KN210 CPU Module Set 
Technical Manual 

Order Number EK-KN210-TM-001 



digital equipment corporation 
maynard, massachusetts 



First Edition, June 1989 

The information in this document is subject to change without notice and should not 
be construed as a commitment by Digital Equipment Corporation. Digital Equipment 
Corporation assumes no responsibility for any errors that may appear in this document. 

The software described in this document is furnished under a license and may be used or 
copied only in accordance with the terms of such license. 

No responsibility is assumed for the use or reliability of software on equipment that is not 
supplied by Digital Equipment Corporation or its affiliated companies. 

Copyright © by Digital Equipment Corporation 1989 

All Rights Reserved. 
Printed in U.SA. 



The following are trademarks of Digital Equipment Corporation: 



DEC 


MicroVAX 3400 


RT 


DECmate 


MicroVAX 3500 


ThinWire 


DECUS 


MicroVAX 3600 


UNIBUS 


DECwriter 


PDP 


VAX 


DIBOL 


P/OS 


VAXstation 


LSI-11 


Professional 


VMS 


MASSBUS 


Q-bus 


VT 


MicroPDP-11 


Q22-bus 


VT100 


MicroVAX 


Rainbow 


Work Processor 


MicroVAX I 


RSTS 




MicroVAX II 


RSX 


HMMMHMH™ 



FCC NOTICE: The equipment described in this manual generates, uses, and may emit 
radio frequency energy. The equipment has been type tested and found to comply with 
the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC 
Rules, which are designed to provide reasonable protection against such radio frequency 
interference when operated in a commercial environment. Operation of this equipment in 
a residential area may cause interference, in which case the user at his own expense may 
be required to take measures to correct the interference. 



Contents 



About This Manual xxi 

1 Overview 

1.1 Introduction 1—1 

1.2 R3000 RISC Processor 1^4 

1.3 Floating-Point Accelerator 1-5 

1.4 Cache Memory 1—5 

1.5 Memory Controller 1—5 

1.6 Diagnostic Processor 1—5 

1.7 MS650-BA Memory Modules 1-5 

1.8 MS650-AA Memory Modules 1-6 

1.9 DSSI Interface 1-6 

1.10 Ethernet Interface 1-7 

1.11 Q22-bus Interface 1-7 

1.12 System Support Functions 1—7 

1.13 Firmware 1-8 

1.14 Clock Functions 1-8 

2 Installation and Configuration 

2.1 Introduction 2—1 

2.2 Installing the KN210 CPU Module Set 2-1 

2.3 Configuring the KN210 2-3 

2.4 KN210 Connectors 2-4 

2.4.1 Console/Ethernet Connector 2—5 

2.4.2 DSSI/I/O Connector 2-7 

2.4.3 Memory Connector 2—9 

Hi 



iv Contents 

2.5 H3602-SA CPU Cover Panel 2-11 

3 Architecture 

3.1 R3000 RISC Processor 3-1 

3.1.1 Processor Features 3-2 

3.1.1.1 General Purpose Registers 3—2 

3.1.1.2 Instruction Set 3-3 

3.1.2 Coprocessors 3-6 

3.1.2.1 Coprocessor (0) 3-6 

3.1.2.2 Coprocessor (1) 3-6 

3.1.3 Memory Management 3-6 

3.1.3.1 Operating Modes 3-9 

3.1.3.2 EntryHi and EntryLo Registers 3-9 

3.1.3.3 Index Register 3-11 

3.1.3.4 Random Register 3-11 

3.1.4 Exception Handling Registers 3-12 

3.1.4.1 Cause Register 3-12 

3.1.4.2 Exception Program Counter 3—15 

3.1.4.3 Status Register 3-15 

3.1.4.4 BadVaddr Register 3-16 

3.1.4.5 Context Register 3-16 

3.1.4.6 Processor Revision Identifier Register 3-17 

3.1.4.7 Interrupt Status Register 3-17 

3.1.4.8 Vector Read Registers 3-18 

3.1.5 Exceptions 3-21 

3.1.5.1 General Exception Vector 3—21 

3.1.5.2 Reset Exception Vector 3-21 

3.2 Floating-Point Accelerator 3-22 

3.2.1 Floating-Point Accelerator Instructions 3—22 

3.3 Cache Memory 3-23 

3.3.1 Cache Organization 3-23 

3.3.2 Cache Isolation 3-23 

3.3.3 Cache Swapping . 3-23 

3.3.4 Cache Line Format 3-23 

3.4 Main Memory System 3-24 



Contents v 

3.4.1 Main Memory Organization 3—27 

3.4.2 Main Memory Addressing 3—27 

3.4.3 Main Memory Behavior on Writes 3-28 

3.4.4 Main Memory Error Status Register 3—28 

3.4.5 Main Memory Control and Diagnostic Status Register . . 3-32 

3.4.6 Main Memory Error Detection and Correction 3-34 

3.5 Console Serial Line 3—36 

3.5.1 Console Registers 3-36 

3.5.1.1 Console Receiver Control/Status Register 3-37 

3.5.1.2 Console Receiver Data Buffer 3-37 

3.5.1.3 Console Transmitter Control/Status Register 3-39 

3.5.1.4 Console Transmitter Data Buffer 3-40 

3.5.2 Break Response 3-41 

3.5.3 Baud Rate 3-41 

3.5.4 Console Interrupt Specifications 3—42 

3.6 Time-of-Year Clock and Timers 3-42 

3.6.1 R3000 Interval Timer Register 3-42 

3.6.2 Time-of-Year Clock 3-43 

3.6.3 Interval Timer 3-44 

3.6.4 Programmable Timers 3-45 

3.6.4.1 Timer Control Registers 3-45 

3.6.4.2 Timer Interval Registers 3-47 

3.6.4.3 Timer Next Interval Registers 3-48 

3.6.4.4 Timer Interrupt Vector Registers 3-48 

3.7 Boot and Diagnostic Facility 3-49 

3.7.1 Boot and Diagnostic Register 3—49 

3.7.2 Diagnostic LED Register 3-51 

3.7.3 ROM Memory 3-52 

3.7.3.1 ROM Socket 3-52 

3.7.3.2 ROM Address Space 3-52 

3.7.4 Battery Backed-Up RAM 3-53 

3.7.5 KN210 Initialization 3-53 

3.7.5.1 Power-Up Initialization 3-53 

3.7.5.2 Hardware Reset 3-53 

3.7.5.3 I/O Bus Initialization 3-53 

3.7.5.4 Processor Initialization 3—54 



vi Contents 



3.7.6 Select Processor Register 3-54 

3.7.7 Write Error Address Register 3-55 

3.8 Q22-bus Interface 3-55 

3.8.1 Q22-bus to Main Memory Address Translation 3-56 

3.8.1.1 Q22-bus Map Registers 3-58 

3.8.1.2 Accessing the Q22-bus Map Registers 3-59 

3.8.1.3 Q22-bus Map Cache 3-60 

3.8.2 CDAL Bus to Q22-bus Address Translation 3-62 

3.8.3 Interprocessor Communication Register 3—62 

3.8.4 Q22-bus Interrupt Handling 3-63 

3.8.5 Configuring the Q22-bus Map 3-64 

3.8.5.1 Q22-bus Map Base Address Register 3-64 

3.8.6 System Configuration Register 3-65 

3.8.7 DMA System Error Register 3-66 

3.8.8 Q22-bus Error Address Register 3-69 

3.8.9 DMA Error Address Register 3-69 

3.8.10 Error Handling 3-70 

3.9 Network Interface 3-72 

3.9.1 Ethernet Overview 3-72 

3.9.2 Network Interface Station Address ROM 3-74 

3.9.3 LANCE Chip Overview 3-75 

3.9.4 Network Interface Register Address Port 3-77 

3.9.5 Network Interface Register Data Port 3-78 

3.9.6 Network Interface Control and Status Register 3-78 

3.9.7 Network Interface Control and Status Register 1 3-84 

3.9.8 Network Interface Control and Status Register 2 3-84 

3.9.9 Network Interface Control and Status Register 3 3-85 

3.9.10 Network Interface Initialization Block 3—86 

3.9.10.1 Network Interface Initialization Block Word 3-87 

3.9.10.2 Network Interface Initialization Block Words 1-3 3-90 

3.9.10.3 Network Interface Initialization Block Words 4-7 3-91 

3.9.10.4 Network Interface Initialization Block Words 8,9 3-92 

3.9.10.5 Network Interface Initialization Block Words 10,11 . . . 3-94 

3.9.11 Buffer Management 3-95 

3.9.12 Network Interface Receive Descriptor Ring 3-96 

3.9.12.1 Receive Buffer Descriptors 3-97 



Contents vii 



3.9.13 Receive Buffers 3-102 

3.9.14 Network Interface Transmit Descriptor Ring 3—103 

3.9.14.1 Transmit Buffer Descriptors 3-104 

3.9.15 Transmit Buffers 3-109 

3.9.16 LANCE Operation 3-109 

3.9.16.1 Switch Routine 3-110 

3.9.16.2 Initialization Routine 3-110 

3.9.16.3 Look-For-Work Routine 3-111 

3.9.16.4 Receive Poll Routine 3-111 

3.9.16.5 Receive Routine 3-111 

3.9.16.6 Receive DMA Routine 3-112 

3.9.16.7 Transmit Poll Routine 3-112 

3.9.16.8 Transmit Routine 3-113 

3.9.16.9 Transmit DMA Routine 3-113 

3.9.16.10 Collision Detect Routine 3-114 

3.9.17 LANCE Programming Notes 3-114 

3.10 Mass Storage Interface 3-117 

3.10.1 DSSI Bus Overview 3-117 

3.10.2 Target Operation 3-119 

3.10.3 Initiator Operation 3-121 

3.10.3.1 Transmit Data Segment Links 3-121 

3.10.4 Adding to a Buffer List 3-122 

3.10.5 Mass Storage Interface Command Block (MSICB) 3-124 

3.10.5.1 MSI Command Block Word 3-124 

3.10.5.2 MSI Command Block Word 1 3-125 

3.10.5.3 MSI Command Block Word 2 3-127 

3.10.5.4 MSI Command Block Words 3-5 3-128 

3.10.6 MSI Registers 3-128 

3.10.6.1 MSI Control and Status Registers 3-128 

3.10.6.2 List Pointer Registers 3-138 

3.10.6.3 Diagnostic and Test Registers 3-139 



viii Contents 



4 KN210 Firmware 

4.1 Firmware Capabilities 4—2 

4.2 Power-Up 4-2 

4.2.1 Initial Power-Up Test 4-2 

4.2.2 Locating a Console Device 4—3 

4.2.3 Operation and Function Switches 4-3 

4.2.3.1 Operation Switch Set to Normal 4—4 

4.2.3.2 Operation Switch Set to Maintenance 4—5 

4.2.3.3 Operation Switch Set to Action 4—6 

4.2.3.4 LED Codes 4-7 

4.2.4 Interprocessor Interaction 4-8 

4.2.4.1 Select Processor Register Operation 4—9 

4.2.5 Power-Up Sequence 4—9 

4.2.5.1 Normal Power-Up Operation 4—9 

4.2.5.2 Maintenance Power-Up Operation 4—10 

4.2.6 Processor Identification 4—10 

4.2.6.1 SysJIype Register Layout 4-10 

4.3 Operating System Bootstrap 4—11 

4.3.1 MDM Bootstrap 4-11 

4.3.2 Operating System Bootstrap 4—12 

4.3.3 Boot Process 4-13 

4.3.4 Bootstrap Support Routines in the Console 4—14 

4.3.5 Console Use of Memory Space 4—14 

4.3.6 Boot Devices 4—15 

4.3.6.1 Disk 4-15 

4.3.6.2 Tape 4-15 

4.3.6.3 Ethernet 4-15 

4.3.7 Halts 4-16 

4.4 KN210 Console Command Language 4—17 

4.4.1 Maintenance Mode Console Command Language 4—17 

4.4.2 Normal Mode Console Command Language 4—17 

4.4.2.1 Control Characters 4-17 

4.4.2.2 Lexical Conventions 4—18 

4.4.2.3 Environment Variables 4—19 

4.4.2.4 Commands 4-20 

4.5 Diagnostics 4—23 



Contents ix 



4.6 PROM Entry Points 4-23 

4.6.1 Argvize 4-23 

4.6.2 Atob 4-23 

4.6.3 Autoboot 4-24 

4.6.4 Bevexcept 4—24 

4.6.5 Bevutlb 4-24 

4.6.6 Close 4-24 

4.6.7 Dumpcmd 4-24 

4.6.8 Exec 4-25 

4.6.9 Getchar 4-25 

4.6.10 Getenv 4-25 

4.6.11 Gets 4-25 

4.6.12 Halt 4-25 

4.6.13 Help 4-25 

4.6.14 Ioctl 4-26 

4.6.15 Longjump 4—26 

4.6.16 Lseek 4-26 

4.6.17 Open 4-26 

4.6.18 Parser 4-27 

4.6.19 Printenvcmd 4-27 

4.6.20 Printf 4-27 

4.6.21 Putchar 4-27 

4.6.22 Puts 4-28 

4.6.23 Range 4-28 

4.6.24 Read 4-28 

4.6.25 Reboot 4-28 

4.6.26 Remit 4-29 

4.6.27 Reset 4-29 

4.6.28 Restart 4-29 

4.6.29 Setenv 4-29 

4.6.30 Setenvcmd 4-29 

4.6.31 Setjmp 4-30 

4.6.32 Showchar 4-30 

4.6.33 Strcat 4-30 

4.6.34 Strcmp 4-30 

4.6.35 Strcpy 4-31 



x Contents 



4.6.36 Strlen 4-31 

4.6.37 Unsetenvcmd , 4-31 

4.6.38 Write 4-31 

4.7 Supported Devices 4-32 

5 Diagnostic Processor 

5.1 Diagnostic Processor 5—1 

5.1.1 Processor State 5—1 

5.1.1.1 General Purpose Registers 5-1 

5.1.1.2 Processor Status Longword 5-2 

5.1.1.3 Internal Processor Registers 5—4 

5.1.2 Data Types . 5-8 

5.1.3 Instruction Set 5-8 

5.1.4 Memory Management 5—9 

5.1.4.1 Translation Buffer 5-9 

5.1.4.2 Memory Management Control Registers 5—10 

5.1.5 Exceptions and Interrupts 5-11 

5.1.5.1 Interrupts 5-11 

5.1.5.2 Exceptions 5-13 

5.1.5.3 Information Saved on a Machine Check Exception . . . 5—16 

5.1.5.4 System Control Block 5-21 

5.1.5.5 Diagnostic Processor Hardware Detected Errors 5—24 

5.1.5.6 Hardware Halt Procedure 5—25 

5.1.6 System Identification 5—27 

5.1.7 CVAX References 5-28 

5.1.7.1 Instruction-Stream Read References 5—28 

5.1.7.2 Data-Stream Read References 5-29 

5.1.7.3 Write References 5-29 



Contents xi 

6 Maintenance Mode Firmware 

6.1 Maintenance Mode Firmware Features 6—1 

6.1.1 Halt Entry, Exit, and Dispatch 6-2 

6.1.1.1 Halt Entry - Saving Processor State 6-2 

6.1.1.2 Halt Exit - Restoring Processor State 6-3 

6.1.1.3 Halt Dispatch 6-5 

6.1.1.4 External Halts 6-4 

6.1.2 Power-Up 6-5 

6.1.2.1 Initial Power-Up Test 6-5 

6.1.2.2 Locating a Console Device 6—5 

6.1.3 Mode Switch Set to "Test" 6-6 

6.1.4 Mode Switch Set to "Query" 6-7 

6.1.5 Mode Switch Set to "Normal" 6-8 

6.1.6 LED Codes 6-9 

6.2 Console Service 6—9 

6.2.1 Console Control Characters 6-10 

6.2.2 Console Command Syntax 6-12 

6.2.3 Console Command Keywords 6-12 

6.2.4 Console Command Qualifiers 6-14 

6.2.5 Command Address Specifiers 6-14 

6.2.6 References to Processor Registers and Memory 6-17 

6.2.7 Console Commands 6-18 

6.2.7.1 BOOT 6-18 

6.2.7.2 CONFIGURE 6-20 

6.2.7.3 CONTINUE 6-22 

6.2.7.4 DEPOSIT 6-22 

6.2.7.5 EXAMINE 6-24 

6.2.7.6 EXIT 6-27 

6.2.7.7 FIND 6-28 

6.2.7.8 HALT 6-29 

6.2.7.9 HELP 6-29 

6.2.7.10 INITIALIZE 6-31 

6.2.7.11 MOVE 6-33 

6.2.7.12 NEXT 6-35 

6.2.7.13 REPEAT 6-36 

6.2.7.14 SEARCH 6-37 



xii Contents 



6.2.7.15 SET 6-40 

6.2.7.16 SHOW 6-^44 

6.2.7.17 START 6-48 

6.2.7.18 TEST 6-^8 

6.2.7.19 UNJAM 6-52 

6.2.7.20 X - Binary Load and Unload 6-52 

6.2.7.21 ! - Comment 6-54 

6.2.8 Conventions for Tables 6—5 and 6-6 6—55 

6.3 Bootstrapping 6-58 

6.3.1 Boot Devices 6-58 

6.3.2 Boot Flags 6-60 

6.3.3 Preparing for the Bootstrap 6-62 

6.3.4 Primary Bootstrap, VMB 6-63 

6.3.5 Device Dependent Bootstrap Procedures 6-66 

6.3.5.1 Disk and Tape Bootstrap Procedure 6—66 

6.3.5.2 PROM Bootstrap Procedure 6-67 

6.3.5.3 Network Bootstrap Procedure 6-68 

6.3.5.4 Network Listening 6-69 

6.4 Diagnostics 6-71 

6.4.1 Error Reporting 6-73 

6.4.2 Diagnostic Interdependencies 6-74 

6.4.3 Areas Not Covered 6-75 

6.5 Operating System Restart 6—75 

6.5.1 Locating the RPB 6-76 

6.6 Machine State on Power-Up 6-77 

6.6.1 Main Memory Layout and State 6-77 

6.6.1.1 Reserved Main Memory 6-78 

6.6.1.2 PFN Bitmap 6-78 

6.6.1.3 Scatter/Gather Map 6-79 

6.6.1.4 Contents of Main Memory 6-79 

6.6.2 CMCTL Registers 6-79 

6.6.3 First Level Cache 6-80 

6.6.4 Translation Buffer 6-80 

6.6.5 Halt Protected Space 6-80 

6.7 Public Data Structures and Entry Points 6-80 

6.7.1 Maintenance Mode Firmware EPROM Layout 6-80 



Contents xiii 



6.7.2 Call-Back Entry Points 6-82 

6.7.2.1 CP$GETCHAR_R4 6-^82 

6.7.2.2 CP$MSG_OUT_NOLF_R4 6-83 

6.7.2.3 CP$READ_WTH_PRMPT_R4 6-84 

6.7.3 SSC RAM Layout 6-^85 

6.7.4 Public Data Structures 6-85 

6.7.4.1 Console Program Mailbox 6-85 

6.7.4.2 Firmware Stack 6-87 

6.7.4.3 Diagnostic State 6-87 

6.7.4.4 User Area 6-87 

6.8 Error Messages 6-87 

6.8.1 Halt Code Messages 6-88 

6.8.2 Console Error Messages 6-89 

6.8.3 VMB error messages 6-91 

A Specifications 

A.1 Physical Specifications A— 1 

A.2 Electrical Specifications A— 1 

A.3 Environmental Specifications A— 2 

B Address Assignments 

B.l R3000 Physical Address Space Map B-l 

B.2 CVAX Physical Address Space Map B-^4 

B.2.1 External IPRs B-6 

B.3 Global Q22-bus Address Space Map B-7 

C Q22-bus Specification 

C.l Introduction C— 1 

C.l.l Master/Slave Relationship C— 2 

C.2 Q22-bus Signal Assignments C— 3 

C.3 Data Transfer Bus Cycles C-6 

C.3.1 Bus Cycle Protocol C-7 

C.3.2 Device Addressing C-7 

C.4 Direct Memory Access C— 17 



xiv Contents 



C.4.1 DMA Protocol C-17 

C.4.2 Block Mode DMA C-18 

C.4.2.1 DATBI Bus Cycle C-23 

C.4.2.2 DATBO Bus Cycle C-24 

C.4.3 DMA Guidelines C-26 

C.5 Interrupts C-27 

C.5.1 Device Priority C-28 

C.5.2 Interrupt Protocol C-28 

C.5. 3 Q22-bus Four-Level Interrupt Configurations C--32 

C.6 Control Functions C-34 

C.6.1 Halt C-34 

C.6.2 Initialization C-34 

C.6.3 Power Status C-34 

C.7 Q22-bus Electrical Characteristics C-34 

C.7.1 Signal Level Specifications C-35 

C.7.2 Load Definition C-35 

C.7.3 120-Ohm Q22-bus C-35 

C.7.4 Bus Drivers C-36 

C.7.5 Bus Receivers C-36 

C.7.6 Bus Termination C-37 

C.7.7 Bus Interconnecting Wiring C— 38 

C.7.7.1 Backplane Wiring C-38 

C.7.7.2 Intrabackplane Bus Wiring C-39 

C.7.7.3 Power and Ground C-39 

C.8 System Configurations C-39 

C.8.1 Power Supply Loading C-43 

C.9 Module Contact Finger Identification C-43 



D Acronyms 
Index 



Contents xv 

Examples 

4—1 Normal Diagnostic Countdown 4—4 

4—2 Abnormal Diagnostic Countdown 4—5 

4-3 Language Selection Menu 4—7 

4—4 Normal Power-Up Sequence Algorithm 4—9 

4—5 Maintenance Power-Up Sequence Algorithm 4—10 

6-1 Language Selection Menu 6—7 

6—2 Normal Diagnostic Countdown 6—8 

6-3 Abnormal Diagnostic Countdown 6—8 

6-4 Diagnostic Register Dump 6-73 

Figures 

1-1 KN210 Processor Module 1-2 

1-2 KN210 I/O Module 1-3 

1-3 KN210 Block Diagram 1-4 

1-4 MS650 Memory Modules 1-6 

2—1 Processor, I/O and Memory Module Placement 2—2 

2-2 Cable Connections 2-3 

2-3 KN210 Connector and LED Orientation 2-4 

2-4 H3602-SA CPU Cover Panel 2-12 

3—1 Instruction Set Types 3-3 

3-2 R3000 Virtual to Physical Memory Map 3-7 

3-3 R3000 to I/O Memory Map 3-8 

3-4 TLB EntryHi Register 3-9 

3-5 TLB EntryLo Register 3-10 

3-6 Index Register 3-11 

3-7 Random Register 3-11 

3-8 Cause Register 3-12 

3—9 Interrupt Acknowledge Daisy Chain 3—14 

3-10 Status Register 3-15 

3—11 Context Register 3—16 

3—12 Processor Revision Identifier Register 3—17 

3-13 Interrupt Status Register 3—18 

3-14 Vector Read Register 3-19 

3-15 Vector Read Register 1 3-20 



xvi Contents 



3-16 Vector Read Register 2 3-20 

3-17 Vector Read Register 3 3-20 

3-18 Cache Line Format 3-23 

3-19 Tag Field 3-24 

3-20 Format for MEMCSR16 3-28 

3-21 Format for MEMCSR17 3-32 

3—22 Console Receiver Control/Status Register 3—37 

3-23 Console Receiver Data Buffer 3-38 

3-24 Console Transmitter Control/Status Register 3-39 

3-25 Console Transmitter Data Buffer 3-^10 

3-26 Interval Timer Register 3-42 

3-27 Time-of-Year Clock 3-44 

3-28 Interval Timer 3-44 

3-29 Timer Control Registers 3-46 

3—30 Timer Interrupt Vector Register 3—48 

3-31 Boot and Diagnostic Register 3—49 

3-32 Diagnostic LED Register 3-51 

3—33 Select Processor Register 3—54 

3-34 Q22-bus to Main Memory Address Translation 3-57 

3-35 Q22-bus Map Registers 3-58 

3-36 Q22-bus Map Cache Entry 3-61 

3—37 The Interprocessor Communication Register 3-62 

3-38 Q22-bus Map Base Address Register 3-64 

3—39 System Configuration Register 3—65 

3-40 DMA System Error Register 3-67 

3-41 Q22-bus Error Address Register 3-69 

3-42 DMA Error Address Register 3-70 

3-43 Ethernet Data Packet Format 3-73 

3-44 Network Interface Station Address ROM Format 3-75 

3-45 Network Interface Register Address Port 3—77 

3-46 Network Interface Control and Status Register 3—79 

3—47 Network Interface Control and Status Register 1 3—84 

3-48 Network Interface Control and Status Register 2 3-85 

3—49 Network Interface Control and Status Register 3 3—85 

3—50 Network Interface Initialization Block 3—87 

3—51 Network Interface Initialization Block Word 3—88 



Contents xvii 

3-52 Network Interface Initialization Block Words 1-3 3-91 

3—53 Network Interface Initialization Block Words 4-7 3—91 

3—54 Network Interface Initialization Block Word 8 3-92 

3—55 Network Interface Initialization Block Word 9 3—93 

3—56 Network Interface Initialization Block Word 10 3—94 

3—57 Network Interface Initialization Block Word 11 3-94 

3—58 Network Interface Receive Descriptor Ring 3-97 

3—59 Receive Buffer Descriptors 3-98 

3-60 Receive Buffer Descriptor n Word 3-98 

3-61 Receive Buffer Descriptor n Word 1 3-99 

3-62 Receive Buffer Descriptor n Word 2 3-101 

3-63 Receive Buffer Descriptor n Word 3 3-101 

3-64 Receive Buffers 3-102 

3-65 Network Interface Transmit Descriptor Ring 3—103 

3-66 Transmit Buffer Descriptors 3-104 

3-67 Transmit Buffer Descriptor n Word 3-104 

3-68 Transmit Buffer Descriptor n Word 1 3-105 

3-69 Transmit Buffer Descriptor n Word 2 3-106 

3-70 Transmit Buffer Descriptor n Word 3 3-107 

3-71 Transmit Buffers 3-109 

3-72 DSSI Bus Sequences 3-118 

3-73 Target Operation 3-120 

3-74 Transmit Data Segment Links 3-121 

3-75 Initiator Operation 3-123 

3-76 MSI Command Block 3-124 

3-77 MSI Command Block Word 3-124 

3-78 MSI Command Block Word 1 3-125 

3-79 MSI Command Block Word 2 3-127 

3-80 MSI Control/Status Register 3-129 

3-81 MSI DSSI Control Register 3-130 

3-82 MSI DSSI Connection Register 3-132 

3-83 MSI ID Register 3-136 

3-84 MSI DSSI Timeout Register 3-137 

3-85 MSI Target List Pointer Register 3-138 

3-86 MSI Initiator list Pointer Register 3-139 

3-87 MSI Diagnostic Control Register 3-140 



xviii Contents 



3-88 MSI Diagnostic Register 3-141 

3-89 MSI Diagnostic Register 1 3-142 

3-90 MSI Diagnostic Register 2 3-144 

3-91 MSI Clock Control Register 3-145 

4—1 System Type Register 4— 10 

4-2 Bootblock Layout 4-13 

5—1 General Purpose Register Bit Map 5-2 

5-2 PSL Bit Map 5-3 

5—3 Interrupt Registers 5-13 

5—4 Information Saved on a Machine Check Exception 5-16 

5—5 System Control Block Base Register 5—21 

5—6 System Identification Register 5—27 

5-7 System Type Register 5-28 

6-1 VMB Boot Flags 6-61 

6-2 Memory Layout at VMB Exit 6-65 

6-3 Boot Block Format 6-67 

6-4 RPB Signature Format 6-76 

6—5 Memory Layout After Power-Up Diagnostics 6-77 

6-6 KN210 Maintenance Mode EPROM Layout 6-S1 

6-7 KN210 SSC NVRAM Layout 6-85 

&-$ NVRO 6-86 

6-9 NVR1 6-86 

6-10 NVR2 &-87 

C-l DATI Bus Cycle C-9 

C-2 DATI Bus Cycle Timing C-ll 

C-3 DATO or DATOB Bus Cycle C-12 

0-4: DATO or DATOB Bus Cycle Timing C-14 

C-5 DATIO or DATIOB Bus Cycle C-15 

C-6 DATIO or DATIOB Bus Cycle Timing C-16 

C-7 DMA Protocol C-19 

C-8 DMA Request/Grant Timing C-20 

C-9 DATBI Bus Cycle Timing C-21 

C-10 DATBO Bus Cycle Timing C-22 

C-ll Interrupt Request/Acknowledge Sequence C— 29 

C-12 Interrupt Protocol Timing C-31 

C— 13 Position-Independent Configuration C— 33 



Contents xix 



C-14 Position-Dependent Configuration C-33 

C-15 Bus Line Terminations C-37 

C— 16 Single-Backplane Configuration C— 40 

C-17 Multiple Backplane Configuration C-42 

C-18 Typical Pin Identification System C-^43 

C-19 Quad-Height Module Contact Finger Identification C-44 

C-20 Typical Q22-bus Module Dimensions C-45 

Tables 

2—1 Console/Ethernet Connector (Jl) Pinouts 2—5 

2-2 DSSI Connector (I/O Module J2-Upper) Pinouts 2-8 

2-3 I/O Connector (I/O Module J2-Lower) Pinouts 2-9 

2-4 Memory Connector (Processor Module J2-Lower) Pinouts . . 2-10 

2-5 H3602-SA Features and Controls 2-11 

3—1 Instruction Summary 3—3 

3-2 R3000 Interrupt Mapping 3-14 

3-3 CPU Read Reference Timing 3-25 

3-4 CPU Write Reference Timing 3-25 

3—5 Q22-bus Interface Read Reference Timing 3—25 

3-6 Q22-bus Interface Write Reference Timing 3-26 

3-7 Error Syndromes 3-30 

3—8 Console Registers 3-36 

3-9 Baud Rate Select 3-42 

3-10 Q22-bus Map 3-59 

4—1 Operation and Function Switches 4—4 

4-2 LED Codes 4-8 

4—3 Console Memory Space 4—14 

4-4 PROMJHALT Saved Registers 4-16 

4—5 Control Characters 4—17 

4-6 Environment Variables 4—19 

4-7 KN210 Boot Devices 4-32 

5—1 KN210 Internal Processor Registers 5—5 

5-2 VAX Standard IPRs 5-7 

5-3 KN210 Unique IPRs 5-8 

5—4 Interrupts 5—11 

5-5 Exceptions 5—15 



xx Contents 

5-6 System Control Block Format 5-22 

5—7 Unmaskable Interrupts That can Cause a Halt 5-26 

5—8 Exceptions That can Cause a Halt 5-26 

6-1 Halt Action Summary 6—4 

6-2 LED Codes 6-9 

6-3 Command, Parameter, and Qualifier Keywords 6-13 

6-4 Console Symbolic Addresses 6-14 

6—5 Console Command Summary 6-55 

6—6 Console Qualifier Summary 6-57 

6-7 KN210 Supported Boot Devices 6-59 

6-8 VMB Boot Flags 6-61 

6—9 KN210 Network Maintenance Operations Summary 6-70 

6-10 HALT Messages 6-88 

6-11 Console Error Messages 6-89 

6-12 VMB Error Messages 6-91 

B-l R3000 Memory Space B-l 

B-2 R3000 I/O Space B-l 

B-3 VAX Memory Space B-^4 

B-4 CVAX I/O Space B^ 

B-5 External IPRs B-6 

B-6 Q22-bus Memory Space B-7 

B-7 Q22-bus I/O Space with BBS7 Asserted B-7 

C— 1 Data and Address Signal Assignments C— 3 

C— 2 Control Signal Assignments C— 4 

C-3 Power and Ground Signal Assignments C— 5 

C-4 Spare Signal Assignments C— 5 

C— 5 Data Transfer Operations C— 6 

C-6 Bus Signals for Data Transfers C-6 

C-7 Bus Pin Identifiers C-45 



About This Manual 



This KN210 CPU Module Set Technical Manual documents the functional, 
physical, and environmental characteristics of the KN210 CPU module 
set and also includes some information on the MS650 memory expansion 
modules. The KN210 CPU module set consists of the KN210 processor 
module and the KN210 I/O module. 



