) of the instruction with the left half of 
the sense indicator register. Execution is the same as SIR except that the control field 
must be switched to the left half of the SR, and the right half of the SR must be cleared 
before the indicators can be set. This is done by routing SR(18-35) to AD(P-17). 

Reset Indicators of Right Half RIR +0057 (I) Figure 5.3-54 

This instruction causes the reset of the positions of the right half of the sense indica- 
tor register which correspond to ones in the control field (18-35) of the instruction. 
Indicator positions corresponding to zeros are unchanged. Execution of this instruction 
is identical to SIR, except that the reset-indicators input is used instead of set indicators. 

Reset Indicators of Left Half RIL -0057 (I) Figure 5.3-54 

For this instruction, the control field of the instruction is used as a reset mask for 
the left half of the indicator register. A one in the control field resets the correspond- 
ing indicator position. Execution of this instruction is similar to that of SIL except that 
the re set -indicators pulse is used. 

Invert Indicators of Right Half IIR +0051 (I) Figure 5.3-54 

This instruction inverts positions of the right half of the indicator register which 
correspond to ones in the control field of the instruction. Indicator positions corre- 
sponding to zeros in the control field are unchanged. Execution is identical to that of 
SIR except that the invert-indicators pulse to the indicator input is used. 

Invert Indicators of Left Half IIL -0051 (I) Figure 5.3-54 

This instruction inverts positions of the left half of the indicator register which 
correspond to ones in the control field (18-35) of the instruction. Indicator positions 
corresponding to zeros in the control field are unchanged. Execution of this instruction 
is identical to that of SIL, except that an invert -indicators pulse is used. 

Place Indicator in Accumulator PIA -0046 (I) Figure 5. 3-55 

The contents of sense indicators (0-35) are placed in positions (P,l-35) of the 
accumulator. The sense indicators are unchanged. AC positions Q and S are cleared. 

Place Accumulator in Indicators PAI +0044 (I) Figure 5. 3-55 

The contents of the accumulator (P, 1-35) are placed in the sense indicator register. 
The accumulator is unchanged. 



114 



PIA 



SI-*SR 
I0(D6) 
2.12.13.1 



SR(S-35) -»-AD 
(P-35) I4(D3) 

2.12.15.1 



AD(Q-35) 
I6(D1) 
2.12.31 .1 



AC 



I Tiitie 
Pri Op 04 



End Op 



I Time 
Next Inst 




PAI Inst. 
Yes 



No 



Electronic Reset 
of SI 12 (Dl) 

2.12.64.1 




Inst 



IIA, RIA, OAI, PAI 



AC(P-35) -*>SR 
(S-35) I2(D1) 

2.12.02.1 



RIA 







Reset SI 

I4(D1) 

2.12.62.1 





Inst 




IIA 



Invert SI 
I4(D1) 
2.12.61 .1 



Reset SI Position 
for Bit in SR 
Position 




Invert SI Position 
for Bit in SR 
Position 



' SR Output 
Hanging on SI 
l Input 



OAI, PAI 









Set SI 
I4(D1) 
2.12.63.1 




Set SI Position 
for Bit in SR 
Position 



FIGURE 5.3-55. PAI +0044; PIA - 0046; OAI +0043; 
RIA - 0042; IIA +0041 



115 



OR Accumulator to Indicators 



OAI +0043 (I) 



Figure 5. 3-55 



The logical OR of the contents of the accumulator (P, 1-35) and the indicators is 
placed in the sense indicator register. If a position in either register contains a one, a 
one will be placed in that position of the indicator. The accumulator is unchanged. Exe- 
cution is accomplished using the sequence of PAI but omitting the indicator reset. 

Reset Indicators from Accumulator RIA -0042(1) Figure 5.3-55 

The positions of the sense indicator register which correspond to the positions of 
the AC (P, 1-35) having "1" bits are reset to zero. Indicator positions which correspond 
to "0" bits are unchanged. The AC is unchanged. 

Invert Indicators from Accumulator IIA +0041(1) Figure 5.3-55 

This instruction inverts any sense indicator position for which there is a corre- 
sponding "1" bit in the accumulator (P,l-35). 

Transfer if Indicators On TIO +0042 (I, L) Figure 5. 3-56 

If all of the ones in the AC are matched by ones in the indicator register, an instruc- 
tion transfer is taken to location X. AC positions containing zeros are not compared with 
indicator positions. If all of the ones are not matched, the computer takes the next 
instruction in sequence. To execute this instruction, the complement of the AC is 
OR'ed with the indicator. If the ones match, the result will be all ones. The result 
of the OR is stored in the SR and fed to the adder. A carry to adder (35) will ripple 
down the adder and carry out of the AD(P). The adder (P) carry is used to condition 
the transfer. 

Transfer if Indicators Off TIF +0046(1, L) Figure 5.3-56 

If all of the ones in the AC are matched by zeros in the indicator register, an instruc- 
tion transfer is taken to location X. AC positions containing zeros are not compared 
with indicator positions. If all of the ones are not matched, the computer takes the 
next instruction in sequence. Execution of this instruction is identical to that of TIO, 
except that the complement of the indicators is OR'ed to the complement of the AC. 
Test procedure remains the same. 

On Test for Indicators ONT +0446 (I, E, 2L) Figure 5.3-57 

If the ones contained in the word stored at location X are matched by ones in the 
corresponding indicator register positions, the next instruction will be skipped. If all 
of the ones are not matched, the computer will take the nexi instruction in sequence. 
Positions of storage location X which contain zeros are not compared. Execution of 
this instruction requires an E cycle to obtain the test word from storage and two L 
cycles to complete the test. The test is accomplished by moving the test word to the 
accumulator, where it can be complemented. The complement is OR'ed with the in- 
dicators and returned to the SR. The result of the OR will be all ones if the ones in 
the test word match the indicator. To test for all ones a carry is added to the OR which 
will result in an adder (P) carry to condition the advance instruction counter. The 
contents of the accumulator are saved and restored to normal during execution of the 
instruction. 



116 



I Time 
Pri Op 04 

Any Trans or 
Store and Trap 

2.11.55.1 



Trans Cndtl 
AD-AS 
2.10.09.1 



* 








SR (18-35) — *• 




AD(3-17) -*-AS 




AS -*AR 


AD (P-17) 




I9(D3) 




lll(Dl) 


19 (D3) 




3.06.16.1 




3.06.18.1 



2.12.16.1 
I 



L Time 



Comp AC(Q-35) 
-*-AD L0(D3) 

2.12.22.1 




AD(P-35) -*SR 
(S-35) L2(D1) 

2.12.04.1 



SR(S-35) -*-AD 
(P-35) L5(D6) 

2.12.15.1 



Carry -»-AD(35) 
L5(D6) 

2.12.29.1 




FIGURE 5.3-56. TIO + 0042; TIF + 0046 



117 



I Time 
Pri Op 44 



E Ti 



SB -*SR 

E7(D1) 

2.12.50.1 



1st L 
Time 



SR(S-35) -*-AD 
(P-35) L0(D3) 

2.12.15.1 



AD(Q-35) 
-►AC L2(D1) 
2.12.31 .1 



AC(Q-35)-*>SR 
(Q,S-35)L2(D1) 

2.12.01 .1 
l 



Comp AC (Q-35) 
-*AD L4 (D3) 
2.12.22.1 



AD (Q-35)-* 
AC L6 (Dl) 
2.12.31 .1 



SR(S-35) -*-AD 
(P-35) L8(D3) 

2.12.15.1 



AD (Q-35)-*- 
AC L10 (Dl) 
2.12.31.1 



SR (Q)-*AC (Q) 
L10 (Dl) 
2.12.38.1 



AC(Q-35)*SR 
(Q,S-35)L10 (Dl) 

2.12.01 .1 




ONT 



Inst 



SI -*SR 
L9 (D3) 
2.12.13.1 
EZZ 



OFT 

Comp SI-»-SR 
L9 (D3) 
2.12.12.1 



2nd 

L Time 

2.12.18.1 



SR(S-35) -*AD 
(P-35) L5 (D6) 

2.12.15.1 



Carry -*AD 
(35) L5 (D6) 
2.12.29.1 




AD(P) Can- 



Yes 



No 



SI Sk 
L9 (C 
2.10 


P 
1) 

36.1 




Advar 
2.11 


ce PC 
.50.1 



FIGURE 5.3-57. ONT +0446, OFT +0444 



Off Test for Indicators 



OFT +0444 (I,E,L,L) Figure 5.3-57 



If the ones contained in the word stored at location X are matched by zeros in the 
corresponding indicator positions, the computer will skip one instruction. If all of the 
ones are not matched by zeros, the computer will take the next instruction in sequence. 
Positions in the test word from storage which contain zeros are not compared. Execu- 
tion of this instruction is identical to that of ONT, except that the complement of the 
indicator is used for the OR operation instead of the true indicator. 

Right -Half Indicators, On Test RNT +0056 (I, L, L) Figure 5.3-58 

This instruction matches the ones in the control field (18-35) of the instruction 
against the corresponding positions of the right half of the indicator register. If all of 
the ones are matched by ones, the computer skips one instruction. If all are not 
matched, the computer takes the next instruction in sequence. Positions of the control 
field containing zeros are not compared. Execution of this instruction is the same as 
ONT except that only positions (18-35) of SR are used. 

Left-Half Indicators, On Test LNT -0056 (I, L,L) Figure 5.3-58 

If the ones in the control field of the instruction are matched by ones in the corre- 
sponding positions of the left half of the indicator register, the computer will skip the 
next instruction. If all ones are not matched, the computer takes the next instruction 
in sequence. Execution of this instruction is the same as ONT, except that the SR 
(18-35) is compared against SI(0-17). 

Right-Half Indicators, Off Test RFT +0054 (I, L, L) Figure 5. 3-58 

If the ones in the control field of this instruction are matched by zeros in the right 
half of the indicator register, the computer will skip one instruction. If all ones are 
not matched by zeros, the computer will take the next instruction in sequence. Posi- 
tions of the control field containing zeros are not compared. This instruction is exe- 
cuted the same as OFT, except that only positions (18-35) of the SR are used. 

Left-Half Indicators, Off Test LFT -0054 (I, L, L) Figure 5.3-58 

If the ones in the control field of this instruction are matched by zeros in the left 
half of the indicator register, the computer will skip one instruction. If all are not 
matched, the computer will take the next instruction in sequence. Positions of the 
control field containing zeros are not compared. The control field and the indicator 
register are unchanged. Execution of this instruction is the same as OFT, except that 
SR(18-35) is compared with SI(0-17). 

5. 3. 10 Index Transmission Instructions 

These are the instructions which operate on or with the index registers. They are 
used to load or modify the index registers, to alter instructions from the index regis- 
ters, or to control program flow. 

There are three shift cell index registers containing 15 positions each. The tag bit 
positions (18-20) of the instruction control which index registers are to be used. Any 



119 



I Time 
Pri Op 04 



1st L Time 



R NT, RFT 




Inst 



LFT, LNT 



SR(18-35) *AD 
(18-35) L0(D3) 

2.12.14.1 



SR(18-35)-»-AD 
(P-17) L0(D3) 

2.12.16.1 



AD(Q-35) -*AC 
L2(D1) 
2.12.31.1 



AC(Q-35)-*SR 
(Q,S-35) L2(D1) 

2.12.01 .1 



Comp AC(Q-35) 

->>ADL4(D3) 
' 2.12.22.1 



AD(Q-35)-**AC 
L6(D1) 
2.12.31.1 



SR (S-35)-AD 
(P-35) L8 (D3) 

2.12.15.1 



AD (Q-35)-* 
AC L10 (Dl) 
2.12.31.1 



SR(Q)-*>AC 
(Q) L10(D1) 

2.12.38.1 



AC(Q-35)-vSR 
(Q,S-35)L10(D1) 

2.12.01 .1 



2nd L Time 
2.12.08.1 



T 



SR(S-35) -*• AD 
(P-35) L5 (D6) 



1 



Carry -+-AD 
(35) L5 (D6) 
2.12.29.1 




SI Skip L9 
KD1) 
2.10.36.1 



Advance PC 
2.11.50.1 




RFT, LFT 



Comp SI ->SR 
L9 (D3) 
2.12.12.1 



FIGURE 5.3-58. RNT +0056; LNT - 0056; RFT +0054; LFT -0054 



index register or combination of index registers may be selected. The tag bits are N 
retained by the tag register on Systems 2. 08. 01. 1. SB(18-20) outputs are used to turn 
on the tag register triggers during I time of the instruction. The output of the index 
register, when gated to the adders, is always complemented. To make this a 2's 
complement, a carry is gated to adder (17) at the same time the XR is gated to the AD. 

Many instructions are indexable, as controlled by their tag positions, allowing the 
address portion of the instruction to be modified. Appendix A shows which instructions 
are indexable. 

Transfer with Index Incremented TXI +1000 (I, L) Figure 5.3-59 

This transfer adds its decrement to the specified index register and causes an un- 
conditional transfer to location X. The index register outputs are always complemented 
to the adders. Thus, to add the decrement, the index register must be cycled through 
the adders so they contain a complement before the addition. 

Transfer on Index TIX +2000 (I, L) Figure 5.3-60 

If the number in the specified index register is greater than the decrement, the 
contents of the index register will be reduced by the amount of the decrement, and an 
instruction transfer will be taken to storage location X. When the number in the index 
register is equal to or less than the decrement, no reduction is made and the computer 
takes the next instruction in sequence. The comparison between the index register 
contents and the decrement is made by gating the decrement and the 2's complement 
of the index register contents to the adders. No carry from adder (3) indicates that 
the index register contents are greater and that the transfer and index register reduc- 
tion are to be made. A carry from adder (3) will, therefore, block the transfer and 
index register reduction. 

Transfer on No Index TNX -2000 (I,L) Figure 5.3-60 

If the number in the specified index register is greater than the decrement, the 
contents of the index register, will be reduced by the amount of the decrement, and the 
computer will proceed to the next instruction in sequence. When the number in the 
index register is equal to or less than the decrement, no reduction is made, but an 
instruction transfer will be taken to storage location X. 

The sequence of operations for this instruction is like that of TIX, except that the 
conditional transfer circuits are activated with the adder (3) carry trigger on. 

Transfer on Index High TXH +3000 (I, L) Figure 5. 3-60 

If the number in the specified index register is greater than the decrement, an 
instruction transfer is taken to storage location X. If the number in the index register 
is less than or equal to the decrement, the computer takes the next instruction in 
sequence. Execution of this instruction is identical to that of TIX. Because no reduc- 
tion is to be made, the adders are not routed to the index registers. 



121 



I Time 



\ 

SB08-20) 
-►Tag Reg 
2.08.01 .1 



SR(18-35)-*AD 
(P-17) I9(D3) 

2.12.16.1 



AD (3-17)-* 
AS 19 (D3) 
3.06.16.1 



i 

AS-^AR 
lll(Dl). 
3.06.18.1 



L Ti 



Comp XR->AD 
L Time 

2.12.19.1 



AD (3-17)*XR 




L2 (Dl) 




2.12.70.1 






SR(S-35) -►AD 




(P-35) L4(D3) 




2.12.15.1 






AD (3-17)-^XR 


L6 (Dl) 


2.12.70.1 



I 



Index Trans 

Met 
02.12.76.1 

~~r~ 

AR-^PC 

L9(D1) 

3.06.05.1 

End Op 



FIGURE 5.3-59. TXI +1000 



Time 



SB(18-20) 
-►Tag Reg 
2.08.01 .1 



SR( 18-35) -►AD 
(P-17) 19 (D3) 

2.12.16.1 




AD(3-17)+-AS 

19 (D3) 

3.06.16.1 
| 



3_ 



AS-kAR 
111 (Dl) 
3.06.18.1 



L Time 

i 



Comp XR-^AD 
L Time 

2.12.19.1 

— ^£ZZ 



1 



Carry -►AD 
(17) L Time 
2.12.19.1 



SR(l-35)-^AD 
L0(D6) 
2.12.14.1 



(XR>Decr) 'p_<AD(3) Car^> Yes 
TXH,TXL /[^ 



TIX 
TNX 



AD(3-17)-^XR 
L5(D1), L10(D1) 
2.12.70.1 




Inst 



TIX 
TXH 



TNX 
TXL 



TNX 
TXL 



Index 

Met 

2.12 


Trans 
.76.1 






AR* 

L9(D1 
3.06. 


PC 

) 

05.1 




Inst 



End Op 



FIGURE 5.3-60. TIX +2000; TNX - 2000; TXH +3000; TXL -3000 



Transfer on Index Low or Equal TXL -3000 (I, L) Figure 5.3-60 

If the number in the specified index register is greater than the decrement, the 
computer takes the next instruction in sequence. If the number in the index register is 
equal to or less than the decrement, an instruction transfer will be taken to storage 
location X. Execution of this instruction is identical to that of TNX except that, because 
no reduction is required, the adders will not be routed to the index register. 

Transfer and Set Index TSX +0074 (I, L) Figure 5. 3-61 

This instruction places the 2's complement of the instruction counter (the location of 
the TSX instruction) in the specified index register and causes an instruction transfer 
to storage location X. Execution of this instruction requires, in addition to the normal 
transfer controls, the routing of the instruction counter to the index register. This 
involves use of the address switch, storage register, and adders. To obtain the re- 
quired 2 's complement, the index register contents must also be cycled through the 
adders after receiving the contents of the instruction counter. 

Place Address in Index PAX +0734 (I) Figure 5. 3-62 

This instruction places the contents of AC (21 -35) in the specified index register in 
true form. To shift the address field to the decrement positions of the adders, AC 
(21-35) is routed through the SR to AD(P-17). 

Place Decrement in Index PDX -0734 (I) Figure 5.3-62 

This instruction places the true contents of AC (3-17) in the specified index register. 
Because no shift is required to execute this instruction, AC(3-17) is sent to AD(3-17) 
through the SR. 

Place Complement of Address in Index PAC +0737 (I) Figure 5.3-62 

This instruction places the 2's complement of AC(21-35) in the specified index 
register. The AC is unchanged. The complementing is accomplished by putting the 
address in the XR and then cycling the XR through the adders. 

Place Complement of Decrement in Index PDC -0737 (I) Figure 5. 3-62 

This instruction loads the 2's complement of AC (3-17) in the specified index register. 
The AC is unchanged. The complementing is accomplished in the same manner as in 
PAC. 

Place Index in Address PXA +0754 (I) Figure 5.3-63 

This instruction places the true contents of the specified index register in AC (21 -35). 
Positions (S, Q, P-20) of the AC are cleared. To obtain the true contents of the index register 
for executing this instruction, the index register contents are cycled through the adders. 
The index register contents are then rerouted to the adders and routed to the storage 
register by way of the address switch to shift the index register contents to the address 
field. 



123 



I Time 
Pri Op 06 



T. 



SB(18-20) 
-*■ Tag Reg 
2.08.01.1 



SR(18-35)-*AD 
(P-17) 19 (D3) 

2.12.16.1 



Suppress PC 
Advance at 1 9 

2.11.51.1 









AD (3-17)* 
XR L10 (Dl) 
2.12.70.1 








Index Trans 

Met 
2.12.76.1 



T 



AD(3-17) 
-*AS 19 (D3) 
3.06. 16.1 



AS-*AR 
lll(Dl) 
3.06.18.1 

~ I 




L Time 

PC —AS 
L0(D3) 
3.05.09,1 



AS-*SR(21-35) 
L2(D1) 
3.06.12.1 

I 

SR(18-35)-*AD 
(P-17) L4(D3) 

2.12.16.1 
I 



AD(3-17) — XR 
L5(D1) 
2.12.70.1 





+ 








; 


Carry ->-AD 
(17) L8(D3) 
2.12.19.1 




XR-»*AD 

L8(D3) 

2.12.19.1 








i 





FIGURE 5.3-61. TSX +0074 



I Time 
Pri Op 72 



SB( 18-20) 
-»-Tag Reg 
2.08.01 .1 



SR(18-35) -*AD 
(P-17) I0(D3) 

2.12.16.1 



AC (S, 1-35) 
*SR I 10 (Dl) 
2.12.01.1 



End Op 



T. 