Intended Audience 

This document is intended for a design engineer or applications 
programmer who is familiar with Digital's extended LSI-11 bus (Q22- 
bus) and the MIPS instruction set. This manual should be used along 
with the VAX Architecture Reference Manual as a programmer's reference 
to the module. 



Organization 

The manual is divided into six chapters and four appendices. 

Chapter 1, Overview, introduces the KN210 processor module, the 
KN210 I/O module and MS650 memory modules, including module 
features and specifications. 

Chapter 2, Configuration and Installation, describes the configuration 
and installation of the KN210 module set and MS650 modules in Q22-bus 
backplanes and system enclosures. 

Chapter 3, Architecture, provides a description of KN210 registers, 
instruction set and memory. 

Chapter 4, KN210 Firmware, describes the R3000 entry/dispatch code, 
boot diagnostics, device booting sequence, console program and console 
commands. 



XXI 



xxii About This Manual 



Chapter 5, Diagnostic Processor, describes the diagnostic processor 
registers. 

Chapter 6, Maintenance Mode Firmware, describes the diagnostic 
processor entry/dispatch code, boot diagnostics, device booting sequence, 
console program and console commands. 

Appendix A, KN210 Specifications, describes the physical, electrical, 
and environmental specifications for the KN210 CPU and I/O modules. 

Appendix B, Address Assignments, provides a map of R3000 and 
diagnostic processor address space. 

Appendix C, Q22-bus Specification, describes the low end member of 
Digital's bus family. All of Digital's microcomputers use the Q22-bus. 

Appendix D, Acronyms, provides a list of the acronyms used in this 
manual. 



Conventions 

This manual uses the following conventions: 

Convention Meaning 

Note Provides general information you should be aware of. 

Caution Provides information to prevent damage to equipment. 

<x:y> Represents a bit field, a set of lines, or signals, ranging from 

x through y. For example, RO <7:4> indicates bits 7 through 
4 in general purpose register RO. 

[x:y] Represents a range of bytes, from y through x. 



Return | Text within a box identifies a key, such as the Return | key. 

i Boldface small n indicates variables. 



About This Manual xxiii 



Related Documents 

You can order the following documents from Digital: 



Document 



Order Number 



VAX Architecture Reference Manual 
BA213 Enclosure Maintenance 



EY-3459E-DP 
EK-189AA-MG 



You can order these documents from: 

Digital Equipment Corporation 

Accessories and Supplies Group 

P.O. Box CS2008 

Nashua, NH 03061 

Attention: Documentation Products 



1 



Overview 



This chapter provides a brief overview of the KN210 CPU module set and 
MS650 memory modules. 

1 .1 Introduction 

The KN210 CPU module set consists of the KN210 processor module, 
shown in Figure 1—1, and the KN210 I/O module, shown in Figure 1—2. 
Both are quad-height modules for the Q22-bus (extended LSI- 11 bus). The 
KN210 processor module features the R3000 RISC processor. The KN210 
I/O module features built-in DSSI and Ethernet controllers. The KN210 
CPU module set is designed for use in high speed multiuser, multitasking 
environments. 

The KN210 CPU module set is used in the DECsystem 5400. The 
DECsystem 5400 utilizes a BA213 enclosure. Refer to the BA213 
Enclosure Maintenance for a detailed description of the enclosure. 

The KN210 CPU module set and MS650 memory modules combine to 
form a RISC CPU/memory subsystem that uses the Q22-bus, DSSI bus, 
and Ethernet to communicate with mass storage and I/O devices. The 
KN210 CPU module set and MS650 modules mount in standard Q22-bus 
backplane slots that implement the Q22-bus in the AB rows and the CD 
interconnect in the CD rows. The KN210 CPU module set can support up 
to four MS650 modules, if enough Q22/CD slots are available. 

The KN210 CPU module set communicates with the console device 
through the H3602-SA CPU cover panel, which also contains configuration 
switches, an LED display, and Ethernet connector. 



1-1 



1—2 Overview 



=■■*".■ M 




II I !!] fllfli i II Il.!lt.i I 



Figure 1-1 KN210 Processor Module 



Overview 1—3 







WA-OG 5.4-83 



Figure 1-2 KN210 I/O Module 

The major functional blocks of the KN210 CPU module set are shown in 
Figure 1-3, and are described in the following paragraphs. 



1—4 Overview 



ETHERNET 




^prV| 



J2 CD FINGERS 



MA-X0610-S9 



Figure 1-3 KN210 Block Diagram 



1 .2 R3000 RISC Processor 

The central processor of the KN210 module set is the R3000 RISC 
processor chip. The R3000 chip implements two tightly coupled processors 
in a single VLSI chip. One processor is a 32-bit CPU, and the second is a 
system control processor (CPO). 



Overview 1 —5 



The combined CPU/CPO processors provide the following features: 

• 32-bit operation 

• A 5-stage pipeline 

• On chip cache control 

• On chip memory management 

• Coprocessor interface 

1 .3 Floating-Point Accelerator 

The floating-point accelerator is implemented by the R3010 floating-point 
accelerator (FPA) chip. The R3010 FPA operates as a coprocessor for 
the R3000 processor and extends the R3000's instruction set to perform 
arithmetic operations on values in floating-point representations. The 
R3010 FPA interfaces with the R3000 processor to form a tightly-coupled 
unit with seamless integration of floating-point and fixed-point instruction 
sets. 

1 .4 Cache Memory 

To maximize CPU performance, the KN210 module utilizes a system of 
cache memory. The cache memory is organized as two separate 64 Kbyte 
cache; one for instructions and the other for data. 

1 .5 Memory Controller 

The main memory controller is implemented by a VLSI chip called the 
CMCTL. The CMCTL supports up to 64 Mbytes of ECC memory with a 
500-550 ns cycle time for word transfers. This memory resides on up to 
four MS650 memory modules. 

1 .6 Diagnostic Processor 

The diagnostic processor provides extensive diagnostic capabilities for the 
KN210 CPU module set. 

1 .7 MS650-BA Memory Modules 

The MS650-BA memory modules are 16 Mbyte, 450 ns, 39-bit wide arrays 
(32-bit data and 7-bit ECC) implemented with 1 Mbyte dynamic RAMs 
in surface-mount packages. MS650-BA memory modules are single, 
quad-height, Q22-bus modules, as shown in Figure 1—4. 



1—6 Overview 



1 .8 MS650-AA Memory Modules 

The MS650-AA memory modules are 8 Mbyte, 450 ns, 39-bit wide arrays 
(32-bit data and 7-bit ECC) implemented with 256 Kbyte dynamic RAMs 
in zig-zag in-line packages (ZIPs). MS650-AA memory modules are single, 
quad-height, Q22-bus modules, as shown in Figure 1—4. 

The MS650 modules communicate with the KN210 through the MS650 
memory interconnect, which utilizes the CD rows of backplane slots 2 
through 4, and a 50-pin ribbon cable. The KN210 memory subsystem 
supports a maximum of four memory modules. 





/1S65&-AA 



Figure 1-4 MS650 Memory Modules 



1 .9 DSSI Interface 

The Digital small storage interconnect (DSSI) bus interface, located on 
the KN210 I/O module, is implemented by the SII chip and four 32K x 8 
static RAMs. The DSSI interface allows the KN210 to transmit packets of 
data to, and receive packets of data from up to seven other DSSI devices. 
The KN210 system configurations contain one or more RF-series fixed 
disk devices, connected through the DSSI bus. 



Overview 1—7 



1.10 Ethernet Interface 

The KN210 I/O module features an on-board network interface that is 
implemented through the LANCE chip and four 32K x 8 static RAMs. 
When used in conjunction with the H3602-SA CPU cover panel, this 
interface allows the KN210 CPU module set to be connected to either a 
ThinWire or standard Ethernet network. 

The Ethernet interface includes registers for control and status reporting 
as well as a DMA controller, a 24 word transmit silo and a 24 word receive 
silo. 

1.11 Q22-bus Interface 

The Q22-bus interface is implemented by the CQBIC chip, located on the 
KN210 processor module. The CQBIC chip supports up to 16- word, block 
mode transfers between a Q22-bus DMA device and main memory, and up 
to 2-word, block mode transfers between the CPU and Q22-bus devices. 
The Q22-bus interface contains the following: 

• A 16-entry map cache for the 8,192-entry, main memory-resident 
"scatter-gather" map, used for translating 22-bit Q22-bus addresses 
into 26-bit main memory addresses 

• Interrupt arbitration logic that recognizes Q22-bus interrupt requests 
BR7-BR4 

• Q22-bus termination (240 D) 

1 .1 2 System Support Functions 

System support functions are implemented by the system support chip 
(SSC), located on the KN210 processor module. The SSC provides console 
and boot code support functions, operating system support functions, 
timers, and many extra features, including the following: 

Word-wide ROM unpacking 

1 Kbyte battery backed-up RAM 

Halt arbitration logic 

Console serial line 

Interval timer with 10 ms interrupts 

Time-of-year clock with support for battery back-up 

IORESET register 



1—8 Overview 



• Programmable CDAL bus timeout counter 

• Two programmable timers similar in function to the VAX standard 
interval timer 

• A register for controlling the diagnostic LEDs 

1.13 Firmware 

The firmware consists of 256 Kbytes of 16 bit-wide ROM, located on two 
128K EPROMs (one for each processor). The firmware gains control when 
the processor halts, and contains programs that provide the following 
services: 

• Board initialization 

• Power-up self-testing of the KN210 processor and I/O modules, and 
the MS650 modules 

• Emulation of a subset of the VAX standard console (automatic/manual 
bootstrap, automatic/manual restart, and a simple command language 
for examining/altering the state of the processor) 

• Booting from supported Q22-bus devices, DSSI, or Ethernet 

• Multilingual capability 

• MOP support 

1 .14 Clock Functions 

The clock chip provides the following functions: 

• Generates two MOS clocks for the CPU and the main memory 
controller 

• Generates three auxiliary clocks for other miscellaneous TTL logic 

• Synchronizes reset signal for the CPU and the main memory 
controller 

• Synchronizes data ready and data error signals for the CPU and the 
main memory controller 



2 

Installation and Configuration 



2.1 Introduction 

This chapter contains information required to install the KN210 CPU 
module set in a system. The following topics are discussed: 

• Installing the KN210 CPU module set 

• Configuring the KN210 

• KN210 connectors 

• H3602-SA CPU cover panel 

2.2 Installing the KN210 CPU Module Set 

The KN210 CPU module set can only be installed in BA213 backplanes. 

The KN210 I/O and processor modules must be installed in slots 1 and 
2, respectively, of the Q22/CD backplane (Figure 2-1). MS650 memory 
modules must be installed in slots immediately adjacent to the KN210 
processor module. Up to four MS650 modules may be installed, occupying 
slots 3, 4, 5 and 6 respectively. A 50-pin ribbon cable is used to connect 
the KN210 processor and I/O modules to each other. Another 50-pin cable 
is used to connect the KN210 processor module to the MS650 memory 
module(s), as shown in Figure 2—2. 



2-1 



2—2 Installation and Configuration 



SLOT 1 
SLOT 2 
SLOT 3 




1 














Q22-bus I C D 






I INTERCONNECT 




SLOT 4 
SLOT 5 








* 


SLOT 6 








* 


SLOT 7 










SLOT 8 










SLOT 9 










SLOT 10 










SLOT 11 










SLOT 12 


< 


' 


r 





KN210 I/O MODULE 

KN210 PROCESSOR MODULE 

MS650 NO.1 

MS650 NO. 2 

MS650 NO. 3 

MS6S0 NO.4 



MA-X0608-89 



Figure 2-1 Processor, I/O and Memory Module Placement 



Installation and Configuration 2—3 



KN210 

PROCESSOR 

MODULE 




UA-xoaoe-ee 



Figure 2-2 Cable Connections 



2.3 Configuring the KN21 

The following parameters must be configured on the KN210: 

• Operation switch 

• Function switch 



2—4 Installation and Configuration 

• Console serial line baud rate 

• DSSI node ID 

• Ethernet port connector selection 

These parameters are configured using the H3602-SA CPU cover panel. 

2.4 KN21 Connectors 

The KN210 uses several connectors, and four rows of module fingers (A, 
B, C, and D) to communicate with the console device, main memory, the 
Q22-bus, the DSSI controller, and the Ethernet controller. The contact 
finger identification of the KN210 CPU and I/O modules is described in 
Appendix C. 

The orientation of the connectors, and the LED indicators is shown in 
Figure 2-3. 



CONSOLE/ 
ETHERNET 
CONNECTORS 




Figure 2-3 KN210 Connector and LED Orientation 



Installation and Configuration 2—5 



2.4.1 Console/Ethernet Connector 



The Console/Ethernet connector (Jl) is a 40-pin connector used to bus 
signals to/from the Ethernet interface and system console, and for 
configuration and display purposes. A multi-tapped 40-pin cable provides 
the physical connection between the KN210 processor and I/O boards 
and the H3602-SA CPU cover panel. Table 2-1 gives the pinouts for the 
console connector. 



Table 2-1 Console/Ethernet Connector (J1) Pinouts 



Pin 


Mnemonic 


Module 


Meaning 


01 


XMIT-H 


I/O 


Transmit - output to the LAN 
interface 


02 


XMIT+H 


I/O 


Transmit + output to the IAN 
interface 


03 


GND 


I/O 


Ground 


04 


GND 


I/O 


Ground 


05 


GND 


I/O 


Ground 


06 


RCV-H 


I/O 


Receive - input from the LAN 
interface 


07 


RCV+H 


I/O 


Receive + input from the LAN 
interface 


08 


GND 


I/O 


Ground 


09 


GND 


I/O 


Ground 


10 


GND 


I/O 


Ground 


11 


COL-H 


I/O 


Collision 


12 


COLrl-H 


I/O 


Collision 


13 


GND 


I/O 


Ground 


14 


GND 


I/O 


Ground 


15 


GND 


I/O 


Ground 


16 


GND 


I/O 


Ground 


17 


+12 V 


I/O 


Fused +12 Vdc 


18 


GND 


I/O 


Ground 


19 


DTRH 


Processor 


Data terminal ready 


20 


GND 


Processor 


Ground 


21 


TXDL 


Processor 


Transmit data 


22 


SPID0 L 


— 


Not used with H3602-SA 


23 


SPID1L 


— 


Not used with H3602-SA 



2—6 Installation and Configuration 



Table 2-1 (Cont.) Console/Ethernet Connector (J1) Pinouts 

Pin Mnemonic Module Meaning 

Receive data 

Receive data 

Not used with H3602-SA 

Fused +5 Vdc 

Console bit rate <02:00>. These three 

bits determine the console baud rate. 

They are configured using the select 

switch on the inside of the H3602-SA. 

LED code register bits <03:00>. 

When asserted each of these four 

output signals 

Lights a corresponding LED on the 

module. 

LEDCODE<03:00> are asserted (low) 

by power-up and by the negation 

of DCOK when the processor is 

halted. They are updated by boot 

and diagnostic programs from the 

BDR. 

Halt enable. This input signal 

controls the response to an external 

halt condition. IfENBHALTis 

asserted (low), then the KN210 halts 

and enters the console program if 

any of the following occur: 

• The program executes a halt 
instruction in kernel mode. 

• The console detects a break 
character. 



24 


RXDL 


Processor 


25 


RXDH 


Processor 


26 


SPIDO L 


— 


27 


+5V 


Processor 


28 


CONBITRATE2 L 


Processor 


29 


CONBITRATE1 L 




30 


CONBITRATEO L 




31 


LEDCODE0 L 


Processor 


32 


LEDCODE1 L 


Processor 


33 


LEDCODE2 L 


Processor 


34 


LEDCODE3 L 


Processor 



35 



ENBHALT L 



Processor 



The Q22-bus halt line is 
asserted. 



Installation and Configuration 2—7 



Table 2-1 (Cont.) Console/Ethernet Connector (J1) Pinouts 



Pin Mnemonic 



Module Meaning 



36 


BDCODE1 L 


Processor 


37 


BDCODE0 L 




38 


VBATH 


Processor 


39 


CPUCODE1 L 


Processor 


40 


CPUCODE0 L 


Processor 



If ENBHALT is negated (high), then 

the halt line and break character 

are ignored and the ROM program 

responds to a halt instruction by 

restarting or rebooting the system. 

ENBHALT is read by software from 

the BDR. 

Boot and diagnostic code <01:00>. 

This 2-bit code indicates power-up 

mode, and is read by software from 

the BDR. 

Battery backup voltage for the TODR 

clock. 

CPU code <01:00>. This 2-bit code 

is read by software from the BDR. 

The configuration for the CPU code is 

as follows: 

00 Normal operation 

01 Reserved 

10 Reserved 

11 Reserved 



2.4.2 DSSI/I/O Connector 

Connector J2 on the I/O module is a dual 50-pin connector (100 pins 
total) that provides two interfaces. The lower 50 pins are used as the 
interconnect between the I/O module and the processor module; the upper 
50 pins are used for the DSSI controller. 



2—8 Installation and Configuration 



Table 2—3 lists the pinouts for the I/O interconnect portion of J2 (lower 
50 pins). Table 2—2 lists the pinouts for the DSSI portion of J2 (upper 50 
pins). 



Table 2-2 DSSI Connector (I/O Module J2-Upper) Pinouts 



Pin 



Mnemonic 



Pin 



Mnemonic 



51 


DSSIDATAO L 


76 


VTERMH 


52 


GND 


77 


VTERMH 


53 


DSSIDATA1 L 


78 


VTERMH 


54 


GND 


79 


GND 


55 


DSSIDATA2 L 


80 


Unused 


56 


GND 


81 


GND 


57 


DSSIDATA3 L 


82 


Unused 


58 


GND 


83 


GND 


59 


DSSIDATA4 L 


84 


Unused 


60 


GND 


85 


GND 


61 


DSSIDATA5 L 


86 


DSSIBSY L 


62 


GND 


87 


GND 


63 


DSSIDATA6 L 


88 


DSSIACK L 


64 


GND 


89 


GND 


65 


DSSIDATA7 L 


90 


DSSIRST L 


66 


GND 


91 


GND 


67 


DSSIPARITY L 


92 


Unused 


68 


GND 


93 


GND 


69 


Unused 


94 


DSSISEL L 


70 


GND 


95 


GND 


71 


Unused 


96 


DSSIC/D L 


72 


GND 


97 


GND 


73 


VTERMH 


98 


DSSIREQ L 


74 


VTERMH 


99 


GND 


75 


VTERMH 


100 


DSSII/O L 



Installation and Configuration 2—9 



Table 2-3 I/O Connector (I/O Module J2-Lower) Pinouts 



Pin 



Signal 



Pin Signal 



01 


GND 


26 


BCDAL10 H 


02 


BCDAL9 H 


27 


GND 


03 


BCDAL8H 


28 


BCDAL29 H 


04 


BCDAL7 H 


29 


BCDAL28 H 


05 


GND 


30 


BCDAL27 H 


06 


BCDAL6H 


31 


GND 


07 


BCDAL5H 


32 


BCDAL26 H 


08 


BCDAL4H 


33 


BCDAL25 H 


09 


BCDAL3H 


34 


BCDAL24 H 


10 


GND 


35 


BCDAL23 H 


11 


BCDAL2 H 


36 


GND 


12 


BCDAL1 H 


37 


BCDAL22 H 


13 


BCDAL0H 


38 


BCDAL21 H 


14 


BCDAL19 H 


39 


BCDAL20 H 


15 


GND 


40 


BM3L 


16 


BCDAL18 H 


41 


GND 


17 


BCDAL17 H 


42 


BM2L 


18 


BCDAL16 H 


43 


BM1L 


19 


BCDAL15 H 


44 


BM0L 


20 


GND 


45 


Not Used 


21 


BCDAL14 H 


46 


GND 


22 


BCDAL13 H 


47 


Not Used 


23 


BCDAL12 H 


48 


IOPRESENT L 


24 


GND 


49 


BCDAL31 H 


25 


BCDAL11 H 


50 


BCDAL30 H 



2.4.3 Memory Connector 

Connector J2 on the processor module is a dual 50-pin connector (100 
pins total) that provides two interfaces. The lower 50 pins are used as 
the memory interface between the KN210 module set and the MS650 
memory modules; the upper 50 pins are used as the interconnect between 
the processor module and the I/O module. 



2-10 Installation and Configuration 



Table 2—4 lists the pinouts for the memory portion of J2 Qower 50 pins). 
Table 2-3 lists the pinouts for the I/O interconnect portion of J2 (upper 50 
pins). 



Table 2-4 Memory Connector (Processor Module J2-Lower) Pinouts 



Pin 



Mnemonic 



Pin 



Mnemonic 



01 


GND 


26 


DMD10H 


02 


DMD9H 


27 


GND 


03 


DMD8H 


28 


DMD29H 


04 


DMD7H 


29 


DMD28H 


05 


GND 


30 


DMD27H 


06 


DMD6H 


31 


GND 


07 


DMD5H 


32 


DMD26H 


08 


DMD4H 


33 


DMD25H 


09 


DMD3H 


34 


DMD24H 


10 


GND 


35 


DMD23H 


11 


DMD2H 


36 


GND 


12 


DMD1H 


37 


DMD22H 


13 


DMD0H 


38 


DMD21H 


14 


D MD19 H 


39 


DMD20H 


15 


GND 


40 


DMD38H 


16 


D MD18 H 


41 


GND 


17 


D MD17 H 


42 


DMD37H 


18 


D MD16 H 


43 


DMD36H 


19 


D MD15 H 


44 


DMD35H 


20 


GND 


45 


DMD34H 


21 


D MD14 H 


46 


GND 


22 


D MD13 H 


47 


DMD33H 


23 


D MD12 H 


48 


DMD32H 


24 


GND 


49 


DMD31H 


25 


D MD11 H 


50 


DMD30H 



Installation and Configuration 2—1 1 



2.5 H3602-SA CPU Cover Panel 

The H3602-SA CPU cover panel is a special I/O panel that is used in 
BA213 enclosures. A multi-tapped 40-pin ribbon cable provides the 
physical connection between the H3602-SA CPU cover panel and the Jl 
connectors of both the KN210 processor and I/O modules. The H3602- 
SA fits over backplane slots 1 and 2, covering both the KN210 I/O and 
processor modules. 

The H3602-SA CPU cover panel (Figure 2-4) includes the features and 
controls specified in Table 2-5. 



Table 2-5 H3602-SA Features and Controls 



Outside 



Inside 



Modified modular jack (MMJ) 
SLU connector 

Operation switch 

Hexadecimal LED display 

Function switch 

Standard/ThinWire Ethernet 
connectors 

StandardYThinWire Ethernet 
selector 

Indicator LEDs 



Baud rate rotary switch 

Battery backup unit (BBU) for TODR clock 

40-pin cable connector 

List of baud rate switch settings 



2—1 2 Installation and Configuration 






n 



MA-X0787-88 



Figure 2-4 H3602-SA CPU Cover Panel 



3 



Architecture 



This chapter describes KN210 registers, instruction set, and memory. The 
chapter covers the following KN210 topics: 

RISC processor 

Floating-point accelerator 

Cache memory 

Main memory system 

Console serial line 

Time-of-year clock and timers 

Boot and diagnostic facility 

Q22-bus interface 

Mass-storage interface 

Network interface 

3.1 R3000 RISC Processor 

The central processor of the KN210 is the R3000 RISC processor plus its 
associated R3010 floating-point unit. 



3-1 



3—2 Architecture 



3.1 .1 Processor Features 

The R3000 chip implements two tightly coupled processors in a single 
VLSI chip. One processor being a 32-bit CPU, and the second being a 
system control processor (CPO). 

The combined CPU/CPO processors provide these features. 

• 32-bit operation - The R3000 is a 32-bit machine with 32 32-bit 
registers, all addressing is 32-bits. 

• Pipelined - The CPU contains a five stage pipeline capable of 
executing one instruction per 50 ns cycle. 

• On chip cache control - The R3000 supports separate instruction 
and data caches of up to 256 Kbytes. (The KN210 supports 64 Kbytes 
each.) Both caches can be accessed in a single CPU cycle. 

• On chip memory managment - A four Gbyte virtual address space 
is mapped with a 64 entry fully associative translation lookaside 
buffer. 