I Time 
Next Inst 



PAX, PAC ^, nsf 








5R (1-35)-*- 
AD 10 (D3) 
2.12.14.1 



AD (3-17)* 
XR I 2 (Dl) 
2.12.70.1 




Inst 



PAX 
PDX 



> 


> 






XR-*AD 
14 (D3) 
2.12.19.1 




Carry -►AD 
(17) I4(D3) 
2.12.19.1 



AD (3-17)* 
XR 16 (Dl) 
2.12.70.1 



FIGURE 5.3-62. PAX +0734; PDX -0734; PAC +0737; PDC-0737 



PXD 



AD(Q-35) 
-*AC |2(D1) 
2.12.31.1 



1 Time 




Pri Op 74 




♦ 


SB (18-20) 




-*Tag Reg 




2.08.01.1 





XR-*>AD 
19 (D3) 
2.12.19.1 




Prevent SR(18-35) 
-*AD(P-17) 19 (D3) 

2.12.16.1 


1 




AD(3-17) 
-*XR lll(Dl) 
2.12.70.1 





End Op 



± 



I Time 
Next Inst 



XR -VAD 
I0(D3) 
2.12.19.1 



Note: Tag =0 
Block XR ♦Adders 
10 (D3) 




MF Store 




Ctl 






2.09.00.1 





Inst 



PXA 



1 



AD (3-17)*XR 
I 2 (Dl) 
2.12.70.1 



MF Store 
Deer 

2.09.01 .1 



AD (3-17)-*AS 
10 (D3) 
3.06.16.1 

F~ 



AS — *SR 
12 (Dl) 
3.06.12.1 
— T~ 



Put Zeros in SR(l-20)by 
Operating Set and Hold Lines 
Zero Already in SR(S) 
AS Goes to SR(21-35) 



Plus to Acc(S) 
16 (Dl) 
2.12.92.1 



SR (S-35)-*AD 
(P-35) I 4 (D3) 
2.12.15.1 
I 



AD(Q-35) 
♦AC I6(D1) 
2.12.31.1 



I Time 
Pri Op 62 



I 



SB (18-20) 
-WTag Reg 
2.08.01 .1 



E Time 

~T~ 



fcR-*-AD 

E0(D6) 
2.12.19.1 

r 



AD (3-17) 
-►XR El (Dl) 
2.12.70.1 



SXD 




Inst 



SXA 



AD(P-35) -*-SR 
(S-35) E3(D1) 

2.12.04.1 



AD (3-17)*AS 
E2 (D2) 
3.06.16.1 



MF Store 

Adr 
2.09.01.1 



MF Store 

Ctl 
2.09.00.1 



AS-SR (21-35) 
E3 (Dl) 
3.06.12.1 



AD (3-17) 
-**R E5 (Dl) 
2.12.70.1 



X 



SR -*SB 

E4(D3) 

2.09.00.1 



SB *-Mem 
Data Reg 



FIGURE 5.3-63. PXA +0754; PXD -0754 



FIGURE 5.3-64. SXA +0634; SXD -0634 



125 



Place Index in Decrement 



PXD -0754 (I) 



Figure 5.3-63 



This instruction places the true contents of the specified index register in positions 
(3-17) of the AC. The remainder of the AC is cleared. Execution of this instruction 
is similar to PXA. However, because no shift is required, the index register contents 
can be routed directly from the adders to the AC. 

Store Index in Address SXA +0634 (I, E) Figure 5.3-64 

This instruction stores the true contents of the specified index register in the 
address field (21-35) of storage location X. The remaining positions of location X are 
unchanged. The logic of the execution of this instruction is similar to PXA. However, 
an E cycle is needed to put the information in core storage. 

Store Index in Decrement SXD -0634 (I, E) Figure 5.3-64 

This instruction stores the true contents of the specified index register in the 
decrement (3-17) of storage location X. The remaining positions of location X are 
unchanged. Execution of this instruction is similar to SXA but, because there is no 
shift required, the output of the adders goes directly to the SR. 

Address to Index True AXT +0774 (I) Figure 5.3-65 

This instruction loads the specified index register with the address field (21-35) in 
true form. 

Address to Index Complemented AXC -0774 (I) Figure 5.3-65 

This instruction loads the specified index register with the 2's complement of the 
address portion (21-35) of the instruction. Execution of AXC is similar to that of AXT 
except that the index register contents must be cycled through the adders during the 
following I cycle to obtain the 2's complement. 

Load Complement of Address in Index LAC +0535 (I, E) Figure 5.3-66 

This instruction loads the 2's complement of the address (21-35) of storage location 
X into the specified index register. Execution of this instruction requires an E cycle 
to obtain the word from storage. The address portion is transferred to the index regis- 
ter by way of the adders at the end of the cycle, and, to obtain the 2's complement, the 
index register is cycled during the following I cycle. 

Load Complement of Decrement in Index LDC -0535 (I,E) Figure 5. 3-66 

This instruction loads the 2's complement of the decrement field (3-17) of storage 
location X into the specified index register. Execution of this instruction is identical 
to that of LAC except that the SR decrement, instead of the address, goes to the adders. 

Load Index from Address LXA +0534 (I,E) Figure 5.3-66 

This instruction loads the specified index register with the contents of the address 
field (21-35) of storage location X in true form. Execution of this instruction is 
identical to that of LAC, except that the complementing operation is not required. 



126 



I Time 
Pri Op 76 

i 

SB(18-20)-* 
Tag Reg 
2.08.01.1 



SR(18-35)-*AD 
(P-17) I9(D3) 

2.12.16.1 



AD(3-17)-»*R 
lll(Dl) 
2.12.70.1 

i 

End Op 
I 

I Time 
Next Inst 











XR -> AD 
I0(D3) 
2.12.19.1 




Carry -»>AD 
(17) I0(D3) 
2.12.19.1 




AXT 





AD(3-17)-*XR 
12(D1) 

2.12.70.1 











FIGURE 5.3-65. AXT +0774; AXC - 0774 



I Time 
Pri Op 52 



SB(18-20) 
Tag Reg 
2.08.01 .1 



LXA, LAC 



SR(18-35)-*AD 
(P-17) E9(D3) 

2.12.16.1 



E Time 



Inst 




LXD, LDC 



SR(S-35)-*-AD 
(P-35) E9 (D3) 

2.12.15.1 



AD(3-17)-*XR 
Ell(Dl) 

2.12.70.1 



I 



End Op 



I Time 
Next Inst 



XR — AD 
I0(D3) 

2.12.19.1 



Carry AD 
(17) I0(D3) 

2.12.19.1 



Inst 




LXA, LXD 



LAC, 



LDC 



AD(3-17)-*XR 
I2(D1) 

2.12.70.1 



FIGURE 5.3-66. LXA +0534; LXD -0534; LAC +0535; LDC -0535 



Load Index from Decrement 



LXD -0534 (I, E) 



Figure 5. 3-66 



This instruction loads the specified index register with the contents of the decrement 
field (3-17) of storage location X in true form. Execution of LXD is identical to that of 
LDC, except that the complementing operation is not used. 

5. 3. 11 AND and OR Instructions 

The AND and OR instructions are used to produce logical combinations of bits. These 
are useful for masking or matching words. 

OR to Storage ORS -0602 (I, E) Figure 5.3-67 

This instruction stores the logical OR of the word stored at location X and the AC 
(P, 1-35) in location X. The logical OR is obtained by matching the two words and stor- 
ing ones in all positions which have ones in either word. For this instruction, the OR is 
developed in the memory data register during the E cycle. The words from core stor- 
age and the SB both go the memory data register and the result in the memory data regis- 
ter is put back into core storage. 

OR to Accumulator ORA -0501 (I, E) Figure 5. 3-68 

This instruction places the logical OR of the word stored at locationX andAC(P-35) in 
the accumulator. The OR is produced by matchingthe two words and placing ones in all 
positions of the AC which have ones in either word. The OR is developed in the SR by 
gating both the storage and AC words into the SRat the same time. S and Q remain unchanged. 

AND to Accumulator ANA -0320 (I, E, L) Figure 5.3-69 

This instruction places the logical AND of the word stored at location X and the AC 
(P, 1-35) in the accumulator (P, 1-35). The logical AND is obtained by matching the two 
words and placing ones in all positions of the accumulator which have corresponding 
ones in both the AC and storage. This instruction is executed by OR'ing the complement 
of both words and then complementing this sum. 

AND to Storage ANS +0320 (I, E, L, E) Figure 5.3-69 

This instruction stores the logical AND of the word stored at location X and the 
contents of the AC(P, 1-35) in location X. The logical AND is obtained by matching the 
two words and placing ones in all positions of storage location X which have corre- 
sponding ones in both the AC and storage. The contents of the AC(S, Q, P, 1-35) are un- 
changed. The AND is accomplished the same for this instruction as for ANA. An addi- 
tional E cycle is requiredto put the AND in storage. The complement of the original AC 
(P, 1-35) is returned to the AC and re-complemented to restore the contents of AC(P, 1-35). 
During the execution, the original AC(Q) is saved in SR(Q) and then returned to AC(Q). 

Exclusive OR to Accumulator ERA +0322 (I, E, L) Figure 5.3-70 

This instruction matches AC(P, 1-35) with the logical word stored at location X. Zeros 
replace all positions of the AC which match the corresponding positions of the logical 
word. Accumulator positions (S) and (Q) are cleared. 



128 



MF Store Ctrl 
2.09.00.1 




E Time 



AC(P-35) -*■ SR 
(S-35) E1(D1) 

2.12.02.1 



SR-*-SB 
E4 (D3) 
2.09.00.1 



Allow Core 
Word to Get to 
Mem Data Reg 



MF Store 
Prefix 

2.09.01.1 



MF Store 
Deer 



2.09.01 .1 



MF Store 
Tag 

2.09.01.1 



MF Store 
Adr 



2.09.01 .1 



Suppress 
SB*-SR 
E7 (Dl) 
2.12.50.1 



SB-*- Mem 
Data Register 



End Op 



FIGURE 5.3-67. ORS-0602 



1 Time 
Pri Op 50 






E Ti 


me 



SB — ► SR 

E7(D1) 

2.12.50.1 



AC(Q,P-35) 
-*>SR(Q,S-35) 
E7(D1) 

2.12.01.1 



SR(S-35) -*AD 
(P-35) E9(D3) 

2.12.15.1 
T 









AD(Q-35) -+-AC 
El 1 (Dl ) 
2.12.31.1 




SR(Q) -*AC 1 
(Q)Ell(Dl) 
2.1? 38.1 1 









End Op 



FIGURE 5.3-68. ORA-0501 



129 



I Time 
Pri Op 32 



Turn On 
ANA-ANS 
Tgr 19 
2.09.46.1 



E Time 



Comp AC(Q-35) 
AD E4(D3) 

2.12.22.1 



Comp Acc Content 



AD(Q-35) -*AC 
E6(D1) 

2.12.31 .1 



AC(Q)-*5R(Q) 
E6(D1) 

2.12.01.1 

1 — 



SB SR 
E7(D1) 

2.12.50.1 



SR(S-35)-»-AD 
(P-35) E9(D3) 

2.12.15.1 



Exchange SR & ACC 



AC(P-35) -*SR 
(S-35) Ell(Dl) 

2.12.02.1 



AD(Q-35)-*AC 
Ell(Dl) 

2.12.31 .1 



L Tin 



Comp AC(Q-35) 
-•►AD L0(D3) 

2.12.22.1 



Comp SR Content 



AD(Q-35) -*AC 
L2(D1) 

2.12.31 .1 



SR(S-35) -»-AD 
(P-35) L4(D3) 

2.12.15.1 



Exchange SR & ACC 



AD(Q-35)-*-AC 
L6(D1) 
2.12.31 .1 



AC (P-35)-*-SR 
(S-35) L6(D1) 
2.12.02.1 



Get Comp of 
Orginal AC 
Word Back 
to AC to Allow 
Restoring of Acc 
For "ANS" 



AC(P-3b)*!>R 
(S-35) 17 (Dl) 
2.12.02.1 



SR(S-35) -*-SR 
(S-35) L7 (Dl) 
2.12.11.1 

r 



Form Comp of 
"And" in SR 



Exchange SR & ACC 



Comp of AND 
in AC 




V>^1 








Reset ANA 








ANS Tgr 




E Time 




Lll (Dl) 




2.09.06.1 




2.09.46.1 



Recomplement "And" 



AND in AC 



AD(P-35) -*AC 


Set Acc 




5R(S-35)-*AD 


I2(D1) 


(S) Plus 




(P-35) E2(D2) 


2.12.30.1 


16 (Dl) 




2.09.40.1 




2.12.15.1 



Exchange SR & ACC 



AD(Q-35)*AC 
E3 (Dl) 

2.12.31.1 



AC(P-35)-*- SR 
(S-35) E3(D1) 

2.12.02.1 



AND in SR 



SR -»-SB 

E4(D3) 

2.09.00.1 



End Op 
2.09.46. 1 



I Time 



Comp AC(Q-35) 
*AD 10 (D3) 

2.12.22.1 
♦ 



Restore Original ACC 



AD(P-35) -*-AC 
I2(D1) 



2.12.30.1 



SR(Q)-*AC(Q) 
I2(D1) 

2.12.38.1 



FIGURE 5.3-69. ANA-0320; ANS +0320 



130 



I Time 
Pri Op 32 



E Tin 



SB— +SR 
E7(D1) 

2.12.50.1 







AC(Q-35)-*AD 




SR(S-35) -*AD 


E9(D3) 




(P-35) E9(D3) 


2.12.24.1 




2.12.15.1 



Sum in 
AC 



AD(P-35) 
Ell(Dl) 

2.12.30.1 



.AC 



Comp of Sum 
in SR 



AC(P-35)— »>SR 
(S-35) Ell(Dl) 

2.12.02.1 



SR(S-35) SR 
(S-35)E11(D1) 

2.12.11 .1 



OR 

in 

SR 



L Tii 



Comp AC(Q-35) 
AD L0(D3) 

2.12.22.1 



Comp of Sum 
for Subtraction 



AD(P-35)- 
L2(D1) 

2.12.30.1 



►AC 



SR(S-35)->AD 
(P-35) L4(D3) 

2.12.15.1 



AC(P-35) ->SR 
(S-35) L6(D1) 

2.12.02.1 



AD(P-35) 
L6(D1) 



AC 
2.12.30.1 



OR in AC 



SR(S-35)-*AD 
(P-35) I4(D3) 

2.12.15.1 



2(OR) - (Comp of Sum) 



Sh AC(F 
L8(D1) 

2.12 


-35) Lt 
.34.1 






End Op 






1 Tin 





2 (OR) in AC 



AC(Q-35)-*-AD 
14 (D3) 

2.12.24.1 



Carry AD 
(35) I4(D3) 

2.12.29.1 



AD(P-35)-*AC 
I6(D1) 

2.12.30.1 



Exclusive OR 



Note: Clear Acc(Q) 



Set Acc 
(S) Plus 
16 (Dl) 
2.09.40.1 



FIGURE 5.3-70. ERA +0322 



131 



Logically speaking, the EXCLUSIVE OR is the result of OR'ing bits from either one 
word or the other, but not both. The computer, which can only AND and OR, makes 
use of the following logical equation to develop the EXCLUSIVE OR: 

EXCLUSIVE OR = 2 (A or B) - ( A + B) 

The derivation of the above equation can be shown with the following adder table: 



Factor A 


0 


0 


0 


1 


1 


Factor B 


0 


0 


1 


0 


1 


A -i- B (carry not blocked) 


0 


1 


0 


0 


0 


Carry to be blocked 


0 


0 


0 


1 


0 


A + B (carry blocked) 


0 


0 


1 


1 


0 


EXCLUSIVE OR (A + B carry blocked) 


0 


0 


1 


1 


0 


A or B 


0 


0 


1 


1 


1 


2 (A 4- B) 


1 


0 


0 


0 


0 


2 (A or B) 


0 


1 


1 


1 


0 



From the table it can be seen that the EXCLUSIVE OR is equal to the sum output of 
the adders with all carries blocked. The carries cannot be blocked, but the EXCLUSIVE 
OR can be obtained by subtracting an amount equal to the blocked carries from the sum 
of two words: 

1. EXCLUSIVE OR = ( A + B) - blocked carries 

The blocked carries can be simulated by subtracting twice the OR from twice 
the sum of two words: 

2. Blocked carries = 2 (A + B) - 2 (A or B) = 10000 - OHIO = 00010 
Substituting the equation 2 in equation 1: 

3. EXCLUSIVE OR = (A + B) -\j (A + B) - 2 (A or BQ = 01000 - 00010 = 00110 
And simplifying equation 3: 

4. EXCLUSIVE OR = 2 ( A or B) - ( A + B) = OHIO - 01000 = 00110 

5. 3. 12 Convert Instructions 

The three convert instructions can materially reduce the time required for many 
"housekeeping" and table-look -up routines. They can be used for number conversions, 
for preparing print fields, and even for adding numbers in systems other than binary. 

The convert instructions, like variable -length instructions, include a count field as 
well as the operation code, address and tag bit. The convert instructions cause a series 
of references to be made (usually six) and the address specifies the starting location 
of the first storage table. The register (accumulator or MQ) from which the refer- 
ence is controlled is considered to be made up of six 6-bit groups. The first of these 
groups is added to the instruction address to give the location of the first storage refer- 
ence. The word stored at this location must contain, in addition to its conversion in- 
formation, the starting location of the next storage table. The convert-by -replacement 
instructions shift the controlling register six places, clearing the six places on the 



132 



opposite end of the register. Positions(S-5)* of the table word are entered into the six 
cleared positions, and the next group of six bits is in position to add to the starting lo- 
cation of the next table. The process continues until up to six references have been 
made. The controlling register is gradually replaced by six -bit entries from the stor- 
age tables. When the number of references specified by the count has been made, the 
conversion is complete. 

The tag of the instruction has a unique function for the convert instructions. Positions 
(18) and (19) are not used, but a bit in (20) will cause the storage table starting location 
contained in the last reference word to be stored in index register A. 

Convert by Replacement from Accumulator CVR +0114 (Min I, L) Figure 5. 3. 71 

(Max I, L, 6E) 

This instruction treats the contents of the AC(P, 1-35) as six 6-bit representations. 
The instruction replaces a number of these representations, equal to the count of the 
instruction, with the contents of positions (S-5) of a like number of words from storage. 
These words are found by adding AC (30-35) (the first six -bit group) to SR(21-35) 
(initially the instruction address) and directing storage to this modified address. The 
word thus found is brought to the SR; the AC is shifted right six places; SR(S-5) re- 
places AC (P, 1-5). SR(21-35) adds to the next six -bit group in AC (30-35) to locate the 
next word in storage. The process is then repeated. After the required number of 
replacements, the address portion of the last storage word can be stored in index 
register A by including a "tag" bit in position (20) of the instruction. 

The following illustrates the use and operation of CVR: 

Direct Addition of BCD Numbers: 

A + B C 

134589 + 691593 = 826182 



Table required in storage for this example: 



Storage 


Contents 




Storage 


Contents 


Location 


(S-5) 


(21-35) 




Location 


(S-5) 


(21-35) 


1000 


0 


1000 




1010 


0 


1001 


1001 


1 


1000 




1011 


1 


1001 


1002 


2 


1000 




1012 


2 


1001 


1003 


3 


1000 




1013 


3 


1001 


1004 


4 


1000 




1014 


4 


1001 


1005 


5 


1000 




1015 


5 


1001 


1006 


6 


1000 




1016 


6 


1001 


1007 


7 


1000 




1017 


7 


1001 


1008 


8 


1000 




1018 


8 


1001 


1009 


9 


1000 




1019 


9 


1001 



Instructions required for operation: 

CAL A (First BCD word) 

ADD B (Second BCD word) 

CVR 6, 0, 1000 (Convert sum to BCD word) 



* This text section uses (S-S) to represent (S, 1-5). 



133 



I Time 
Pri Op 10 



L Tin 



SR(S-35)-*AD 
(P-35) L0(D3) 

2.12.15.1 







AD(3-17)*AS 
L0 (D3) 




AS(10-17) 
-*SC L2(D1) 


3.06.16.1 




2.11.78.1 






+ . Yes 


* 




SR(18-35)->AD 
(P-17) L9(D3) 




2.12.16.1 




AC(30-35) 
-»»AD(12-17) 
L9(D3) 
2.10.15.1 





AD(3-17)-»-AS 
L9 (D3) 

3.06.16.1 



AS -»-AR 
All(Dl) 
3.06.18.1 



No of Conversions 
in SC 



Develop Desired 
Address in Table 




Bit TR 20^ 



End Op 
2.09.49.1 



AD »-XRA 
2.12.70.1 



6 Bit 
Replace- - 
ment for 
AC 



SR(S-5)-vAC 
(P-5)E11 (Dl) 

2.10.15.1 



FIGURE 5.3-71 . CVR +0114 



1 



E Time 



Shift AC Rt 
E0(D6) 

2.12.33.1 



6 Shifts 



Step SC 
E6(D1) 

2.11.79.1 



1 Step 



SB — *SR 
E7(D1) 



2.12.50.1 



Yes 




esc = o: 



SR(18-35)>AD 
(P-17) E9(D3) 

2.12.16.1 



AD(3-17)*>AS 
E9 (D3) 

3.06.16.1 



No 



AC(30-35)*AD 
(12-17) E9(D3) 
2.10.15.1 

I 



Develop Desired 
Address in 
Table 




Bit TR 20 
Yes 



End Op 
2.09.49.1 



AD(3-17)->- 
XRA Ell(Dl) 

2.12.70.1 



Development of Program 

CAL A(Clear AC, add logical word A). 
Add B 

(Unconverted binary sum) 
CVR 1000, 0, 6 

Series of Steps within CVR 

Table Next 



C(AC) 




Start 


Table 


C(-) Start Loc 






30-35 




Loc 


Refer 


1 


-5 C(-) 21-35 






*© 


+ 


1000 


- 1012 


2 


1001 


— >■ 


2 


17 


-t- 


1001 


- 1018 


8 


1001 


— *■ 


8 


10 




1001 


- 1011 


1 


1001 


— > 


1 


5 


+ 


1001 


- 1006 


6 


1000 




6 


12 




1000 


- 1012 


2 


1001 




2 


7 


■i- 


1001 


- 1008 


8 






8 





Count = zero: if Tag = 1,C1000;XRA 
SLW C (Store converted BCD sum as logical word) 



The execution of CVR requires one L cycle to set the count in the shift counter and 
to calculate the initial table location. The instruction is completed in as many E cycles 
as specified by the count. 

Convert by Replacement from MQ CRQ -0154 (Min I, L) Figure 5.3-72 

(Max I, L, 6E) 

This instruction operates on the MQ, considered to be composed of six 6-bit repre- 
sentations. The instruction replaces a number of these representations equal to the 
count of the instruction, with the contents of positions (S-5) of a like number of words 
from storage. The location of the first of these storage words is found by adding the 
contents of MQ(S-5) to SR(21-35) (intially the instruction address portion). The word stored 
at this modified location is brought to the SR, and the MQ is shifted left six places. 
Positions (S-5) of the stored word are placed in MQ(30-35), and the location of the next 
storage word is computed by again adding MQ(S-5) to SR(21-35) which is now the ad- 
dress portion of the previous storage word. The process continues until the required 
number of replacements have been made. At this time the presence of a tag bit in 
position 20 of the instruction will cause the address portion of the final storage word 
to be stored in index register A. 

The following illustrates the use and operation of CRQ: 

Prepare a BCD number for printing be replacing leading zeros with blanks: 



Convert BCD number 007109 to BL BL 7109 
Instructions required for this operation: 
LDQ A (BCD number in storage) 
CRQ 6,0, 2000 (Convert from MQ) 
STQ B (Store converted number) 



135 



I Time 
Pri Op 14 



L Time 



SR(S-35)-+AD 
(P-35) L0(D3) 

2.12.15.1 



AD(3-17)*AS 
LO (D3) 

3.06.16.1 



AS(10-17)*SC 
L2(D1) 

2.11 .78.1 



No. of Conversions 
in SC 

Yes 



5R(18-35)-»*AD 
(P-17) L9(D3) 

2.12.16.1 




'SC = 0 



No 



MQ(S-5)-*-AD 
(12-17) L9(D3) 

2.10.15.1 



Develop Desired 
Address in Table 



AD(3-17)*AS 
L9 (D3) 

3.06.16.1 



AS -+-AR 
All(Dl) 

3.06.18.1 



End Op 
2.09.49.1 



AD XRA 
Lll (Dl) 
2.12.70.1 



6 Bit 

Replacement 
for MQ 



E Time 



Shift MQ Lt 
E0(D6) 

2.12.42.1 



Step SC 
E6(D1) 

2.11 .79.1 





SB SR 
E7(D1) 

2.12.50.1 












■ 




SR(S-5)*MQ 
(30-35)Ell(Dl) 

2.10.15.1 




SR(18-35)*AD 
(P-17)E9(D3) 

2.12.16.1 



6 Shifts 



1 Step 



Yes 




SC = 0 



No 



MQ(S-5)-*AD 
(12-17)E9(D3) 

2.10.15.1 



AD(3-17)-*AS 
E9 (D3) 

3.06.16.1 



Develop Desired 
Address in Table 



Bit TR 20 




End Op 
2.09.49.1 



AD(3-17) 
XRA Ell(Dl) 

2.12.70.1 



FIGURE 5.: 



,3-72. CRQ-0154 



Storage table required for CRQ (in decimal): 



Storage 
Location 


Contents 




Storage 
Location 


Contents 


( S-5) 


(21-35) 


(S-5) 


(21-35) 


2000 


BL 


2000 




2010 


0 


2010 


2001 


1 


9010 
\j J. kj 




2011 


1 

JL 


901 0 


2002 


2 


2010 




2012 


2 


2010 


2003 


3 


2010 




2013 


3 


2010 


2004 


4 


2010 




2014 


4 


2010 


2005 


5 


2010 




2015 


5 


2010 


2006 


6 


2010 




2016 


6 


2010 


2007 


7 


2010 




2017 


7 


2010 


2008 


8 


2010 




2018 


8 


2010 


2009 


9 


2010 




2019 


9 


2010 



Development of Program 
LDQ A 

CRQ 2000, 0, 6 

Series of Steps within CRQ 



1st 

Char 

Conv 









Table 


Next 


C(MQ)s 


Start 


Table 


C(-)s 


Starting L< 


1-5 


Loc 


Refer 


1-5 


C(-) 21-35 


*0 + 


2000 = 


2000 


BL 


2000 


0 + 


2000 = 


2000 


BL 


2000 


7 + 


2000 = 


2007 


7 


2010 


1 + 


2010 = 


2011 


1 


2010 


0 + 


2010 = 


2010 


0 


2010 


9 + 


2010 = 


2019 


9 


/2010) 




Count = 0; if Tag = 1, (2010^-XRA 

The execution of CRQ is accomplished in one L cycle and a number of E cycles equal 
to the count. 

Convert by Addition from MQ CAQ -0114 (Min I,L) Figure 5. 3-73 

(Max I,L, 6E) 

This instruction treats the MQ as six 6-bit representations, as does CRQ. This 
instruction does not replace any of these representations, but uses them to locate a 
number of storage words equal to the count of the instruction. The storage words are 
located at the address developed by adding MQ(S-5) to SR(21-35) (initially the instruc- 
tion address) and are brought to the SR. The storage words are then added to the 
contents of the accumulator. The MQ is not replaced, but is merely rotated left six 
places to allow the next six -bit representation to be added to the address portion of the 
previous storage word. The process continues until a number of additions (to the AC) 
equal to the count have been made. The operation is then complete. The address por- 
tion of the last storage word used can be stored in index registers for future reference 
by adding a tag bit in position 20 of the instruction. 



137 



I Time 
Pri Op 10 



L Tir 



SR(S-35) — *AD 
(P-35) L0(D3) 

2.12.15.1 



AD(3-17)- 
L0 (D3) 

3.06.16.1 



-AS 



AS(10-17)-*5C 
L2(D1) 

2.11 .78.1 



T 



No. of 
Additions 
in SC 



SR(18-35)^AD 
(P-17) L9(D3) 

2.12.16.1 




MQ (S-5) 
-*AD(12-17) 
L9(D3) 
2.10.15.1 



Rotate MQ Lt 
EO(D6) 

2.12.42.1 



6 Shifts 



Off 



Step SC 
E6(D1) 

2.11 .79.1 




CAQ Tg 



On 



SR(S-35)-*AD 
(P-35) E4(D3) 



2.12^15.1 



AC(Q-35)-*AD 
E4(D3) 

2.12,24,1 



AD(Q-35)-*AC 
E6(D1) 

2.12.31 .1 



Addition 



Yes 



SB — »-SR 
E7(D1) 





AD(Q-35)-*AC 


I6(D1) 




2.12. 


31 .1 



FIGURE 5.3-73. CAQ -0114 



To illustrate the operation and use of CAQ, a program which will convert BCD to 
binary follows. 



Convert BCD Word to Binary 

709542 (BCD) converted to 2,551,646 (Octal) 

Instructions required for this operation: 

LDQ A (BCD word) 

CLM (Clear AC) 

CAQ 6,0, 3000 (Convert to binary) 

ARS 16 10 (Position result in AC) 

SLW B (Store result) 



Storage table required for CAQ: 



Storage 


Contents 


Location 


(S-19) 


(21-35) 


Decimal 


Octal 


Decimal 


3000 


A 
U 


*3i on 


3001 


QAQ OAf) 


*}i oo 


3002 


CAC Kflfl 
DUD , OUU 


*}i oo 


3003 


1 111 74.0 
JL , ill , / rtU 


on 


3004 




*3i oo 


3005 


1 790 AACi 


*3i oo 


3006 


9 OOQ ^AA 


*31 OO 


3007 


2,527,140 


3100 


3008 


3,032,400 


3100 


3009 


3,335,640 


3100 


3100 


0 


3200 


3101 


23,420 


3200 


3102 


47,040 


3200 


3103 


72,460 


3200 


3104 


116,100 


3200 


3105 


141,520 


3200 


3106 


165,140 


3200 


3107 


210,560 


3200 


3108 


234,200 


3200 


3109 


257,620 


3200 


3200 


0 


3300 


3201 


1,750 


3300 


3202 


3,720 


3300 


3203 


5,670 


3300 


3204 


7,640 


3300 


3205 


11,610 


3300 


3206 


13,560 


3300 


3207 


15,530 


3300 


3208 


17,500 


3300 


3209 


21,450 


3300 



Storage 


Contents 


Location 


(S-19) 


(21-35) 


Decimal 


Octal 


Decimal 


•^OO 
OOVV 


0 


O/j AA 

3400 


qqni 


144 


O A A A 

3400 


Q *3 A9 
ooUZ 


310 


3400 


qqnQ 
OOUo 


A C A 

454 


3400 


'zmA 

OOV^t 


620 


3400 


ooVO 


764 


3400 


Q Q AC 
OOVO 


1 , 130 


O A A A 

34U0 


OO V l 


1,274 


3400 


3308 


1,440 


3400 


3309 


1,604 


3400 


3400 


0 


3500 


3401 


12 


3500 


3402 


24 


3500 


3403 


36 


3500 


3404 


50 


3500 


3405 


62 


3500 


3406 


74 


3500 


3407 


106 


3500 


3408 


120 


3500 


3409 


132 


3500 


3500 


0 




3501 


1 




3502 


2 




3503 


3 




3504 


4 




3505 


5 




3506 


6 




3507 


7 




3508 


10 




3509 


11 





139 



Development of Program 



Binary Equivalent 



LDQ BCD WORD 
CLM 










CONTENTS OF ACCUMULATOR 


P, 1-19 


21-35 


XX 


XX 


00 


00 


CAQ 3000, 


0, 6 












RQL 6 






Series of Steps within CAQ 




















Next 








C(MQ) 




Start 


Table 


Table 


Start Loc 






S, 1-5 




Loc 


Refer 


C(-)S, 1-19 


C(-) 21 


-35) 




Count 


7 




3000 = 


3007 


2,527,140 


3100 




2,527,140 3100 


5 


0 


-t- 


3100 = 


3100 


0 


3200 


+ 


0 3200 


4 
















2,527,140 6300 




9 




3200 = 


3209 


21,450 


3300 


-t- 


21,450 3300 


3 
















2,550,610 9600 




5 




3300 = 


3305 


764 


3400 




764 3400 


2 
















2,551,574 13000 




4 


+ 


3400 = 


3404 


50 


3500 




50 3500 


1 
















2,551,644 16500 




2 


-i- 


3500 = 


3502 


2 






2 


0 
















2,551,646 16500 




ARS 16 (Binary Equivalent) 








^2,551,646 

















SLW 



BCD Word 




5. 3. 13 Floating Point Trap (Figure 5. 3-74) 



To simplify the programming associated with floating-point overflow or underflow, a 
unique system of spill indication is used. When an underflow or overflow occurs in 
either the accumulator or MQ during a floating-point operation, an instruction trap is 
taken to location OOlOg, after ending operation on the executer instruction. In addition , 
the location of the floating-point instruction plus one is stored in the address portion of 
location 0000, and a spill identification code is stored in the decrement portion of loca- 
tion 0000. 

The 7090 floating-point trap mode trigger (Systems 2. 10.71. 1) is reset on, putting the 
CPU in a floating-point trap mode status normally. To leave this condition, a LFTM 
(leave floating-trap mode) instruction must be executed. The mode of operation may 
then be re-entered by resetting the CPU or executing an EFTM (enter floating trap mode) 
instruction. 



The spill identification code is produced as follows: 



1. Position 14 is set to one if overflow or underflow occurs during a floating- 
point divide operation. 

2. Position 15 is set to one if overflow occurs in either the accumulator or MQ. 

3. Position 16 is set to one if overflow or underflow occurs in the accumulator. 

4. Position 17 is set to one if overflow or underflow occurs in the MQ. 



This results in the spill identification codes for the various conditions as follows: 



Floating-Point 



Positions 



Octal 



Operation 


Accumulator 


MQ 


14 


15 


16 


17 


Co 


Add, Subtract 




Underflow 


0 


0 


0 


1 


01 


Multiply, 


Underflow 


Underflow 


0 


0 


1 


1 


03 


Round 


Overflow 




0 


1 


1 


0 


06 




Overflow 


Overflow 


0 


1 


1 


1 


07 


Divide 




Underflow 


1 


0 


0 


1 


11 




Underflow 




1 


0 


1 


0 


12 




Underflow 


Underflow 


1 


0 


1 


1 


13 






Overflow 


1 


1 


0 


1 


15 



The code stored in the decrement may be loaded into an index register and an indexed 
transfer instruction may be used to lead to the proper corrective routine. 

Underflow and overflow of the floating-point characteristic are detected by examining 
positions P and Q of the adders and the accumulator. Overflow is identified by a bit in 
(P) only. Underflow is identified by bits in (P) and (Q). MQ overflow or underflow must 
be recognized as the MQ characteristic is being computed in the adders. ACC overflow 
to underflow may be recognized at any time after the final characteristic has been 
assigned. 



141 



ACC Overflow or 
Underflow 



2.03.36.1 





MQ Overflow or 
Underflow 



2.10.51 .1 



n 



Prevent 
SB— M>R 
17 (D2) 
2.11.40.1 



Prevent 

Decoding 

Instruction 



Prevent 
PC Adv 
19 (Dl) 
2.11.51.1 



Turn On FP 
Trap Tgr 
14 (D3) 
2.10.51 .1 

3= 



"I" Cycle Following 
Floating Point Operation 



Force Str 
17 (Dl) 

2.11 .40.1 



Prevent 
Channel Trap 
16 (Dl) 
2.10.56.1 



Prevent 
Interrupt 
15 (Dl) 
2.10.60.1 



1 


f 






Prevent 




AS— ^AR 


AD(3-17) *■ 




111 (Dl) 


AS 19 (D3) 








2.10.09.1 




3.06. 18. 1 



Zero in AR 



' *M 


' 




" E" Time 






Prevent 




1-*AS 14 


1 — »-AS 16 




E10 (D2) 


E10 (D2) 






3.06.14.1 




3.06.14.1 



AS — »► AR 
Ell (Dl) 

3.06.18.1 



Prevent 
PC-^AS 
E9 (D3) 
3.05.09.1 



2.10.50.1 



Condition Occurred Overflow in ACC 
During FP Div or MQ 



2. 10. 50 J |v 

■flow—) 



ACC Over 
or Underflow 



Trap to Ten 



I Time 
Next Instruction 



1 -*-SB 17 
E Time 



2.10.50.1 



MQ Overflow 
or Underflow 



3 



AR-^PC 
13 (Dl) 

3.06.05.1 



Reset MQ 
DV Tgr 
11 (Dl) 
2.10.51 .1 



Reset FP 
Divide Trigger 
II (Dl) 
2.10.52.1 



Reset FP 
OV Trigger 

11 (Dl) 
2.10.52.1 



Reset FP 
Trap Trigger 

II (Dl) 
2.10.51.1 



Ten in PC 



FIGURE 5.3-74. FLOATING POINT TRAP MODE 



142 



The recognition circuits are shown on Systems 2. 10. 50. 1. To set position 14 of the 
decrement, the floating-point divide occurred trigger is used. To set position 15, the 
floating-point overflow trigger is turned on by a bit in (P) only. To set position 16, a 
bit in ACC (P) is all that is required. To set position 17, the MQ overflow trigger is 
turned on by an adder (P) output while the MQ characteristic is being computed. 

The controls for floating-point trap are shown on Systems 2.10. 51. 1. An overflow 
or underflow causes the floatingpoint trap trigger to be turned on. This trigger initiates 
a pseudo STR instruction by blocking the instruction following the floating-point instruc- 
tion during which the condition occurred and setting IR sign (-) and a one in IR (9). 
Address 0000 is set into the address register, store decrement and store address con- 
trols are activated, and an E cycle is initiated. The program counter and the four spill 
code lines are routed to the storage bus and stored in location 0000. The address regis- 
ter is then set to 0010g to locate the next instruction to be executed. 



143 



6.0.00 IBM 7151 CONSOLE CONTROL UNIT 



The 7151 Console Control Unit is a separate unit that may be placed at any convenient 
location within certain cable length restrictions. It provides manual and semiautomatic 
control over the system. The console consists of three panels: an operator's panel, a 
customer engineer's test panel, and a marginal check panel. With proper use, the con- 
sole can be one of the customer engineer's most powerful tools. The time spent learning 
how to use it effectively is returned many times when diagnosing system errors. 