• Coprocessor interface - The R3000 provides a tightly coupled 
coprocessor interface for up to four coprocessors. The first CPO is 
contained on the CPU chip and the second CP1 is the floating-point 
unit. CP2 and CP3 are unused in the KN210. 

• Write buffers - The KN210 uses four R3020 4-word deep write 
buffers. All writes pass through these write buffers. 

NOTE 

Because all writes pass through the write buffers, software 
writing to I/O devices must wait for the write buffers to 
empty before reading from locations that could be affected 
by these I/O writes. This can be accomplished by conditionally 
branching on the coprocessor 3 condition. (BC3F branches if 
the WB is not empty and BC3T branches if the WB is empty.) 

3.1.1.1 General Purpose Registers 

The R3000 provides 32 32-bit general purpose registers, a 32-bit program 
counter, and 2 32-bit registers used in integer multiply and divide 
operations. 



Architecture 3—3 



3.1.1.2 Instruction Set 

R3000 instructions have three types, as shown in Figure 3—1. A summary 
of R3000 instructions is given in Table 3-1. 



I-TYPE (IMMEDIATE) 

31 26 25 21 20 16 15 



OP 


RS 


RT 


IMMEDIATE 


J-TYPE (JUMP) 

31 26 25 















OP 


TARGET 


R-TYPE (REGISTER) 
31 26 25 




21 20 




16 15 11 10 6 


5 





OP 


RS 


RT 


RD 


RE 


FUNCT 



MA-XOS20-BS 



Figure 3-1 Instruction Set Types 



Table 3-1 Instruction Summary 



OP 



Description 



Group 



LB 


Load byte 


LBU 


Load byte unsigned 


LH 


Load halfword 


LHU 


Load halfword unsigned 


LW 


Load word 


LWL 


Load word left 


LWR 


Load word right 


SB 


Store byte 


SH 


Store halfword 


SW 


Store word 


SWL 


Store left 


SWR 


Store right 


ADDI 


Add immediate 



Load/Store instructions 



Arithmetic instructions (ALU 
immediate) 



3-4 Architecture 



Table 3-1 (Cont.) Instruction Summary 



OP 


Description 


Group 


ADDIU 


Add immediate unsigned 




SLTI 


Set on less than immediate 




SLTIU 


Set on less than immediate 
unsigned 




ANDI 


AND immediate 




ORI 


OR immediate 




XORI 


Exclusive OR immediate 




LUI 


Load upper immediate 




ADD 


Add 


Arithmetic instructions (3-operand, 
register-type) 


ADDU 


Add unsigned 




SUB 


Subtract 




SUBU 


Subtract unsigned 




SLT 


Set on less than 




SLTU 


Set on less than unsigned 




AND 


AND 




OR 


OR 




XOR 


Exclusive OR 




NOR 


NOR 




SLL 


Shift left logical 


Shift instructions 


SRL 


Shift right logical 




SRA 


Shift right arithmetic 




SLLV 


Shift left logical variable 




SRLV 


Shift right logical variable 




SRAV 


Shift right arithmetic 
variable 




MULT 


Multiply 


Multiply/divide instructions 


MULTU 


Multiply unsigned 




DIV 


Divide 




DIVU 


Divide unsigned 




MFHI 


Move from HI 




MTHI 


Move to HI 




MFLO 


Move from LO 




MTLO 


Move to LO 




J 


Jump 


Jump and branch instructions 


JAL 


Jump and link 




JR 


Jump to register 





Architecture 3-5 



Table 3-1 (Cont.) Instruction Summary 



OP 



Description 



Group 



JALR 


Jump and link register 


BEQ 


Branch, on equal 


BNE 


Branch not equal 


BLEZ 


Branch on less than or equal 




to zero 


BGTZ 


Branch on greater than zero 


BLTZ 


Branch on less than zero 


BGEZ 


Branch on greater than or 




equal to zero 


BLTZAL 


Branch on less than zero and 




link 


BGEZAL 


Branch on greater than or 




equal to zero and link 


SYSCALL 


System call 


BREAK 


Break 


LWCz 


Load word from coprocessor 


SWCz 


Store word to coprocessor 


MTCz 


Move to coprocessor 


MFCz 


Move from coprocessor 


CTCZ 


Move control to coprocessor 


CFCz 


Move control from 




coprocessor 


COPz 


Coprocessor operation 


BCzT 


Branch on coprocessor z true 


BCzF 


Branch on coprocessor z false 


MTCO 


Move to CPO 



MFCO Move from CPO 

TLBR Read indexed TLB entry 

TLBWI Write indexed TLB entry 

TLBWR Write random TLB entry 

TLBP Probe TLB for matching 

entry 

RFE Restore from exception 



Special instructions 
Coprocessor instructions 



System control coprocessor (CPO) 
instructions 



3-6 Architecture 



3.1.2 Coprocessors 

The R3000 can operate with up to four tightly coupled coprocessors, two 
of which are implemented in the KN210. 

3.1.2.1 Coprocessor (0) 

The system control coprocessor (CPO) is part of the R3000 chip itself. Its 
function is to support the virtual memory system and exception handling 
functions. It contains the translation lookaside buffer (TLB) plus the 
following registers: 

Entry Hi - High half of a TLB entry. 

Entry Lo - Low half of a TLB entry. 

Index - Programmable pointer into the TLB. 

Random - Pseudo-random pointer into the TLB. 

Status - Mode, interrupt enables, and diagnostic status information. 

Cause - Cause of last exception. 

EPC - Exception program counter. 

Context - Pointer into kernel's virtual page table entry array. 

BadVA - Most recent bad virtual address. 

PRId - Processor revision identification. 

3.1.2.2 Coprocessor (1) 

Coprocessor one (CP1) is the R3010 floating-point unit. The R3010 
floating-point processor implements the IEEE arithmetic functions. 

3.1 .3 Memory Management 

The R3000 provides for logical expansion of memory space by translating 
virtual address into physical addresses, 2 Gbytes for the kernel and 
2 Gbytes for user, as shown in Figure 3—2 and Figure 3-3. Virtual 
addresses are mapped through the use of a translation lookaside buffer 
(TLB). This buffer contains 64 entries, each mapping a 4 Kbyte block. 
Controls are included for R/W accesses, cache or nocache, and process 
identification. 



1024Mbyte < 



512Mbyte 



512Mbyte , 



2048Mbyte , 



R3000 VIRTUAL 



KSEG 2 
KERNEL 
MAPPED 



KSEG 1 
KERNEL 
UNMAPPED 
UNCACHED 



KSEG 
KERNEL 
UNMAPPED 
CACHED 



KUSEG 
USER 
MAPPED 
CACHEABLE 



Architecture 3-7 



R30OO PHYSCIAL 



ANYWHERE 



>ANYWHERE 



MEMORY 

00OO0O0O 



4Mbyta 



(256Mbyte 



266Mbyt 



1 



256Mby te 



256Mbyte I 



256Mbyte 256Mbyto 



DIAGNOSTIC 
PROCESSOR 
PHYSICAL 



NO ACCESS 



Q22-bus 

30000000 



DIAGNOSTIC 
PROCESSOR 
I/O SPACE 

20000000 



DIAGNOSTIC 
PROCESSOR 
MEMORY 
SPACE _„ 



UA-X0A17-SB 



Figure 3-2 R3000 Virtual to Physical Memory Map 



3-8 Architecture 



R3000 PHYSCIAL 




2000 0OO0 
1FC2 OOOO 
1FC0 OOOO 



1800 OOOO 
1700 OOOO 
1600 OOOO 
1500 OOOO 
1400 OOOO 



40 OOOO 



NO ACCESS 



MEMORY 
64 Mbyte 




NO ACCESS 



Q22-bus MEMORY 



NO ACCESS 



NO ACCESS 



NO ACCESS 



ROM DUAL ACCESS 



MEMORY 
64 Mbyte 



3O00 0000 
2FC2 0000 

2FC0 0000 



2600 0000 
2500 0000 



2000 2000 
2000 0000 




MA-X0616-8S 



Figure 3-3 R3000 to I/O Memory Map 



Architecture 3—9 



3.1.3.1 Operating Modes 

The R3000 has two operating modes, kernel and user. All exceptions are 
handled in kernel mode. User mode is entered through the restore from 
exception (RFE) instruction. 

User mode - 2 Gbytes of virtual address are available in this mode. 
Virtual addresses are extended with a 6-bit process identifier field 
allowing up to 64 user processes. All references in this mode are mapped 
through the TLB. Pages can be made cacheable or uncacheable through 
the use of bits within the TLB entries. 

Kernel mode - contains four separate segments. 

• KUSEG - references treated the same as user mode. 

• KSEGO - references cached but not mapped. 

• KSEG1 - references not cached and not mapped. 

• KSEG2 - references mapped and cacheability determined through the 
TLB entries. 

3.1 .3.2 EntryHi and EntryLo Registers 

These registers are used to read, write, or probe the TLB. During 
exceptions, these registers are loaded with information about the address 
that caused the exception. The format of these registers is the same as 
the format of a TLB entry. A TLB EntryHi register (EH) is shown in 
Figure 3—4. A TLB EntryLo register (EL) is shown in Figure 3-5. 



63 




44 43 




38 37 




32 


VPN 


PID 


ZEROS 



MA-X0621-88 



Figure 3-4 TLB EntryHi Register 



3—1 Architecture 



Data Bit 



Definition 



EntryHi<63:44> (VPN) Virtual page number. Contains bits <31:12> of the 
virtual address. 

Entry Hi<43:38> (PID) Process ID field. Allows multiple processes to share the 
TLB. 



EntryHi<37:32> 


EntryHi<5:0> Unused. Read 


as 0's. 










31 


12 11 10 


9 


8 


7 





PFN 


N 


D 


V 


G 


ZEROS 



MA-X0622-89 



Figure 3-5 TLB EntryLo Register 



Data Bit 



Definition 



EntryLo<31:12> 

EntryLo<ll> 

EntryLo<10> 

EntryLo<9> 

EntryLo<8> 

EntryLo<7:0> 



(PFN) Page frame number. Contains bits <31:12> of the 
physical address. 

(N) Non-Cacheable. When set, the page mapped by this entry 
will not be cached. 

(D) Dirty. Setting this bit marks the page mapped by this entry 
as writeable. 

(V) Valid. This bit marks the page as valid, letting translation 
take place, otherwise a TLBL or TLBS miss will occur. 

(G) Global. When set, the R3000 will ignore the PID match 
requirement for translations through this entry. 

Unused. Read as 0's. 



Architecture 3—1 1 



3.1.3.3 Index Register 

The index register (IR) is used to index into the TLB when doing either 
TLB reads or TLB writes. The high-order bit returns status information 
for the probe instruction. The format for the index register is shown in 
Figure 3-6. 



31 


30 




14 


13 




8 


7 







P 


ZEROS 


INDEX 


ZEROS 



MA-X0623-89 



Figure 3-6 Index Register 



Data Bit 



Definition 



Index<31> (P) Probe failure. Set to (1) if the last probe instruction failed. 

Index<30:14> Unused. Read as 0's. 

Index<13:8> Indexes the TLB entry for TLB reads or writes. 

Index<7:0> Unused. Read as 0's. 

3.1.3.4 Random Register 

The random register (RR) is used when replacing TLB entries. The 
TLBWR instruction is used to write the TLB entry pointed to by this 
register. The first 8 TLB entries will never be written using the TLBWR 
instruction. The format for the random register is shown in Figure 3—7. 



31 




14 13 




8 


7 





ZEROS 


RANDOM 


ZEROS 



MA-X0624-88 



Figure 3-7 Random Register 



3—1 2 Architecture 



Data Bit 



Definition 



Random<31:14> Unused. Read as O's. 

Random<13:8> Random index into the TLB ranging from 8 to 63. 

Random<7:0> Unused. Read as O's. 



3.1.4 Exception Handling Registers 

Exceptions are handled through the use of six coprocessor zero (CPO) 
registers and one module specific interrupt status register. Software uses 
these registers during exception handling to determine the cause of the 
exception. These registers are described in the following sections. 

3.1 .4.1 Cause Register 

The cause register (CR) is a 32-bit register used when servicing 
exceptions. It describes why the last exception was taken. All bits in 
this register are read only except for the SW bit. The format for the cause 
register is shown in Figure 3-8. 



31 30 29 28 27 



BD • 
ZERO 
CE<1:0> 



ZEROS 



10 9 8 7 6 5 



SW<1:0> 
ZEROS 



EC<3:0> 



ZEROS 



MA-X0SS6-BS 



Figure 3-8 Cause Register 



Data Bit 



Definition 



CR<31> (BD) Branch delay. Set to 1 if last exception was taken while 

executing in a branch delay slot. 

CR<30> Unused. Read as zero. 

CR<29:28> CE<1:0> Coprocessor error. Indicates the unit number 

referenced when a coprocessor unusable exception is taken. 



CR<27:16> 



Unused. Read as O's. 



Architecture 3—1 3 



Data Bit 



Definition 



CR<15:10> 



CR<9:8> 

CR<7:6> 
CR<5:2> 



IP<5:0> Interrupt pending. Indicates which of the external 
interrupts are pending. Table 3—2 shows the mapping of 
physical interrupt requests to the cause register IP<5:0> status 
bits. Figure 3-9 shows the flow of the interrupt acknowledge 
daisy chain. 

SW<1:0> Software interrupts. Indicates which software 
interrupts are pending. These bits are read/write. 

Unused. Read as O's. 

(EC) Exception code. The exception code field is described in 
the following table. 



Number Name 



Description 



0(10) 


INT 


1 


MOD 


2 


TLBL 


3 


TLBS 


4 


ADEL 


5 


ADES 


6 


IBE 


7 


DBE 


8 


SYS 


9 


BP 


10 


RI 


11 


CPU 


12 


OVF 


13-15 


Reserved 



External interrupt 

TLB modification exception 

TLB miss exception Goad or fetch) 

TLB miss exception (store) 

Address error exception (load or fetch) 

Address error exception (store) 

Bus error exception (fetch) 

Bus error exception (load or fetch) 

Syscall exception 

Breakpoint exception 

Reserved instruction exception 

Coprocessor unusable exception 

Arithmetic overflow exception 



CR<1:0> 



Unused. Read as O's. 



3-1 4 Architecture 



Table 3-2 R3000 Interrupt Mapping 



Bit Priority Interrupt Request 



Corresponding 
Vector Diagnostic 
Register Processor IPL 



IP<5> 


2 


FPU 






IP<4> 


1 


HALT 






IP<3> 


3 


PWRFL, MER1, MERO, 
WEAR 






IP<2> 


4 


100 Hz ->BIRQ7 


VRR3 


IPL17 


IP<1> 


5 


DSSI ->NI ->BIRQ6 


VRR2 


IPL16 


IP<0> 


6 


BIRQ5 ->Console ->Timers 


VRR1 


IPL15 






->BIRQ4 


VRRO 


IPL14 







PROCESSOR MODULE 






I/O MODULE 




R30OO 




SSC 




100 Hz CLOCK 




DSSI 








1 














I 
NO I/O i 
MODULE S^ 

1 

1 








Q22-bu» 


t 


Nl 























MA-X061B-BB 



Figure 3-9 Interrupt Acknowledge Daisy Chain 



Architecture 3—1 5 



3.1.4.2 Exception Program Counter 

The exception program counter (EPC) contains the virtual address of the 
instruction which caused the exception to be taken. If the instruction is 
in a branch delay slot, the EPC will contain the virtual address of the 
preceding branch or jump instruction. 

3.1.4.3 Status Register 

The status register (SR) is a 32-bit register containing various processor 
status. The format for the status register is shown in Figure 3-10. 



31 29 


27 23 22 


21 


20 


19 


18 


17 


16 


15 8 


7 


6 


5 


4 


3 


2 


1 





CU<3:0> 




BEV 


TS 


PE 


CM 


PZ 


swc 


ISC 


INTR<7:0> 




KUO 


IEO 


KUP 


IEP 


KUC 


IEC 


ZEROS - 




















ZEROS - 



















MA-X0626-88 



Figure 3-10 Status Register 



Data Bit 



Definition 



SR<31:28> CU<3:0> Coprocessor usability. CU<3:0> controls the 

availability of the four possible coprocessors. Setting a CU 
bit to 1 enables the coprocessor. 

SR<27:23> Unused. Read as O's. 

SR<22> (BEV) Bootstrap exception vector. When set to 1 causes the 

R3000 to use the alternate bootstrap vectors for UTLB miss 
and general exceptions. 

SR<21> (TS) Translation buffer shutdown. Set to 1 if the R3000 has 

disabled the translation buffer due to error. 

SR<20> (PE) Parity error. Set to 1 if a cache parity error occurs. 

Cleared by writing a 1. 

SR<19> (CM) Cache miss. Set to 1 if most recent D-cache load resulted 

in a miss when the D-cache is isolated. 

SR<18> (PZ) Parity zero. Setting to 1 forces parity bits to 0. 

SR<17> (SWC) Swap caches. Swaps I-cache and D-cache. 



3—1 6 Architecture 



Data Bit 



Definition 



SR<16> (ISC) Isolate cache. Isolates the D-cache from the memory 

system. 

SR<15:10> INTR<7:2> Interrupt mask. Setting these INTR bits to 1 

enables their corresponding hardware interrupt. 

SR<9:8> INTR<1:0> Interrupt mask. Setting these INTR bits to 1 

enables their corresponding software interrupt. 

SR<7:6> Unused. Read as O's. 

SR<5> (KUO) Kernel/user mode, old. Set to if kernel, 1 if user. 

SR<4> (IEO) Interrupt enable, old. Set to 1 to enable, to disable. 

SR<3> (KUP) Kernel/user mode, previous. Set to if kernel, 1 if user. 

SR<2> (IEP) Interrupt enable, previous. Set to 1 to enable, to 

disable. 

SR<1> (KUC) Kernel/user mode, current. Set to if kernel, 1 if user. 

SR<0> (IEC) Interrupt enable, current. Set to 1 to enable, to disable. 

3.1.4.4 BadVaddr Register 

The BadVaddr register (BVA.) saves the virtual address for any addressing 
exception. 

3.1 .4.5 Context Register 

The context register (CR) is used by the UTLB miss handler. The CR 
saves some of the same information as the BadVaddr register. The format 
for the context register is shown in Figure 3—11. 

31 21 20 2 10 



PTEBaso 



BadVPN 



ZEROS- 

MA-X0627-B9 



Figure 3-11 Context Register 



Architecture 3—1 7 



Data Bit 



Definition 



CR<31:21> (PTEBase) Page table entry base. Holds the base for the page 

table entry. 

CR<20:2> (BadVPN) Bad virtual page number. Holds the failing virtual 

page number. Read only. Set by hardware. 

CR<1:0> Unused. Read as O's. 

3.1.4.6 Processor Revision Identifier Register 

The processor revision identifier register (PRR) contains implementation 
and revision numbers for the R3000 chip. The format for the processor 
revision identification register is shown in Figure 3—12. 



31 



16 15 



8 7 



PTEBase 


IMP 


REV 



MA-X0652-8S 



Figure 3-12 Processor Revision identifier Register 



Data Bit 



Definition 



PRR<31:16> Unused. Read as O's. 

PRR<15:8> IMP<7:0> Implementation identifier. 

PRR<7:0> REV<7:0> Revision identifier. 



3.1.4.7 interrupt Status Register 

The interrupt status register, (R3000 address 1008 4000; diagnostic 
processor address 2008 4000) returns information concerning the four 
conditions which can cause an INTR3 interrupt. It can be accessed by 
either processor but only has meaning for the R3000. The diagnostic 
processor must make sure ISR<2:0> are before transferring control 
to the R3000. The format for the interrupt status register is shown in 
Figure 3-13. 



3—1 8 Architecture 



31 




3 




2 




1 




D 


READ AS ONES 










HALT 

PR PL 










MFR1 „ 






MERO 









MA-XO628-80 



Figure 3-13 Interrupt Status Register 



Data Bit 



Definition 



ISR<31:4> Unused. Read as 1's. 

ISR<3> (HALT) Halt interrupt. Indicates a halt interrupt request is 

posted. 

ISR<2> (PRFL) Power fail interrupt. Indicates an impending power fail 

condition. Must be written zero (0) to enable subsequent power 
fail interrupts. Cleared on powerup. 

ISR<1> (MER1) Memory error one. Indicates a memory error interrupt 

has been generated either by the CQBIC or the CMCTL. Must 
be written as zero (0) to enable subsequent CQBIC or CMCTL 
memory error interrupts. Cleared on powerup. 

ISR<0> (MERO) Memory error zero. Indicates a write error has 

occurred and that the address contained in the WEAR register 
is valid. Must be written as to enable subsequent MERO 
interrupts. Cleared on powerup. 



3.1.4.8 Vector Read Registers 

The R3000 uses the vector read registers when servicing IRQ<2:0> 
interrupt requests. Reading any of these registers generates an interrupt 
acknowledge cycle on the peripheral bus (CP bus). Bits <15:0> of the 
data returned will be a unique vector from the device responding to 
the interrupt acknowledge. If no device responds, a BUS ERROR 
EXCEPTION will be taken by the R3000. 



Architecture 3—1 9 



System software must guarantee interrupt requests from higher priority 
devices service before lower priority devices. This can be accomplished by 
reading the VRR register corresponding to the highest IRQ<2:0> pending 
in the cause/status register. The diagnostic processor has no access to 
these registers. 

Register IPL Generated 



VRRO 


14 (lowest priority) 


VRR1 


15 


VRR2 


16 


VRR3 


17 (highest priority) 



NOTE 

Because of the way interrupt requests are posted on the Q22-bus, 
interrupts at high priorities will also assert interrupt requests at 
lower levels. It is important that software read, the VRR register 
corresponding to the highest IRQ pending in the CAUSE register. 
Lower level requests pending because of higher level interrupts 
will deassert at the same time the high level request deasserts. 

Vector Read Register 

Vector read register (VRRO) cannot be accessed by the diagnostic 
processor. The format for VRRO (R3000 address 1600 0050) is shown 
in Figure 3-14. 

31 16 15 



READ AS ONES 



IPL 14 VECTOR INFORMATION 



MA-X0629-89 



Figure 3-14 Vector Read Register 



3-20 Architecture 



Vector Read Register 1 



Vector read register 1 (VRR1) cannot be accessed by the diagnostic 
processor. The format for VRR1 (R3000 address 1600 0054) is shown 
in Figure 3—15. 



31 



16 15 



READ AS ONES 


IPL 15 VECTOR INFORMATION 



MA-X0647-8S 



Figure 3-15 Vector Read Register 1 

Vector Read Register 2 

Vector read register 2 (VRR2) cannot be accessed by the diagnostic 
processor. The format for VRR2 (R3000 address 1600 0058) is shown 
in Figure 3-16. 



31 




16 


15 







READ AS ONES 


IPL 16 VECTOR INFORMATION 



MA-X0648-89 



Figure 3-16 Vector Read Register 2 

Vector Read Register 3 

Vector read register 3 (VRR3) cannot be accessed by the diagnostic 
processor. The format for VRR3 (R3000 address 1600 005C) is shown 
in Figure 3-17. 



31 




16 


15 







READ AS ONES 


IPL 17 VECTOR INFORMATION 



MA-X0640-89 



Figure 3-17 Vector Read Register 3 



Architecture 3-21 

3.1.5 Exceptions 

The R3000 handles exceptions through the use of three different exception 
vectors. These exception vectors are the following: 

• BFCO 0000 virtual - RESET exception vector. 

• 8000 0000 virtual - UTLB miss exception vector. 

• 8000 0080 virtual - General exception vector. 

If the bootstrap exception vector (BEV) bit is set in the status register 
then the UTLB and general exception vector addresses will be changed, 
putting them in the ROM address space. 

• BFCO 0100 virtual - UTLB miss exception vector. 

• BFCO 0180 virtual - General exception vector. 

3.1.5.1 General Exception Vector 

The general exception vector handles the following exceptions: 

• Address error 

• Breakpoint 

• Bus error 

• Coprocessor unusable 

• Interrupt 

• Overflow 

• Reserved instruction 

• TLB miss 

• TLB modified 

3.1 .5.2 Reset Exception Vector 

The reset exception is taken on power up when the R3000 RESET signal 
is deasserted. The reset vector (BFCO 0000 virtual) resides in Ksegl 
which is unmapped and uncached. It is also the first location in the ROM 
(physical 1FC0 0000). 



3-22 Architecture 



When the reset exception occurs, the contents of all R3000 registers are 
undefined except for the following: 

• The TS, SWc, KUc, and IEc bits of the status register are cleared. 

• The BEV bit of the status register is set. 

• The random register is cleared. 

3.2 Floating-Point Accelerator 

The KN210 floating-point accelerator (FPA) is implemented by a single 
VLSI chip called the R3010. The R3010 FPA operates as a coprocessor 
for the R3000 RISC processor and extends the R3000's instruction set to 
perform arithmetic operations on values in floating-point representations. 

The R3010 FPA features 16 64-bit registers that can each be used to hold 
single-precision or double-precision values. The FPA also includes a 32-bit 
status/control register. 

The 3010 FPA connects to the R3000 RISC processor to form a tightly- 
coupled unit with complete integration of floating-point and fixed-point 
instruction sets. Since each unit receives and executes instructions 
in parallel, some floating-point instructions can execute at the same 
single-cycle per instruction rate as fixed-point instructions. 

3.2.1 Floating-Point Accelerator Instructions 

Like the R3000 RISC processor, the R3010 FPA uses a load/store- 
oriented instruction set. with single-cycle loads and stores. Floating-point 
operations are started in a single cycle and their execution is overlapped 
with other fixed-point or floating-point operations. 

The FPA monitors the R3000 processor instruction stream. If an 
instruction does not apply to the coprocessor, it is ignored. If an 
instruction does apply to the coprocessor, the FPA executes that 
instruction and transfers necessary result and exception data to the 
R3000 main processor. 



Architecture 3-23 



3.3 Cache Memory 

To maximize CPU performance, the KN210 utilizes two separate 64 Kbyte 
caches. 

3.3.1 Cache Organization 

The cache is organized as two separate caches; one for instructions and 
one for data. Each cache contains 16K entries (or 64 Kbyte). Both caches 
have the same organization; they are direct mapped, with a block size 
of one word (4-bytes). Fill size is either one word (4-bytes) or four words 
(16-bytes). 

3.3.2 Cache Isolation 

The data cache can be isolated from the memory system by setting the 
ISC bit in the status register. This allows software to flush a cache 
location in a single cycle without affecting the memory system. 

3.3.3 Cache Swapping 

To help in flushing the instruction cache, the caches can be swapped. This 
is done by setting the SWC bit in the status register. Precautions must 
be taken before setting this bit. The processor must be executing from an 
uncached region and must not have been executing loads or stores near to 
the time of doing the swap. 

3.3.4 Cache Line Format 

Each cache line is 60 bits long, and each cache can be accessed once 
per cycle. This is accomplished by alternately putting out instruction 
cache addresses and data cache addresses on each phase of the clock. 
These cache addresses are latched externally. The cache line format is 
shown in Figure 3—18. The tag field of the cache line format is shown in 
Figure 3-19. 



59 




56 


55 


53 


52 




32 


31 







DataP 


TagP 


TAG 


Data 



MA-X0660-BS 



Figure 3-18 Cache Line Format 



3—24 Architecture 



Data Bit 



Definition 



<59:56> 
<55:53> 
<52:32> 
<31:0> 



(DataP) Holds the parity bits for the data field. 
(TagP) Holds the parity bits for the tag field. 
(TAG) Holds the valid bit and the page frame number. 
(Data) Cached data. 



52 51 



32 



PFN 



MA-X0651-89 



Figure 3-19 Tag Field 



Data Bit 



Definition 



<52> (V) Holds the valid bit. The R3000 sets V whenever it writes a 

full word to the cache and clears V for any other writes. This 
allows software to flush a cache location by doing byte store 
operations. 

<51:32> (PFN) Page frame number. 



3.4 Main Memory System 

The KN210 includes a main memory controller implemented by a single 
VLSI chip called the CMCTL. The KN210 main memory controller 
communicates with the MS650 memory boards over the MS650 memory 
interconnect, which utilizes the CD interconnect for the address and 
control lines and a 50-pin, ribbon cable for the data lines. It supports 
up to four MS650 memory boards for a maximum of 64 Mbytes of ECC 
memory. 

The memory controller can be configured for one or zero wait states 
under program control (using MEMCSR17<13>). For the KN210, 
MEMCSR17<13> must be set to one. 



Architecture 3—25 



The controller supports synchronous word read references, and masked 
or unmasked synchronous write references generated by the CPU as 
well as synchronous twoword read references generated by cacheable 
CPU references that miss the cache. Table 3-3 gives CPU read reference 
timing. Table 3—4 gives CPU write reference timing. 



Table 3-3 CPU Read Reference Timing 



Data Type 



CVAX 

Timing (ns) 



R3000 Timing (ns) 



Word 


400 


500-550 


Twoword 


600 


No access 


First word 


400 


No access 


Second word 


200 


No access 


Aborted reference 


400 


No access 


Fourword 


No access 


1150-1200 



Table 3-4 CPU Write Reference Timing 



Data Type 



CVAX 
Timing (ns) 



R3000 Timing (ns) 



Word 

Word (masked) 



200 
500 



400-450 
700-750 



The controller also supports asynchronous word and twoword DMA read 
references and masked and unmasked asynchronous word, twoword, 
threeword, and fourword DMA write references from the Q22-bus 
interface. Table 3—5 gives Q22-bus interface read reference timing. 
Table 3-6 gives Q22-bus interface write reference timing. 



Table 3-5 Q22-bus Interface Read Reference Timing 



Data Type 



Timing (ns) 



Word 


500 


Twoword 


800 


First word 


500 


Second word 


300 



3—26 Architecture 



Table 3-6 Q22-bus Interface Write Reference Timing 

Data Type Timing (ns) 



Word 


400 


Word (masked) 


600 


Twoword 


700 


First word 


400 


Second word 


300 


Twoword (masked) 


1100 


First word 


400 


Second word 


700 


Threeword 


1000 


First word 


400 


Second word 


300 


Third word 


300 


Threeword (masked) 


1400 


First word 


400 


Second word 


300 


Third word 


700 


Fourword 


1300 


First word 


400 


Second word 


300 


Third word 


300 


Fourth word 


300 


Fourword (masked) 


1700 


First word 


400 


Second word 


300 


Third word 


300 


Fourth word 


700 



The timing in Table 3—6 assumes no exception conditions are encountered 
during the reference. Exception conditions will add the following amount 
of time if they are encountered during a reference: 



Architecture 3-27 



Exception Condition Time Added (ns) 



Correctable error 100 

Uncorrectable error 200 read 

Uncorrectable error 100 write 

CDAL parity error 100 write 

Refresh collision 400 



The main memory controller contains eighteen registers. Sixteen registers 
are used to configure each of the sixteen possible banks in main memory. 
One register is used to control the operating mode of all memory banks 
and one register captures state on main memory errors. 

3.4.1 Main Memory Organization 

Main memory is logically and physically divided into four boards that 
correspond to the four possible MS650 memory expansion modules that 
can be attached to a KN210. Each board can contain zero (no memory 
module present), 1 (as on the KN210), or 2 (MS650-AA present) memory 
bank(s). Each bank contains 1,048,576 (1M) words. Each word is divided 
into 4 data bytes and is stored with 7 ECC check bits, resulting in a 
memory array width of 39 bits. 

3.4.2 Main Memory Addressing 

The KN210 main memory controller is capable of controlling up to 16 
banks of RAM, each bank containing 4 Mbytes of storage. Each bank of 
main memory has a programmable base address, determined by the state 
of bits <25:22> of the main memory configuration register associated with 
each bank. 

A 4 Mbyte bank is accessed when bit <29> of the physical address is equal 
to 0, indicating a VAX. memory space read/write reference, bits <28:26> 
of the physical address are equal to zero, indicating a reference within 
the range of the main memory controller, and the bank number of the 
bank matches bits <25:22> of the physical address. The remainder of the 
physical address (bits <21:2>) are used to determine the row and column 
of the desired word within the bank. The byte mask lines are ignored on 
read operations, but are used to select the proper byte(s) within a word 
during masked word write references. 



3-28 Architecture 



3.4.3 Main Memory Behavior on Writes 

On unmasked CPU write references, the main memory controller operates 
in dump and run mode, terminating the CDAL bus transaction after 
latching the data, but before checking CDAL bus parity, calculating the 
ECC check bits, and transferring the data to main memory. 

On unmasked DMA write references by the Q22-bus interface: the data is 
latched; CDAL bus parity is NOT checked; the CDAL bus transaction is 
terminated; the ECC check bits are calculated; and the data is transferred 
to main memory. 

On single masked CPU or DMA write references: the referenced word 
is read from main memory; the ECC code checked; the check bits 
recalculated to account for the new data byte(s); the CDAL transaction is 
terminated; and the word is rewritten. 

On multiple transfer masked DMA writes, each word write is 
acknowledged, then the CDAL transaction is terminated. 

3.4.4 Main Memory Error Status Register 

The main memory status register (MEMCSR16) (R3000 address 1008 
0140 is diagnostic processor address 2008 0140 i&) is used to capture 
main memory error data. The format for MEMCSR16 is shown in 
Figure 3-20. 



31 302928 



9 8 7 6 



RDS ERROR 



RDSHIGH ERROR RATE 



CRD ERROR 



PAGE ADDRESS OF ERROR 



DMA ERROR 



CDAL BUS ERROR 



SYNDROME 



ECC ERROR SYNDROME 



J 



MA-1112-87 



Figure 3-20 Format for MEMCSR1 6 



Architecture 3-29 



Data Bit 



Definition 



MEMCSR16<31> 



MEMCSR16<30> 



MEMCSR16<29> 



MEMCSR16<28:9> 



RDS error. Read/Write to clear. When set, an uncorrectable 
ECC error occurred during a memory read or masked write 
reference. Cleared by writing a 1 to it. Writing a has no 
effect. Undefined if MEMCSR16<7> (CDAL bus error) is 
set. Cleared on power-up and the negation of DC OK when 
the processor is halted. 

RDS high error rate. Read/Write to clear. When set, an 
uncorrectable ECC error occurred while the RDS error 
log request bit was set, indicating multiple uncorrectable 
memory errors. Cleared by writing a 1 to it. Writing a has 
no effect. Undefined if MEMCSR16<7> (CDAL bus error) is 
set. Cleared on power-up and the negation of DCOK when 
the processor is halted. 

CRD error. Read/Write to clear. When set, a correctable 
(single bit) error occurred during a memory read or masked 
write reference. Cleared by writing a 1 to it. Writing a 
has no effect. Undefined if MEMCSR16<7> (CDAL bus 
error) is set. Cleared by writing a 1, on power-up and the 
negation of DCOK when the processor is halted. 

Page address of error. Read only. This field identifies the 
page (512 byte block) containing the location that caused 
the memory error. In the event of multiple memory errors, 
the types of errors are prioritized and the page address of 
the error with the highest priority is captured. Errors with 
equal priority do not overwrite previous contents. Writes 
have no effect. Cleared on power-up and the negation of 
DCOK when the processor is halted. 

The types of error conditions follow in order of priority: 

1. CDAL bus parity errors during a CPU write reference, 
as logged by the CDAL bus error bit. 

2. Uncorrectable ECC errors during a CPU or DMA read 
or masked write reference, as logged by the RDS error 
log bit. 

3. Correctable ECC errors during a CPU or DMA read or 
masked write reference, as logged by CRD error bit. 



3—30 Architecture 



Data Bit 



Definition 



MEMCSR16<8> 



MEMCSR16<7> 



MEMCSR16<6:0> 



DMA error. Read/Write to clear. When set, an error 
occurred during a DMA read or write reference. Cleared 
by writing a 1 to it. Writing a has no effect. Cleared on 
power-up and the negation of DCOK when the processor is 
halted. 

CDAL bus error. Read/Write to clear. When set, a CDAL 
bus parity error occurred on a CPU write reference. Cleared 
by writing a 1 to it. Writing a has no effect. Cleared on 
power-up and the negation of DCOK when the processor is 
halted. 

Error syndrome. Read only. This field stores the error 
syndrome. A non-zero syndrome indicates a detectable 
error has occurred. A unique syndrome is generated for 
each possible single bit (correctable) error. A list of these 
syndromes and their associated single bit errors is given 
in Table 3-7. Any non-zero syndrome that is not contained 
in Table 3—7 indicates a multiple bit (uncorrectable) error 
has occurred. This field handles multiple errors in the same 
manner as MEMCSR16<28:9>. Cleared on power-up and 
the negation of DCOK when the processor is halted. 



Table 3-7 Error Syndromes 



Syndrome 
<6:0> 



Bit Position in Error 



0000000 


No error detected 




Data bits (0-32 decimal) 


1011000 





0011100 


1 


0011010 


2 


1011110 


3 


0011111 


4 


1011011 


5 


1011101 


6 


0011001 


7 


1101000 


8 


0101100 


9 



Architecture 3-31 



Table 3-7 (Cont.) Error Syndromes 



Syndrome 
<6:0> 



Bit Position in Error 



0101010 


10 


1101110 


11 


0101111 


12 


1101011 


13 


1101101 


14 


0101001 


15 


1110000 


16 


0110100 


17 


0110010 


18 


1110110 


19 


0110111 


20 


1110011 


21 


1110101 


22 


0110001 


23 


0111000 


24 


1111100 


25 


1111010 


26 


0111110 


27 


1111111 


28 


0111011 


29 


0111101 


30 


1111001 


31 




Check bits (32-38 decimal) 


0000001 


32 


0000010 


33 


0000100 


34 


0001000 


35 


0010000 


36 


0100000 


37 


1000000 


38 



0000111 



Result of incorrect check bits written on detection of a CDAL 
parity error. 



AH others 



Multi-bit errors 



3-32 Architecture 



3.4.5 Main Memory Control and Diagnostic Status Register 

The main memory control and diagnostic status register (MEMCSR17) 
(R3000 address 1008 0144 16 ; diagnostic processor address 2008 0144 16 ) 
is used to control the operating mode of the main memory controller as 
well as to store diagnostic status information. This register is unique to 
CPU designs that use the CMCTL memory controller chip (Figure 3—21). 



1312 11 10 9 8 7 6 5 4 3 2 1 



MBZ 



CRD INTERRUPTENABLE 



FORCE REFRESH REQUEST 



ERROR DETECT DISABLE 



MBZ 



DIAGNOSTIC CHECK MODE 



CHECK BITS 



MA- 1122-87 



Figure 3-21 Format for MEMCSR17 



Data Bit 



Definition 



MEMCSR17<31:13> Unused. This field reads as zero and must be written as zero. 



MEMCSR17<12> 



CRD interrupt enable. Read/Write. When cleared, single-bit 
errors are corrected by the ECC logic, but no interrupt is 
generated. When set, single-bit errors are corrected by the 
ECC logic and they cause a diagnostic processor interrupt to 
be generated at IPL 1A with a vector of 54 i6- This bit has no 
effect on the capturing of error information in MEMCSR16, 
or on the reporting of uncorrectable errors. Cleared on 
power-up and the negation of DCOK when the processor is 
halted. 



Architecture 3—33 



Data Bit 



Definition 



MEMCSR17 
<11> 



MEMCSR17 
<10> 



MEMCSR17 
<9:8> 

MEMCSR17 
<7> 



Force refresh request. Read/Write. When cleared, the refresh 
control logic operates in normal mode (refresh every 11.3 us). 
When set, one memory refresh operation occurs immediately 
after the MEMCSR write reference that set this bit. Setting 
this bit provides a mechanism for speeding up the testing of 
the refresh logic during manufacturing test of the controller 
chip. This bit is cleared by the memory controller upon 
completion of the refresh operation. Cleared on power-up and 
the negation of DCOK when the processor is halted. 

Memory error detect disable. Read/Write. When set, error 
detection and correction (ECC) is disabled, so all memory 
errors go undetected. When cleared, error detection, 
correction, state capture and reporting (through MEMCSR16) 
is enabled. Cleared on power-up and the negation of DCOK 
when the processor is halted. 

Unused. This field reads as zero and must be written as zero. 



Diagnostic check mode. Read/Write. When set, the contents 
of MEMCSR17 <6:0> are written into the 7 ECC check bits of 
the location (even if a CDAL parity error is detected) during 
a memory write reference. When cleared, the 7 check bits 
calculated by the ECC generation logic are loaded into the 7 
ECC check bits of the location during a write reference and a 
memory read reference will load the state of the 7 ECC check 
bits of the location that was read into MEMCSR17 <6:0>. 
Cleared on power up and the negation of DCOK when the 
processor is halted. 

NOTE 

Diagnostic check mode is restricted to unmasked 
memory write references. No masked write references 
are allowed when diagnostic check mode is enabled. 



3—34 Architecture 



Data Bit Definition 



MEMCSR17 Check bits. Read/Write. When the diagnostic check mode 

<6:0> bit is set, these bits are substituted for the check bits that 

are generated by the ECC generation logic during a write 
reference. When the diagnostic check mode bit is cleared, 
memory read references load the state of the 7 ECC check 
bits of the location that was read into MEMCSR16 <6:0>. 
Cleared on power-up and the negation of DCOK when the 
processor is halted. 



3.4.6 Main Memory Error Detection and Correction 

The KN210 main memory controller generates CDAL bus parity on CPU 
read references. The actions taken following the detection of a CDAL bus 
parity error depend on the type of write reference. 

For unmasked diagnostic processor write references, incorrect check bits 
are written to main memory (potentially masking an as yet undetected 
memory error) along with the data. An interrupt is generated at IPL ID 
through vector 

60 i6 on the next cycle and MCSR16 <7> is set. The incorrect check 
bits are determined by calculating the seven correct check bits, and 
complementing the three least significant bits. 

For masked diagnostic processor write references: incorrect check bits 
are written to main memory (potentially masking an as yet undetected 
memory error) along with the data, unless an uncorrectable error is 
detected during the read portion; MEMCSR16 <7> is set; and a machine 
check abort is initiated. If an uncorrectable error is detected on the 
read portion, no write operation takes place. The incorrect check 
bits are determined by calculating the seven correct check bits, and 
complementing the three least significant bits. 

The memory controller protects main memory by using a 32-bit modified 
Hamming code to encode the 32-bit data word with seven check bits. 
This allows the controller to detect and correct single-bit errors in the 
data field and detect single bit errors in the check bit field and double-bit 
errors in the data field. The most likely causes of these errors are failures 
in either the memory array or the 50-pin cable. 



Architecture 3—35 



Upon detecting a correctable error on a read reference or the read portion 
of a masked write reference, the data is corrected (if it is in the data field). 
Before placing it on the CDAL bus, or back in main memory, a diagnostic 
processor interrupt is generated at IPL 1A through vector 
54 16 (IRQ 3 interrupt for the R3000), bit <29> of MEMCSR16 is set, bits 
<28:9> of MEMCSR16 are loaded with the address of the page containing 
the location that caused the error, and bits <6:0> are loaded with the 
error syndrome which indicates which bit was in error. If the error was 
detected on a DMA reference, MEMCSR16 <8> is also set. 

NOTE 

The corrected data is not rewritten to main memory, so the single 

bit error will remain there until rewritten by software. 

Upon detecting an uncorrectable error, the action depends on the type of 
reference being performed. 

On a demand read reference: the affected row of the diagnostic processor 
cache is invalidated; bit <31> of MEMCSR16 is set; bits <28:9> of 
MEMCSR16 are loaded with the address of the page containing the 
location that caused the error; and bits <6:0> are loaded with the error 
syndrome which indicates that the error was uncorrectable and a machine 
check abort is initiated. If the read was a local-miss, global-hit read, or 
a read of the Q22-bus map, MEMCSR16 <8> and DSER <4> are also set, 
and DEAR <12:0> are loaded with the address of the page containing the 
location that caused the error. 

On a request read reference: the diagnostic processor prefetch or fill 
cycle is aborted, but no machine check occurs; bit <31> of MEMCSR16 is 
set; bits <28:9> of MEMCSR16 are loaded with the address of the page 
containing the location that caused the error; and bits <6:0> are loaded 
with the error syndrome which indicates that the error was uncorrectable. 

On the read portion of masked write reference: bit <31> of MEMCSR16 
is set; bits <28:9> of MEMCSR16 are loaded with the address of the page 
containing the location that caused the error; and bits <6:0> are loaded 
with the error syndrome which indicates that the error was uncorrectable 
and a machine check abort is initiated on the diagnostic processor. An 
IRQ 3 interrupt is generated on the R3000 side. 



3—36 Architecture 



On a DMA read reference: bit <31> and bit <8> of MEMCSR16 are 
set; bits <28:9> of MEMCSR16 are loaded with the address of the page 
containing the location that caused the error; bits <6:0> are loaded with 
the error syndrome which indicates that the error was uncorrectable; 
DSER <4> is set; DEAR <12:0> are loaded with the address of the page 
containing the location that caused the error; BDAL <17:16> are asserted 
on the Q22-bus along with the data to notify the receiving device (unless 
it was a map read by the Q22-bus interface during translation); and a 
diagnostic processor interrupt is generated at IPL ID through vector 
60 is- An IRQ 3 interrupt is generated on the R3000 side. 

On a DMA masked write reference: bit <31> and bit <8> of MEMCSR16 
are set; bits <28:9> of MEMCSR16 are loaded with the address of the 
page containing the location that caused the error; bits <6:0> are loaded 
with the error syndrome which indicates that the error was uncorrectable; 
DSER <4> is set, DEAR <12:0> are loaded with the address of the page 
containing the location that caused the error; IPCR <15> is set to notify 
the initiating device; and a diagnostic processor interrupt is generated 
at IPL ID through vector 60 ig. An IRQ 3 interrupt is generated on the 
R3000 side. 

3.5 Console Serial Line 

The console serial line provides the KN210 processor with a full duplex, 
RS-423 EIA, serial line interface, which is also RS-232C compatible. The 
only data format supported is 8-bit data with no parity and one stop bit. 
Four registers control the operation of the console serial line. 

3.5.1 Console Registers 

There are four registers associated with the console serial line unit. They 
are implemented in the SSC (Table 3—8). 

Table 3-8 Console Registers 

Register Name Mnemonic 

Console receiver control/status RXCS 

Console receiver data buffer RXDB 

Console transmit control/status TXCS 

Console transmit data buffer TXDB 



Architecture 3—37 



3.5.1.1 Console Receiver Control/Status Register 

The console receiver control/status register (RXCS) is used to control 
and report the status of incoming data on the console serial line 
(Figure 3-22). 



31 8 7 


6 5 













UNUSED, RETURNS 




















RX DONE 




RX IE 







MA-1 118-87 



Figure 3-22 Console Receiver Control/Status Register 



Data Bit 



Definition 



RXCS <31:8> Unused. Read as zeros. Writes have no effect. 

RXCS <7> (RX DONE) Receiver done. Read only. Writes have no effect. 

This bit is set when an entire character has been received 
and is ready to be read from the RXDB register. This bit is 
automatically cleared when RXDB is read. It is also cleared 
on power-up and the negation of DCOK when the processor is 
halted. 

RXCS <6> (RX IE) Receiver interrupt enable. Read/Write. When set, 

this bit causes an interrupt to be requested at D?L 14 with an 
SCB offset of F8 if RX DONE is set. When cleared, interrupts 
from the console receiver are disabled. This bit is cleared on 
power-up and the negation of DCOK when the processor is 
halted. 

RXCS <5:0> Unused. Read as zeros. Writes have no effect 



3.5.1.2 Console Receiver Data Buffer 

The console receiver data buffer (RXDB) is used to buffer incoming data 
on the serial line and capture error information (Figure 3-23). 



3—38 Architecture 



1615141312 11 10 8 7 



ERR 



OVR ERR 



FRM ERR 



RCVBRK 







RECEIVED DATA BITS 



MA-1 119-87 



Figure 3-23 Console Receiver Data Buffer 



Data Bit 



Definition 



RXDB 
<31:16> 

RXDB <15> 



RXDB <14> 



RXDB <13> 



Unused. Always read as zero. Writes have no effect. 



(ERR) Error. Read only. Writes have no effect. This bit is set 
if RBUF <14> or <13> is set. It is clear if these two bits are 
clear. This bit cannot generate a program interrupt. Cleared 
on power-up and the negation of DCOK when the processor is 
halted. 

(OVR ERR) Overrun error. Read only. Writes have no effect. 
This bit is set if a previously received character was not read 
before being overwritten by the present character. Cleared by 
reading the RXDB, on power-up and the negation of DCOK 
when the processor is halted. 

(FRM ERR) Framing error. Read only. Writes have no effect. 
This bit is set if the present character did not have a valid 
stop bit. Cleared by reading the RXDB, on power-up and the 
negation of DCOK when the processor is halted. 

NOTE 

Error conditions remain present until the next character 

is received, at which point, the error bits are updated. 



RXDB <12> 



Unused. This bit alwayB reads as 0. Writes have no effect. 



Architecture 3-39 



Data Bit 



Definition 



RXDB <11> (RCV BRK) Received break. Read only. Writes have no effect. 

This bit is set at the end of a received character for which the 
serial data input remained in the space condition for 20 bit 
times. Cleared by reading the KXDB, on power-up and the 
negation of DCOK when the processor is halted. 

KXDB <10:8> Unused. These bits always read as 0. Writes have no effect. 

KXDB <7:0> Received data bits. Read only. Writes have no effect. These bits 

contain the last received character. 

3.5.1.3 Console Transmitter Control/Status Register 

The console transmitter control/status register (TXCS) is used to 
control and report the status of outgoing data on the console serial line 
(Figure 3-24). 



31 8 7 


6 5 




3 2 


1 


UNUSED, RETURNS 
















TX RDY 








TX IE 








MAINT 




XMITBRK 







MA-1 120-87 



Figure 3-24 Console Transmitter Control/Status Register 



Data Bit 



Definition 



TXCS <31:8> Unused. Read as zeros. Writes have no effect. 

TXCS <7> (TX RDY) Transmitter ready. Read only. Writes have no effect. 

This bit is cleared when TXDB is loaded and set when TXDB 
can receive another character. This bit is set on power-up and 
the negation of DCOK when the processor is halted. 



3—40 Architecture 



Data Bit 



Definition 



TXCS <6> (TX IE) Transmitter interrupt enable. Read/Write. When set, 

this bit causes an interrupt to be requested at IPL 14 with an 
SCB offset of FC if TX RDY is set. When cleared, interrupts 
from the console receiver are disabled. This bit is cleared on 
power-up and the negation of DCOK when the processor is 
halted. 

TXCS <5:3> Unused. Read as zeros. Writes have no effect. 

TXCS <2> (MAINT) Maintenance. Read/Write. This bit is used to 

facilitate a maintenance self-test. When MAINT is set, the 
external serial input is set to MARK and the serial output is 
used as the serial input. This bit is cleared on power-up and 
the negation of DCOK when the processor is halted. 

TXCS<1> Unused. Read as zero. Writes have no effect. 

TXCS<0> (XMIT BRK) Transmit break. Read/Write. When this bit is 

set, the serial output is forced to the space condition after 
the character in TXB<7:0> is sent. While XMIT BRK is set, 
the transmitter will operate normally, but the output line will 
remain low. Thus, software can transmit dummy characters 
to time the break. This bit is cleared on power-up and the 
negation of DCOK when the processor is halted. 

3.5.1 .4 Console Transmitter Data Buffer 

The console transmitter data buffer (TXDB) is used to buffer outgoing 
data on the serial line (Figure 3—25). 



31 




8 


7 6 5 4 3 2 





MBZ 








TRANSMITTED DATA BITS 


. 





MA-1123-87 



Figure 3-25 Console Transmitter Data Buffer 



Architecture 3-41 



Data Bit Definition 



TXDB<31:8> Unused. Writes have no effect. 

TXDB<7:0> Transmitted data bits. Write only. These bits are used to load 

the character to be transmitted on the console serial line. 



3.5.2 Break Response 

The console serial line unit recognizes a break condition which consists of 
20 consecutively received space bits. If the console detects a valid break 
condition, the RCV BRK bit is set in the RXDB register. If the break was 
the result of 20 consecutively received space bits, the FRM ERR bit is also 
set. If halts are enabled (ENBHALT asserted on the 40-pin connector), 
the KN210 will halt and transfer program control to diagnostic processor 
ROM location 2004 0000 when the RCV BRK bit is set if the diagnostic 
processor is running. If the R3000 is running an IRQ 4 interrupt is 
posted. RCV BRK is cleared by reading RXDB. Another mark followed by 
20 consecutive space bits must be received to set RCV BRK again. 

3.5.3 Baud Rate 

The receive and transmit baud rates are always identical and are 
controlled by the SSC configuration register bits <14:12>. 

The user selects the desired baud rate through pins <30:28> on the 
40-pin system support connector (CONBITRATE <02:00>), which are 
configured using the select switch on the inside of the H3602-SA. The 
KN210 firmware reads this code from boot and diagnostic register bits 
<6:4> and loads it into SSC configuration register bits <14:12>. Operating 
systems will not cause the baud rate to be transferred. The baud rate is 
only set on power up. 

Table 3—9 shows the baud rate select signal voltage levels (H or L), the 
corresponding INVERTED code as read in the boot and diagnostic register 
bits <6:4>, and the code that should be loaded into SSC configuration 
register bits <14:12>. 



3—42 Architecture 



Table 3-9 


Baud Rate Select 






Baud 


CONBITRATE 


BDR 




Rate 


<2:0> 


<6:4> 


SSC <14:12> 


300 


HHH 


000 


000 


600 


HHL 


001 


001 


1200 


HLH 


010 


010 


2400 


HLL 


on 


Oil 


4800 


LHH 


100 


100 


9600 


LHL 


101 


101 


19200 


LLH 


110 


110 


38400 


LLL 


111 


111 



3.5.4 Console Interrupt Specif ications 

The console serial line receiver and transmitter both generate interrupts 
at IPL 14. The receiver interrupts with a vector of F8 i6, while the 
transmitter interrupts with a vector of FC iq. See Section 3.1.4. 

3.6 Time-of-Year Clock and Timers 

The KN210 clocks include time-of-year clock (TODR), a subset interval 
clock (subset ICCS), and two additional programmable timers modeled 
after the YAX. standard interval clock, plus a 100 Hz interval timer used 
as the R3000 interval clock. 

3.6.1 R3000 Interval Timer Register 

The interval timer register (ITR) provides a 100 Hz interval timer for 
the R3000. The format for the ITR (R3000 address 1008 4010; diagnostic 
processor address 2008 4010) is shown in Figure 3—26. 



31 


B 


7 


6 


5 


4 




3 


2 


1 





UNUSED READ AS ONES 




IS 


IE 







1 


1 


1 


1 








OF 


__ 















MA-X0611-89 



Figure 3-26 Interval Timer Register 



Architecture 3-43 



Data Bit 



Definition 



ITR<31:8> Unused. Read as ones, writing has no effect. 

ITR<7> (IS) Interrupt status. Read only. Status bit, shows when a 

100 Hz interrupt is pending. Cleared by reading VRR2 for 
the R3000 and by an IPL16 interrupt acknowledge for the 
diagnostic processor. 

ITR<6> (IE) Interrupt enable. Read/Write. This bit enables and 

disables the ITR interval tinier interrupts. When this bit is 
set, an interval tinier interrupt is requested every 10 msec with 
an error of less than .01%. When this bit is clear, interval tinier 
interrupts are disabled. This bit is cleared on power-up and 
during an I/O reset. 

ITR<5> Unused. Read as zeros, writing has no effect. 

ITR<4> (IOP) I/O present. Read only. Set to 1 if the I/O module is not 

present. 

ITR<3:0> Unused. Read as ones, writing has no effect. 

Interval timer requests are posted at IPL 17 with a vector of CO: the 
interval timer is the highest priority device at this IPL for the R3000 
(Section 3.1.4). 

NOTE 

The vector read back for the ITR. interrupt when reading VRR2 
comes from the R3000 ROM if the R3000 is running and from the 
diagnostic processor ROM if the diagnostic processor is running. 
ROM location 5C must be programmed with the vector 2400 00C0 
(hex) for proper operation. 



3.6.2 Time-of- Year Clock 

The KN210 time-of-year clock (TODR) forms an unsigned 32-bit binary 
counter that is driven from a 100 Hz oscillator, so that the least significant 
bit of the clock represents a resolution of 10 ms, with less than .0025% 
error. The register counts only when it contains a non-zero value. This 
register is implemented in the SSC (Figure 3-27). 