This section introduces the keys, lamps, switches, and test facilities, their function, 
and any associated logic. 

During the progress of a program, the operator may want some amount of control. 
For example, at a given point in a calculation, the computer is given the instruction to 
halt. The operator then can make a visual check of the information developed thus far 
in the program. At this point, one of several alternate manual steps may be performed, 
depending on the data observed. For this operation, the automatic -manual switch is set 
to MANUAL. With the machine in this state, the operator may enter and execute an 
instruction, interrogate any locations in storage for a visual check of the information 
stored, or load data from the operator's panel keys. After the desired manipulations 
have been made, the machine is returned to automatic status; the start key is depressed 
and the program continues. 

The start and stop of the machine are under control of the master stop trigger. 
This trigger in turn controls "B cycle interrupt, " which gates the I, E, and L cycles. 

The keys, switches, and lamps on the console provide a means to: 

1. Start or stop the machine 

2. Step through a program at reduced speed 

3. Check the status of the CPU 

4. Display or revise the contents of storage 

5. Alter the program 

In addition, the customer engineer has facilities for several testing features which 
include: 

1. Auxiliary start and reset key 

2. I-O interlocks 

3. Continuous execution of an instruction 

4. Power jacks for test equipment 

5. B cycle control 

The console (Figure 6.0-1) is divided into three sections; an operator's panel, a 
customer engineer's test panel, and a bias panel. Figure 6. 0-2 designates system 
page locations for the keys and indicators located on the console. 



144 




FIGURE 6.0-1. IBM 7151 CONSOLE 



Index 
Register 
A. B.C. 

00.20.70.0 



Prog . Stop 
l-O Chk 
Rdy/Auto 



00.20.41 .0 



Trap & Chk. Ind. 
00.20.14.0-00.20.90.0 



Program Register 
00.30.40 



Program Ctr. 
00.30.50.0 



Storage Register 
Accumulator Register 
MQ 



00.20.11 .0 
00.20.30.0 
00.20.40.0 



Clear 
00.40.10.0 



Manual Control 

Keys 
00.40.10.0 



Entry Keys 
00.20.10.0 



0 



Emerg. 
Off 



Channel 
Select 
& Trap. Ind. 



00. 60. xx. 0 



Sense 
Switches 
00.20.91 .0 



9.02.01 . I 



Customer 
Engineer's 
Panel 



See Fig. 2.3-2 
for Breakdown 



Marginal Check Panel 



Voltmeters 



9.05.12.1 



Marginal Check 
Selector Switches 
9.05.11.1 - 9.05.31.1 



FIGURE 6.0-2. BLOCK DIAGRAM OF CONSOLE 



145 



6. 1. 00 OPERATOR'S PANEL 



The operator's panel provides for visual checking of the information in the computer 
and for manual control of the computer's functions. It is also a station from which 
power may be applied to or removed from the system. 

6.1.01 Indicators 

All indicators on the console are of the incandescent type. When used to indicate the 
condition of a register, a lamp being on signifies a 1, while a lamp being off signifies 
a 0. 

Internal Registers 

The contents of the internal registers (accumulator, multiplexor -quotient, storage 
register, instruction counter, instruction register, and index registers A, B, and C) 
are displayed directly on the panel. 

Trap 

This lamp is on whenever the machine is in the transfer trapping mode. 
Simulate 

The simulate lamp is on when the 7090 is operating in any of the following modes 
associated with the 704, 709, or 7090 compatibility program: 

1. I-O select and sense trap mode 

2. Copy and locate drum address trap mode 

3. Storage nullification mode 

Accumulator Overflow 

The accumulator overflow lamp is on any time during a fixed point operation (add, 
subtract, and so on) or shifting operation that a carry out of position 1 of the accumu- 
lator occurs. It is also turned on by a bit in position P during the execution of a float- 
ing point instruction while in compatibility mode. It may be turned off by the TNO or 
TOV instruction. 

Quotient Overflow 

This lamp is on whenever the computer is using the compatibility program and an 
MQ overflow occurs. 



Read-Write Select 

The read-write (R-W) select lamp is on whenever the channel-in-use trigger is on 
in any data channel. 



146 



Divide Check 

The divide check lamp is turned on in fixed point division if the dividend accumu- 
lator (AC) is greater than or equal to the divisor (storage register). In floating- 
point divide the lamp is on if the magnitude of the fraction of the dividend is greater 
than or equal to twice the magnitude of the fraction of the divisor. The indicator may 
be tested by the DCT instruction.. 

Channel Select (A-H) 

The channel select (A-H) lamps, one for each channel, are on according to the 
data channel that is in operation. They are off when the channel is not in operation. 

Command Word Trap (Channels A-H) 

These lamps are turned on according to the corresponding channel that is enabled 
to trap on command word or end of file. The lamp for a particular channel is turned 
off when the channel is disabled. 

Tape Check Trap (Channels A-H) 

These lamps are on according to the corresponding channel that is enabled to trap 
on a tape check. The lamp for a particular channel is off when the channel is disabled. 

Channel Tape Check 

These lamps, one for each channel, are on if any error is detected while writing 
or reading. The lights may be turned off by the execution of a Transfer on Redundancy 
Check instruction. 

Trap Control 

This lamp is on when the channel is not executing a channel trap. It is off when 
any channel enters a trap condition. While the light is off, no channel traps may be 
executed. Channel traps may be executed only when the light is on at the same 
time as any of the enabled lamps. 

Program Stop (Red) 

The program stop lamp is turned on whenever the computer executes a halt instruc- 
tion and no data channels are in operation (DVH or VDH excepted). 

I-O Check (White) 

The I-O check lamp may be turned on by any of the following conditions: 

1. If a RCH or LCH is decoded and the specified data channel has 
not been selected. 

2. If, when writing, a data channel data register has not been 
loaded with a word from storage by the time its contents are 
to be sent to the output unit. 



147 



3. If, when reading, a data channel data register has not transmitted its 
contents to storage by the time new information is to be loaded into it 
from an output unit. 
The I-O check lamp may be turned off by the execution of an IOT. 

Read Light (White) 

The ready lamp comes on after power comes up and remains on except when the ma- 
chine is in automatic status, the continuous enter instruction switch is on, the I-O inter- 
lock switch is in manual, or if any B-time control switch is on. 

Automatic (Yellow) 

The automatic lamp is on whenever the computer is executing instructions in the 
automatic mode or whenever a data channel is in operation. 

Console Power -On (Red) 

The console power-on lamp is on whenever power is applied to the console. 
Central Components Power Check (Yellow) 

The central components power check comes on whenever a fuse or circuit breaker 
opens in CPU frame 1 or 2, multiplexor, or core storage. It also lights when core 
storage has improper oil temperature or low oil pressure. 

I-O Power Check (Yellow) 

The I-O power check lamp is turned on whenever a fuse, an open thermal, or air- 
flow failure is sensed in a data channel. 

Power (Red) 

The power indicator is turned on whenever DC power is up in core storage. 
Marginal Check +6 (Yellow) 

This indicator is on whenever the +6 supply marginal check variable autotransformer 
is not in the home position. 

Marginal Check -12 (Yellow) 

This indicator is on whenever the -12 supply marginal check variable autotransformer 
is not in the home position. 



148 



6. 1. 02 Manual Controls 

Figure 6. 1-1 shows the keys and switches on the operator's panel that provide for 
starting and stopping the machine and initiating computer functions. All keys are of the 
spring-returned variety with the exception of the auto-manual key, entry keys, sense 
switches , and emergency-off key. 

Power-On 

With the system in normal-off status , pressing the power-on key will commence the 
power-on sequence. Ready status (power-on) will be reached in about 20 seconds. As 
power comes on, a clear operation is performed, resetting all registers and triggers, 
and setting memory to all zeros. 

Normal-Off 

The normal-off key will initiate the following: 

1. Immediate removal of 60-cycle power from the MG set, MG blower, and all 
frame blowers except memory. 

2. Immediate removal of 400-cycle power from the 30-60 volt memory power supply. 

3. After 5 seconds, removal of 400-cycle power from the standard memory supply. 

4. After 3 minutes, removal of power from the memory blowers. 

The dropping of the 60-cycle power removes the input to the MG, but the MG still 
rotates at about full speed for longer than 5 seconds , allowing the memory power to 
sequence down. 

Emergency-Off 

When the emergency-off switch is pulled, all power is immediately removed from 
the 7090 system, except the voltage to HR 24 and HR 30 points in the power control unit. 
The emergency-off switch is to be used only in emergencies, because of possible dam- 
age to circuits. 

Resets 

The reset circuits control the resetting of various components in the system. 
There are three types of resets which may be initiated from the panel. 

An interlock reset is initiated by the load keys, clear key, and 
power -on key. It causes the resetting of all registers (except 
sense indicator) , panel light (except power on and ready) , all 
channels that are in operation and their associated registers. 

An operator's reset is initiated by the reset key. It performs all the 
functions of an interlock reset plus a bias reset for CPU triggers. 

A power-on reset occurs when power is applied to the system. This 
reset accomplishes an interlock reset, an operator's reset, plus the 
resetting of the clock and setting core storage to all zeros. The clear 
key also initiates a power-on reset if the machine is in automatic 
status . 

Automatic -Manual Key 

The auto-manual switch controls the rest of the switches on the console. If a pro- 
gram is running in automatic status, and the switch is put in the manual position, the 
program will stop after it completes the operation it is performing. If an I-O program 
is running, I-O will complete the operation before stopping. The auto-manual switch 
will not affect the program stop status. 



149 



/ Any Man 
1 Ctrl Key 







1 usee 


SS 




04.20.04.1 






30 Msec 


SS 




04.20.04.1 






350 usee 


SS 




04.20.04.1 


1 




200* 




Pulse 




04.20.04.1 






Turn On 


Man Ctrl Tgr 


04.20.05.1 



Auto. 



Man 




R 


S 


S 










E 


P 


P 


Disp 


Disp 


Load 


Load 


S 


A 


A 




Eff 






E 


R 


R 


Ind 


Adr 


Tape 


Cards 


T 


E 


E 














Mult 


Sing 


Enter 


Enter 


Disp 


START 
















Step 


Step 


MQ 


Inst 


Stg 



S 




ENTRY KEYS 


35 




FIGURE 6.1-1 


OPERATOR'S PANEL 





Key 
R 



Man Ctrl Tgr 
On Ungated 

04.20.05.1 



Allow Keys to be 
Active in Auto 
Clear, Start, Ld 
Cards, Ld Tape 
04.20.06.1 
04.20.07.1 



Man Ctrl Tgr 
On Ungated 

04.20.05.1 



Turn on Op 
Panel Ctrl Tgr 

04.20.16.1 



Off 
19 



After Execution 
of Operation 
Called for, Follow 
ng Occurs 



On at 14 
with Op Pnl 
Ctrl Tgr 
Off 



Turn On 
Man Stop Tgr 

04.20.18.1 



Turn On 
MST Tgr 

04.20.16.1 



17 



Man Ctrl Tgr 
On Gated 

04.20.05.1 






Turn On Tgrs 
For Other Man 
Ctrl Key 
Operations 








Turn Off Man 
Ctrl Tgr 

04.20.05.1 



Gated by 
Manual 
and AO 



Release 
Any Key 



FIGURE 6.1-2. MANUAL CONTROL KEY 



150 



Entry Keys 



There are 36 entry keys on the operator's panel: S, 1-35. Depressing a key sets a 
1 in that position; leaving a key normal sets a 0 in that position. Information set in the 
entry keys may be entered into storage, executed, or used for a storage inquiry address. 
The entry keys may all be reset to 0 by depressing the reset key to the right of position 
35. 

6. 1. 03 Manual Control Keys 

When any manual control key is pressed, a series of single-shots and triggers are 
set. Separating the key from the usable signal prevents false indications from noise 
generated by the key (Figure 6. 1-2). Three single-shots are fired in sequence: a 
1-usec, a 20-ms and a 350-usec. The 350-usec single-shot is taken through a delay 
network to develop a 200-ns pulse that turns on the manual control trigger. By this 
time , the switch has settled down and the trigger to perform the desired operation turns 
on, resetting the manual control trigger. 

Start Key (Figure 6.1-3) 

If the CPU is in automatic and ready status, pressing the start key initiates machine 
operation by turning off the master stop trigger and the program stop trigger. The 
master stop trigger off conditions "not B cycle interrupt," allowing the computer to 
proceed. If the system is in manual status, pressing the start key turns off the program 
stop trigger. 

Clear Key (Figure 6.1-4) 

The clear key is only operative if the computer is in automatic status. Pressing the 
clear key: 

1. Fires a 1-usec single-shot to reset the clock and all channel registers of channels 
that are not in manual status. 

2. Resets CPU interlocks and registers. 

3. Conditions circuits which allow zeros to be written into all storage locations. 

The program counter controls the stepping through memory, with position 2 of the 
PC indicating when all addresses have been zeroed. The turn-on of PC2 trigger will 
turn on the master stop trigger at E10. 

Display Storage (Figure 6. 1-5) 

Pressing the display storage key causes the address portion of the operator's panel 
keys to be sensed, to determine the address in storage to be displayed. All 36-bit posi- 
tions of the address will be displayed in the storage register. This is accomplished by: 
(1) turning off the master stop trigger, (2) bringing the operator's panel keys to the 
storage register in I time, and (3) suppressing "storage bus to storage register. " The 
address portion of the SR is routed through the adders and address switches, to the 
address register. During E time, the SB is gated to the SR, which contains the 36 bits 
of the desired address. If a tag or indirect addressing is specified in the operator's 
keys, the contents of the effective address or the I- A address will be displayed. 

Display Indicators 

The display indicators key gates the true value of the sense indicators to the stor- 
age for display (Figure 6. 1-6). 



151 




Bring Up 


"Not B 


Cycle 


Interrupt" 


8.00. 


13.1 






Not B Cycle 


Interrupt Gates 


1, E or 


L Time 




Fire Man 
Ctrl SS 
4.20.04.1 



Turn On 
Man Ctrl Tgr 



4.?0 



05.] 



Turn On 
Clear Stg Tgr 

4.20.06.1 



Turn Off Man 
Ctrl Tgr 

4.20.05.1 



lus 


SS 


4.20 


12.1 






Clock Reset 


4.20 


12.1 




1 

> 


Intlk and 


Reg Reset 


4.20 


.12.1 



Bring Up Man 
Go To E 

4.20.06.1 



Bring Up 


Clear 


Ctrl 


4.20.06.1 






Store 


Ctrl 


2.09. 


00.1 






Bring Up 


Clear Stg 


4.20.06.1 






Turn Off 


MST Tgr 


4.20 


.11.1 



/ Take 1 
( I Cycle 
yThen E's 



Write Zero 



PC to AS 
3.05.09.1 



AS to AR 


3.06 


.18.1 






PC Advance 


on Clear 


4.20 


.06.1 








E10 



E10 



FIGURE 6.1-3. START 



FIGURE 6.1-4. CLEAR STORAGE 



152 



Machine 
in Manual 




Fire Man 
Ctrl SS 



4.20.04.1 



Turn on Man 
Ctrl Tgr 

4.20.05.1 



Turn On OP 
Panel Ctrl Tgr 
4.20.16.1 



Turn on Disp 
Stg Tgr 

4.20.08.1 



Turn Off Man 
Ctrl Tgr 

4.20.05.1 



Bring Op 
Disp Stg Ctrl 

4.20.08.1 



Suppress Pri 
Op 00 

3.01.00.1 



Not L Time 
Call 

8.00.16.1 



(Block Halt Control) 
Note: Black AR*PC 
During L Cycle of HTR 



End Op 
Control 

4.20.12.1 



End Op in 
E Time 

8.00.00.1 



f 

Turns On 
Go to E Tgr at 
I10(D3) 



t 

Turn on End 
Op Tgr at E10 



Turn Off 
MST Tgr 

4.20.11.1 



Mst I Tgr 
8.00.18.1 



Reset PR 
10 (D3) 
2.11 .40.1 



Suppress SB 
to SR, TR, PR, 



IC 



4.20.14.1 



Suppress PC 
Adv 

4.20.14.1 



Inhibit Op 
Keep to PR 
2.11.40.1 



Op Keys to 
SR 

4.20.14.1 



A6 



All 



Route Address of 
SR Through Adders, 
Addr SW, to AR 



19 



Turn Off Op 
Panel Ctrl Tgr 

4.20.16.1 



Go to E Trg 
On By Not L 
Time Call 
8.00.12.1 



I9(D3) 



Mst E Tgr 
8.00.19.1 



Gate SB to 
SR 

2.12.50.1 



Turn On End 
Op Tgr 

8.00.09.1 



Gate PC-*- AS 
AS-*AR 



E7 



E10 



Ell 



Go to I Time 
8.00.12.1 



Turn On Man 
Stop Tgr 

4.20.18.1 



On 14 
Off Al 



Turn On 
MST Tgr 

4.20.11.1 



Reset Disp 
Stg Tgr 
4.20.09.1 



A8 



FIGURE 6.1-5. DISPLAY STORAGE 




4.20.04. 1 



Turn On Man 
Ctrl Tgr 

4.20.05.1 



On at AO 



Turn On Disp 
Ind Tgr 



4.20.06.1 



Off at A10 



Turn Off 
Man Ctrl Tgr 

4.20.05.1 



SI to SR 



2.12.13.1 



A2 




Turn On Man 
Ctrl Tgr 

4.20.05.1 



Turn on Disp 
Eff Addr Tgr 

4.20.09.1 



AO 



Turn Off 
Man Ctrl Tgr 

4.20.05.1 



Bring Up Disp 
Eff Addr 

4.20.20.1 



Minus On Disp 
Eff Addr Ctrl 

4.20.20.1 



Calculate Eff 
Addr 

2.10.65.1 



SR 18-35 to 
Adders P-17 
AO (D8) 
2.12.16.1 



XR to Adders 
AO (D8) 
2.12.19.1 



Adders 3-17 
to AS 
AO (D8) 
3.06.16.1 



Carry to 
Adder 17 
AO (D8) 
2.12.19.1 



AS to SR 

A6(D1) 

3.06.12.1 



Turn Off Disp 
Eff Adr Tgr 
4.20.09.1 



Eff Addr 
in SR 21-35 



Hold Tag 
Reg Reset 
2.08.01.1 



Hold AD3 Carry 
Tgr Reset 

2.12.76.1 



Gate XR 
Specified 
to AD 
2.12.26.1 



NOTE: Specified 
by Bit in SR Positions 
18,19, or 20 



A8 



FIGURE 6.1-6. DISPLAY INDICATORS 



FIGURE 6.1-7. DISPLAY EFFECTIVE ADDRESS 



154 



Display Effective Address (Figure 6. 1-7) 

The display effective address key initiates the calculation of the effective address of 
the instruction in the storage register. The actual address from the storage register 
is combined with the two's complement of the specified index register to produce the 
effective address. The calculated address is then placed in the address portion of the 
storage register. Positions 1 through 20 of the storage register are set to zero. The 
effective address may be calculated only once because the positions 18, 19, and 20 of 
the storage register have been set to zero, an indication of no index register. 

Single Step (Figure 6.1-8) 

Pressing the single-step key results in executing the instruction whose address is in 
the instruction counter prior to key depression. The instruction counter will be advanced, 
or altered, under control of the instruction executed, once for each time the key is 
pressed. If an I-O operation is executed, the machine will continue to execute instruc- 
tions at high speed until the end of the I-O operation. If the continuous enter instruction 
switch is on, the single-step key is pressed, and the 7090 is in manual status, the in- 
struction set in the OP keys will be executed once. The single-step key is effective 
only if the system is in manual status , and not in program stop status . 