3—44 Architecture 



TIME OF YEAR SINCE SETTING 



MA-1 124-87 



Figure 3-27 Time-of-Year Clock 

The TODR (R3000 address 1014 006C; diagnostic processor address 2014 
006C) is maintained during power failure by battery backup circuitry 
which interfaces; through the external connector, to a set of batteries 
which are mounted on the H3602-SA. The TODR will remain valid 
for greater than 162 hours when using the NiCad battery pack (three 
batteries in series). 

The SSC configuration register contains a battery low (BLO) bit which, if 
set after initialization, the TODR is cleared, and will remain at zero until 
software writes a non-zero value into it. 

NOTE 

After writing a non-zero value into the TODR, software should 

clear the BLO bit by writing a 1 to it. 

3.6.3 Interval Timer 

The KN210 interval tinier (ICCS), internal processor register 24, is 
implemented according to the VAX Architecture Reference Manual for 
subset processors. The interval clock control/status register (ICCS) is 
implemented as the standard subset of the standard VAX ICCS, while 
NICR and ICR are not implemented (Figure 3-28). 

31 7 6 5 



MBZ |IE 



MBZ 



MA-X1444-87A 



Figure 3-28 Interval Timer 



Architecture 3—45 



Data Bit Definition 



ICCS<31:7> Unused. Read as zeros, must be written as zeros. 

ICCS<6> (IE) Interrupt enable. Read/Write. This bit enables and 

disables the interval tinier interrupts. When the bit is set, 
an interval tinier interrupt is requested every 10 ms with an 
error of less than .01%. When the bit is clear, interval timer 
interrupts are disabled. This bit is cleared on power-up and the 
negation of DCOK when the processor is halted. 

ICCS<5:0> Unused. Read as zeros, must be written as zeros. 

Interval timer requests are posted at IPL 16 with a vector of CO: the 
interval timer is the highest priority device at this IPL. See Section 3.1.4. 

3.6.4 Programmable Timers 

The KN210 features two programmable timers. They are accessed as I/O 
space registers and a control bit has been added which stops the timer 
upon overflow. If so enabled, the timers will interrupt at IPL 14 upon 
overflow. The interrupt vectors are programmable and are set to 78 and 
7C by the firmware. 

Each timer is composed of four registers: a timer n control register, a 
timer n interval register, a timer n next interval register, and a timer n 
interrupt vector register, where n represents the timer number (0 or 1). 

3.6.4.1 Timer Control Registers 

The KN210 has two timer control registers, one for controlling timer 
(TCRO), and one for controlling timer 1 (TCR1). TCRO is accessible at 
R3000 address 

1014 0100 i 6 and diagnostic processor address 2014 0100 16 . TCR1 is 
accessible at R3000 address 1014 0110 i6 and diagnostic processor 2014 
0110 i6- These registers are implemented in the SSC (Figure 3-29). 



3—46 Architecture 



3130 



ERR 



8 7 6 5 4 



MBZ 



INT 
IE 



SGL 
XFR 
MBZ 
STP 



MBZ 
RUN 



MA-1 125-87 



Figure 3-29 Timer Control Registers 



Data Bit 



Definition 



TCRn<31> (ERR) Error. Read/Write to clear. This bit is set whenever the 

timer interval register overflows and INT is already set. Thus, 
the ERR indicates a missed overflow. Writing a 1 to this bit 
clears it. Cleared on power-up and the negation of DCOK when 
the processor is halted. 

TCRn<30:8> Unused. Read as zeros, must be written as zeros. 

TCRn<7> (INT) Read/Write to clear. This bit is set whenever the timer 

interval register overflows. If IE is set when INT is set, an 
interrupt is posted at IPL 14. Writing a 1 to this bit clears 
it. Cleared on power-up and the negation of DCOK when the 
processor is halted. 

TCRn<6> (IE) Read/Write. When this bit is set, the timer will interrupt 

at IPL 14 when the INT bit is set. Cleared on power-up and the 
negation of DCOK when the processor is halted. 

TCRn<5> (SGL) Read/Write. Setting this bit causes the timer interval 

register to be incremented by 1 if the RUN bit is cleared. If the 
RUN bit is set, then writes to the SGL bit are ignored. This 
bit always reads as 0. Cleared on power-up and the negation of 
DCOK when the processor is halted. 



Architecture 3—47 



Data Bit 



Definition 



TCRn<4> (XFR) Read/Write. Setting this bit causes the timer next 

interval register to be copied into the timer interval register. 
This bit is always read as 0. Cleared on power-up and the 
negation of DCOK when the processor is halted. 

TCRn<3> Unused. Read as zeros, must be written as zeros. 

TCRn<2> (STP) Read/Write. This bit determines whether the timer stops 

after an overflow when the RUN bit is set. If the STP bit is set 
at overflow, the RUN bit is cleared by the hardware at overflow 
and counting stops. Cleared on power-up and the negation of 
DCOK when the processor is halted. 

TCRn<l> Unused. Read as zeros, must be written as zeros. 

TCRn<0> (RUN) Read/Write. When set, the timer interval register is 

incremented once every microsecond. The INT bit is set when 
the timer overflows. If the STP bit is set at overflow, the 
RUN bit is cleared by the hardware at overflow and counting 
stops. When the RUN bit is clear, the timer interval register is 
not incremented automatically. Cleared on power-up and the 
negation of DCOK when the processor is halted. 



3.6.4.2 Timer Interval Registers 

The KN210 has two timer interval registers, one for timer (TIRO), and 
one for timer 1 (TIR1). TIRO is accessible at R3000 address 
1014 0104 165 diagnostic processor address 2014 0104 ig- TIR1 is 
accessible at diagnostic processor address 2014 0114 i&; R3000 address 
1014 0114 16 . 

The timer interval register is a read only register containing the interval 
count. When the run bit is 0, writing a 1 increments the register. When 
the RUN bit is 1, the register is incremented once every microsecond. 
When the counter overflows, the INT bit is set, and an interrupt is posted 
at IPL 14 if the IE bit is set. Then, if the RUN and STP bits are both 
set, the RUN bit is cleared and counting stops. Otherwise, the counter 
is reloaded. The maximum delay that can be specified is approximately 
1.2 hours. This register is cleared on power-up and the negation of DCOK 
when the processor is halted. 



3—48 Architecture 



3.6.4.3 Timer Next Interval Registers 

The KN210 has two timer next interval registers, one for timer (TNIRO), 
and one for timer 1 (TNIR1). TNIRO is accessible at diagnostic processor 
address 2014 0108 16 ; R3000 address 1014 0108 i6 . TNIR1 is accessible 
at diagnostic processor address 2014 0118 16 ; R3000 address 1014 0118 
16- These registers are implemented in the SSC. 

This read/write register contains the value which is written into the timer 
interval register after overflow, or in response to a 1 written to the XFR 
bit. This register is cleared on power-up and the negation of DCOK when 
the processor is halted. 

3.6.4.4 Timer Interrupt Vector Registers 

The KN210 has two timer interrupt vector registers, one for timer 
(TIVR0), and one for timer 1 (TTVK1). TIVR0 is accessible at R3000 
address 1014 010C i6 and diagnostic processor address 2014 010C i6- 
TIVR1 is accessible at R3000 address 1014 011C i 6 and diagnostic 
processor 2014 011C i6- These registers are implemented in the SSC 
and are set to 78 and 7C respectively by the resident firmware. 

This read/write register contains the timer's interrupt vector. Bits 
<31:10> and <1:0> are read as and must be written as 0. When 
TCRn<6> (IE) and TCRn<7> (INT) transition to 1, an interrupt is posted 
at IPL 14. When a timer's interrupt is acknowledged, the content of the 
interrupt vector register is passed to the CPU, and the INT bit is cleared. 
Interrupt requests can also be cleared by clearing either the IE or the INT 
bit. This register is cleared on power-up and the negation of DCOK when 
the processor is halted (Figure 3-30). 

31 10 9 2 10 



MBZ 


INTERRUPT VECTOR 


MBZ 



MA-1 126-87 



Figure 3-30 Timer Interrupt Vector Register 

NOTE 

Both timers interrupt at the same EPL (IPL 14) as the console 
serial line unit. When multiple interrupts are pending, the console 
serial line has priority over the timers, and tinier has priority 
over tinier 1. Refer to Section 3.1.4. 



Architecture 3—49 



3.7 Boot and Diagnostic Facility 

The KN210 boot and diagnostic facility features four registers, two 40-pin 
ROM sockets with 128 Kbytes of read-only memory per processor, and 1 
Kbyte of battery backed up RAM. The ROM and battery backed up RAM 
may be accessed by longword, word, halfword, or byte references. 

The KN210 CPU module populates the ROM sockets with 256 Kbytes of 
ROM (or EPROM). This ROM contains the KN210 resident firmware. One 
16-bit wide ROM is dedicated to each processor. If this ROM is replaced 
for special applications, the new ROM must initialize and configure the 
board, provide HALT and console emulation, as well as provide boot and 
diagnostic functionality. 

3.7.1 Boot and Diagnostic Register 

The boot and diagnostic register (BDR) is a byte-wide register located at 
the R3000 physical address 1008 4004 ig (diagnostic processor physical 
address 2008 4004 ig). It can be accessed by either processor, but not 
by external Q22-bus devices. The BDR allows either processor to read 
various KN210 configuration bits. Only the low byte of the BDR should 
be accessed, bits <31:8> are undefined (Figure 3—31). 

31 87643210 



UNDEFINED 










HLT ENB 










RRR CO _ 






CPU CD - 






BDG CD 









MA-X0660-88 



Figure 3-31 Boot and Diagnostic Register 



3—50 Architecture 



Data Bit 



Definition 



BDR<31:8> Undefined. Should not be read or written. 

BDR<7> (ENBHALT) Halt enable. Read only. Writes have no effect. 

This bit reflects the state of pin 35 (ENBHALT L) of the 40-pin 
connector. The assertion of this signal enables the halting of the 
CPU upon detection of a console break condition. On a power-up, 
the KN210 resident firmware reads the ENBHALT bit to decide 
whether to enter the console emulation program (ENBHALT set) 
or to boot the operating system (ENBHALT clear). 

BDR<6:4> (CONBITRATE) Console bit rate <02:00>. Read only. Writes have 

no effect. These three bits originate from pins <30:28> of the 
40-pin connector. They reflect the setting of the baud rate select 
switch on the H3602-SA. These bits are read only on power up. 



BDR<6:4> 



Baud Rate 



000 
001 
010 
011 
100 
101 
110 

111 



300 

600 

1200 

2400 

4800 

9600 

19200 

38400 



BDR<3:2> (CPUCODE) CPU code <01:00>. Read only. Writes have no 

effect. These two bits originate from pins <40:39> of the 40-pin 
connector. 



CPUCODE 

<01:0O> 



Configuration 



00 


Power Up 


01 


Reserved 


10 


Reserved 


11 


Reserved 



Architecture 3—51 



Data Bit Definition 



BDR<1:0> (BDCODE) Boot and diagnostic code <01:00>. Read only. Writes 

have no effect. This 2-bit code reflects the status of the 40-pin 
connector (Jl) pins <37:36>. The KN210 ROM programs use 
BDCODE <01:00> to determine the power up mode. 



3.7.2 Diagnostic LED Register 

The diagnostic LED register (DLEDR), R3000 address 1014 0030 16 ; 
diagnostic processor address 2014 0030 i6, is implemented in the SSC and 
contains four read/write bits that control the external LED display. A in 
a bit lights the corresponding LED; all four bits are cleared on power-up 
and the negation of DCOK when SCR<7> is clear to provide a power-up 
lamp test (Figure 3-32). 



31 



4321 



MBZ 



DSPL 



MA- X1 +47-87 



Figure 3-32 Diagnostic LED Register 



Data Bit Definition 



DLEDR<31:4> Unused. Read as zeros, must be written as zeros. 

DLEDR<3:0> (DSPL) Display <3:0>. Read/Write. These four bits update 
an external LED display. Writing a to a bit lights the 
corresponding LED. Writing a 1 to a bit turns its LED off. 
The display bits are cleared (all LEDs are lit) on power-up and 
the negation of DCOK when SCR<7> is clear. 



3—52 Architecture 



3.7.3 ROM Memory 

The KN210 supports 256 Kbytes of ROM memory for storing code (128 
Kbytes per processor) for board initialization, board self-tests, and boot 
code. ROM memory may be accessed through byte, halfword, word and 
longword references. CDAL bus parity is neither checked nor generated 
on ROM references. 

NOTE 

The ROM size must be set in the SSC configuration register before 
attempting references outside the first 8 Kbyte block of the local 
ROM space. 

3.7.3.1 ROM Socket 

The KN210 provides two 40-pin ROM sockets to accept two 64K x 16-bit 
EPROMs or ROMs. 

3.7.3.2 ROM Address Space 

Two 64 Kbytes by 16-bit ROMs reside on the KN210 CPU module. One 
ROM is dedicated to each of the processors and cannot be accessed by the 
other. 

The R3000 ROM address space goes from 1FC0 0000 to 1FC1 FFFF. 

Writes to this address space by the R3000 will result in a Memerr 
Interrupt INT<3>. 

The diagnostic processor ROM is located at 2004 0000 to 2005 FFFF in 
halt mode and 2006 0000 to 2007 FFFF in run mode. Note that the run 
mode ROM space reads exactly the same ROM code as the halt mode 
ROM space. 

Writes to either of these address spaces by the diagnostic processor will 
result in a machine check. 

Power-Up Modes 

The boot and diagnostic ROM programs use boot and diagnostic code 
<1:0> to determine the power-up modes as described in Section 3.7.1. 



Architecture 3-53 



3.7.4 Battery Backed-Up RAM 

The KN210 contains 1 Kbyte of battery backed-up static RAM, for use as 
a console "scratchpad." The power for the RAM is provided through pins 
38 (VBAT H) and 20, 18, 16-13, 10-8, 6-3 (GND) of the 40-pin connector. 

The RAM is organized as a 256 x 32-bit array. The array appears in a 1 
Kbyte block of R3000 address space at 1014 0400-1014 07FF and in the 
diagnostic processor I/O page at addresses 2014 0400-2014 07FF. 

This array is not protected by parity, and CDAL bus parity is neither 
checked nor generated on reads or writes to this RAM. 

3.7.5 KN210 Initialization 

There are three kinds of hardware initialization: power-up initialization, 
processor initialization, and I/O bus initialization. 

3.7.5.1 Power-Up Initialization 

Power-up initialization is the result of the restoration of power and 
includes a hardware reset, a processor initialization and an I/O bus 
initialization. 

3.7.5.2 Hardware Reset 

A KN210 hardware reset occurs on power-up, the negation of DCOK when 
SCR<7> is clear, on the assertion of BINIT on the Q22-bus. A hardware 
reset causes the hardware halt procedure to be initiated with a diagnostic 
processor halt code of 03. It also initializes some IPRs and most I/O page 
registers to a known state. The effect a hardware reset has on I/O space 
registers is documented in the description of the register. 

3.7.5.3 I/O Bus Initialization 

An I/O bus initialization occurs on power-up, the negation of DCOK, or as 
the result of an R3000 write to the IORESET register, or of a diagnostic 
processor MTPR to IPR 55 (IORESET), or a diagnostic processor write to 
the IORESET register (2014 00DC). An I/O bus initialization clears the 
IPCR and DSER, and causes the Q22-bus interface to acquire both the 
CDAL and Q22-bus, then assert the Q22-bus BINIT signal. 

I/O Bus Reset Register 

The I/O bus reset register (IORESET) is implemented in the SSC. 



3—54 Architecture 



3.7.5.4 Processor Initialization 

A processor initialization occurs on power-up, the negation of DC OK, the 
assertion of BINIT as the result of a console INITIALIZE command, and 
after a halt caused by a diagnostic processor error condition. 

KN210 firmware must configure main memory, the local I/O page, and the 
Q22-bus map during a processor initialization. 

3.7.6 Select Processor Register 

The select processor register (SPR) determines which processor will 
control the memory and I/O subsystems. This register is write only, 
reading will produce unpredictable results. The format for the select 
processor register, (diagnostic processor address 2008 4008; R3000 address 
1008 4008), is shown in Figure 3-33. 

31 30 



SP 



UNDEFINED 



MA-X0612-BS 



Figure 3-33 Select Processor Register 



Data Bit 



Definition 



SPR<31> (SP) Select processor. Write ONLY. When set to one (1) enables 

R3000 operation. When clear (0) enables diagnostic processor 
operation. The R3000 is disabled by stalling memory operations 
while the SP bit is clear. The diagnostic processor is disabled 
by requesting a DMG and holding the bus while the SP bit is 
set. 

SPR<30:0> Undefined. Reading will produce unpredictable results. 



Architecture 3-55 



3.7.7 Write Error Address Register 

The write error address register (WEAR) is a 32-bit register, located 
at 1700 0000, that latches the bus address for the first R3000 write 
cycle producing a bus error. The causes for this bus error on writes 
are accessing non existent memory, doing a masked write to a memory 
location with incorrect ECC check bits, or any write to the CQBIC that 
results in an error. Any subsequent write which causes a bus error will 
not change the WEAR value until the MER0 bit has been cleared in the 
ISR register. The WEAR cannot be accessed by the diagnostic processor, 
and is undefined on powerup. 

3.8 Q22-bus Interface 

The KN210 includes a Q22-bus interface implemented through a single 
VLSI chip called the CQBIC. It contains a CDAL bus to Q22-bus interface 
that supports the following functions: 

• A programmable mapping function (scatter-gather map) for 
translating 22-bit, Q22-bus addresses into 29-bit CDAL bus addresses 
that allows any page in the Q22-bus memory space to be mapped to 
any page in main memory. 

• A direct mapping function for translating 29-bit CDAL addresses 
in the local Q22-bus address space and local Q22-bus I/O page into 
22-bit, Q22-bus addresses. 

• Masked and unmasked word reads and writes from the CPU to the 
Q22-bus memory and I/O space and the Q22-bus interface registers. 
Word reads and writes of the local Q22-bus memory space are buffered 
and translated into two-word, block mode, transfers on the Q22-bus. 
Word reads and writes of the local Q22-bus I/O space are buffered and 
i>i~cu!i5ia. i/Svx m^o i/WG, smgiS-wcrvi transfers on ine x{ZZ~dus> 

• Up to sixteen-word, block mode, writes from the Q22-bus to main 
memory. These words are buffered then transferred to main memory 
using two asynchronous DMA fourword transfers. For block mode 
writes of less than sixteen words, the words are buffered and 
transferred to main memory using the most efficient combination 

of fourword, twoword, and word asynchronous DMA transfers. 



3—56 Architecture 



The maximum write bandwidth for block mode references is 3.3 
Mbytes per second. Block mode reads of main memory from the Q22- 
bus cause the Q22-bus interface to perform an asynchronous DMA 
twoword read of main memory and buffer all four words, so that on 
block mode reads, the next three words of the block mode read can 
be delivered without any additional CDAL bus cycles. The maximum 
read bandwidth for Q22-bus block mode references is 2.4 Mbytes per 
second. Q22-bus burst mode DMA transfers result in single-word 
reads and writes of main memory. 

• Transfers from the CPU to the local Q22-bus memory space, that 
result in the Q22-bus map translating the address back into main 
memory (local-miss, global-hit transactions). 

The Q22-bus interface contains several registers for Q22-bus control and 
configuration, and error reporting. 

The interface also contains Q22-bus interrupt arbitration logic that 
recognizes Q22-bus interrupt requests BR7-BR4 and translates them 
into CPU interrupts at levels 17-14. 

The Q22-bus interface detects Q22-bus no sack timeouts, Q22-bus 
interrupt acknowledge timeouts, Q22-bus non-existent memory timeouts, 
main memory errors on DMA accesses from the Q22-bus and Q22-bus 
parity errors. 

3.8.1 Q22-bus to Main Memory Address Translation 

On DMA references to main memory, the 22-bit, Q22-bus address must be 
translated into a 29-bit main memory address. This translation process 
is performed by the Q22-bus interface by using the Q22-bus map. This 
map contains 8192 mapping registers, (one for each page in the Q22-bus 
memory space), each of which can map a page (512 bytes) of the Q22-bus 
memory address space into any of the 128K pages in main memory. Since 
local I/O space addresses cannot be mapped to Q22-bus pages, the local 
I/O page is inaccessible to devices on the Q22-bus. 

Q22-bus addresses are translated to main memory addresses as shown in 
Figure 3-34. 



Architecture 3-57 



31 




9 


8 





Q22-bus ADDRESS 






I 









EXTRACT TO SELECT 
MAP REGISTER 



r 



_i 



31 



MAPPING REGISTER 



19 



28 



9 I 8 



PHYSICAL ADDRESS OF MAIN MEMORY 



Figure 3-34 Q22-bus to Main Memory Address Translation 

At power up time, the Q22-bus map registers, including the valid bits, 
are undefined. External access to main memory is disabled as long as the 
interprocessor communication register LM EAE bit is cleared. The Q22- 
bus interface monitors each Q22-bus cycle and responds if the following 
three conditions are met: 

1. The interprocessor communication register LM EAE bit is set. 

2. The valid bit of the selected mapping register is set. 

3. During read operations, the mapping register must map into existent 
main memory, or a Q22-bus timeout occurs. (During write operations, 
the Q22-bus interface returns Q22-bus BRPLY before checking for 
existent local memory; the response depends only on conditions 1 and 
2 above.) 

NOTE 

In the case of local-miss, global-hit, the state of the LM EAE bit is 

ignored. 

If the map cache does not contain the needed Q22-bus map register, then 
the Q22-bus interface will perform an asychronous DMA read of the 
Q22-bus map register before proceeding with the Q22-bus DMA transfer. 



3—58 Architecture 



3.8.1.1 Q22-bus Map Registers 

The Q22-bus map contains 8192 registers (QMRs) that control the 
mapping of Q22-bus addresses into main memory. Each register maps 
a page of the Q22-bus memory space into a page of main memory 
(Table 3—10). These registers are implemented in a 32 Kbyte block of 
main memory, but are accessed through the CQBIC chip through a block 
of addresses in the I/O page. 

The local I/O space address of each register was chosen so that register 
address bits <14:2> are identical to Q22-bus address bits <21:9> of the 
Q22-bus page which the register maps. The Q22-bus map registers 
(QMRs) have the format shown in Figure 3-35. 



31 30 



20 19 



V 


MBZ 


A28 - A9 



MA-XH50-87 



Figure 3-35 Q22-bus Map Registers 



Data Bit 



Definition 



QMR<31> (V) Valid. Read/Write. When a Q22-bus map register is selected 

by bits <21:9> of the Q22-bus address, the valid bit determines 
whether mapping is enabled for that Q22-bus page. If the 
valid bit is set, the mapping is enabled, and Q22-bus addresses 
within the page controlled by the register are mapped into the 
main memory page determined by bits <28:9>. If the valid 
bit is clear, the mapping register is disabled, and the Q22-bus 
interface does not respond to addresses within that page. This 
bit is undefined on power-up and the negation of DCOK when 
the processor is halted. 

QMR<30:20> Unused. These bits always read as zero and must be written as 
zero. 

QMR<19:0> (A28-A9) Address bits <28:9>. Read/Write. When a Q22-bus 

map register is selected by a Q22-bus address, and if that 
register's valid bit is set, then these 20 bits are used as main 
memory address bits <28:9>. Q22-bus address bits <8:0> 
are used as main memory address bits <8:0>. These bits are 
undefined on power-up and the negation of DCOK when the 
processor is halted. 



Architecture 3-59 



Table 3-10 


Q22-bus Map 






Register 
Address 


Q22-bus Addresses 
Mapped (Hex) 


Q22-bus Addresses Mapped 
(Octal) 


1008 8000 


00 0000 - 00 01FF 


00 000 000 


- 00 000 777 


1008 8004 


00 0200 - 00 03FF 


00 001 000 


- 00 001 777 


1008 8008 


00 0400 - 00 05FF 


00 002 000 


- 00 002 777 


1008 800C 


00 0600 - 00 07FF 


00 003 000 


- 00 003 777 


1008 8010 


00 0800 - 00 09FF 


00 004 000 


■ 00 004 777 


1008 8014 


00 0AO0 - 00 OBFF 


00 005 000 


- 00 005 777 


1008 8018 


00 OCOO - 00 ODFF 


00 006 000 


- 00 006 777 


1008 801C 


00 OEOO - 00 OFFF 


00 007 000 


- 00 007 777 



1008 FFFO 
1008 FFF4 
1008 FFF8 
1008 FFFC 



3F F800 - 3F F9FF 
3F FAOO - 3F FBFF 
3F FCOO - 3F FDFF 
3F FEOO - 3F FFFF 



17 774 000 - 17 774 777 
17 775 000 - 17 775 777 
17 776 000 - 17 776 777 
17 776 000 - 17 777 777 



3.8.1.2 Accessing the Q22-bus Map Registers 

Although the CPU accesses the Q22-bus map registers through aligned, 
masked word references, to the local I/O page (R3000 addresses 1008 
8000 i6 through 1008 FFFC i 6 ; diagnostic processor addresses 2008 8000 
16 through 2008 FFFC i6), the map actually resides in a 32 Kbyte block 
of main memory. The starting address of this block is controlled by the 
contents of the Q22-bus map base register. The Q22-bus interface also 
contains a 16-entry, fully associative, Q22-bus map cache to reduce the 
number of main memory accesses required for address translation. 

NOTE 

The system software must protect the pages of memory that 
contain the Q22-bus map from direct accesses that will corrupt 
the map or cause the entries in the Q22-bus map cache to become 
stale. Either of these conditions will result in the incorrect 
operation of the mapping function. 

When the CPU accesses the Q22-bus map through the local I/O page 
addresses, the Q22-bus interface reads or writes the map in main memory. 
The Q22-bus interface does not have to gain Q22-bus mastership when 
accessing the Q22-bus map. Since these addresses are in the local I/O 
space, they are not accessible from the Q22-bus. 



3—60 Architecture 



On a Q22-bus map read by the CPU, the Q22-bus interface decodes 
the local I/O space address (2008 8000 - 2008 FFFC for the diagnostic 
processor; 1008 8000 - 1008 FFFC for the R3000). If the register is in 
the Q22-bus map cache, the Q22-bus interface will internally resolve any 
conflicts between CPU and Q22-bus transactions (if both are attempting 
to access the Q22-bus map cache entries at the same time), then return 
the data. If the map register is not in the map cache, the Q22-bus 
interface will force the CPU to retry, acquire the CDAL bus, perform an 
asynchronous DMA read of the map register. On completion of the read, 
the CPU is provided with the data when its read operation is retried. A 
map read by the CPU does not cause the register that was read to be 
stored in the map cache. 

On a Q22-bus map write by the CPU, the Q22-bus interface latches the 
data, then on the completion of the CPU write, acquires the CDAL bus 
and performs an asynchronous DMA write to the map register. If the 
map register is in the Q22-bus map cache, then the Cam Valid bit for that 
entry will be cleared to prevent the entry from becoming stale. A Q22-bus 
map write by the CPU does not update any cached copies of the Q22-bus 
map register. 

3.8.1.3 Q22-bus Map Cache 

To speed up the process of translating Q22-bus address to main memory 
addresses, the Q22-bus interface utilizes a fully associative, sixteen entry, 
Q22-bus map cache, which is implemented in the CQBIC chip. 

If a DMA transfer ends on a page boundary, the Q22-bus interface will 
prefetch the mapping register required to translate the next page and 
load it into the cache, before starting a new DMA transfer. This allows 
Q22-bus block mode DMA transfers that cross page boundaries to proceed 
without delay. The replacement algorithm for updating the Q22-bus map 
cache is FIFO. 

The cached copy of the Q22-bus map register is used for the address 
translation process. If the required map entry for a Q22-bus address 
(as determined by bits <21:9> of the Q22-bus address) is not in the map 
cache, then the Q22-bus interface uses the contents of the map base 
register to access main memory and retrieve the required entry. After 
obtaining the entry from main memory, the valid bit is checked. If it is 
set, the entry is stored in the cache and the Q22-bus cycle continues. 

The format of a Q22-bus map cache entry is as shown in Figure 3-36. 