Multiple Step (Figure 6. 1-9) 

This key is effective only in manual status with the program stop trigger on. The 
multiple-step key causes the repetition of single-step operations. The rate of operation 
is under control of a toggle switch located on the customer engineer test panel. The 
operator has the choice of low speed with a delay of 104 milliseconds between each in- 
struction, or high speed with a delay of 24 milliseconds between each instruction. The 
program will continue to run as long as the multiple step key is pressed, or until a pro- 
gram halt is decoded. 

Enter MQ Key 

The enter MQ key provides a means for loading the MQ register from the operator's 
entry keys. The information may then be loaded into storage by placing the instruction 
STQ along with the desired address in the entry keys and depressing the enter instruc- 
tion key. The enter MQ key is effective only when in manual status. See Figure 6. 1-10. 

Enter Instruction (Figure 6. 1-11) 

With the machine in manual status , the enter instruction key executes completely and 
correctly any legitimate instruction entered in the operator's panel entry keys. The 
contents of the instruction counter remain unchanged when an instruction is executed 
(except for a transfer or a skip type of instruction). The key is effective only in manual 
status . 

Load Cards (Figure 6. 1-12) 

The load cards key causes a reset of the instruction counter, address register, pro- 
gram stop trigger, simulate, and all channels not in manual status. Pressing the load 
cards key then causes a select of the card reader on channel A, reads the first three 
words, and proceeds to storage locations zero for the next command word. This is 
accomplished by bringing up "load ctrl," which fires a 1-usec single-shot. The auto load 
trigger goes on in the CPU, selecting the card reader on channel A. The word counter 
is set to three, and indicator S is turned on in channel. Three words from the first 



155 



/ Machine in 
I Manual 




Turn On 
Man Ctrl Tgr 

4.20.05.1 



Turn On Op 
Panel Ctrl Tgr 
4.20.16.1 



Turn On 
SS Tgr 

4.20.09.1 

; 



Turn Off 
Man Ctrl Tgr 
4.20 .05.1 
1 



Turn Off 
MST Tgr 
4 . 20 . 1 1 



AO 



A6 



Bring Up Not 
B Cycle 
Interrupt 
8.00.13.1 



T 



Gate Master 
I Time 



8.00.18.1 



Reset PR 
10 (D3) 
2.11.40.1 



T 



Turn Off Op 
Panel Ctrl Tgr 
4.20.16.1 



Execute Inst 



End Operation 
I 



Turn On Man 
Stop Trigger 
4.20.18.1 



Turn On 
MST Tgr 
4.20. 11 . 



All 



On at I 4 
Off at Al 




Fire Man 
Ctrl SS 



4.20.04.1 



Turn On Man 
Ctrl Tgr 
4.20.05.1 



Turn On Enter 
MQ Tgr 

4. 20. 08 J 



AO 



Turn Off 
Manual Ctrl 
Tgr 

4.20.05.1 



Op Keys to SR 
4.20.14.1 



Bring Up 
SR to MQ 
4.20.14.1 



Gate Op Keys 


to SR 




2.12 


.09.1 



Gate SR into 
MQ 

2.12.40.1 



Turn Off Enter 
MQ Tgr 
4.20.08.1 



A2 



A5 



All 



FIGURE 6.1-8. SINGLE STEP KEY 



FIGURE 6.1-10. ENTER MQ 



On at AO 



Off with 
Key Release 




Turn Off 
MST Tgr 

4 . 20 . 1 1 . 1 



Bring Up Not 
B Cycle Int 

8.00.13.1 



Gate Master 
I Time 

8.00.18.1 



Reset PR 
10 (D3) 
2.11 .40.1 



z 



Turn Off Op 
Panel Ctrl Tgr 
4.20.16.1 



T 



Execute 
Inst 



End Operation 



A6 



All 



Yes 



High 



Mult Step 
High- Low 
Speed "Sw 



Fire 24 ms 


SS 




4.20. 


17.1 



Turn On Man 
Stop Trigger 

4.20.18.1 



/Mult Step 

Key 
\ Depressed 



Low 



On at 1 4 



Off at A 1 



Fire 104ms SS 
4.20.17.1 



17 



Turn On 
MST Tgr 
4.20.11 



Turn On B 
Cycle Int Tgr 
8.00.13.1 



Turn on Op 
Panel Ctrl Tgr 
4.20.16.1 



All 



NOTE: Prevents Turning 
On Manual Stop Tgr 
During 1st I Cycle's 



FIGURE 6.1-9. MULTIPLE STEP KEY 



Machine in 
Manual 



Ent 
Inst 
Key 



Fire Manual 
Ctrl SS 



4.20.04.1 



Turn On Man 
Ctrl Tgr 

4.20.05.1 



Turn On Op 
Panel Ctrl Tgr 
4.20.16.1 



Turn On Ent 
Inst Tgr 

4.20.08.1 



AO 



Op Keys 
to SR,PR, 
and Tag R 
4.20.14.1 



Gate Op 
Keys into 
SR,PR,TR 
2.12.09.1 



17 



Machine in 
Ready and 
Auto 




Block SB ♦►PR, 
SR, TR 17 
4.20. 14.1 






Suppress 
PC Advance 


4.20 


.14.1 






Turn On Op 
Panel Ctrl Tgr 
4.20.16.1 


> 





Fire 


Manual 


Ctrl 


SS 


4. 


20.04.1 



Turn On Man 
Ctrl Tgr 
4.20.05.1 



On at A3 V 



19 



Turn On Load 
Card Tgr 

4.20.07.1 



Off at I 4 



Turn Off Man 
Ctrl Tgr 

4.20.05.1 



Turn Off Man 
Ctrl Tgr 




^Execute Inst 


4.20.05.1 


























Turn Off 
MST Tgr 


A 
6 




End 

Operation 


4.20.11 .1 










1 






On at 1 4 i 




Bring Up Not 
B Cycle 
Interrupt 

8.00.13.1 


All 




Turn On 
Man Stop Tgr 

4.20.18.1 


1 




Off at Al 




Gate Master 
1 Time 


All 




Turn On 
MST Tgr 


8.00 


.18.1 






4.20. 


11.1 



Bring Up Load 
Ctrl 
4.20.07.1 



Fire lus SS 
4.20.15.1 



On at A2 v 



Turn On Auto 
Load Tgr 

4.20.15.1 



Off at B4 



Go to 
Channel 



Set Card Readei 
Select 
80.50.02.1 



" On Al 



Turn on Load 
Sync Tgr 
60.30.06.1 

I Off A9 



Set WC 


= 3 


60.30.01 .1 






Set "S" 




Op Reg 




60.20.01 .1 




Fire Man 
Ctrl SS 

4.20.04.1 



Channel h< 
IOCP 3,0000 



Read in 
3 Words 



Turn On Man 
Ctrl Tgr 
4.20.05.1 



On at A3 



Turn On Load 
Tape Tgr 

4.20.07.1 



Off at 1 4 



WC = 0 Bring 
Up Ctrl Wd Gt 



Ctrl Wd Gt 
Brings Up 
BCW Req 



A2 



A3 



Turn Off Man 
Ctrl Tgr 
4.20.05.1 



Bring Up 
Load Ctrl 
4.20.07.1 



BCW Bring ^ 
Next Comd 







Bring U 
Load B< 
4.20.1 


P 

:w 

5.1 






One to 
AS 17 
3.06.14.1 






AS to AR 
4.20.15.1 






Turn Off 
MST Tgr 

4.20.11 .1 



Fire lus SS 
4.20.12.1 



On at Al v 



Turn On Auto 
Load Tgr 
4.20.15.1 



Off at B4 



Go To 
Channel 



1 




Set Tap 




Rds Tgr 




60.50.02.2 



On Al 



A6 



Turn On Load 
Sync Tgr 

60.30.06.1 



I Off A9 



Set Tape 
Unit Sel 1 
60.50.04.1 



Set WC 3 
60.30.01 .1 



Set "S" Op 
Register 

60.20.01.1 



Channel has 
IOCP 3,0000 



Read in 
3 Words 







WC = 0 Bring 
Up Ctrl Wd Gt 

60.20.03.1 






Ctrl Wd Gate 
Brings BCW Req 
60.80.03.1 


1 


1 



A2 



A3 




Bring Up 
Load BCW 
4.20. 15. 1 



Bring Up 1 
to AS 17 

3.06.14.1 



AS to AR 
4.20.15.1 



Turn Off 
MST Tgr 

4.20.11 .1 



A6 



FIGURE 6.1-11 . ENTER INSTRUCTION 



FIGURE 6.1-12. LOAD CARDS 



FIGURE 6.1-13. LOAD TAPE 



157 



card enter storage location zero, one, and two. The word entered in address zero 
should be a control word. When the word counter goes to zero, the channel asks for 
another control word from location zero. The CPU gets its next instruction from loca- 
tion one. 

Load Tape Key (Figure 6. 1-13) 

The load tape key works the same as the load cards key, causing a reset to the CPU 
and all channels not in manual status. The load tape key also causes a read select of 
tape unit 1 on channel A, IOCP word count of 3. The next command for the channel will 
come from location zero, and the next instruction for CPU will come from location 
00001. 

Sense Control 

There are two types of sense controls on the operator's panel: sense lights and 
sense switches. The conditions of these sense devices may be checked by machine 
instructions and used to control program flow. 

The four sense lamps on the panel may be turned on or off by instructions in the 
main program and then checked by the sense instructions. The condition of the lamp 
determines if the program steps are to be skipped. 

The six sense switches may be set on or off from the operator's panel. The 
condition of the switch may then be checked by sense instructions in the program to 
determine whether to skip the following program step. 



6. 2. 00 CUSTOMER ENGINEER'S TEST PANEL 

In addition to the indicators and manual controls on the operator's panel, the 
customer engineer has at his disposal the indicators and controls on the customer 
engineer's test panel. 

The indicators provide a means for checking the address register contents, the 
tally counter, various test triggers, and the cycle time. The switches and jacks 
provide means to continually execute any instruction, control 1-0 operation, control 
B time, and step through instructions cycle by cycle. 

Figure 6. 2-1 shows the layout of indicators and controls for this panel and 
designates system page locations. 

6.2.01 Indicators 

Indicators on the customer engineer's test panel are of the incandescent type. 
Indicators connected to test triggers are on when the trigger is on and off when the 
trigger is off. Indicators concerned with the registers and counters signify a 1 
when they are on and a 0 when off. 

Address Register 

The address register contains the address portion of the instruction under 
execution. 



158 




DATA PROCESSING SYSTEM 




FIGURE 6.2-1. CUSTOMER ENGINEER TEST PANEL 

159 



Cycle Time 

The cycle time indicators indicate in which cycle the machine is currently operating: 
I, E, L, or B time. Also, in connection with cycle time, is the "multiple error" indi- 
cator. This lamp is on whenever the machine is trying to perform two different cycles 
at the same time other than an L cycle and a B cycle, which is a normal share opera- 
tion. Refer to Systems 08. 00. 17. 1 

Tally Counter 

The tally counter differentiates between the L cycles of floating point instructions 
and provides gating for their different operational steps. The tally counter is divided 
into five steps. The lamps on the test panel indicate in which of the five steps the ma- 
chine is currently operating. Refer to Systems 02. 10. 21. 1 and 02. 10. 22. 1. 

T-2 

Indicator T-2 signifies the condition of the T-2 trigger in floating add or subtract, 
multiply, and floating divide. During floating add or subtract, T-2 is used to indicate 
whether or not the multiplier quotient equals 0. During floating divide, T-2 is turned 
on if the quotient is greater than 2. T-2 is turned on at the beginning of a floating 
multiply second step to gate second step operations. The T-2 trigger is found on 
Systems 2. 10.38. 1. 

FP 

The floating point (FP) lamp indicates the condition of the FP trigger on Systems 
2. 10. 29. 1. The trigger is used to store certain conditions throughout the floating 
point operations. The conditions that turn on this trigger and indicator are shown 
in Figure 6. 2-2. 

9 Carry 

This lamp indicates the condition of the 9 carry trigger on Systems 2.10.37.1. 
The trigger is turned on whenever there is a carry from adder position 9. 

9 Overflow 

The 9 overflow lamp signifies the condition of the 9 overflow trigger on Systems 
2. 10. 39. 1. The trigger and lamp come on whenever AC 9=1 during an accumulator 
left shift, or during a multiply add cycle when there is an adder 9 carry. 

Q Carry 

The Q carry lamp indicates the condition of the Q carry trigger on Systems 
2. 10. 36. 1. This trigger is turned on whenever there is a carry out of adder position 
Q. 

Master Stop 

The master stop lamp is turned on whenever the master stop trigger on Systems 
4. 20. 11. 1 is turned on. 



160 



FP ADD/SUB 5th Step 
ACC9=TA7(D1) 2.10.34.1 



FP MPY Rnd Step 
SC = 0 A6(D1) 


2.10.24.1 9 


FP MPY E Time 
MQ = 0 A2(D1) 


2.12.07.1 _ 


FP Div 1st Step 

9 Carry Tgr On A2(D1) 2. 10.41 . 1 _ 


FP Div 3rd Step 

sc = o 


2.10.43.1 _ 


FP 3rd Step Signs Unlike 9 Carry 
Tgr On T2 On A6(D1) 2.10.32.1 r 



OR 



Turn On 
FP TGR 



1 Time ANA/ANS 


AMD 


A9(D1) Turn on Tgr) 




Tgr 








2.09.46.1 










Reset at Lll(Dl) 









CAQ E Time Al 1 


CAQ 
2.09.49.1 


(Turn On Tgr) 








Reset I6(D1) 







FIGURE 6.2-2. AND, CAQ, AND FP TRIGGERS 



Mach 
Auto 




Turn 


On 


Man Ctrl Tgr 


4.20 


.05.1 






Turn 


On 


Start Tgr 


4.20.07.1 



Turn Off 
Man Ctrl Tgr 
4.20.05.1 



Turn Off 
MST Tgr 
4.20.11 .1 



On AO 



Off A8 



A6 



Bring 


Up 


Not B Cyc 


le Intrp 


8.00. 


3.1 



Gate Master 
I Time 
8.00.18.1 



Suppress 
SB to SR 
4.20.14.1 



Op 
to 

4.20. 


Keys 
SR 
14.1 






Suppress 
P.C. Adv 
4.20.14.1 



/ Execute 
/ Inst until 
I One of Three 
VCond Drop 



FIGURE 6.2-3. CONTINUOUS ENTER INSTRUCTION 



End Operation 

The end operation indicator is turned on whenever the end operation trigger on 
Systems 8. 00. 09. 1 is turned on. 

AND 

The AND lamp indicates the condition of the AND trigger on Systems 2. 09. 46. 1. 
It can be used to distinguish between the first and second E cycles of an ANS 
operation. It is on during the first E cycle of an ANS or ANA and off during the 
second E cycle of an ANS. See Figure 6. 2-2. 

CAQ 

The CAQ indicator signifies the condition of the CAQ trigger on Systems 2.09.49.1. 
It denotes the difference between the first and succeeding E cycles of a CAQ instruction. 
The trigger is off for the first E cycle and on for the remaining E cycles and I time of 
next instruction. See Figure 6. 2-2. 

X Carry 

The X carry lamp indicates the condition of the X carry trigger on Systems 
2. 12. 76. 1. The trigger is on when the machine is not in memory nullification mode 
and a carry occurs from adder position 3. If the machine is in memory nullification 
mode, a carry from adder position 4, when in 16K mode, or a carry from adder posi- 
tion 5, when in 24K mode, turns on the trigger. 

6.2.02 Switches 

I-O Interlock Switch 

The I-O interlock switch is effective only when the system is in manual status. It 
has two positions: automatic and manual. With both the automatic -manual and I-O inter- 
lock switches set in the manual position, the computer will stop after executing each 
instruction. With the I-O interlock switch set to automatic, the machine will not stop if 
an I-O device is in operation. The normal setting (automatic) of the I-O interlock switch 
allows the computer to continue at high speed after I-O selection, to allow normal opera- 
tion of the I-O device. The machine will stop after each instruction, providing no I-O 
device or data channel is in use. 

Continuous Enter Instruction (Figure 6.2-3) 

The continuous enter instruction switch is effective in automatic or manual status. 
With this switch on, all instructions are obtained from the operator's panel entry keys, 
not memory. The instruction counter is not used and does not advance. The IC contents 
will not be altered unless a skip , trap , or transfer results from the instruction in the 
entry keys . If the system is in automatic status , the instruction will be executed at 
normal operating speeds; if in manual status, the speed will be under control of multi- 
step or single-step operations. 



162 



Multiple Step High and Low Speed 

The following explanation is with reference to Section 3. 12. 00. With this switch in 
the high position, the multiple step key on the operator's panel performs program steps, 
one after another, every 24 ms. With the switch in the low position, program steps 
are performed every 104 ms. The high-speed position is advantageous when stepping 
through index loops. 

B Cycle Controls 

These switches allow the machine to operate normally when they are in the down 
position. In the up position, they modify normal operation as follows: 

Interrupt: Prevents the 7606 from obtaining a B cycle by interrupting 

a CPU instruction. 

Share: Prevents the 7606 access to core storage during CPU L cycles. 

End Operation: Prevents the 7606 from taking a B cycle when a CPU instruction 
ends operation. 

The switches can be used if the customer engineer wants to test the end operation 
procedure of obtaining a B cycle. The interrupt and share switches would then be put 
in the up position. This prevents a B cycle from being started in any manner except 
end operation. Any of these switches in the up position turns off the ready light. 

Machine Cycle Key (Figure 6.2-4) 

The machine cycle receptacle on the customer engineer's test panel accepts the 
machine cycle key. This key is used to sequentially step through the basic machine 
cycles I, E, and L. When the machine cycle key is inserted into the customer engi- 
neer's panel and pressed, the machine cycle trigger and machine cycle gate trigger are 
turned on at A-0. The machine cycle trigger turns off the MST and allows for the proper 
cycle time, after which the MST is turned on again. The machine cycle gate does two 
things. First, it allows only three shifts per cycle on a shift operation, and forces a 
wait until the shift counter equals zero before ending operation in L time. Second, it is 
used to hold up "manual I time cntl" to insure that the machine will use a full I cycle. 

"Manual I time cntl" is AND'ed with the output of the master I time trigger (Systems 
08. 00. 18. 1). Thus, if "manual I time cntl" drops, I time is finished. Usually, turning 
on the MST at 17 causes "manual I time cntl" to fall and stop I time at 17. This allows 
the machine to finish with an instruction before the following instruction is brought in. 
Normally, the go to I time trigger (Systems 08. 00. 12. 1) is turned off at 19, but because 
there is no 19, it remains on. The all pulse is blocked from resetting the master I time 
trigger (Systems 08. 00. 08. 1) by "minus on not go to I time. " Therefore, if we start 
again, the MST is turned off at A6, bringing up "manual I time cntl" and starting the 
cycle at 16. 

To insure getting a full I cycle when using the machine cycle key, the machine cycle 
gate trigger holds up "manual I time cntl" in the OR circuit on Systems 04. 20. 10. 1. 

When the key is not in use, a plug (sent with the system) that shorts pins 1 and 3 must 
be inserted. 



163 



Machine 
in 

Manual 




Fire Man 
Ctrl SS 



4.20.04.1 



Turn 


On 


Man Ctrl Tgr 


4.20 


05.1 






Turn On 


Mach Cycle 






4.20 


10.1 






Turn Off 


Man Ctrl 


Tgr 




4.20 


05. 1 






Turn 


On 


Mach Cycle 


Gate Tgr 


4.20 


10.1 






Bring Up Man 


1 Time 


Ctrl 


4.20 


16.1 



AO 



Turn Off 


MST Tgr 


4.20 


11.1 






Not E 


Cycle 


Interrupt 


8.00.21 .1 






Gate Master 


1 Time 


8.00 


.18.1 






Execute 


1 Cy 


cle 







A2 



All 



Bring Up 
Turn On 
MST Tgr 

4.20.10.1 



Turn On 
MST Tgr 

4.20.11 .1 



Reset Machine 
Cycle Tgr 

4.20.10.1 



A4 



Reset Mach 
Cycle Gate 
Tgr 



4.20.10.1 



A3 




Fire Man 
Ctrl SS 



4.20.04.1 



Turn On Man 
Ctrl Tgr 

4.20.05.1 







Turn On Mach 
Cycle Tgr 






Turn Off Man 
Ctrl Tgr 

4.20.10.1 







AO 



Turn On Mach 
Cycle Gate 

Tgr 

4.20.10.1 



On 

at 

AO 



Bring Up Man 
Time Ctrl 

4.20.10.1 



Bring Up Turn 
Off MST Tgr 

4.20.10.1 



Turn Off 
MST Tgr 

4.20.11 .1 



A2 



Not B Cycle 
Interrupt 

8.00.21.1 



All 



Gate Next 
Cycle Called 
for by 
Instruction 



Execute the 
Cycle 



Bring Up Turn 
On MST Tgr 

4.20.10.1 



Turn On 
MST Tgr 

4.20.11 .1 



Reset Mach 
Cycle Tgr 

4.20.10.1 



Reset Mach 
Cycle Gate 
Tgr 

4.20.10.1 



( Repeat from 
["A" Until Inst 
\ Complete 



A4 



15 
E5 
L5 



A3 



FIGURE 6.2-4. MACHINE CYCLE KEY 



164 



Auxiliary Start and Reset 

This jack accepts the auxiliary start and reset key. The key is on a long cable, 
giving the customer engineer a means for starting and resetting the machine at 
points other than the console. 

Phone Jack 

The phone jack, in conjunction with the phone jacks on the other units in the system, 
provides a means of communication between customer engineers working at different 
units. 

16K/24K Mode Switch 

This switch is used with the compatibility package. When it is in the 16K position, 
16K core storage positions are available to the 704 program; in the 24K position, 8K 
core storage positions are available to the 704 program. 

DC On 

The DC on switch controls the 400-cycle power supplied only to the 7151. Putting 
the DC on switch in the off position will immediately remove all power to the console, 
except the convenience outlets and the reset motor (operator's keys). All voltages 
should be normal about ten seconds after turning this switch to the on position. 

6.3.00 MARGINAL CHECK 

The system biasing network can be useful to the customer engineer. The controls are 
located on the marginal check console on the 7151. Any single gate or combination of 
gates in any single module, or combination of modules, can be biased at the same time. 
The only exception is the 7302 memory. This module is under control of only one key, A, 
and the whole module will be biased when this key is pressed. 

Each module has a key for selecting it, and each gate has a key with key A for gate 
A, B for gate B, etc. 

When biasing, all gates must be selected prior to varying the voltage. After the 
voltage has been varied, another gate cannot be selected until returning to normal volt- 
age. If gate A is being biased and it is decided to bias gate B instead, gate A MC relay 
must be dropped out; therefore it will be necessary to take the MC voltage to normal 
before selecting gate B. If this is not done, gate A MC relay will have a hold through 
the B MC relay points. This means that both gates A and B would be biased instead of 
gate B only, as desired. 

It is also possible to vary the +30v and +60v in the 7302. These controls are also 
located in the 7151, on the MC panel. 

When varying the different voltages , there are two meters to monitor the amount of 
voltage being varied. One meter is for the +30 and +60 in the 7302, and one meter, for 
the +6 and -12 for the rest of the system. The meters indicate what the voltage is if 
the MC relays are picked and the points are properly adjusted. A periodic check of the 
voltages, while biasing, should be made. 



165 



7. 0. 00 REFERENCE INFORMATION 



7. 1. 00 CONDENSED LOGIC 

7. 1. 01 Adders (Systems 02. 02. 01. 1-02. 02. 37. 1) 

The adders consist of transistor switching circuits for combining binary numbers 
into a binary sum. The 7090 can only add, therefore control lines are needed to develop 
true and complement conditions. 

ACCtoADD 02.12.24.1 

SR to ADD 02.12.17.1 

XR to ADD 02.12.19.1 

COMP ACCtoADD 02.12.23.1 

Adders are used for many different types of operations and some controls will affect 
only certain adders. The adders have three types of outputs: sum, carry, and looka- 
head. Section 3 covers the theory of the adder outputs. 

7. 1. 02 Address Register (Systems 03. 06. 00. 1-03. 06. 04. 1) 

The address register is a 15-position register of triggers. It is labeled 3 through 
17. The address register signals the desired address to the core control circuits 
(Figure 7. 1-1). Control lines for the address register are: 

Address Switches to AR 03. 06. 05. 1 
ARtoPC 03.06.05.1 

7 . 1 . 03 Program Register (Systems 03 . 04 . 00 . 1- 03 . 04 . 03 . 1) 

The program register is made up of ten positions , and is used for decoding the 
instructions during I time. Lines controlling the input and output of the program register 
(Figure 7.1-2) are: 

SRtoPR 02.11.40.1 
OPKtoPR 02.12.09.1 
SB to PR 02.05.10.1 



7. 1. 04 Sense Indicators (Systems 02. 06. 00. 1-02. 06.35. 1) 

The sense indicator register is a 36-position register of triggers. There are two 
triggers to each position (Figure 7 . 1-3) . Lines controlling the sense indicators are: 



Reset PR 



02.11.40.1 



COMP SI to SR 
SI to SR 



Invert SI 
Set IND 



02.12.61.1 
02. 12.63. 1 
02.12.12. 1 
02. 12.62. 1 



166 



AR to PC 



Minus On AS to AR 



-AS Output 



Plus On AS to AR 



Reset AR 



+BTin 



+o 



-TOA 



+R 



+A 



+Set PC 17 



+MF AR Line 



7.1-1. ADDRESS REGISTER 



SB 3-1 1 to PR 



















MF SB 


+o 






+A 




+TOA 


Output of PR 


OPK-PR 






Reset Proa Reg 










-R 



7.1-2. PROGRAM REGISTER 



+SR - SI 



+Set Ind 



Invert SI 



-SR -SI 



-Reset SI 



Gate SI - SR 



+A 



-A 



Comp SI - SR 



+TOA 



-R 



+A 



+TOA 



+A 



Comp Output 



+A 



SI Output 



7.1-3. SENSE INDICATOR 



167 



The "invert SI" has no effect on the SI position if there is no bit in the corresponding 
position of the storage register. With a bit in the SR and the invert line active, the 
information in the SI will be inverted. 

7.1. 05 Shift Counter (Systems 03. 04. 14. 1-03. 04. 19. 1) 

The shift counter is an 18-position counter of triggers. It is a step-down counter 
when used for shifting. The shift counter is also used as part of the program register 
for certain instructions. During a shifting operation, the counter will be stepped every 
clock pulse (Figure 3. 1-7 A). Lines controlling the shift counter are: 

AStoSC 02.11.78.1 
Step SC 02.11.79.1 

7. 1. 06 Program Counter (Systems 03. 05. 00. 1-03. 05. 07. 1) 

The program counter is a 16-position counter of triggers. These positions are 
labeled 2 through 17 (Figure 3. 1-7B). Lines controlling the program counter are: 

ADV PROG CTR 02.11.51.1 
PC to AS 03.05.09.1 

The program counter is a count-up counter, and can sequentially step through a 
program. 

7.1.07 Accumulator (Systems 02.03.00.1-02.03.37.1) 

The accumulator is a 38-position register of shift cells. Some trouble may result 
from the "CP set" being in error. This is true for all registers made up of shift cells. 
Do not vary the "CP set" until all other possibilities have been checked. Refer to 
Section 7 for adjustment of the "CP set. " Lines controlling the accumulator are shown 
in Figure 7 . 1-5 . 



7 . 1. 08 Multiplier Quotient (Systems 02 . 04. 00. 1-02 . 04. 35. 1) 

The MQ is a 36-position register of shift cells. The MQ is used on multiply and 
divide operations , although some other operations may use it (Figure 7 . 1-4) . Lines 
that control the MQ are: 



Adder to AC 



Set ACC 
Hold ACC 



Shift Right 
Shift Left 
SR to ACC 



02.12.36.1 
02.12.35.1 
02. 10. 15. 1 
02.12.32.1 
02. 05. 03. 1 
02.05.03.1 



SR to MQ 
Shift MQ Left 
Shift MQ Right 
Set MQ 
Hold MQ 



02. 12.40. 1 
02. 12.44. 1 
02. 12.45. 1 




168 



Gate Shift Left 



-A 



Left Out 



MQ Right In 
MQ Left In 
SR to MQ 



+TOA 



+TOA 



-A 



Right Out 



+ Set MQ 



-HnlH MQ 

Gate Shift Right 



-A 



Gate MQ to SR 



SR - MQ 



7.1-4. MQ POSITION 



Gate AC - SR 



AC - SR 



AC Left In 

AC Right In 
AD to AC 



+TAO 



+TAO 



+Set AC 



-R 



-R 



-Hold Acc 
Gate Shift Right 



Right Out 



Gate Shift Left 



Left Out 



Gate AC - AD 



AC - AD 



-Gate Not AC - AD (Comp) 



Not Acc to AD 
(Comp) 



7.1-5. ACCUMULATOR REGISTER 



169 



7. 1. 09 Index Registers (Systems 02. 07. 01. 1-02. 07. 15. 1) 

The index registers are three identical 15-position registers using shift cells. When 
the registers are read out, the information comes out in complement form (Figure 
7. 1-6). Lines controlling the index register are: 



ADD to XR 02.12.70.1 
Gate XRA to ADD 02 . 12 . 26 . 1 

Gate XRB to ADD 02.12.26.1 
Gate XRC to ADD 02.12.26.1 

Set XR f 02. 12.72. 1 and 



Hold XR 02.12.73.1 



7.1. 10 Storage Register (Systems 02. 01. 00. 1-02. 01.37. 1) 



The storage register is a 36-position register of shift cells. The storage register 
has eight inputs with the following controlling lines (Figure 7. 1-7). 



ACC to SR 
ADD to SR 
MQ to SR 
OP Keys to SR 
SR to SR 
IND to SR 

Address Switch to SR 
SB to SR 
Set SRR 
Hold SR 



02.12.03.1 
02. 12. 05. 1 
02. 12. 08. 1 
02. 12. 09. 1 
02. 12. 10. 1 
02. 12. 13. 1 
03. 06. 12. 1 
02. 12.50. 1 
02. 05. 00. 1 
02. 05. 00. 1 



7.2.00 SERVICE AIDS 



7.2.01 One Card Programs 



Programs other than the normal diagnostic programs may be used to troubleshoot 
the machine. For instance, in diagnosing troubles which appear only when the cus- 
tomer's program is being run, the program may be altered slightly to isolate the 
trouble. Then, if the program is one used regularly, it becomes a good diagnostic in its 
altered form. In cases of this kind, pass along the information to allow newly released 
diagnostic programs to incorporate it. 

Short programs that you write yourself are also handy when working on a machine. 
Punch these programs on cards and save the time used to enter them in storage with 
the keys. Make each card self-loading, if possible, and there will be less cards to 
keep track of. Keep a file of these one-card programs and add to it. A few samples 
of one-card programs are given below. 



Display Storage 



This program causes display of the contents of sequential storage locations , starting 
with the location entered in the operator's panel keys. The card is self-loading and 
halts on its first pass to allow the operator's panel keys to be set. After the start key 



170 



+PAD15 - XR15 



+N Set XRA 



+N Hold XRA 



-P Gate XRC 



AO. 



+N Set XRB 



+N Hold XRB 



-P Gate XRC 



TAO 



-R 



TAO 



+N Set XRC 



+N Hold XRC 



-P Gate XRC - AD 



+P Gate XR - AD 



TAO 



TAO 



-R 



TAO 



-R 



TAO 



-A 



-A 



XRA Outp ut 



XRB Output 



XRC Output 



FIGURE 7.1-6. INDEX REGISTER 



Output 
To Adder 



Acc - SR 



MQ - SR 



AS - SR 



MF SB - SR 



Adder to SR 



SI to SR 



Comp SI to SR 



Gate OPK 



OPK 



+ Set SR 



-Hold SR 



Gate SR to Adder 



Gate SR to Adder 



Gate SR to SB 



-A 



-Gate SR - SR 



+TAO 



-R 



+TAO 



_zR_ 



-SR -SI 



-A 



-A 



SR to MQ 



SR to ADD 



MFSB Out 



FIGURE 7.1-7. STORAGE REGISTER 



171 



is pressed, the program halts again. At this time, the number of the storage location 
is seen in the accumulator and the contents of the storage location are seen in the MQ. 
Each time the start key is pressed, the number and contents of the next sequential 
storage location are displayed. If it is desired to display storage at a new location, 
press the reset key, place the new address in the operator's panel keys, and start. 



Instructions to be punched in the card are: 



Op Deer Tag Adr 

0 IOCD 12 00000 

1 HPR 
2 

3 NOP* 

4 NOP* 

5 ENK 

6 XCA 

7 STA 00005 

10 LDQ 00000 

11 HTR 00007 

12 ADD 00011 

13 TRA 00004 

14 HTR 00001 



Read 12 words starting at 0. 
Halt to set keys. 

Location of this instruction becomes 
0000. 

Keys to MQ. 
MQ to Acc. 

Address of Acc to 00005. 

Load MQ from address in Acc. 

MQ contains word whose address is in 

Acc. 

Step address in Acc by one. 
Repeat. 



* These instructions are used so this program will not be destroyed even if a 
diagnostic program using a trapping mode is later run on the machine. 



Store Address 



The following program fills each memory location with its corresponding address. 
The program itself only takes 12 positions in upper memory. It is designed so that if 
sense switch 1 is left up, addresses are stored in all memory locations from 00000 to 
77773 before the program destroys itself. If sense switch 1 is placed down before the 
card is loaded, the program stops to allow the operator to enter an address on the keys. 
When the start key is pressed, the machine stores addresses in sequential locations, 
starting at the address placed in the operator's panel keys. 



Instructions to be punched in the card are: 



Op Deer Tag Adr 

0 IOCD 14 77764 

1 TCOA 00001 

2 TRA 77764 

3 PSE 00161 

4 TRA 77772 

5 HPR 

6 ENK 

7 XCA 

10 TRA 77773 

11 CLM 



Location of this instruction becomes 
77764. 

Halt to enter address on keys. 



172 



Op Deer Tag Adr 

12 STA 77774 

13 STO 00000 

14 ADD 77777 

15 TRA 77773 

16 HTR 00001 



Search for Location of a Word ' 



This program looks through storage until it finds the location of any 36-bit word 
entered on the operator's panel keys. When the memory location of the word is found, 
the program halts and the location may be read from the address portion of the MQ. 
If the start key is pushed again, the program continues to search sequential memory 
locations. The complete contents of storage, starting from location 20, are searched. 





Op 


Deer 


Tag 


Adr 


0 


IOCD 


15 




00003 


1 


HPR 








2 


ENK 








3 


STQ 






00017 


4 


CLA 






00020 


5 


CAS 






00017 


6 


TRA 






00010 


7 


TRA 






00014 


10 


CLA 






00004 


11 


ADD 






00016 


12 


STA 






00004 


13 


TRA 






00004 


14 


LDQ 






00004 


15 


HTR 






00010 


16 


HTR 






00001 


17 


HTR 






00000 



Halt to set keys. 



Read location from address part of MQ 



Search for Location of an Operation Code 



This program finds the location of any operation code entered on keys S, 1-11. Keys 
corresponding to bit positions 12-35 must be left up. 





Op 


Deer Tag 


Adr 


0 


IOCD 


16 


00003 


1 


HPR 




00001 


2 


ENK 






3 


STQ 




00020 


4 


CLA 




00021 


5 


ARS 




00030 


6 


ALS 




00030 


7 X 


CAS 




00020 


10 


TRA 




00012 


11 


TRA 




00016 


12 


CLA 




00004 


13 


ADD 




00001 


14 


STA 




00004 



Halt to set keys. 



173 



15 
16 
17 
20 



Op 
TRA 
LDQ 
HTR 
HTR 



Deer 



Tag 



Adr 
00004 
00004 
00012 
00000 



Read location from address part of MQ 



This program may be easily modified to allow it to search memory for a specific 
address rather than for an operation code. The only change necessary isto enter 
instruction ALS 00025 in location 5 and instruction ARS 00025 in location 6. 

7.2.02 Voltage 

Proper sequence for bringing up power is: 

1. Press power on reset key on 7618. 

2. Reset MG CB1 on 7608. 

3. Press power on switch on 7618 or 7151. 

Note: Failure to follow this sequence may cause a blown fuse in the 48-volt supply. 
High resistant fuses or bad fuse clips may cause a voltage drop across the fuse large 
enough to cause intermittent system trouble. A voltage drop of 0. 1 volt across a fuse 
indicates a defective fuse, fuse holder, or connection. 

It is possible to have a power supply circuit breaker in an SMS frame partially open 
without mechanically tripping the breaker. This may cause one phase to be lost to the 
SMS frame power supply. A quick check for this condition is to observe the 400-cycle 
volt meter on the 7618. This condition (loss of one phase in some power supply) will 
usually be indicated by a larger spread in the voltage reading of the three phases. The 
normal readings should be recorded for future reference. This procedure is not 100 
per cent effective, but will detect a large percentage of single-phased power supplies. 

When installing engineering changes, a periodic check of resistance between -6 and 
ground will catch wiring errors, where the shield is tied to the wrong pin. Although 
normal resistance is low when using a low scale on the ohmmeter, a change of resist- 
ance will be indicated if an error is made. 

Blower Motors 

All blower motors, P/N 598593, in the 7090 system are 1/30 horsepower, with 
exception of memory, which uses a 1/8 horsepower motor, P/N 598594. These blower 
motors all rotate clockwise when viewed from the hinged end of the gate. 

7. 2. 03 Adjustment of C Pulse Set (Figure 7. 2-1) 

General operation of a shift cell is described in Section 3. The setting and timing 
of the C pulse set line is very important. 

1. Make sure that the oscilloscope being used has probe leads of the same length. 

2. Synchronize the scope on +N pulse at 02A2C15F on Systems 02. 05. 11. 1. This 
pulse is an A1D1 pulse. Check the following pulses; they should be 182 + 15-45 
nanoseconds in duration, and should repeat themselves every 2. 18 microseconds. 



174 



CLOCK 



OSCILLATOR 



(+N) AO Dl 



Test pt. 

03A-4E17A 

on Systems 8 .00.40. 1 



. 1 psec/cm 
. 1 volt/cm 
lOx attenuation 
+ internal sync 




(+P) A2 D2 



Test pt. 

03A 

4D18F 

on Systems 8.00.40.1 



. 1 psec/cm 
. 1 volt/cm 
lOx attenuation 
AC level 
+ internal sync 



Odd Clock Drive 

Test pt. . 1 psec/cm 

03A .1 volt/cm 

4C15F 1 Ox attenuation 

on Systems 8. 00. 44. 1 AC level 

+ internal sync 

























































0 


++++ 






++++ 

























(+N) AO (D2) 



Test pt. 

03A 

4DI8B 

on Systems 8.00.40. 1 



. 1 psec/cm 
. 1 volt/cm 
lOx attenuation 
+ internal sync 

















71 


ft'inn, 









(-N)All (Dl) 



Test pt. 