Architecture 3-61 



33 32 




20 


19 









CV 


Q22-bus ADR<21:9> 




A28 - 


- A9 





MA-X1 +51-87 



Figure 3-36 Q22-bus Map Cache Entry 



Data Bit 



Definition 



CQMR<33> (Cam Valid). When a mapping register is selected by a Q22-bus 

address, the Cam Valid bit determines whether the cached copy 
of the mapping register for that address is valid. If the Cam 
Valid bit is set, the mapping register is enabled, and addresses 
within that page can be mapped. If the Cam Valid bit is clear, 
the Q22-bus interface must read the map in local memory to 
determine if the mapping register is enabled. This bit is cleared 
on power-up, the negation of DCOK when the processor is 
halted, by setting the QMCIA (Q22-bus map cache invalidate 
all) bit in the interprocessor communication register, on writes 
to the IORESET register, by a write to the Q22-bus map base 
register, or by writing to the QMR that is being cached. 

CQMR<32:20> (QBUS ADR). These bits contain the Q22-bus address bits 
<21:9> of the page that this entry maps. This is the content 
addressable field of the 16 entry cache for determining if the 
map register for a particular Q22-bus address is in the map 
cache. These bits are undefined on power-up. 

CQMR<19:0> (Address bits A28-A9). When a mapping register is selected by 
a Q22-bus address, and if that register's Cam Valid bit is set, 
then these 20 bits are used as main memory address bits 28 
through 9. Q22-bus address bits 8 through are used as local 
memory address bits 8 through 0. These bits are undefined on 
power-up. 



3—62 Architecture 



3.8.2 CDAL Bus to Q22-bus Address Translation 

CDAL bus addresses within the local Q22-bus I/O space, addresses (2000 
0000 - 2000 1FFF 16 for the diagnostic processor; 1000 0000 - 1000 1FFF 
16 for the R3000), are translated into Q22-bus I/O space addresses by- 
using bits <12:0> of the CDAL address as bits <12:0> of the Q22-bus 
address and asserting BBS7. Q22-bus address bits <21:13> are driven as 
zeros. 

CDAL bus addresses within the local Q22-bus memory space, addresses 
(3000 0000 - 303F FFFF 16 for the diagnostic processor; 1400 0000 - 
143F FFFF 16 for the R3000), are translated into Q22-bus memory space 
addresses by using bits <21:0> of the CDAL address as bits <21:0> of the 
Q22-bus address. 

3.8.3 Interprocessor Communication Register 

The interprocessor communication register (IPCR), diagnostic processor 
address 2000 1F40 i6 ; R3000 address 1000 1F40 16 , is a 16-bit register 
which resides in the Q22-bus I/O page address space and can be accessed 
by any device which can become Q22-bus master (including the KN210 
itself). The IPCR, implemented in the CQBIC chip, is byte accessible, 
meaning that a write byte instruction can write to either the low or high 
byte without affecting the other byte. 

The IPCR also appears at Q22-bus address 17 777 500 (Figure 3-37). 



151413 9 


8 7 


3 5 4 10 






MBZ 




MBZ 




DMA QME 










QMCIA 
RESERVEC 


) 




MBZ 




RESERVED 




LM EAE 




RESERVED 





MA-X1 452-87 



Figure 3-37 The Interprocessor Communication Register 



Architecture 3-63 



Data Bit 



Definition 



IPCR<15> (DMA QME) DMA Q22-bus address space memory error. 

Read/Write to clear. This bit indicates that an error occurred 
when a Q22-bus device was attempting to read main memory. It 
is set if DMA system error register bit DSER<4> (main memory 
error) is set, or the CDAL bus timer expires. The main memory 
error bit indicates that an uncorrectable error occurred when 
an external device (or CPU) was accessing the KN210 local 
memory. The CDAL bus timer expiring indicates that the memory 
controller did not respond when the Q22-bus interface initiated a 
DMA transfer. This bit is cleared by writing a 1 to it, on power- 
up, by the negation of DCOK when the processor is halted, by 
writes to the IORESET register, and whenever DSER<4> is 
cleared. 

(QMCIA) Q22-bus invalidate all. Write only. Writing a 1 to this 
bit clears the Cam Valid bits in the cached copy of the map. This 
bit always reads as zero. Writing a has no effect. 

(Unused) Read as zeros. Must be written as zeros. 

Reserved for Digital use. 

Unused. Read as zero. Must be written as zero. 

Reserved for Digital use. 

(LM EAE) Local memory external access enable. Read/Write when 
the KN210 is Q22-bus master. Read only when another device is 
Q22-bus master. When set, this bit enables external access to 
local memory (through the Q22-bus map). Cleared on power-up 
and by the negation of DCOK when the processor is halted. 

IPCR<4:1> Unused. Read as zeros. Must be written as zeros. 

IPCR<0> Reserved for Digital use. 



IPCR<14> 

IPCR<13:9> 

IPCR<8> 

IPCR<7> 

IPCR<6> 

IPCR<5> 



3.8.4 Q22-bus Interrupt Handling 

The KN210 responds to interrupt requests BR7-4 with the standard Q22- 
bus interrupt acknowledge protocol (DIN followed by IAK). The console 
serial line unit, the programmable timers, and the interprocessor doorbell 
request interrupts at IPL 14 and have priority over all Q22-bus BR4 
interrupt requests. 



3—64 Architecture 



3.8.5 Configuring the Q22-bus Map 

The KN210 implements the Q22-bus map in an 8K word (32 Kbyte) 
block of main memory. This map must be configured by the KN210 
firmware during a processor initialization by writing the base address 
of the uppermost 32 Kbyte block of good main memory into the Q22-bus 
map base register. The base of this map must be located on a 32 Kbyte 
boundary. 

NOTE 

This 32 Kbyte block of main memory must be protected by 
the system software. The only access to the map should be 
through local I/O page addresses (2008 80 00 - 2 008 FFFC 16 for 
the diagnostic processor; 1008 8000 - 1008 FFFC 16 for the R3000). 

3.8.5.1 Q22-bus Map Base Address Register 

The Q22-bus map base address register (QBMBR), diagnostic processor 
address 2008 0010 i6 ; R3000 address 1008 0010 16 , controls the main 
memory location of the 32 Kbyte block of Q22-bus map registers. 

This read/write register is accessible by the CPU on a word boundary 
only. Bits <31:29,14:0> are unused and should be written as zero and will 
return zero when read. 

A write to the map base register will flush the Q22-bus map cache by 
clearing the Cam Valid bits in all the entries. 

The contents of this register are undefined on power up and the negation 
of DCOK when the processor is halted, and are not affected by BINIT 
being asserted on the Q22-bus (Figure 3-38). 



31 29 28 15 14 





I 


MAP BASE 


MBZ 



MA-X1 +63-87 



Figure 3-38 Q22-bus Map Base Address Register 



Architecture 3—65 



3.8.6 System Configuration Register 

The system configuration register (SCR), diagnostic processor address 
2008 0000 i 6 ; R3000 address 1008 0000 i 6 , contains a BHALT enable bit 
and a power OK flag. 

The system configuration register (SCR) is word, halfword, and byte 
accessible. Programmable option fields are cleared on power-up and by 
the negation of DCOK when the processor is halted. The format of the 
SCR register is shown in Figure 3-39. 



31 



15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 



MBZ 



POK 



BHALT ENB 



RESERVED 



MBZ MBZ MBZ 



ACTION ON DCOK NEGATION 



RESERVED 



MUST BE ZERO 



MA- XI 454-87 



Figure 3-39 System Configuration Register 



Data Bit 



Definition 



SCR<31:16> Unused. Read as zero. Must be written as zero. 

SCR<15> (POK) Power OK Read only. Writes have no effect. This bit is set 

if the Q22-bus BPOK signal is asserted and clear if it is negated. 
This bit is cleared on power-up and by the negation of DCOK 
when the processor is halted. 

SCR<14> (BHALT EN) BHALT enable. Read/Write. This bit controls the 

effect the Q22-bus BHALT signal has on the CPU. When set, 
asserting the Q22-bus BHALT signal will halt the CPU and assert 
DSER<15>. When cleared, the Q22-bus BHALT signal will have 
no effect. This bit is cleared on power-up and by the negation of 
DCOK when the processor is halted. 

SCR<13:11> Unused. Read as zero. Must be written as zero. 

SCR<10> Reserved for Digital use. 



3-66 Architecture 



Data Bit 



Definition 



SCR<9:8> Unused. Read as zero. Must be written as zero. 

SCR<7> (ACTION ON DCOK NEGATION) Read/Write. When cleared, the 

Q22-bus interface asserts SYSRESET (causing a hardware reset 
of the board and control to be passed to the resident firmware 
through the hardware halt procedure with a halt code of 3) 
when DCOK is negated on the Q22-bus. When set, the Q22-bus 
interface asserts HALTIN (causing control to be passed to the 
resident firmware through the hardware halt procedure with a 
halt code of 2) when DCOK is negated on the Q22-bus. Cleared on 
power-up and the negation of DCOK when the processor is halted. 

SCR<6:4> Unused. Read as zero. Must be written as zero. 

SCR<3:1> Reserved for Digital use. 

SCR<0> Unused. Read as 0. Must be written as 0. 



3.8.7 DMA System Error Register 

The DMA system error register (DSER), diagnostic processor address 2008 
0004 i6; R3000 address 1008 0004 i&, is one of three registers associated 
with Q22-bus interface error reporting. 

The DMA system error register is implemented in the CQBIC chip, and 
logs main memory errors on DMA transfers, Q22-bus parity errors, Q22- 
bus non-existent memory errors, and Q22-bus no-grant errors. The Q22- 
bus error address register contains the address of the page in Q22-bus 
space which caused a parity error during an access by the local processor. 

The DMA error address register contains the address of the page in local 
memory which caused a memory error during an access by an external 
device or the processor during a local miss global hit transaction. An 
access by the local processor which the Q22-bus interface maps into main 
memory will provide error status to the processor when the processor does 
a RETRY for a READ local miss-global hit, or by an interrupt in the case 
of a local-miss global-hit write. 

The DSER is a word, halfword, or byte accessable read/write register 
available to the local processor. The bits in this register are cleared to 
on power-up, by the negation of DCOK when the processor is halted, 
and by writes to the IORESET register. All bits are set to 1 to record the 
occurrence of an event. They are cleared by writing a 1, writing zeros has 
no effect (Figure 3-40). 



Architecture 3-67 



31 



15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 



MBZ 



Q22-bus BHALT DETECTED 



Q22-bus DCOK NEGATION DETECTED 



MBZ 



Q22-bus NXM 



MUST BE ZERO 



Q22-bus PE 



MAIN MEMORY ERROR 



LOST ERROR BIT 



NO GRANT 



MUST BE ZERO 



DMA NXM 



MA-X1 455-87 



Figure 3-40 DMA System Error Register 



Data Bit 



Definition 



DSER<31:16> Unused. Read as 0. Must be written as 0. 

DSER<15> Q22-bus BHALT detected. Read/Write to clear. Set when the Q22- 
bus interface detects that the Q22-bus BHALT line was asserted 
and SCR<14> (BHALT ENABLE) is set. Cleared by writing a 1, 
writes to the IORESET register, on power-up and the negation of 
DCOK when the processor is halted. 

DSER<14> Q22-bus DCOK negation detected. Read/Write to clear. Set when 
the Q22-bus interface detects the negation of DCOK on the Q22- 
bus and SCR<7> (action on DCOK negation) is set. Cleared by 
writing a 1, writes to the IORESET register, on power-up and the 
negation of DCOK when the processor is halted. 

DSER<13:8> Unused. Read as zero. Must be written as zero. 

DSER<7> Master DMA NXM. Read/Write to clear. This bit is set when the 

CPU performs a demand Q22-bus read cycle or write cycle that 
does not reply after 10 us. During interrupt acknowledge cycles, 
or request read cycles, this bit is not set. It is cleared by writing 
a 1, on power-up, by the negation of DCOK when the processor is 
halted and by writes to the IORESET register. 



3-68 Architecture 



Data Bit 



Definition 



DSER<6> Unused. Read as zero. Must be written as zero. 

DSER<5> Q22-bus parity error. Read/Write to clear. This bit is set when 

the CPU performs a Q22-bus demand read cycle which returns a 
parity error. During interrupt acknowledge cycles or request read 
cycles, this bit is not set. It is cleared by writing a 1, on power-up, 
by the negation of DCOK when the processor is halted and by 
writes .to the IORESET register. 

DSER<4> Main memory error. Read/Write to clear. This bit is set if an 

external Q22-bus device or local miss global hit receives a memory 
error while reading local memory. The IPCR<15> reports the 
memory error to the external Q22-bus device. It is cleared by 
writing a 1, on power-up, by the negation of DCOK when the 
processor is halted and by writes to the IORESET register. 

DSER<3> Lost error. Read/Write to clear. This bit indicates that an error 

address has been lost because of DSER<7,5,4,0> having been 
previously set and a subsequent error of either type occurs 
which would have normally captured an address and set either 
DSER<7,5,4,0> flag. It is cleared by writing a 1, on power-up, by 
the negation of DCOK when the processor is halted and by writes 
to the IORESET register. 

DSER<2> No grant timeout. Read/Write to clear. This bit is set if the Q22- 

bus does not return a bus grant within 10ms of the bus request 
from a CPU demand read cycle, or write cycle. During interrupt 
acknowledge or request read cycles this bit is not set. It is cleared 
by writing a 1, on power-up, by the negation of DCOK when the 
processor is halted and by writes to the IORESET register. 

DSER<1> Unused. Read as zero. Must be written as zero. 

DSER<0> DMA NXM. Read/Write to clear. This bit is set on a DMA transfer 

to a non-existent main memory location. This includes local-miss 
global-hit cycles and map accesses to non-existent memory. It is 
cleared by writing a 1, on power-up, by the negation of DCOK 
when the processor is halted and by writes to the IORESET 
register. 



Architecture 3-69 



3.8.8 Q22-bus Error Address Register 

The Q22-bns error address register (QBEAR), diagnostic processor address 
2008 0008 i 6 ; R3000 address 1008 0008 16 , is a read only, word accessible 
register which is implemented in the CQBIC chip. Its contents are valid 
only if DSER <5> (Q22-bus parity error) is set or if DSER<7> (Q22-bus 
timeout) is set. 

Reading this register when DSER<5> and DSER<7> are clear will return 
undefined results. Additional Q22-bus parity errors that could have set 
DSER<5> or Q22-bus timeout errors that could have caused DSER<7> to 
set, will cause DSER<3> to set. 

The QBEAR contains the address of the page in Q22-bus space which 
caused a parity error during an access by the on-board CPU which set 
DSER<5> or a master timeout which set DSER<7>. 

Q22-bus address bits <21:9> are loaded into QBEAR bits <12:0>. QBEAR 
bits <31:13> always read as zeros (Figure 3—41). 



31 





13 


12 







MBZ 


Q22-bus ADDRESS BITS <21:9> 



MA-X1 456-87 



Figure 3-41 Q22-bus Error Address Register 

NOTE 

This is a read only register, if a write is attempted a machine 

check will be generated. 

3.8.9 DMA Error Address Register 

The DMA error address register (DEAR), diagnostic processor address 
2008 000C i 6 ; R3000 address 1008 000C 16 , is a read only, word accessible 
register which is implemented in the CQBIC chip. It contains valid 
information only when DSER<4> (main memory error) is set or when 
DSER<0> (DMA NXM) is set. Reading this register when DSER<4> and 
DSER<0> are clear will return undefined data. 

The DEAR contains the map translated address of the page in local 
memory which caused a memory error or non existent memory error 
during an access by an external device or the Q22-bus interface for the 
CPU during a local-miss global-hit transaction or Q22-bus map access. 



3—70 Architecture 



The contents of this register are latched when DSER<4> or DSER<0> is 
set. Additional main memory errors or non-existent memory errors have 
no effect on the DEAR until software clears DSER<4> and DSER<0>. 

Mapped Q22-bus address bits <28:9> are loaded into DEAR bits <19:0>. 
DEAR bits <31:20> always read as zeros (Figure 3—42). 



31 20 19 



MBZ 



MAPPED Q22-bus ADDRESS BITS <28:9> 



MA-X1 457-87 



Figure 3-42 DMA Error Address Register 

NOTE 

This is a read only register, if a write is attempted a machine 

check will be generated. 

3.8.10 Error Handling 

The Q22-bus interface does not generate or check CDAL bus parity. 

The Q22-bus interface checks all CPU references to Q22-bus memory 
and I/O spaces to ensure that nothing but masked and unmasked 
word accesses are attempted. Any other type of reference will cause a 
diagnostic processor machine check abort to be initiated, an R3000 bus 
error exception on reads, and an IRQ3 interrupt on writes. 

The Q22-bus interface maintains several timers to prevent incomplete 
accesses from hanging the system indefinitely. These include a 10 us 
non-existent memory timer for accesses to the Q22-bus memory and I/O 
spaces, a 10 us no sack timer for acknowledgement of Q22-bus DMA 
grants, and a 10 ms no grant timer for acquiring the Q22-bus. 

If there is a non-existent memory (NXM) error (10 us timeout) while 
accessing the Q22-bus on a demand read reference, the associated row 
in the diagnostic processor cache is invalidated; DSER<7> is set; the 
address of the Q22-bus page being accessed is captured in QBEAR<12:0>; 
a diagnostic processor machine check abort is initiated; and an R3000 bus 
exception is generated. 

If there is a NXM error on a prefetch read, or an interrupt acknowledge 
vector read, then the prefetch or interrupt acknowledge reference is 
aborted but no information is captured and no machine check occurs. 



Architecture 3-71 



If there is a NXM error on a masked write reference, then DSER<7> 
is set, the address of the Q22-bus page being accessed is captured in 
QBEAR<12:0>, a diagnostic processor interrupt is generated at IPL ID 
through vector 60 i6, and an R3000 IRQ3 interrupt is generated. 

If the Q22-bus interface does not receive an acknowledgement within 
10 pis after it has granted the Q22-bus, then the grant is withdrawn, no 
errors are reported, and the Q22-bus interface waits 500 ns to clear the 
Q22-bus grant daisy chain before beginning arbitration again. 

If the Q22-bus interface tries to obtain Q22-bus mastership on a CPU 
demand read reference and does not obtain it within 10 ms, then the 
associated row in the cache is invalidated, DSER<2> is set, and a machine 
check abort is initiated. 

The Q22-bus interface also monitors Q22-bus signals BDAL<17:16> while 
reading information over the Q22-bus so that parity errors detected by 
the device being read from are recognized. 

If a parity error is detected by another Q22-bus device on a diagnostic 
processor demand read reference to Q22-bus memory or I/O space, then 
the associated row in the diagnostic processor cache is invalidated, 
DSER<5> is set, the address of the Q22-bus page being accessed is 
captured in QBEAR<12:0>, and a machine check abort is initiated. 

If a parity error is detected by another Q22-bus device on a prefetch 
request read by the diagnostic processor, the prefetch is aborted, the 
associated row in the diagnostic processor cache is invalidated, DSER<5> 
is set, the address of the Q22-bus page being accessed is captured in 
QBEAR<12:0>, but no machine check is generated. 

The Q22-bus interface also monitors the backplane BPOK signal to detect 
power failures. If BPOK is negated on the Q22-bus, a power fail trap is 
generated, and the diagnostic processor traps through vector 0C i6- The 
R3000 gets an IRQ 3 interrupt request. The state of the Q22-bus BPOK 
signal can be read from SCR<15>. The Q22-bus interface continues to 
operate after generating the powerfail trap, until DCOK is negated. 



3—72 Architecture 



3.9 Network Interface 

The KN210 includes a network interface implemented by the LANCE 
chip, a 32 x 8 bit ROM and four 32K x 8 static RAMs, and located on the 
KN210 I/O module. When used in conjunction with the H3602-SA, this 
network interface allows the KN210 to be connected to either a thinwire 
or standard Ethernet network. It supports the Ethernet data link layer. 

The network interface includes a word-wide 128 Kbyte NI buffer (the 
four 32 x 8 static RAMs) as well as four registers for control and status 
reporting, a DMA controller, a 24 word transmit silo and a 24 word 
receive silo (all resident in the LANCE chip). The DMA controller reads 
control information and writes status information from/to the 128 Kbyte 
NI buffer as well as transfers data between the NI buffer and either the 
transmit or receive silo. The DMA controller can perform bursts of up to 
eight halfword references. 

Each reference (between the LANCE and the NI buffer) takes 600 ns and 
contains either a byte or word of data, resulting in a maximum burst 
duration of 4.8 us. The minimum time between bus requests is 8 us. 

The CPU moves data between main memory and the NI buffer through 
programmed transfers. 

3.9.1 Ethernet Overview 

Ethernet is a serial bus that can support up to 1,024 nodes with a 
maximum separation of 2.8 km (1.7 miles). Data is passed over the 
Ethernet in Manchester encoded format at a rate of 10 million bits per 
second in variable-length packets. Each packet has the format shown in 
Figure 3-43. 

The minimum size of a packet is 64 bytes, which implies a minimum data 
length of 46 bytes. Packets shorter than this are called runt packets and 
are treated as erroneous when received by the network controller. 



Architecture 3—73 



6 BYTES 



$ BYTES 



2 BYTES 



46 TO 1500 BYTES 



DESTINATION ADDRESS 



SOURCE ADDRESS 



TYPE 



4 BYTES 



DATA 



CRC CHECK CODE 



MA-X0045-8S 



Figure 3-43 Ethernet Data Packet Format 

All nodes on the Ethernet have equal priority. The technique used to 
control access to the bus is carrier sense, multiple access, with collision 
detection (CSMA/CD). To access the bus, devices must first wait for the 
bus to clear (no carrier sensed). Once the bus is clear, all devices that 
want to access the bus have equal priority (multi-access), so they all 
attempt to transmit. After starting transmission, devices must monitor 
the bus for collisions (collision detection). If no collision is detected, the 
device may continue with transmission. If a collision is detected, then 
the device waits for a random amount of time and repeats the access 
sequence. 



3—74 Architecture 



Ethernet allows point to point communication between two devices, 
as well as simultaneous communication between multiple devices. 
Tb support these two modes of communication, there are two types 
of network addresses, physical and multicast. These two types of 
addresses are both 48 bits (6 bytes) long and are described below. 

A Physical address is the unique address associated with a particular 
station on the Ethernet, which should be distinct from the physical 
address of any other station on any other Ethernet. 

A Multicast address is a multi-destination address associated with one 
or more stations on a given Ethernet (sometimes called a logical address). 

Further, there are two kinds of multicast addresses, the Multicast-group 
address and the Broadcast address. 

The Multicast-group address is an address associated by higher-level 
convention with a group of logically related stations. 

The Broadcast address is a predefined multicast address which denotes 
the set of all the stations oj» the Ethernet. 

Bit (the least significant bit of the first byte) of an address denotes 
the type: it is for physical addresses and 1 for multicast addresses. In 
either case the remaining 47 bits form the address value. A value of 48 
ones is always treated as the broadcast address. 

The hardware address of the KN210 module is determined at the time of 
manufacture and is stored in the network interface station address (NISA) 
ROM. Since every device that is intended to connect to an Ethernet 
network must have a unique physical address, the bit pattern blasted into 
the NISA ROM must be unique for each KN210. The multicast addresses 
to which the KN210 will respond are determined by the multicast address 
filter mask in the network interface initialization block. 

3.9.2 Network Interface Station Address ROM 

The network interface includes a byte-wide, 32-byte, socketed ROM called 
the network interface station address ROM (NISA ROM). One byte of 
this ROM appears in the low-order byte of each of 32 consecutive words 
in the address range 2008 4200 - 2008 427C i 6 . Bytes two and three of 
each word are undefined. The low-order byte of the first six words contain 
the 48-bit network physical address (NPA) of the KN210. The low-order 
byte in the remaining 26 words are unused. This address range is read 
only. Writes to this address range will result in a CDAL bus timeout 
and a machine check 83. The format for the NISA ROM is shown in 
Figure 3-44. 



Architecture 3-75 



3130 29 28 2726 25 24 23 22 21 2019 18 17 16 15 14 13 12 11 10 9876543210 



UNDEFINED 


NPA < 7:0 > 


UNDEFINED 


NPA < 15:8 > 


UNDEFINED 


NPA < 23:16 > 


UNDEFINED 


NPA < 31:17 > 


UNDEFINED 


NPA < 39:32 > 


UNDEFINED 


NPA < 47:40 > 


UNDEFINED 


UNUSED 







UNDEFINED 



MA-X0046-S6A 



Figure 3-44 Network Interface Station Address ROM Format 



3.9.3 LANCE Chip Overview 

The LANCE chip is a microprogrammed controller which can conduct 
extensive operations independently of the central processor. There are 
four control and status registers (CSRs) within the LANCE chip which 
are programmed by the central processor (the MicroVAX CPU chip) to 
initialize the LANCE chip and start its independent operation. Once 
started, the LANCE uses its built-in DMA controller to directly access NT 
buffer RAM to get additional operating parameters and to manage the 
buffers it uses to transfer packets to and from the Ethernet. The LANCE 
uses three structures in the NI buffer: 

1. Network Interface Initialization Block — 24 bytes of contiguous 
memory starting on a word boundary. The initialization block is set 
up by the central processor and is read by the LANCE when the 
processor starts the LANCE's initialization process. The initialization 
block contains the system's network address and pointers to the 
receive and transmit descriptor rings. 



3—76 Architecture 



2. Descriptor Rings — two logically circular rings of buffer descriptors, 
one ring used by the chip receiver for incoming data (the network 
interface receive descriptor ring) and one ring used by the chip 
transmitter for outgoing data (the network interface transmit 
descriptor ring). Each buffer descriptor in a ring is 8 bytes long 
and starts on an 8-byte boundary. It points to a data buffer elsewhere 
in memory, contains the size of that buffer, and holds various status 
information about the buffer's contents. 

3. Data Buffers — contiguous portions of memory to buffer incoming 
packets (Receive Data Buffers) or outgoing packets (transmit data 
buffers). Data buffers must be at least 64 bytes long (100 bytes for 
the first buffer of a packet to be transmitted) and may begin on any 
byte boundary. 

When the system is ready to begin network operation, the central 
processor sets up the network interface initialization block, the network 
interface receive descriptor ring, the network interface transmit descriptor 
ring, and their data buffers in the NI buffer RAM, and then starts the 
LANCE by writing to its CSRs. The LANCE performs its initialization 
process and then enters its polling loop. In this loop, it listens to the 
network for packets whose destination addresses are of interest and it 
scans the network interface transmit descriptor ring for descriptors which 
have been marked by the central processor to indicate that they contain 
outgoing data packets. 

When the LANCE detects a network packet of interest, it receives 
and stores that packet in one or more receive buffers and marks 
their descriptors accordingly. When the LANCE finds a packet to be 
transmitted, it transmits the packet to the network and marks its 
descriptor when transmission is complete. Whenever the LANCE chip 
completes a reception or transmission (or encounters an error condition), 
it sets flags in NICSRO to signal the central processor (usually by an 
interrupt) that it has done something of interest. 



Architecture 3—77 



3.9.4 Network Interface Register Address Port 

The network interface register address port (NIRAP), address 
1008 4404 ie> i s a 16-bit register that is implemented on all designs 
that use the LANCE chip. It is used to select which of the four CSRs is 
accessed through the network interface register data port. The format for 
the NIRAP is shown in Figure 3—45. 



31302928272625242322212019181716151413121110 987654321 



UNDEFINED 


RESERVED 








CSR I 

SEL 





MA-X0047-88 



Figure 3-45 Network Interface Register Address Port 



Data Bit 



Definition 



NIRAP 
<31:16> 

NIRAP 
<15:2> 

NIRAP <1:0> 



Undefined. Should not be read or written. 



Reserved. Ignored on write; read as zeros. 



(CSRSEL) CSR select <1:0>. Read/Write. These bits select 
which of the four control and status registers (NICSR0-NICSR3) 
is accessible through the register data port. Cleared on power- 
up, by writing NICSR0 <2>, and by the negation of DCOK 
when SCR <7> is clear. Values are as follows: 



Bits 1:0 Register 



00 


NICSR0 


01 


NICSR1 


10 


NICSR2 


11 


NICSR3 



3—78 Architecture 



3.9.5 Network Interface Register Data Port 

The network interface register data port (NIRDP), address 1008 4400 ie, 
is a 16-bit register that is implemented on all designs that use the LANCE 
chip. It is used as a 16-bit window through which the CPU can read and 
write the control and status register (NICSR0-NICSR3) designated by the 
NIRAP. 

Note that registers NICSR1, NICSR2, and NICSR3 are accessible only 
while NICSRO <2>(STOP) is set. If NICSRO <2> is clear (that is, the 
LANCE chip is active), attempts to read from those registers will return 
undefined data and attempts to write to them will be ignored. Accesses 
to a command and status register through the NIRDP do not alter the 
contents of the NIRAP. In normal operation only NICSRO can be accessed, 
so the NIRAP should be configured so that NICSRO is accessible through 
the NIRDP and left that way. 

3.9.6 Network Interface Control and Status Register 

The network interface control and status register (NICSRO), address 
1008 4400 i 6 when NIRAP <1:0> are set to 00, is a 16-bit register that 
is implemented on all designs that use the LANCE chip. This register is 
used to start and stop the operation of the LANCE chip and to monitor 
its status. All of its bits can be read at any time and none of its bits 
are affected by reading the register. The effects of a write operation are 
described individually for each bit. When power is applied to the system, 
all the bits in this register are cleared except the STOP bit which is set. 
The format for NICSRO is shown in Figure 3-46. 



Architecture 3—79 



15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 



UNDEFINED 



ERR 

BABL 

CERR 

MISS 

MERR 

RINT 

TINT 

IDON 

INTR 

INEA 

RXON 

TXON 

THMn 

STOP 



MA-X0048-88 



Figure 3-46 Network Interface Control and Status Register 



Data Bit 



Definition 



NICSRO 
<31:16> 

NICSRO <15> 



Undefined. Should not be lead or written. 



(ERR) Error summary. Read only. Writes have no effect. 
This bit is set whenever NICSRO <14> (BABL), NICSRO 
<13>(CERR), NICSRO <12> (MISS), or NICSRO <11> (MERR) 
are set. Cleared by clearing BABL, CERR, MISS and MERR, 
by setting NICSRO <2>, on power-up and the assertion of 
IORESET. 



3—80 Architecture 



Data Bit 



Definition 



NICSRO <14> (BABL) Transmitter timeout error. Read/Write to clear. This 
bit is set when the transmitter has been on the channel longer 
than the time required to send the maximum length packet. 
It will be set after 1519 data bytes have been transmitted (the 
LANCE will continue to transmit until the whole packet is 
transmitted or there is a failure). When this bit is set, NICSRO 
<15> (ERR) and NICSRO <7> (INTR) will also be set. Writing a 
has no effect. Cleared by writing a 1, by setting NICSRO <2>, 
on power-up and the assertion of IORESET. 

NICSRO <13> (CERR) Collision error. Read/Write to clear. This bit is set 

when the collision input to the LANCE chip failed to activate 
within 2 microseconds after a LANCE initiated transmission 
is completed. This collision after transmission is a transceiver 
test feature. This function is also known as heartbeat or signal 
quality error test (SQE). When this bit is set, NICSRO <15> 
is also set. Writing a has no effect. Cleared by writing a 
1, by setting NICSRO <2>, on power-up and the assertion of 
IORESET. 

NICSRO <12> (MISS) Missed packet. Read/Write to clear. This bit is set 
when the receiver loses a packet because it does not own a 
receive buffer. The MISS bit is not valid in internal loopback 
mode. When this bit is set, NICSRO <15> and NICSRO <7> 
bits are also set. Writing a has no effect. Cleared by writing 
a 1, by setting NICSRO <2>, on power-up and the assertion of 
IORESET. 

NICSRO <11> (MERR) Memory error. Read/Write to clear. This bit is set 

when the LANCE chip attempts a DMA transfer and does not 
receive a ready response from the network interface buffer RAM 
within 25.6 microseconds after beginning the memory cycle. 
When MERR is set, the receiver and transmitter are turned off 
(NICSRO <5:4> cleared). When this bit is set, NICSRO <15> 
and NICSRO <7> bits are also set. Writing a has no effect. 
Cleared by writing a 1, by setting NICSRO <2>, on power-up 
and the assertion of IORESET. 



Architecture 3—81 



Data Bit 



Definition 



NICSRO <10> (RINT) Receive interrupt. Read/Write to clear. This bit is 
set when the LANCE chip updates an entry in the receive 
descriptor ring for the last buffer received or when reception 
is stopped due to a failure. When this bit is set, NICSRO <7> 
is also set. Writing a has no effect. Cleared by writing a 
1, by setting NICSRO <2>, on power-up and the assertion of 
IORESET. 

NICSRO <9> (TINT) Transmitter interrupt. Read/Write to clear. This bit is 

set when the LANCE chip updates an entry in the transmit 
descriptor ring for the last buffer sent or when transmission 
is stopped due to a failure. When this bit is set, NICSRO <7> 
is also set. Writing a has no effect. Cleared by writing a 
1, by setting NICSRO <2>, on power-up and the assertion of 
IORESET. 

NICSRO <8> (IDON) Initialization done. Read/Write to clear. This bit is 

set when the LANCE chip completes the initialization process 
which was started by setting NICSRO <0> (INIT). When IDON 
is set, the LANCE chip has read the initialization block from 
memory and stored the new parameters. When this bit is set, 
NICSRO <7> is also Bet. Writing a has no effect. Cleared 
by writing a 1, by setting NICSRO <2>, on power-up and the 
assertion of IORESET. 

NICSRO <7> (INTR) Interrupt request. Read only. This bit is set whenever 

any of the bits NICSRO <14> (BABL), NICSRO <12> (MISS), 
NICSRO <11> (MERR), NICSRO <10> (RINT), NICSRO <9> 
(TINT), or NICSRO <8> (IDON) are set. When both this bit and 
NICSRO <6> (INEA) are set, an interrupt request is posted on 
IRQ2 at IPL 16 with vector offset of D5 i6 . Writing to this bit 
has no effect. Cleared by clearing BABL, MISS, MERR, RINT, 
TINT, and IDON, by setting NICSRO <2>, on power-up and the 
assertion of IORESET. 

NICSRO <6> (INEA) Interrupt enable. Read/Write. This bit controls whether 

the setting of the NICSRO <7> (INTR) bit generates an 
interrupt request. When both this bit and NICSRO <6> (INEA) 
are set, an interrupt request is posted at IPL 14 with vector 
offset of D4 i6- Cleared by setting NICSRO <2>, on power-up 
and the assertion of IORESET. 



3-82 Architecture 



Data Bit 



Definition 



NICSRO <5> (RXON) Receiver on. Read only. When set, this bit indicates 

that the receiver is enabled. This bit is set when initialization 
is completed (that is, when IDON is set, unless the DRX bit 
of the initialization block mode register was one) and then 
NICSRO <1> (STRT) is set. Writing to this bit has no effect. 
Cleared by setting NICSRO <2> or NICSRO <11>, on power-up 
and the assertion of IORESET. 

NICSRO <4> (TXON) Transmitter on. Read only. When set, this bit 

indicates that the transmitter is enabled. This bit is set when 
initialization is completed (that is, when IDON is set, unless 
the DTX bit of the initialization block mode register was one) 
and then NICSRO <1> (STRT) is set. Writing to this bit has 
no effect. Cleared by setting NICSRO <2>, NICSRO <11>, 
NITMD2 <31> (UFLO), NITMD2 <30> (BUFF), or NITMD2 
<26> (RTRY), on power-up and the assertion of IORESET. 

NICSRO <3> (TDMD) Transmit demand. Read/Write. Setting this bit signals 

the LANCE chip to access the transmit descriptor ring without 
waiting for the polltime interval to elapse. This bit need not 
be set to transmit a packet; setting it merely hastens the chip's 
response to the insertion of a transmit descriptor ring entry by 
the host program. This bit is cleared by the LANCE chip when 
it recognizes the bit has been set (the bit may read as one for a 
short time after it is set, depending upon the level of activity in 
the LANCE chip). Writing a zero has no effect. This bit is also 
cleared by setting NICSRO <2>, on power-up and the assertion 
of IORESET. 

NICSRO <2> (STOP) Stop external activity. Read/Write. Setting this bit 

stops all external activity and clears the internal logic of the 
LANCE chip; this has the same effect on the LANCE chip as 
a hardware reset does. When set, the LANCE chip remains 
inactive until NICSRO <1> (STRT) or NICSRO <0> (INIT) are 
set. Setting STOP clears all the other bits in this register. 



Architecture 3—83 



Data Bit 



Definition 



After STOP has been set, the other three command and status 
registers (NICSR1, NICSR2, and NICSR3) must be reloaded 
before setting INIT or STRT (note that NICSR1, NICSR2, 
and NICSR3 may be accessed only while STOP is set). If the 
processor attempts to set STOP, INIT, and STRT at the same 
time, STOP takes precedence and neither STRT nor INIT is set. 
Writing zero has no effect. This bit is set on power-up and the 
assertion of IORESET. It is cleared by setting either INIT or 
STRT. 

NICSRO <1> (STRT) Start operation. Read/Write. Setting this bit enables 

the LANCE chip to send and receive packets, perform DMA and 
manage its buffers. The STOP bit must be set prior to setting 
the STRT bit (setting STRT then clears STOP). Writing a has 
no effect. Cleared by setting NICSRO <2>, on power-up and the 
assertion of IORESET. 

NICSRO <0> (INIT) Initialize. Read/Write. Setting this bit causes the 

LANCE chip to perform its initialization process, which reads 
the initialization block from the area in the network interface 
buffer RAM addressed by the contents of NICSR1 and NICSR2 
through DMA. The STOP bit must be set prior to setting the 
INIT bit (setting INIT then clears STOP). Writing a zero has 
no effect. Cleared by setting NICSRO <2>, on power-up and the 
assertion of IORESET. 



NOTE 

The INIT and STRT bits must not be set at the same time. 

The proper initialization procedure is as follows: 

Set STOP in NICSRO 

Set up the initialization block in memory 

Load NICSR1 and NICSR2 with the starting address of the 
initialization block 

Set INIT in NICSRO 

Wait for IDON in NICSRO to become set 

Set STRT in NICSRO to begin operation 



3-84 Architecture 



3.9.7 Network Interface Control and Status Register 1 

The network interface control and status register 1 (NICSR1) (address 
1008 4400 16 when NIRAP <1:0> are set to 01) is a 16-bit register that 
is implemented on all designs that use the LANCE chip. This register is 
used in conjunction with NICSR2 to supply the network interface buffer 
RAM address of the initialization block which the chip reads when it 
performs its initialization process. This register is accessible only if the 
STOP bit in NICSR0 is set. Bits <31:16> are undefined and bits <15:0> 
are read/write. On power-up, all the bits in this register are undefined. 
The format NICSR1 is shown in Figure 3-^7. 



31302928272625242322212019181716151413121110 987654321 



UNDEFINED 


I ADR 15:0 



MA-X0049-88 



Figure 3-47 Network Interface Control and Status Register 1 



Data Bit 



Definition 



NICSR1 
<31:16> 

NICSR1 
<15:0> 



Undefined. Should not be read or written. 



(IADR15:0) Initialization block address bits <15:0>. Read/Write. 
These are the low-order sixteen bits of the network interface 
buffer RAM address of the first byte of the initialization block. 
Note that since the block must be aligned on a word boundary 
bit <0> must be zero. 



3.9.8 Network Interface Control and Status Register 2 

The network interface control and status register 2 (NICSR2) (address 
1008 4400 16 when NIRAP <1:0> are set to 10) is a 16-bit register that 
is implemented on all designs that use the LANCE chip. This register is 
used in conjunction with NICSR1 to supply the network interface buffer 
RAM address of the initialization block which the chip reads when it 
performs its initialization process. This register is accessible only if the 
STOP bit in NICSR0 is set. Bits <31:16> are undefined bits <15:8> are 
reserved and bits <15:0> are read/write. On power-up, all the bits in this 
register are undefined. The format for NICSR2 is shown in Figure 3—48. 



Architecture 3—85 



31302928272625242322212019181716151413121110 987654321 



UNDEFINED 


RESERVED 


IADR 23:16 



Figure 3-48 Network Interface Control and Status Register 2 



Data Bit 



Definition 



NICSR2 
<31:16> 

NICSR2 
<15:8> 

NICSR2 
<7:0> 



Undefined. Should not be read or written. 

Reserved. Should not be read or written. 

(IADR23:16) Initialization block address bits <23:16>. 
Read/Write. These are bits 23:16 of the network interface 
buffer RAM address of the first byte of the initialization block 



3.9.9 Network Interface Control and Status Register 3 

The network interface control and status register 3 (NICSR3), address 
1008 4400 i 6 when NIRAP <1:0> are set to 11, is a 16-bit register that 
is implemented on all designs that use the LANCE chip. This register 
controls certain aspects of the electrical interface between the LANCE 
chip and the system. It must be set by the on-board firmware as indicated 
for each bit. This register is accessible only if the STOP bit in NICSR0 is 
set. Bits <31:16> are undefined, bits <15:3> are reserved and bits <3:0> 
are read/write. The format for NICSR3 is shown in Figure 3-49. 



31302928272625242322212019181716151413121110 987654321 



UNDEFINED 



RESERVED 



BSWP __T 

ACON 

BCON 



Figure 3-49 Network Interface Control and Status Register 3 



3-86 Architecture 



Data Bit 



Definition 



NICSR3 
<31:16> 

NICSR3 
<15:3> 

NICSR3 <2> 



NICSR3 <1> 



NICSR3 <0> 



Undefined. Should not be read or written. 

Reserved. Read as zeros. Writes have no effect. 

(BSWP) Byte swap. Read/Write. When this bit is set, the 
LANCE chip will swap the high and low bytes for DMA data 
transfers between the silo and the network interface buffer 
RAM in order to accomodate processors which consider address 
bits <15:08> to be the least significant byte of data. Cleared 
by setting NICSRO <2>, on power-up and the assertion of 
IORESET. This bit must be set to by the on-board firmware. 

(ACON) ALE control. Read/Write. This bit controls the polarity 
of the signal emitted on the LANCE chip's ALE/AS pin during 
DMA operation. Cleared by setting NICSRO <2>, on power-up 
and the assertion of IORESET. This bit must be set to by the 
on-board firmware. 

(BCON) Byte control. Read/Write. This bit controls the 
configuration of the byte mask and hold signals on the LANCE 
chip's pins during DMA operation. Cleared by setting NICSRO 
<2>, on power-up and the assertion of IORESET. This bit must 
be set to by the on-board firmware. 



3.9.10 Network Interface Initialization Block 

When the LANCE chip is initialized (by setting the INIT bit in NICSRO), 
it reads a 24-byte block of data called the network interface initialization 
block (NIIB) from the network interface buffer RAM using DMA accesses. 
The base address of the initialization block is formed by concatenating 
the contents of the NICSR1 and NICSR2. Since the NIIB must start 
on a word boundary, the low-order bit of the address must be zero. The 
initialization block is made up of twelve 16-bit words, (NIIBW0-NIIBW11), 
arranged as shown in Figure 3—50. 



Architecture 3-87 



151413121110 987654321 



NIIBWO 


MODE 


:BASE 


NIIBW1 


NETWORK 


:BASE + 2 


NIIBW2 


PHYSICAL 
ADDRESS 


:BASE + 4 


NIIBW3 




:BASE + 6 


NIIBW4 




:BASE + 8 


NIIBW5 


MULTICAST 

ADDRESS 


:BASE + 10 


NIIBW6 


NLItK 

MASK 


:BASE + 12 


N1IBW7 




:BASE + 14 


N1IBW8 


RECEIVE 


:BASE + 16 


N1IBW9 


POINTER 


:BASE + 18 


NIIBW10 


TRANMIT 
DESCRIPTOR RING 


:BASE + 20 


NIIBW11 


POINTER 


:BASE + 22 






MA-XO053-88 



Figure 3-50 Network Interface Initialization Block 

3.9.10.1 Network Interface Initialization Block Word 

Word of the network interface initialization block (NIIBWO), also 
referred to as the mode word, resides in the network interface buffer 
RAM at the base address of the initialization block. The mode word of 
the initialization block allows alteration of the LANCE chip's normal 
operation for testing and special applications. For normal operation 
the mode word is entirely zero. The format for NIIBWO is shown in 
Figure 3-51. 



3—88 Architecture 



151413121110 987654321 



PROM 









J 


INTL I 

DRTY I 

r.n\ I 


nmR 


mnp 


irrv 


nRY 



Figure 3-51 Network Interface Initialization Block Word 



Data Bit 



Definition 



NIIBW0<15> (PROM) Promiscuous mode. When set, all incoming packets 

are accepted regardless of their destination addresses. 
When cleared, only incoming packets with a destination 
address that matches the KN210's address are accepted 
(normal operating mode). 

NIIBW0<14:7> Reserved. Should be written with zeros. 

NIIBW0<6> (INTL) Internal loopback. This bit is used in conjunction 

with the NIIBW0<2> (LOOP) to control loopback operation. 
See the description of the LOOP bit, below. 

NIIBW0<5> (DRTY) Disable retry. When set, the LANCE chip will 

attempt only one transmission of a packet. If there is a 
collision on the first transmission attempt, a retry error 
(RTE) will be reported in the transmit buffer descriptor. 

NIIBW0<4> (COLL) Force collision. When set, the collision logic can be 

tested. The LANCE chip must be in internal loopback mode 
for COLL to be used. When COLL is set to one, a collision 
will be forced during the subsequent transmission attempt. 
This will result in 16 transmission attempts and a retry 
error (RTE) being reported in the transmit buffer descriptor. 



Architecture 3-89 



Data Bit 



Definition 



NIIBW0<3> 



NIIBWO <2> 



(DTCR) Disable transmit CRC. When cleared, the 
transmitter will generate and append a 4-byte CRC to 
each transmitted packet (normal operation). When DTCR is 
one the CRC logic is allocated instead to the receiver and no 
CRC is sent with a transmitted packet. 

During loopback, setting DTCR to zero will cause a CRC to 
be generated and sent with the transmitted packet, but no 
CRC check can be done by the receiver since the CRC logic 
is shared and cannot both generate and check a CRC at the 
same time. The CRC transmitted with the packet will be 
received and written into memory following the data where 
it can be checked by software. 

If DTCR is set to one during loopback, the driving software 
must compute and append a CRC value to the data to 
be transmitted. The receiver will check this CRC upon 
reception and report any error. 

(LOOP) Loopback control. This bit is used in conjunction 
with NIIBWO <6> to perform internal loopback tests on the 
LANCE chip. During loopback the LANCE chip operates 
in full duplex mode. The maximum packet size is limited 
to 32 data bytes (in addition to which 4 CRC bytes may 
be appended). During loopback, the runt packet filter 
is disabled because the maximum packet is forced to be 
smaller than the minimum size Ethernet packet (64 bytes). 

Setting LOOP to one allows simultaneous transmission and 
reception for a packet constrained to fit within the silo. 
The chip waits until the entire packet is in the silo before 
beginning serial transmission. The incoming data stream 
fills the silo from behind as it is being emptied. Moving the 
received packet out of the silo into memory does not begin 
until reception has ceased. 

In loopback mode, transmit data chaining is not possible. 
Receive data chaining is allowed regardless of the receive 
buffer length. (In normal operation, the receive buffers 
must be 64 bytes long, to allow time for buffer lookahead.) 



3—90 Architecture 



Data Bit 



Definition 



Valid loopback bit settings are: 



LOOP INTL Operation 



x Normal on-line operation 

1 External loopback 
1 1 Internal loopback 



Internal loopback allows the LANCE chip to receive its own 
transmitted packet without disturbing the network. The 
LANCE chip will not receive any packets from the network 
while it is in internal loopback mode. 

External loopback allows the LANCE chip to transmit a 
packet through the transceiver out to the network cable 
to check the operability of all circuits and connections 
between the LANCE chip and the network cable. Multicast 
addressing in external loopback is valid only when DTCR 
is one (user needs to append the 4 CRC bytes). In external 
loopback, the LANCE chip also receives packets from other 
nodes. 

NIIBW0<1> (DTX) Disable transmitter. When set, the LANCE chip 

will not set the TXON bit in NICSRO at the completion 
of initialization. This will prevent the LANCE chip from 
attempting to access the transmit descriptor ring, hence no 
transmissions will be attempted. 

NIIBW0<0> (DRX) Disable receiver. When set, the LANCE chip will 

not set the RXON bit in NICSRO at the completion of 
initialization. This will cause the LANCE chip to reject all 
incoming packets and to not attempt to access the receive 
descriptor ring. 



3.9.10.2 Network Interface Initialization Block Words 1-3 

Words 1-3 of the network interface initialization block (NIIBW1-3), reside 
in the network interface buffer RAM at the base address of the NIIB plus 
2, 4, and 6 respectively. These three words contain the 48-bit NPA of the 
KN210 and are loaded by the resident firmware from the NISA ROM. 



Architecture 3—91 



This address identifies the KN210 to the Ethernet network and must be 
unique within the domain of the network. The low-order bit (bit 0) of this 
address must be zero to indicate it is a physical rather than multicast 
address. The format for network interface initialization block words 1 
through 3 is shown in Figure 3—52. 





151413121110 987654321 


NIIBW1 


NETWORK PHYSICAL ADDRESS < 15:0 > 


NIIBW2 


NETWORK PHYSICAL ADDRESS < 31:16> 


NIIBW3 


NETWORK PHYSICAL ADDRESS < 47:17> 



.-BASE + 2 
:BASE + 4 
:BASE + 6 

MA-X0055-88 



Figure 3-52 Network Interface Initialization Block Words 1-3 

3.9.10.3 Network Interface Initialization Block Words 4-7 

Words 4-7 of the network interface initialization block (NIIBW4-7), reside 
in network interface buffer RAM at the base address of the NIIB plus 8, 
10, 12, and 14 respectively. These four words contain the 64-bit multicast 
address filter mask. The format for network interface initialization block 
words 4 through 7 is shown in Figure 3-53. 





151413121110 987654321 


NIIBW4 


MULTICAST ADD FILTER < 15:0 > 


NIIBW5 


MULTICAST ADD FILTER MSK <31:16> 


NIIBW6 


MULTICAST ADD FILTER MSK <47:17> 


NIIBW7 


MULTICAST ADD FILTER MSK <48:18> 



BASE + 8 
BASE + 10 
BASE + 12 
BASE + 14 

MA-X0036-88 



Figure 3-53 Network Interface Initialization Block Words 4-7 

Multicast Ethernet addresses are distinguished from physical network 
addresses by the presence of a one in bit of the 48-bit address field. If 
an incoming packet contains a physical destination address (bit is zero), 
then its entire 48 bits are compared with the network physical address 
and the packet is ignored if they are not equal. If the packet contains a 
multicast destination address which is all ones (the broadcast address), it 
is always accepted and stored regardless of the contents of the multicast 
address filter mask. 



3-92 Architecture 



All other multicast addresses are processed through the multicast address 
filter to determine whether the incoming packet will be stored in a receive 
buffer. This filtering is performed by passing the multicast address field 
through the CRC generator. The high-order 6 bits of the resulting 32-bit 
CRC are used to select one of the 64 bits of the multicast address filter 
mask. (These high-order six bits represent in binary the number of the 
bit in the multicast address filter mask.) 

If the bit selected from the multicast address filter mask is one, the packet 
is stored in a receive buffer; otherwise it is ignored. This mechanism 
effectively splits the entire domain of 2**47 multicast addresses into 64 
parts, and multicast addresses falling into each part will be accepted or 
ignored according to the value of the corresponding bit in the multicast 
address filter mask. The driver program must examine the addresses of 
the packets accepted by this partial filtering to complete the filtering task. 

3.9.10.4 Network Interface Initialization Block Words 8,9 

Words 8 and 9 of the network interface initialization block (NIIBW8,9), 
also referred to as the receive descriptor ring pointer, reside in network 
interface buffer RAM at the base address of the NIIB plus 16 and 18 
respectively. These two words contain the starting address and the 
number of descriptors in the receive descriptor ring. The format for 
NIIBW8 is shown in Figure 3-54. 



NIIBW8 



151413121110 987654321 

:BASE + 16 



RDRA < 15:0 > 



MA-X0057-88 



Figure 3-54 Network Interface Initialization Block Word 8 

Data Bit Definition 

NIIBW8 (RDRA <15:0>) Receive descriptor ring address <15:0>. This 

<15:0> field contains bits <15:0> of the base address of the receive 

descriptor ring. Since the receive descriptor ring must start on 
an 8-byte boundary, bits <2:0> of this field must be zero. 

The format for NIIBW9 is shown in Figure 3—55. 



Architecture 3-93 



151413121110 987654321 



NIIBW9 



NRBD 


RESERVED 


RDRA < 23:16 > 



:BASE + 18 



MA-X0058-88 



Figure 3-55 Network Interface Initialization Block Word 9 



Data Bit 



Definition 



NIIBW9<15:13> (NRBD) Number of receive buffer descriptors. This field 

gives the number of receive buffer descriptors in the receive 
descriptor ring, expressed as a power of two: 



Value Number of Descriptors 



000 
001 
010 
011 
100 
101 
110 

111 



1 

2 

4 

8 

16 

32 

64 

128 



NIIBW9<12:8> Reserved; should be zeros. 

NIIBW9<7:0> (RDRA <23:16>) Receive descriptor ring address <23:16>. This 
field contains bits <23:16> of the base address of the receive 
descriptor ring. 



3—94 Architecture 



3.9.10.5 Network Interface Initialization Block Words 10,11 

Words 10 and 11 of the network interface initialization block 
(NIIBW10,11), also referred to as the transmit descriptor ring pointer, 
reside in network interface buffer RAM at the base address of the NUB 
plus 20 and 22 respectively. These two words contain the starting address 
and the number of transmit buffer descriptors in the transmit descriptor 
ring. The format for NIIBW10 is shown in Figure 3-56. 



151413121110 987654321 
NIIBW10 



TDRA < 15:0 > 



:BASE + 20 

MA-X0059-88 



Figure 3-56 Network Interface Initialization Block Word 10 

Data Bit Definition 

NIIBW10<15:0> (TDRA <15:0>) Transmit descriptor ring address <15:0>. This 
field contains bits <15:0> of the base address of the transmit 
descriptor ring. Since the transmit descriptor ring must start 
on an 8-byte boundary, bits <2:0> of this field must be zero. 

The format for NIIBW11 is shown in Figure 3-57. 



151413121110 987654321 

.•BASE + 22 



NTBD 



RESERVED 



TDRA < 23:16 > 



MA-X0060-88 



Figure 3-57 Network Interface Initialization Block Word 11 



Architecture 3—95 



Data Bit 



Definition 



NIIBW11<15:13> (NTBD) Number of transmit buffer descriptors. This field 

gives the number of transmit buffer descriptors in the transmit 
descriptor ring, expressed as a power of two: 



Value Number of Descriptors 



000 
001 
010 
011 
100 
101 
110 

111 



1 

2 

4 

8 

16 

32 

64 

128 



NIIBW11 
<12:8> 

NIIBW11 
<7:0> 



Reserved; should be zeros. 

(TDRA <23:16>) Transmit descriptor ring address <23:16>. 
This field contains bits <23:16> of the base address of the 
transmit descriptor ring. 



3.9.11 Buffer Management 

The LANCE chip manages its data buffers by using two rings of buffer 
descriptors which are stored in the network interface buffer RAM: the 
network interface receive descriptor ring and the network interface 
transmit descriptor ring. Each buffer descriptor points to a data buffer 
elsewhere in the network interface buffer RAM, contains the size of that 
buffer, and contains status information about that buffer's contents. 

The starting location in the network interface buffer RAM of each ring 
and the number of descriptors in it are given to the LANCE chip through 
the NIIB during the chip initialization process. Each descriptor is 8 bytes 
long and must be aligned on an 8-byte boundary (the three low-order bits 
of its address must be zero). The descriptors in a ring are physically 
contiguous in the network interface buffer RAM and the number of 
descriptors must be a power of two. The LANCE keeps an internal 
index to its current position in each ring which it increments modulo 
the number of descriptors in the ring as it advances around each ring. 