03A 

4D17D 

on Systems 8.00.40.1 



. 1 psec/cm 
. 1 volt/cm 
1 Ox attenuation 
+ internal sync 



f 



-N) Al Dl 



Clock Trigger 1 




Odd and Even Drive 

Top Trace: Even Clock Drive 
Test pt. 
03A 
4C16F 

on Systems 8.00.44.1 

Bottom Trace: Odd Clock Drive 
Test pt. 
03A 
4C15F 

on Systems 8.00.44. 1 



.1 psec/cm 
. 1 volt/cm 



1 Ox attenuation 
+ internal sync 



Test pt. 

03A 

4F18G 

on Systems 8.00.40. 1 



. 1 psec/cm 
. 1 volt/cm 
lOx attenuation 
AC level 
+ internal sync 



Test pt . .1 psec/ cm 

03A . 1 volt/cm 

4E1 7B 1 Ox attenuation 

on Systems 8.00.40.1 + internal sync 



FIGURE 7.2-1. MULTIPLEXOR PULSE WAVE FORMS 



175 



+N A2D1 02A2C13B 

+N A3D1 02A2D20C 

+P A4D1 02A3F13B 



The time between the A2D1 rising through ground potential, and the A3D1 pulse rising 
through ground potential, must be 182 (-0, +40) nanoseconds. This is also true of 
A3D1 and A4D1. The time between A2D1 and A4D1 must be 356 (-0, +40) nanoseconds. 
The distance between the leading edges of any two Dl pulses at the point of distribution 
to logic blocks should be within 50 nanoseconds of multiples of 182 nanoseconds. 

3. After checking the clock pulses, sync on I time (02A2D03D) with a continuous 
enter instruction of LDQ (+0560). Check the following MQ test points, with the C pulse 
set being wholly contained in the gate for each set §f points. This is accomplished by 
varying the delay line located in 03B3. Remember that the pulses are negative going 
pulses. 



CP Set 

02A2H18C 

02A2H18E 

02A2H25C 

02A2H25E 



Gate 

02A2H18E 
02A2H18F 
02A2H25D 
02A2H25F 



Systems 
02.05.04.1 
02.05.05. 1 
02.05.04.1 
02.05.04.1 



4. While still synchronized on I time, change the instruction (still under continuous 
enter instruction) from LDQ to CLA (+0500). Check the following points that the C 
pulse set is wholly contained within the gate for each point given. Vary the same delay 
line used for the MQ positions. 



02A2J18C 
02A2J18E 
A2A2J23C 
02A2J23E 



02A2J18D 
02A2J18F 
02A2J23D 
02A2J23F 



02.05.02.1 
02.05.02.1 
02.05.02.1 
02.05.02.1 



The setting of the delay line should meet conditions set in both 3 and 4, the CP set 
contained within all B gates. This will adjust the set and hold pulses for the shift cells. 



7. 3. 00 OPERATOR'S PANEL 



7. 3. 01 CONSOLE INDICATORS 



Indicators 


Systems 


Driver Indicator - Systems 


ACC Indicators 


00.20.30.0 


2.03.00.1 to 2.03.37.1 


ACC Overflow 


00.20.14.0 


02. 10.36. 1 


Address Reg (3-17) 


00.30.60.0 


3.06.00. lto 3.06.04.1 


AND 


00.20.19.0 


2.09.46.1 


Automatic 


00.20.41. 0 


4.20.13.1 


B Time 


00.80.00.0 


8.00.21.1 


CAQ 


00.20.19.0 


2.09.49.1 


Channel Selected (A-H) 


00.60.00.0 


6.00.00.1 to 6.00.01.1 


Channel Tape Check (A-H) 


00.60.01.0 


60.32.02.2 


Central Word Trap (A-H) 


00.60.03.0 


60.38.03.1 


Divide Check 


00.20.41.1 


2.10.53.1 


E Time 


00.80.00.0 


8.00.19.1 



176 



Indicators 


Systems 


Driver Indicator - Systems 


End OP 


00.20. 19. 0 


8. 00. 09. 1 


FP 


00.20. 19. 0 


2. 10.29. 1 


I Time 


00.80.00.0 


8.00.18.0 


I-O Check 


00.20.41. 0 


2. 10.53. 1 


Index Reg A-B-C 


00.20.70. 0 


2.70. 01. 1 to 2. 07. 15. 1 


L Time 


00. 80. 00. 0 


8. 00.20. 1 


Master Stop 


00.20. 19. 0 


4.20. 11. 1 


MQ Indicators 


00.20.40. 0 


2. 04. 00. 1 to 2. 04.35. 1 


MQ Overflow 


00.20. 14. 0 


02.10.51.1 


Multiple Time Error 


00. 80. 00. 0 


8. 00. 17. 1 


Program Counter (3-17) 


00.30.40. 0 


3.05.00.1 to 3.05.07.1 


Program Register (S, 1-9) 


00.30.50. 0 


3.04.00.1 to 3.04.03.1 


Program Counter (3-17) 


00.30.40. 0 


3. 05. 00. 1 to 3. 05. 07. 1 


Q Carry 


00.20.19.0 


2. 10.36. 1 


R-W Select 


00.20. 14. 0 


6. 00. 02. 1 


Ready 


00.20.41.0 


4.20. 13. 1 


Sense Lights (1,2,3,4) 


00.20.90.0 


2. 09.60. 1 


Shift Counter (10-17) 


00.30.40.0 


3.04.14. 1 to 3.04.17.1 


Simulate 


00.20.14.0 


2. 10. 70. 1 


SR Indicators 


00.20.11.0 


2. 01. 00. 1 to 2. 01.35. 1 


T2 


00.20.19.0 


2.10.38.1 


Tally Counter (1-5) 


00.20.17.0 


2. 10.21. 1 to 2. 10.22. 1 


Tape Check Trap (A-H) 


00.60. 02. 0 


60.38.03.1 


Trap 


00.20.14.0 


2. 10.53. 1 


Trap Control Indicators 


00.60.02.0 


2.10.56.1 


X Carry (AD- 3) 


00.20.19.0 


2.12.76.1 


9 Carry 


00.20.19.0 


2.10.37.1 


9 Overflow 


02.20.19.0 


2. 10.39. 1 



7.3.02 Indicator Lights 

Indicator lights are small incandescent lamps rated at 10 volts, 15 ma. Power is 
brought in through a two-pin base. One pin is connected to the yellow input signal cable, 
while the other is returned to -12 volts (violet wire). 

Removal and Replacement 

Some machines use special clips to hold the indicator lights; others use regular 
sockets. Open the back panel to make sure of which you have. Regular sockets present 
no problem; merely pull out the old light and push in a new one to replace it. If special 
clips are used, it may be necessary to remove the voltage leads before taking out the 
light. If this is the case, flip the console DC-off switch to knock down power before 
removing the leads . Then use a plier , wrench , or special tool , if it is available , to 
loosen the clip and remove the light. These indicator lights are somewhat delicate, so 
use care when replacing them. 

Refer to Section 7. 3. 01, Service Aids, for a list of indicator lights and corresponding 
Systems pages. 



177 



7. 3. 03 Unitized Assembly Lights and Keys 

Unitized assemblies use telephone-type lights. Some operate on 48 volts and some 
on 6 volts. Be sure to use the correct replacement for each bulb. 

Removal and Replacement 

To remove the plastic cover over the light or key assembly, press in on one side of 
the cover and work it out of its holder. The light bulb is removed by grasping it on the 
end and pulling straight out. To replace, reverse the procedure. 

7.3.04 Switches and Keys 

To gain access to the switches and keys on the operator's panel, the panel must be 
tilted up. To do this, three latches must be released. Release the latches by inserting 
a screw driver in each latch hole^, one after the other, and pressing in. The latch holes 
are located across the front, underneath the shelf. 

Adjustment 

It may become necessary to adjust the switches so that the reset motor will return 
all of them to the OFF position at the same time. The switches can be adjusted up or 
down and in or out. Usually best results will be obtained if the bottom nut is lowered 
as close to the base of the switch as is possible. In this way the switch lever is brought 
as deeply as possible into the plastic rocker. 

Removal and Replacement 

To remove a switch, it may be necessary to loosen the bar upon which all the switches 
are mounted. This bar is held by two screws at either end. Removing the bar will not 
affect the plastic rockers , for they are held by a single shaft which is independent of 
the switches. 

7.3.05 Plastic Rockers 

Plastic rockers are used to actuate toggle switches mounted underneath the panel. 
They may require replacement if they become chipped or broken. 

Removal and Replacement 

Removal of one or more plastic rockers requires the removal of the assembly upon 
which all the toggle switches are mounted. Two nuts at either end are removed to take 
off the assembly. The shaft on which the rockers are strung can then be pulled out and 
any or all of the rockers can be taken off. New rockers may then be slipped on the 
shaft and the shaft put back in its proper place on the panel. 

7.3.06 Reset Motor 

There are two 115-volt reset motors in the console, one whose shaft rotates 60 rpm 
clockwise, and the other 60 rpm counterclockwise. A manufacturer's part number is 
stamped on each motor. The number ending in the letter J identifies the right-hand 
motor. The left-hand motor is stamped with a number ending in the letter K. 



178 



Service Checks 

If the motor will not operate, check the plug connection and also check for a blown 
fuse. The fuse is located under the right-hand motor mounting bracket. 

Adjustment 

A slight adjustment of the relative' position of the motors can be made by loosening 
the mounting screws, moving the motor, and retightening the screws. 

Removal and Replacement 

The right-hand motor may be removed by taking out the mounting screws and mounting 
bracket, and then slipping the shaft out of the rubber coupling sleeve after the set screw 
is loosened. 

Removing and replacing the left-hand motor is somewhat more involved. There is 
little or no room to move the motor to the left, out of the coupling sleeve; therefore, 
the coupling sleeve must be moved to the right, away from the motor. To do this, the 
right-hand motor must be taken out, together with the reset bar and its three mounting 
brackets. Use the following step-by-step procedure: 

1. Loosen all set screws in the coupling sleeves on both motors. 

2. Take out the screws holding the right-hand motor mounting bracket to the next 
bracket. 

3. Take out the screws holding the right-hand motor to the mounting bracket. 

4. Unplug and remove the motor. Remove the right-hand coupling sleeve from 
the reset bar. 

5. Take off the reset bar's three mounting brackets and remove the entire assembly. 
Take the coupling sleeve off the left-hand reset motor shaft. 

6. Now the screws securing the left motor to its mounting bracket and the bracket 
to the next bracket can be removed. 

7. Unplug and lift out the motor. 

To replace the motor, reverse the procedure. Before closing the panel, be sure the 
reset bar is positioned so that its blade faces the operator and points downward. 

7.4.00 CE PANEL 

7.4.01 Indicator Lights 

The indicator lights used in the CE panel are identical to those used in the operator 's 
panel. For information concerning these lights, consult Section 7.3. 02. 

7 . 4. 02 Switches and Receptacles 

Switches used on the CE panel are double-throw toggle switches. In addition to these, 
there are two Jones plug receptacles into which external keys on cables can be connected. 
If the keys are not connected, pins 3 and 4 of the receptacle must be connected together. 
This is generally done by means of a special shorting plug. 



179 



Removal and Replacement 

Access to the switches and receptacles is obtained by opening the rear panel. The 
Jones plug receptacles are removed by taking off the back retaining plate which is se- 
cured by three nuts. Rubber washers are used to hold the plug retaining tabs in place. 

For safety reasons, if the console DC-off switch is to be removed, the wall switch 
must be opened or the emergency OFF switch must be pulled first before the wires are 
disconnected. 

7.5.00 MARGINAL CHECK PANEL 

The marginal check panel contains marginal check (MC) switches, motor Variac* 
control switches, and two voltmeters. Normally the panel is covered. The cover is 
opened by tripping a lever located on the right side of the Console, under the shelf. 
Provision for marginal checking the Console is placed in the MC panel. However, this 
feature will not be used unless transistor cards are built into the unit. 

7. 5. 01 MC Switches 

Service Check 

If an MC switch fails to make contact, voltages will not be varied in the frame or 
gate chosen. However, the marginal check voltmeter will indicate just as if everything 
were operating correctly. Therefore, if trouble is suspected with any of the switches, 
check the voltages on the frame or gate in question with a voltmeter to see if they act- 
ually change as they should. Sometimes one can determine by listening whether the 
marginal check relays in the power supply have been picked when the MC switches have 
closed. 

Adjustment 

No adjustment is provided on these switches. Usually, if a switch is bad, the entire 
assembly must be replaced. 

Removal and Replacement 

In order to remove the MC switches, the front curved panel of the console must be 
removed. To do this, first remove the front base panel by pulling out. This exposes 
the bottom row of screws on the curved panel. Lifting up the entry key panel exposes 
the top row of screws. Take out all these screws and remove the panel. Now look 
underneath the marginal check panel. There is a protective shield located under the 
panel and beneath it are two MC switch assemblies mounted by a screw on either end 
to mounting pedestals. Once these screws are removed, the entire assembly can be 
dropped. Throw the console DC off before starting. 

7.5.02 MC Meters 

These two meters monitor the variable voltages used for biasing. The MC meter 
is an ac voltmeter and measures only the amount a voltage is being biased if the MC 
relay for the module has been picked. If there is any doubt as to the accuracy of a 
bias limit, the voltage should be checked at the actual gate being biased. 
* Trademark of General Radio Company 



180 



7.6.00 TAILGATE 



The tailgate area contains all the signal and power connectors that enter and leave 
the console. It is located in gate H of the console frame. See Figure 7.6-1. 

7 . 6. 01 Signal Connectors 

The tailgate contains twelve signal connectors, sometimes called "biscuits," each 
of which holds 40 conductors . 

7. 6. 02 Power Connectors 

Three Winchester male power connectors are mounted at the base of the tailgate 
assembly, at an angle to the vertical signal connector portion. They consist of a 104- 
conductor, a 34-conductor , and a 75-conductor connection. The 104-conductor cable 
contains the marginal checking control lines, the 34-conductor cable contains the 400- 
cycle lines from the power distribution frame (PDF), and the 75-conductor cable con- 
tains the 60-cycle power and other miscellaneous control lines to and from the PDF. 

Removal and Replacement 

Be sure the marginal check voltages are all at normal before removing the 104- 
conductor cable. The three-power connectors can be removed from the console in any 
order. When replacing cables, hold the connector with its female lug on the left side as 
it faces the tailgate. 



181 




TAIL GATE 



SIGNAL CONNECTORS 
12-40 CONNECTORS 
OPEN WIRE 

■POWER CONNECTORS 
-75 CONDUCTOR 
-34 CONDUCTOR 

104 CONDUCTOR 



TAIL GATE (FRONT VIEW) 



CABLE CONNECTIONS 


CONSOLE TO 




M F 1 


MF 2 


MULT - 
P .FXOR 


08H0IA 




0IE2IF 






08H05A 




0IF37F 






08H09A 




0IE2IC 






08H0IB 




0IE2ID 






08H05B 




0IF45C 






08H09B 




0IF37G 






08H0IC 




0IE2IG 






08H05C 




0IE2IE 






08H09C 








03F37G 


08H0ID 






02E25C 




08H05D 






02E25D 




08H09D 






02F33G 





FIGURE 7.6-1. CONSOLE GATES AND TAILGATE 



Appendix A 

Alphabetic Listing and Index of 7090 Instructions 



OPERATION CODE 
ALPHA OCTAL 



ACL 


0361 




ADD 


0400 




ADM 


0401 




ALS 


0767 




ANA 


—0320 




ANS 


0320 




ARS 


0771 




AXC 


— U/ ft 




AXT 


0774 




BSF 


—0764 




BSR 


0764 




BTT 


0760. 


.xxxx 


CAL 


—0500 




CAQ 


—0114 




CAS 


0340 




CHS 


0760. 


.0002 


CLA 


0500 




CLM 


0760. 


.0000 


CLS 


0502 




COM 


0760. 


.0006 


CRQ 


—0154 




CVR 


0114 




DCT 


0760. 


.0012 


DVH 


0220 




DVP 


0221 




ECTM 


—0760. 


.0006 


EFTM 


—0760. 


.0002 


ENB 


0564 




ENK 


0760. 


.0004 


ERA 


0322 




ESNT 


—0021 





ESTM 

ETM 

ETT 

FAD 

FAM 

FDH 

FDP 

FMP 

FRN 

FSB 

FSM 

HPR 

HTR 

IIA 

IIL 

IIR 

IIS 

IOT 
LAC 



.0005 
.0007 
xxxx 



.0011 



-0760. 
0760. 

-0760. 
0300 
0304 
0240 
0241 
0260 
0760. 
0302 
0306 
0420 
0000 
0041 

-0051 
0051 

0440 



0760.. 0005 
0535 



LAS —0340 



LBT 
LCHA 
LCHB —0544 
LCHC 0545 
LCHD —0545 
LCHE 0546 
LCHF —0546 
LCHG 0547 
LCHH —0547 
LDC —0535 



0760. .0001 
0544 



INSTRUCTION 



KM 

X 

w 

a us 
5 5< 



II 

3 o 



Add and Carry Logical Word X X 

Add XX 

Add Magnitude X X 

Accumulator Left Shift X 

AND to Accumulator « X X 

AND to Storage X X 

Accumulator Right Shift X 

Address to Index Comple- 
mented 

Address to Index True 

Backspace File X 

Backspace Record X 

Beginning of Tape Test X 

Clear and Add Logical Word X X 
Convert by Addition from 

MQ 

Compare AC with storage XX 

Change Sign X 

Clear and Add X X 

Clear Magnitude X 

Clear and Subtract X X 

Complement Magnitude X 

Convert by Replacement from 

MQ 

Convert by Replacement from 

AC 

Divide Check Test X 

Divide or Halt X X 

Divide or Proceed X X 

Enter Copy Trap Mode X 

Enter Floating Trap Mode X 

Enable from Y X X 

Enter Keys X X 

Exclusive OR to Accumulator X X 
Enter Storage Null. 

and Transfer X X 

Enter Select Trap Mode X 

Enter Trapping Mode X 

End of Tape Test X 

Floating Add X X 

Floating Add Magnitude X X 

Floating Divide or Halt X X 

Floating Divide or Proceed ... X X 

Floating Multiply X X 

Floating Round X 

Floating Subtract X X 

Floating Subtract Magnitude X X 

Halt and Proceed 

Halt and Transfer X X 

Invert Indicators from AC 

Invert Indicators of Left Half 
Invert Indicators of Right 

Half 

Invert Indicators from Stor- 
age XX 

Input-Output Check Test . .. XX 
Load Complement of Address 

in Index 

Logical Compare Accumula- 
tor with Storage X X 

Low- Order Bit Test X 

Load Channel A XX 

Load Channel B X X 

Load Channel C XX 

Load Channel D XX 

Load Channel E X X 

Load Channel F X X 

Load Channel G XX 

Load Channel H XX 

Load Complement of Decre- 
ment in XR 



60 
58 
60 
52 
128 
128 
55 

126 
126 
* 
* 
107 
58 

137 
99 
1 1 1 

55 
68 
55 
68 

135 

133 
104 

63 
67 



* 
52 
128 

* 
* 
97 
107 
71 
79 
85 
91 
79 
85 
79 
79 
107 
107 
1 16 
1 14 

I 14 

1 1 1 

104 

126 

102 

99 



OPERATION CODE 
ALPHA OCTAL 

LDI 0441 

LDQ 0560 

LFT —0054 

LFTM —0760. .0004 

LGL —0763 

LGR —0765 

LLS 0763 

LNT —0056 

LRS 0765 

LSNM —0760. .0010 



LTM 
LXA 
LXD 



— 0760 . .0007 

0534 
—0534 



MPR —0200 
MPY 0200 



MSE 
NOP 
NZT 
OAI 

OFT 

ONT 

ORA 

ORS 

OSI 

PAC 

PAI 

PAX 
PBT 
PDC 

PDX 
PIA 

PSE 

PXA 

PXD 

RCHA 

RCHB 

RCHC 

RCHD 

RCHE 

RCHF 

RCHG 

RCHH 

RCT 

RDCA 

RDCB 

RDCC 

RDCD 

RDCE 

RDCF 

RDCG 

RDCH 

RDS 

REW 

RFT 



— 0760 

0761 
—0520 

0043 

0444 

0446 
—0501 
—0602 

0442 

0737 

0044 

0734 
—0760. .0001 
—0737 

—0734 
—0046 



0760 

0754 
-0754 

0540 
-0540 

0541 
-0541 

0542 
-0542 

0543 
-0543 

0760. 

0760. 

0760. 

0760. 

0760. 

0760. 

0760. 

0760. 

0760. 

0762 

0772 

0054 



.0014 
.1352 
.2352 
.3352 
.4352 
.5352 
.6352 
.7352 
10352 



RIA —0042 



RIL 
RIR 

RIS 

RND 

RNT 



-0057 
0057 

0445 

0760. .0010 
0056 




RQL —0773 



INSTRUCTION 



Load Indicators XX 1 1 1 

Load MQ XX 50 

Left Half Indicators, Off Test 1 19 

Leave Floating Trap Mode ... X * 

Logical Left Shift X 52 

Logical Right Shift X 55 

Long Left Shift X 52 

Left Half Indicators, On Test 1 19 

Long Right Shift X 55 

Leave Storage 

Nullification Mode X * 

Leave Trapping Mode X 97 

Load Index from Address 1 26 

Load Index from Decrement 128 

Multiply and Round XX 63 

Multiply XX 60 

Minus Sense X 104 

No Operation 1 07 

Storage Not-Zero Test X X 99 

OR Accumulator to Indica- 
tors ,, 6 

Off Test for Indicators XX 119 

On Test for Indicators XX ng 

OR to Accumulator XX 128 

OR to Storage XX , 2 s 

OR Storage to Indicators XX 1 n 

Place Complement of Address 

in XR 123 

Place Accumulator in Indica- 
tors 1 14 

Place Address in XR 123 

P-bit Test X 99 

Place Complement of Decre- 
ment in XR 123 

Place Decrement in Index 123 

Place Indicator in Accumula- 
tor ^ 114 

Plus Sense ... X 102 

Place Index in Address 1 23 

Place Index in Decrement ... 126 

Reset and Load Channel A. .. XX * 

Reset and Load Channel B ... XX * 

Reset and Load Channel C ... XX * 

Reset and Load Channel D. .. XX * 

Reset and Load Channel E. .. XX * 

Reset and Load Channel F. .. XX * 

Reset and Load Channel G. .. XX * 

Reset and Load Channel H. .. XX * 

Restore Channel Traps X * 

Reset Data Channel A...: * 

Reset Data Channel B * 

Reset Data Channel C. * 

Reset Data Channel D * 

Reset Data Channel E * 

Reset Data Channel F * 

Reset Data Channel G * 

Reset Data Channel H * 

Read Select X * 

Rewind X * 

Right Half Indicators, Off 

Test 119 

Reset Indicators from Accu- 
mulator 116 

Reset Indicators of Left Half 1 14 
Reset Indicators of Right 

Half 114 

Reset Indicators from Storage X X 1 1 1 

Round X 68 

Right Half Indicators, On 

Test 119 

Rotate MQ Left X 55 



* Description not included in text. 



183 



W 



OPERATION CODE 
ALPHA OCTAL 



INSTRUCTION 



S o 
§2 



w 

o 

„ < 

< 6" 



RUN 


077^ 




(\A(\(\ 


SCHA 


0640 


SCHB 




SCHC 


f\£ZA 1 

Ut)41 


SCHD 


UOll 


SCHE 




SCHF 


— 0642 


SCHG 


0643 


SCHH 


—0643 


SDN 


0776 


SIL 


— 0055 


SIR 


0055 


SLQ 


—0620 


SLW 


0602 


SSM 


—0760. 


SSP 


0760. 


STA 


0621 


STD 


0622 


STI 


0604 


STL 


—0625 


STO 


0601 


STP 


0630 


STQ 


—0600 


STR 


1000 


STT 


0625 


CT7 

o 1 L 


uouu 


SUB 


0402 


SXA 


0634 


SXD 


—0634 


TCNA 


—0060 


TCNB 


—0061 


TCNC 


—0062 


TCND 


—0063 


TCNE 


—0064 


TCNF 


—0065 


TCNG 


— 0066* 


TCNH 


—0067* 


TCOA 


0060 


TCOB 


0061 


TCOC 


0062 


TCOD 


0063 


TCOE 


0064 


TCOF 


0065 


TCOG 


0066 


TCOH 


0067 


TEFA 


0030 


TEFB 


—0030 


TEFC 


0031 



Rewind and Unload X * 

Subtract Magnitude X X 60 

Store Channel A x x * 

Store Channel B X X 

Store Channel C XX * 

Store Channel D XX * 

Store Channel E XX * 

Store Channel F XX * 

Store Channel G X X 

Store Channel H XX * 

Set Density * 

Set Indicator of Left Half 1 14 

Set Indicator of Right Half 1 1 1 

Store Left Half MQ X X 5° 

Store Logical Word X X 47 

Set Sign Minus X 1 1 1 

Set Sign Plus X 107 

Store Address X X 50 

Store Decrement X X 50 

Store Indicators X X 1,1 

Store Instruction Location 

Counter XX 50 

Store X X 47 

Store Prefix XX 47 

Store MQ X X 47 

Store Location and Trap 97 

Store Tag XX 50 

Store Zero XX 47 

Subtract „ X X 60 

Store Index in Address 126 

Store Index in Decrement ... 126 
Transfer on DSC A 

Not in Operation XX 94 

Transfer on DSC B 

Not in Operation X X 94 

Transfer on DSC C 

Not in Operation X X 94 

Transfer on DSC D 

Not in Operation X X 94 

Transfer on DSC E 

Not in Operation X X 94 

Transfer on DSC F 

Not in Operation XX 94 

Transfer on DSC G 

Not in Operation X X 94 

Transfer on DSC H 

Not in Operation X X 94 

Transfer on DSC A 

in Operation X X 94 

Transfer on DSC B 

in Operation X X 94 

Transfer on DSC C 

in Operation X X 94 

Transfer on DSC D 

in Operation X X 94 

Transfer on DSC E 

in Operation X X 94 

Transfer on DSC F 

in Operation X X 94 

Transfer on DSC G 

in Operation X X 94 

Transfer on DSC H 

in Operation XX 94 

Transfer on DSC A 

End of File XX 97 

Transfer on DSC B 

End of File X X 97 

Transfer on DSC C 

End of File X X 97 



OPERATION CODE 
ALPHA OCTAL 

TEFD —0031 

TEFE 0032 

TEFF —0032 

TEFG 0033 

TEFH —0033 



INSTRUCTION 



W 

S ii 

§ §1 



TIF 

TIO 

TIX 

TLQ 

TMI 

TNO 

TNX 

TNZ 

TOV 

TPL 

TQO 

TQP 
TRA 
TRCA 

TRCB 

TRCC 

TRCD 

TRCE 

TRCF 

TRCG 

TRCH 

TSX 
TTR 
TXH 
TXI 

TXL 

TZE 
UAM 

UFA 
UFM 

UFS 

USM 

VDH 

VDP 

VLM 
WEF 
WRS 
XCA 
XCL 

XEC 
ZET 



0046 
0042 
2000 
0040 
-0120 
-0140 
-2000 
-0100 
0140 
0120 
0161 

0162 
0020 
0022 

-0022 
0024 

-0224 
0026 

-0026 
0027 

-0027 

0074 
0021 
3000 
1000 

-3000 

0100 
-0304 

-0300 
-0260 

-0302 

-0306 

0224 

0225 

0204 
0770 
0766 
0131 
-0130 

0522 
0520 



Transfer on DSC D 

End of File X X 97 

Transfer on DSC E 

End of File XX 97 

Transfer on DSC F 

End of File XX 97 

Transfer on DSC G 

End of File XX 97 

Transfer on DSC H 

End of File XX 97 

Transfer if Indicators Off XX 1 16 

Transfer if Indicators On XX 1 16 

Transfer on Index 121 

Transfer on Low MQ XX 94 

Transfer on Minus XX 92 

Transfer on No Overflow XX 92 

Transfer on No Index 121 

Transfer on No Zero XX 94 

Transfer on Overflow XX 92 

Transfer on Plus X X 92 

Transfer on Quotient 

Overflow XX 92 

Transfer on MQ Plus XX 92 

Transfer XX 92 

Transfer on DSC A 

Redundancy Check XX 97 

Transfer on DSC B 

Redundancy Check XX 97 

Transfer on DSC C 

Redundancy Check X X 97 

Transfer on DSC D 

Redundancy Check XX 97 

Transfer on DSC E 

Redundancy Check XX 97 

Transfer on DSC F 

Redundancy Check XX 97 

Transfer on DSC G 

Redundancy Check XX 97 

Transfer on DSC H 

Redundancy Check XX 97 

Transfer and Set Index 123 

Trap Transfer X X 97 

Transfer on Index High 121 

Transfer with XR Incre- 
mented 121 

Transfer on XR Low or 

Equal 123 

Transfer on Zero X X 92 

Unnormalized Add Magni- 
tude X X 79 

Unnormalized Floating Add XX 78 
Unnormalized Floating Mul- 
tiply X X 85 

Unnormalized Floating Sub- 
tract XX 79 

Unnormalized Subtract 

Magnitude XX 79 

Variable Length Divide or 

Halt X 67 

Variable Length Divide or 

Proceed X 68 

Variable Length Multiply X 63 

Write End of File X * 

Write Select X * 

Exchange AC and MQ 50 

Exchange Logical AC and 

MQ 50 

Execute X X 107 

Storage Zero Test XX 99 



* Description not included in text. 



184 



APPENDIX B 



SYSTEMS REFERENCES 



Operation 

Code Systems 

ACL 02.10.02.1 

ADD 02.09.91.1 

ADM 02.09.95.1 

ALS 02.09.70.1 

ANA 02.09.46.1 

ANS 02.09.46.1 

ARS 02.09.70.1 

AXC 02.15.62.1 

A XT 02.15.62.1 

BSF 06.01.12.1 

BSR 06.01.12.1 

BTT 02.10.80.1 

CAL 02.10.02.1 

CAQ 02.09.49.1 

CAS 02.09.43.1 

CHS 02.09.57.1 

CLA 02.10.02.1 

CLM 02.09.57.1 

CLS 02.10.02.1 

COM 02.09.57.1 

CRQ 02.09.49.1 

CVR 02.09.49.1 

DCT 02.09.58.1 

DVH 02.09.50.1 

DVP 02.09.50.1 

ECTM 02.10.70.1 

EFTM 02.10.71.1 

ENB 02.10.61.1 

ENK 04.20.14.1 

ERA 02.09.40.1 

ESNT 02.10.70.1 
ESTM 02.10.70.1 
ETM 02.10.53.1 
ETT 02.10.80.1 
FAD 02.10.30.1 
FAM 02.09.95.1 

FDH 02.10.40.1 
FDP 02.10.40.1 
FMP 02.10.23.1 
FRN 02.10.27.1 
FSB 02.09.95.1 
FSM 02.09.95.1 

HPR 03.01.06.1 
HTR 03.01.06.1 
IIA 02.12.67.1 
HX 02.12.61.1 
IIR 02.12.61.1 
IIS 02.12.61.1 

IOT 02.09.58.1 
LAC 02.12.70.1 
LAS 02.09,43.1 
LBT 02.09.58.1 
LCHA 06.00.05.1 
LCHB 06.00.05.1 
LCHC 06.00,06.1 



Operation 

Code Systems 



LCHD 


06. 


. 00. 


, 06. 


, 1 


LCHE 


06. 00. 


, 06. 


, 1 


LCHF 


06. 00. 


,06. 


, 1 


LCHG 


06.00. 


, 07, 


, 1 


LCHH 


06. 00, 


, 07. 


1 


LDC 


02 . 12 . 


, 16. 


1 


LDI 


02. 


, 12. 


, 68. 


1 


LDQ 


02. 


, 12. 


40. 


1 


LFT 


02. 


12. 


67. 


1 


LFTM 


02. 


10. 


71. 


1 


LGL 


02. 


09. 


70. 


1 


LGR 


02. 


09. 


70. 


1 


LLS 


02. 


09. 


70. 


1 


LNT 


02. 


12. 


68. 


1 


LRS 


02. 


09. 


70. 


1 


-LSNM 


02. 


10. 


70. 


1 


LTM 


02. 


10. 


53. 


1 


LXA 


02. 


12. 


70. 


1 


LXD 


02. 


12. 


16. 


1 


MPR 


02. 


09. 


53. 


1 


MPY 


02. 


09. 


53. 


1 


MSE 


02. 


09. 


58. 


1 


NOP 


08. 00. 


01. 


1 


NZT 


02. 


11. 


50. 


1 


OAI 


02. 


12. 


67. 


1 


OFT 


02. 


12. 


68. 


1 


ONT 


02. 12. 


68. 


1 


ORA 


02. 


10. 


02. 


1 


ORS 


02. 


09. 


00. 


1 


OSI 


02. 


12. 


68. 


1 


PAC 


02. 


12. 


70. 


1 


PAI 


02. 


12. 


67. 


1 


PAX 


02. 


12. 


70. 


1 


PBT 


02. 


09. 


58. 


1 


PDC 


02. 


12. 


70. 


1 


PDX 


02. 


12. 


16. 


1 


PIA 


02. 


12. 


67. 


1 


PSE 


02. 


09. 


58. 


1 


PXA 


02. 


12. 


70. 


1 


PXD 


02. 


12. 


70. 


1 


RCHA 


06. 


00. 


05. 


1 


RCHB 


06. 


00. 


05. 


1 


RCHC 


06. 


00. 


06. 


1 


RCHD 


06. 


00. 


06. 


1 


RCHE 


06. 


00. 


06. 


1 


RCHF 


06. 


00. 


06. 


1 


RCHG 


06. 00. 


07. 


1 


RCHH 


06. 00. 


07. 


1 


RCT 


02. 


10. 


61. 


1 


RDCA 


60.65. 


04. 


1 


RDCB 


60.65. 


04. 


1 


RDCC 


60.65. 


04. 


1 


RDCD 


60.65. 


04. 


1 


RDCE 


60.65. 


04. 


1 



Operation 

Code Systems 



RDCF 


60. 


65. 


04. 


1 


RDCG 


60. 


65. 


04. 


1 


RDCH 


60. 


65. 


04. 


1 


RDS 


06. 


01. 


12. 


1 


REW 


06. 


01. 


12. 


2 


RFT 


02. 


, 12. 


67. 


1 


RIA 


02. 


12. 


67. 


, 1 


RIL 


02. 


12. 


62. 


1 


RIR 


02. 


12. 


62. 


1 


RIS 


02. 


12. 


62. 


, 1 


RND 


02. 


09. 


57. 


1 


RNT 


02. 


12. 


58. 


1 


RQL 


02. 


09. 


70. 


1 


RUN 










SBM 


02. 


09. 


95. 


1 


SCHA 


06. 


00. 


05. 


1 


SCHB 


06. 


00. 


05. 


1 


SCHC 


06. 


00. 


06. 


1 


SCHD 


06. 


00. 


06. 


1 


SCHE 


06. 


00. 


06. 


1 


SCHF 


06. 


00. 


06. 


1 


SCHG 


06. 


00. 


07. 


1 


SCHH 


06. 


00. 


07. 


1 


SDN 


60. 


50. 


02. 


3 


SIL 


02. 


12. 


63. 


1 


SIR 


02. 


12. 


63. 


1 


SLQ 


02. 


09. 


00. 


1 


SLW 


02. 


09. 


00. 


1 


SSM 


02. 


09. 


57. 


1 


SSP 


02. 


09. 


57. 


1 


STA 


02. 


09. 


01. 


1 


STD 


02. 


09. 


01. 


1 


STI 


02. 


09. 


00. 


1 


STL 


02. 


09. 


01. 


1 


STO 


02. 


09. 


00. 


1 


STP 


02. 


09. 


01. 


1 


STQ 


02. 


09. 


00. 


1 


STR 


02. 


09. 


00. 


1 


STT 


02. 


09. 


01. 


1 


STZ 


02. 


09. 


00. 


1 


SUB 


02. 


09. 


95. 


1 


SXA 


02. 


09. 


01. 


1 


SXD 


02. 


09. 


01. 


1 


TCNA 


06. 


01. 


00. 


1 


TCNB 


06. 


01. 


00. 


1 


TCNC 


06. 


01. 


01. 


1 


TCND 


06. 


01. 


01. 


1 


TCNE 


06. 


01. 


02. 


1 


TCNF 


06. 


01. 


02. 


1 


TCNG 


06. 


01. 


03. 


1 


TCNH 


06. 


01. 


03. 


1 


TCOA 


06. 


01. 


00. 


1 


TCOB 


06. 


01. 


00. 


1 


TCOC 


06. 


01. 


01. 


1 



Operation 

Code Systems 

TCOD 06.01.01.1 

TCOE 06.01.02.1 

TCOF 06.01.02.1 

TCOG 06.01.03.1 

TCOH 06.01.03.1 

TEFA 06.01.00.1 

TEFB 06.01.00.1 

TEFC 06.01.01.1 

TEFD 06.01.01.1 

TEFE 06.01,02.1 

TEFF 06.01.02.1 

TEFG 06.01.03.1 

TEFH 06.01.03.1 

TIF 02.10.57.1 

TIO 02.10.57.1 

TIX 02.15.62.1 

TLQ 02.09.30.1 

TMI 02.10.08.1 

TNO 02.10.08.1 

TNX 02 . 15 . 62 . 1 

TNZ 02.09.30.1 

TOV 02.10.08.1 

TPL 02.10.08.1 

TQO 02.10.08.1 

TQP 02.10.08.1 

TRA 02.10.08.1 

TRCA 06.01.00.1 

TRCB 06.01.00.1 

TRCC 06.01.01.1 

TRCD 06.01.01.1 

TRCE 06.01.02.1 

TRCF 06.01.02.1 

TRCG 06.01.03.1 

TRCH 06.01.03.1 

TSX 02.15.62.1 

TTR 02.10.08.1 

TXH 02.15.62.1 

TXI 02.15.62.1 

TXL 02.15.62.1 

TZE 02.09.30.1 

UAM 02.09.95.1 

UFA 03.01.10.1 

UFM 02.10.24.1 

UFS 02.09.95.1 

USM 02.09.95.1 

VDH 02.09.50.1 

VDP 02.09.50.1 

VLM 02.09.53.1 

WEF 06.01.12.2 

WRS 06.01.12.2 

XCA 02.10.06.1 

XCL 02.10.06.1 

XEC 03.06.05.1 

ZET 02.11.50.1 



185 



COMMENT SHEET 
IBM 7090 (7100, 7151, 7606) 

CUSTOMER ENGINEERING I NSTR UCT ION- R EF ER E NC E , FORM 223—6895-1 

FROM 

NAM E 

OFFICE NO. 

CHECK ONE OF THE COMMENTS AND EXPLAIN IN THE SPACE PROVIDED 

SUGGESTED ADDITION (PAGE , TIMING CHART, DRAWING, PROCEDURE, ETC.) 

CD SUGGESTED DELETION (PAGE ) 
□ ER R OR (PAGE ) 