3—96 Architecture 



Once started, the LANCE chip polls each ring to find descriptors for 
buffers in which to receive incoming packets and from which to transmit 
outgoing packets, and revises the status information in buffer descriptors 
as it processes their associated buffers. When polling, the LANCE chip 
is limited to looking only one ahead of the descriptor with which it is 
currently working. The high speed of the data stream requires that 
each buffer be at least 64 bytes long to allow time to chain buffers for 
packets which are larger than one buffer. (The first buffer of a packet to 
be transmitted should be at least 100 bytes to avoid problems in case a 
late collision is detected.) 

Each descriptor in a ring is "owned" either by the LANCE chip or by the 
host processor; this status is indicated by the OWN bit in each descriptor. 
Mutual exclusion is accomplished by the rule that each device can only 
relinquish ownership of a descriptor to the other device, it can never take 
ownership; and that each device cannot change any field in a descriptor 
or its associated buffer after it has relinquished ownership. When the 
host processor sets up the rings of descriptors before starting the LANCE 
chip, it sets the OWN bits such that the LANCE chip will own all the 
descriptors in the network interface receive descriptor ring (to be used by 
the LANCE to receive packets from the network) and the host will own 
all the descriptors in the network interface transmit descriptor ring (to be 
used by the host to set up packets to be transmitted to the network). 

3.9.1 2 Network Interface Receive Descriptor Ring 

The network interface receive descriptor ring (NIRDR) contains a receive 
buffer descriptor for each receive buffer (Figure 3—58). It is located in a 
contiguous block of the network interface buffer RAM whose base address 
is formed by concatenating the contents of NIIBW8 and NIIBW9 <7:0> 
(RDRA<23:0>). Since the NTRDR must start on an 8-byte boundary, bits 
<2:0> of this address must be zero. The size of the network interface 
receive descriptor ring can vary between 8 and 1024 bytes depending 
on the number of 8-byte descriptors it contains (Figure 3-58). The 
number of descriptors must be a power of two between one and 128 
and is determined by NIIBW9 <15:13> (NRBD). 



Architecture 3-97 



151413121110 987654321 



RECEIVE 
BUFFER 
DESCRIPTOR 



RECEIVE 
BUFFER 
DESCRIPTOR 1 



RECEIVE 
BUFFER 
DESCRIPTOR N 



:BASE 



:BASE + 8 



:BASE + 8N 



Figure 3-58 Network Interface Receive Descriptor Ring 

3.9.12.1 Receive Buffer Descriptors 

Receive buffer descriptor n contains the base address and size of a receive 
buffer as well as status and error information. It is four words (eight 
bytes) in length and is located in the receive descriptor ring at base+8n. 

A representation of a typical receive buffer descriptor (RBD) is shown in 
Figure 3-59. 



3-98 Architecture 



RBDnWO 
RBDnWI 
RBDnW2 
RBDnW3 



151413121110 987654321 







RECEIVER 
BUFFER 


DESCRIPTOR n 





MA-X0062-88 



Figure 3-59 Receive Buffer Descriptors 

Receive Buffer Descriptor n Word 

Word of RBD n (RBDnWO) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n. This word contains a portion of 
the base address of the associated receive buffer. The format for receive 
buffer descriptor n word is shown in Figure 3-60. 



151413121110 987654321 



RBDnWO 



BADR < 15:0 > 



:BASE + 8n 



MA-X0063-88 



Figure 3-60 Receive Buffer Descriptor n Word 



Data Bit 



Definition 



RBDnWO (BADR) Buffer address. This field contains bits <15:0> of the 

<15:0> 24-bit network address buffer RAM address of the start of the 

buffer associated with this descriptor. Written by the host; 

unchanged by the LANCE. 



Architecture 3—99 



Receive Buffer Descriptor n Word 1 

Word 1 of RBD n (RBDnWI) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n+2. This word contains a portion 
of the base address of the associated receive buffer as well as status and 
error information. The format for receive buffer descriptor n word 1 is 
shown in Figure 3-61. 



151413121110 987654321 



RBDnWI 





BADR < 23:16 > 


1 ENP 

STP 


RIIF 


HHF 


DFF 


FRF 


FRR 


OWN 



:BASE + 8n + 2 



Figure 3-61 Receive Buffer Descriptor n Word 1 



Data Bit 



Definition 



RBDnWI (OWN) Owned flag. This bit indicates whether the descriptor is 

<15> owned by the host (OWN = 0) or by the LANCE chip (OWN = 

1). The LANCE clears OWN after filling the buffer associated 
with the descriptor with an incoming packet. The host sets 
OWN after emptying the buffer. In each case, this must be the 
last bit changed by the current owner, since changing OWN 
passes ownership to the other party and the relinquishing 
party must not thereafter alter anything in the descriptor or its 
buffer. 

RBDnWI (ERR) Error summary. This is the logical OR of the FRE, OFE, 

<14> CHE and BUE bits in this word. Set by the LANCE chip and 

cleared by the host. 

RBDnWI (FRE) Framing error. This bit is set by the LANCE chip to 

<13> indicate that the incoming packet stored in the buffer had both 

a non-integral multiple of 8 bits and a checksum error (CHE). 

It is cleared by the host. 



3-1 00 Architecture 



Data Bit 



Definition 



RBDnWl (OFE) Overflow error. This bit is set by the LANCE chip to 

<12> indicate that the receiver has lost part or all of an incoming 

packet because it could not store it in the buffer before the 

chip's silo overflowed. Cleared by the host. 

RBDnWl (CHE) Checksum error. This bit is set by the LANCE chip to 

<11> indicate that the received packet has an invalid CRC checksum. 

Cleared by the host. 

RBDnWl (BUE) Buffer error. This bit is set by the LANCE chip when 

<10> it has used all its owned receive descriptors or when it could 

not get the next descriptor in time while attempting to chain 
to a new buffer in the midst of a packet. When a buffer error 
occurs, an overflow error (bit OFLO) also occurs because the 
LANCE continues to attempt to get the next buffer until its silo 
overflows. BUE is cleared by the host. 

RBDnWl <9> (STP) Start of packet. This bit is set by the LANCE chip 
to indicate that this is the first buffer used for this packet. 
Cleared by the host. 

RBDnWl <8> (ENP) End of packet. This bit is set by the LANCE chip to 

indicate that this is the last buffer used for this packet. When 
both STP and ENP are set in a descriptor, its buffer contains an 
entire packet; otherwise two or more buffers have been chained 
together to hold the packet. ENP is cleared by the host. 

RBDnWl (BADR <23:16>) Buffer address <23:16>. This field contains 

<7:0> bits <23:16> of the 24-bit the NI buffer RAM address of the 

start of the buffer associated with this descriptor. Written by 

the host; unchanged by the LANCE. 



Receive Buffer Descriptor n Word 2 

Word 2 of RBD n (RBDn W2) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n+4. This word contains the size of 
the associated receive buffer. The format for receive buffer descriptor n 
word 2 is shown in Figure 3-62. 



RBDnW2 



Architecture 3—1 01 



151413121110 987654321 



1 


1 


1 


1 


BSZ < 11:0 > 



:BASE + 8n + 4 



MA-X0065-88 



Figure 3-62 Receive Buffer Descriptor n Word 2 



Data Bit 



Definition 



RBDnW2<15:12> 



RBDnW2<ll:0> 



These bits must be set by the host to ones. Unchanged by 
the LANCE chip. 

(BSZ <11:0>) Buffer size. This field contains the size (in 
bytes) of the associated receive buffer in two's complement 
form. Note that the minimum buffer size is 64 bytes (to 
allow enough time for chaining buffers) and the maximum 
buffer size is 1518 bytes (the largest legal Ethernet packet). 
Written by the host; unchanged by the LANCE chip. 



Receive Buffer Descriptor n Word 3 

Word 3 of RBD n (RBDnW3) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n+6. This word contains the size of 
the packet that was received. The format for receive buffer descriptor n 
word 3 is shown in Figure 3-63. 



RBDnW3 



151413121110 987654321 















PSZ < 11:0 > 



:BASE + 8n + 6 



MA-X0O66-88 



Figure 3-63 Receive Buffer Descriptor n Word 3 



3-1 02 Architecture 



Data Bit 



Definition 



RBDnW3<15:12> 



RBDnW3<ll:0> 



These bits are reserved. They should be set to zeros by the 
host when it constructs the descriptor. 

(PSZ <11:0>) Packet size. This field contains the size (in 
bytes) of the received packet. This field is valid only in a 
descriptor in which ENP is set Qast buffer) and ERR is clear 
(no error). Set by the LANCE chip and cleared by the host. 



3.9.13 Receive Buffers 

Receive buffers are set up by the host by adding a receive buffer descriptor 
to the network interface receive buffer descriptor ring. These buffers are 
used for storing incoming Ethernet packets. An Ethernet packet may 
span multiple buffers, but a buffer cannot contain more than one Ethernet 
packet. The base address of a receive buffer is formed by concatenating 
the contents of RBDnWO and RBDnWl <7:0> (BADR). The size of a 
receive buffer is determined by RBDnW2 <11:0>. 

Receive buffers are structured as shown in Figure 3-64. 



151413121110 987654321 



RECEIVE 
BUFFER 
( 64-1518 BYTES ) 



% 



:BASE 



% 



MA-X0067-88 



Figure 3-64 Receive Buffers 



Architecture 3-1 03 



3.9.1 4 Network Interface Transmit Descriptor Ring 

The network interface transmit descriptor ring (NITDR) contains a 
transmit buffer descriptor for each transmit buffer (Figure 3-65). It is 
located in a contiguous block of the network interface buffer RAM whose 
base address is formed by concatenating the contents of the NIIBW10 and 
NIIBW11 <7:0> (TDRA<23:0>). Since the NITDR must start on an 8-byte 
boundary, bits <2:0> of this address must be zero. The size of the network 
interface transmit descriptor ring can vary between 8 and 1024 bytes 
depending on the number of 8-byte descriptors it contains. The number of 
descriptors must be a power of 2 between 1 and 128 and is determined by 
NIIBW11 <15:13> (NTBD). 



151413121110 987654321 



TRANSMIT 
BUFFER 
DESCRIPTOR 



TRANSMIT 
BUFFER 
DESCRIPTOR 1 



r\> 



:BASE 



:BASE + 8n 



% 



TRANSMIT 
BUFFER 
DESCRIPTOR n 



:BASE + 8n 



MA-X0068-88 



Figure 3-65 Network Interface Transmit Descriptor Ring 



3—1 04 Architecture 



3.9.14.1 Transmit Buffer Descriptors 

Transmit buffer descriptor n contains the base address, size, of a transmit 
buffer as well as status and error information. It is four words (eight 
bytes) in length and is located in the transmit descriptor ring at base+8n. 

A representation of a typical transmit buffer descriptor (TBD) is shown in 
Figure 3-66. 



TBDnWO 
TBDnWI 
TBDnW2 
TBDnW3 



151413121110 9 8 7 6 


5 


4 


3 


2 1 




n 








TRANSMIT 
BUFFER 




DESCRIPTOR 









:BASE + 8n 



MA-X0069-88 



Figure 3-66 Transmit Buffer Descriptors 

Transmit Buffer Descriptor n Word 

Word of TBD n (TBDnWO) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n. This word contains a portion 
of the base address of the associated transmit buffer. The format for 
transmit buffer descriptor n word is shown in Figure 3-67. 



151413121110 987654321 



TBDnWO 



BADR < 15:0 > 



:BASE + 8n 

MA-X0070-88 



Figure 3-67 Transmit Buffer Descriptor n Word 



Data Bit 



Definition 



TBDnW0<15:0> (BADR) Buffer address. This field contains bits <15:0> of the 
24-bit network interface buffer RAM address of the start of 
the buffer associated with this descriptor. Written by the host; 
unchanged by the LANCE chip. 



Architecture 3—1 05 



Transmit Buffer Descriptor n Word 1 

Word 1 of TBD n (TBDnWl) resides in the network interface buffer RAM 
at the base address of the NIIRDR +8n+2. This word contains a portion 
of the base address of the associated transmit buffer as well as status and 
error information. The format for transmit buffer descriptor n word 1 is 
shown in Figure 3—68. 



151413121110 987654321 



TBDnWl 

OWN 
ERR 
RSV 
MRE 
ORE 
DEF 
STP 
ENP 







BADR < 23:16 > 


- 


J 

























:BASE + 8n + 2 



Figure 3-68 Transmit Buffer Descriptor n Word 1 



Data Bit 



Definition 



TBDnWl 
<15> 



TBDnWl 
<14> 

TBDnWl 
<13> 

TBDnWl 
<12> 



(OWN) Owned flag. This bit indicates whether the descriptor is 
owned by the host (OWN = 0) or by the LANCE chip (OWN = 
1). The LANCE clears OWN after filling the buffer associated 
with the descriptor with an incoming packet. The host sets 
OWN after emptying the buffer. In each case, this must be the 
last bit changed by the current owner, since changing OWN 
passes ownership to the other party and the relinquishing 
party must not thereafter alter anything in the descriptor or its 
buffer. 

(ERR) Error summary. This bit is the logical OR of the COE, 
CAE, UFE and RTE bits in this descriptor. Set by the LANCE 
chip and cleared by the host. 

(RSV) Reserved. The LANCE chip will write a zero in this bit. 



(MRE) More retries. The LANCE chip sets this bit when more 
than one retry was required to transmit the packet. Cleared by 
the host. 



3-1 06 Architecture 



Data Bit 



Definition 



(ORE) One retry. The LANCE chip sets this bit when exactly 
one retry was required to transmit the packet. Cleared by the 
host. 

(DEF) Deferred. The LANCE chip sets this bit when it had to 
defer while trying to transmit the packet. This occurs when the 
network is busy when the LANCE is ready to transmit. Cleared 
by the host. 

(STP) Start of packet. This bit is set by the host to indicate that 
this is the first buffer used for this packet. STP is not changed 
by the LANCE chip. 

(ENP) End of packet. This bit is set by the host to indicate that 
this is the last buffer used for this packet. When both STP and 
ENP are set in a descriptor, its buffer contains an entire packet; 
otherwise two or more buffers have been chained together to 
hold the packet. ENP is not changed by the LANCE chip. 

TBDnWl (BADR <23:16>) Buffer address <23:16>. This field contains 

<7:0> bits <23:16> of the 24-bit network interface buffer RAM address 

of the start of the buffer associated with this descriptor. Written 
by the host; unchanged by the LANCE chip. 



TBDnWl 
<11> 

TBDnWl 
<10> 



TBDnWl <9> 



TBDnWl <8> 



Transmit Buffer Descriptor n Word 2 

Word 2 of TBD n (TBDnW2) resides in the network interface buffer RAM 
at the base address of the NIITDR +8n+4. This word contains the size of 
the associated transmit buffer. The format for transmit buffer descriptor 
n word 2 is shown in Figure 3—69. 



15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 



TBDnW2 1111 



BSZ < 11:0 > 



:BASE + 8N + 4 



MA-X0072-88A 



Figure 3-69 Transmit Buffer Descriptor n Word 2 



Architecture 3-1 07 



Data Bit 



Definition 



TBDnW2<15:12> These bits must be set by the host to ones. Unchanged by the 
LANCE chip. 

TBDnW2 (BSZ <11:0>) Buffer size. This field contains the size (in bytes) 

<11:0> of the associated transmit buffer in two's complement form. 

Note that the minimum buffer size is 64 bytes (to allow enough 
time for chaining buffers) and the maximum buffer size is 1518 
bytes (the largest legal Ethernet packet). Written by the host; 
unchanged by the LANCE chip. 

Transmit Buffer Descriptor n Word 3 

Word 3 of TBD n (TBDnW3) resides in the network interface buffer RAM 
at the base address of the NIITDR +8n+6. This word contains error 
information and a time domain reflectometer. The contents of this word 
are valid only when the ERR bit in TBDnW2 has been set by the LANCE 
chip. 

The format for transmit buffer descriptor n word 3 is shown in 
Figure 3-70. 



:BASE + 8n + 6 





151413121110 987654321 





TBDnW3 




TDR < 9:0 > 


BUE _ 

UFE 


J 






B5V 




rnt 




HAF 




RTF 





MA-X0073-88 



Figure 3-70 Transmit Buffer Descriptor n Word 3 



3-1 08 Architecture 



Data Bit 



Definition 



TBDnW3 
<15> 



TBDnW3 
<14> 



TBDnW3 
<13> 

TBDnW3 
<12> 



TBDnW3 
<11> 



TBDnW3 
<10> 



TBDnW3 
<9:0> 



(BUE) Buffer error. This bit is set by the LANCE chip during 
transmission when it does not find the ENP bit set in the 
current descriptor and it does not own the next descriptor. 
When BUE is set, the UFE bit (below) is also set because the 
LANCE chip continues to transmit until its silo becomes empty. 
BUE is cleared by the host. 

(UFE) Underflow error. This bit is set by the LANCE chip when 
it truncates a packet being transmitted because it has drained 
its silo before it was able to obtain additional data from a buffer 
in memory. UFE is cleared by the host. 

(RSV) Reserved. The LANCE chip will write a zero in this bit. 



(COE) Late collision error. This bit is set by the LANCE chip to 
indicate that a collision has occurred after the slot time of the 
network channel has elapsed. The LANCE chip does not retry 
after a late collision. COE is cleared by the host. 

(CAE) Loss of carrier error. This bit is set by the LANCE chip 
when the carrier present input to the chip becomes false during 
a transmission initiated by the LANCE. The LANCE chip does 
not retry after such a failure. CAE is cleared by the host. 

(RTE) Retries exhausted. This bit is set by the LANCE chip 
after 16 attempts to transmit a packet have failed due to 
repeated collisions on the network. (If the DRTY bit of network 
interface initialization block word (mode word) is set, RTE 
will instead be set after only one failed transmission attempt.) 
RTE is cleared by the host. 

(TDR) Time domain reflectometer. These bits are the value of 
an internal counter which is set by the LANCE chip to count 
system clocks from the start of a transmission to the occurrence 
of a collision. This value is useful in determing the approximate 
distance to a cable fault; it is valid only when the RTE bit in 
this word is set. 



Architecture 3-1 09 



3.9.15 Transmit Buffers 

Transmit buffers are set up by the host by adding a transmit buffer 
descriptor to the network interface transmit buffer descriptor ring. These 
buffers are used for storing incoming Ethernet packets. An Ethernet 
packet may span multiple buffers, but a buffer cannot contain more than 
one Ethernet packet. The base address of a transmit buffer is formed by 
concatenating the contents of the TBDnWO and TBDnWl <7:0> (BADR). 
The size of a transmit buffer is determined by TBDnW2 <11:0>. Transmit 
buffers are structured as shown in Figure 3—71. 



151413121110 987654321 



TRANSMIT 
BUFFER 
(64-1518 BYTES ) 



~R 



:BASE 



~a 



MA-X0074-88 



Figure 3-71 Transmit Buffers 



3.9.16 LANCE Operation 

The LANCE chip operates independently of the host under control of its 
own internal microprogram. This section is a simplified description of 
the operation of the LANCE in terms of its principal microcode routines 
(these should not be confused with device driver programming in the host, 
which is not a part of this specification). These microcode routines make 
use of numerous temporary storage cells within the LANCE chip; most 
of these are not accessible from outside the chip but they are mentioned 
here when necessary to clarify the operation of the microcode. 

Two such (conceptual) internal variables are of central importance: the 
pointers to the "current" entry in the receive descriptor ring and in the 
transmit descriptor ring, which are referred to below as TXP and KXP. 
Each of these designates the descriptor which the LANCE will use for the 
next operation of that type. If the descriptor designated by one of these 
pointers is not owned by the LANCE (the OWN bit is 0), then the LANCE 
can neither perform activity of that type nor advance the pointer. 



3-110 Architecture 



For the transmit ring, the LANCE will do nothing until the host sets up a 
packet in the buffer and sets the OWN bit in the descriptor designated by 
the LANCE's TXP. (The host must keep track of the position of the TXP, 
since setting up a packet in some other descriptor will not be detected 
by the LANCE.) For the receive ring, if the LANCE does not own the 
descriptor designated by RXP, it cannot receive a packet. In both rings, 
when the LANCE finishes with a descriptor and relinquishes it to the host 
by clearing OWN, it then advances the ring pointer (modulo the number 
of entries in the ring). 

When the LANCE begins activity using the current descriptor (that is, 
begins receiving or transmitting a packet), it may look ahead at the next 
descriptor and attempt to read its first three words in advance so it can 
chain to the next buffer in mid-packet without losing data. However, it 
does not actually advance its RXP or TXP until it has cleared the OWN 
bit in the current descriptor. 

The LANCE is a very complex chip and this specification does not attempt 
to cover all the details of its operation. The chip purchase specification 
and the chip vendor's literature should also be consulted for more detailed 
information. 

3.9.16.1 Switch Routine 

Upon power on, the STOP bit is set and the INIT and STRT bits are 
cleared in NICSRO. The LANCE microprogram begins execution in the 
switch routine, which tests the INIT, STRT, and STOP bits. When the 
host sets either INIT or STRT, STOP is cleared. While STOP is set, if the 
host writes to NICSR1 and NICSR2, that data is stored for use by the 
initialization routine. 

When the microprogram sees STOP cleared, it tests first the INIT bit and 
then the STRT bit. If INIT is set, it performs the initialization routine. 
Then if STRT is set, it begins active chip operation by jumping to the 
look-for-work routine. Control returns to the switch routine whenever the 
host again sets the STOP bit (which also clears the INIT and STRT bits). 
Note that the ring pointers RXP and TXP are not altered by the setting 
of either STOP or START, they are reset to the start of their rings only 
when INIT is set. 

3.9.16.2 Initialization Routine 

The initialization routine is called from the switch routine when the latter 
finds the INIT bit set. It reads the initialization block from the memory 
addressed by NICSR1 and NICSR2 and stores its data within the LANCE 
chip. This routine also sets the ring pointers RXP and TXP to the start 
of their rings (that is, to point to the descriptor at the lowest memory 
address in the ring). 



Architecture 3—1 1 1 



3.9.16.3 Look-For-Work Routine 

The look-for-work routine is executed while the LANCE is active and 
looking for work. It is entered from the switch routine when the STRT 
bit is set, and is returned to from the receive and transmit routines after 
they have received or transmitted a packet. 

This routine begins by testing whether the receiver is enabled (bit RXON 
of NICSRO is set). If so, it tries to have a receive buffer available for 
immediate use when a packet addressed to this system arrives. It tests its 
internal registers to see whether it has already found a receive descriptor 
owned by the LANCE and, if not, calls the receive poll routine to attempt 
to get a receive buffer. 

Next the routine tests whether the transmitter is enabled (bit TXON of 
NICSRO is set). If so, it calls the transmit poll routine to see whether 
there is a packet to be transmitted and to transmit it. 

If there was no transmission and the TDMD bit of NICSRO is not set, the 
microprogram delays 1.6 milliseconds and then goes to check the receive 
descriptor status again. If a packet was transmitted or the host has set 
TDMD, the delay is omitted so that multiple packets will be transmitted 
as quickly as possible. 

If at any point in this routine the receiver detects an incoming packet 
whose destination address matches the station's physical address, is the 
broadcast address, or passes the multicast address filter (or if the PROM 
bit of NIIBWO is set), the receive routine is called. 

3.9.16.4 Receive Poll Routine 

The receive poll routine is called whenever the receiver is enabled and the 
LANCE needs a free buffer from the receive descriptor ring. The routine 
reads the second word of the descriptor designated by RXP and, if the 
OWN bit in it is set, reads the first and third words also. 

3.9.16.5 Receive Routine 

The receive routine is called when the receiver is enabled and an incoming 
packet's destination address field matches one of the criteria described 
above. The routine has three sections: initialization, lookahead, and 
descriptor update. 

In initialization, the routine checks whether a receive ring descriptor has 
already been acquired by the receive poll routine. If not, it makes one 
attempt to get the descriptor designated by RXP (if OWN is not set in it, 
MISS and ERR are set in NICSRO and the packet is lost). The buffer thus 
acquired is used by the receive DMA routine to empty the silo. 



3-112 Architecture 



In lookahead, the routine reads the second word of the next descriptor in 
the receive ring and, if the OWN bit is set, reads the rest of the descriptor 
and holds it in readiness for possible data chaining. 

The descriptor update section is performed when either the current buffer 
is filled or the packet ends. If the packet ends but its total length is less 
than 64 bytes, it is an erroneous "runt packet" and is ignored: no status is 
posted in the descriptor, RXP is not moved, and the buffer will be reused 
for the next incoming packet (this is why a receive buffer must be at least 
64 bytes long; otherwise the runt might be detected after advancing RXP). 

If the packet ends (with or without error), the routine writes the packet 
length into MCNT, sets ENP and other appropriate status bits and clears 
OWN in the current descriptor, and sets RINT in NTCSRO to signal the 
host that a complete packet has been received. Then it advances RXP and 
returns to the look-for-work routine. 

If the buffer is full and the packet has not ended, chaining is required. 
The routine releases the current buffer by writing status bits into its 
descriptor (clearing OWN and ENP, in particular), makes current the next 
descriptor data acquired in the lookahead section, advances RXP, and 
goes to the lookahead section to prepare for possible additional chaining. 
Note that RINT is not set in NICSRO, although the host would find 
OWN cleared if it looked at the descriptor, and it could begin work on 
that section of the packet, since the mutual exclusion rule prevents the 
LANCE from going back and altering it. 

3.9.16.6 Receive DMA Routine 

The receive DMA routine is invoked asynchronously by the chip hardware 
during execution of the receive routine whenever the silo contains 16 or 
more bytes of incoming data or when the packet ends and the silo is not 
empty. It executes DMA cycles to drain data from the silo into the buffer 
designated by the current descriptor. 

3.9.16.7 Transmit Poll Routine 

The transmit poll routine is called by the look-for-work routine to see 
whether a packet is ready for transmission. It reads the second word 
of the descriptor designated by TXP and tests the OWN bit. If OWN is 
zero, the LANCE does not own the buffer and this routine returns to its 
caller. If OWN is set, the routine tests the STP bit, which should be set to 
indicate the start of a packet. If STP is clear, this is an invalid packet; the 
LANCE sets its OWN bit to return it to the host, sets TINT in NICSRO to 
notify the host, and advances TXP to the next transmit descriptor. 



Architecture 3—1 1 3 



If both OWN and STP are set, this is the beginning of a packet, so the 
transmit poll routine reads the rest of the descriptor and then calls the 
transmit routine to transmit the packet. During this time the chip is still 
watching for incoming packets from the network and it will abort the 
transmit operation if one arrives. 

3.9.16.8 Transmit Routine 

The transmit routine is called from the transmit poll routine when the 
latter finds the start of a packet to be transmitted. This routine has three 
sections: initialization, lookahead, and descriptor update. 

In initialization, the routine sets the chip's internal buffer address and 
byte count from the transmit descriptor, enables the transmit DMA 
engine, and starts transmission of the packet preamble. It then waits 
until the transmitter is actually sending the bit stream (including possible 
backoff-and-retry actions in case of collisions). 

In lookahead, the transmit routine test the current descriptor to see 
whether it is the last in the packet (the ENP bit is set). If so, no 
additional buffer is required so the routine waits until all the bytes from 
the current packet have been transmitted. If not, the routine attempts 
to get the next descriptor and hold it in readiness for data chaining, 
and then waits until all the bytes from the current buffer have been 
transmitted. 

Descriptor update is entered when all the bytes from a buffer have been 
transmitted or an error has occurred. If there is no error and the buffer 
was not the last of the packet, the pre-fetched descriptor for the next 
buffer is made current for use by the transmit DMA routine. The routine 
writes the appropriate status bits and clears the OWN bits in the current 
descriptor and advances TXP. If this was the last buffer in the packet, the 
routine sets the TINT bit in NICSRO to notify the host and returns to the 
look-for-work routine. Otherwise it goes back to the lookahead section in 
this routine. 

3.9.16.9 Transmit DMA Routine 

The transmit DMA routine is invoked asynchronously by the chip 
hardware during execution of the transmit routine whenever the silo 
has 16 or more empty bytes. It executes DMA cycles to fill the silo with 
data from the buffer designated by the current descriptor. 



3-1 1 4 Architecture 



3.9.16.10 Collision Detect Routine 

This routine is invoked asynchronously by the chip hardware during 
execution of the transmit routine when a collision is detected on the 
network. It ensures that the jam sequence is transmitted, then backs 
up the chip's internal buffer address and byte count registers, waits 
for a pseudo-random backoff time, and then attempts the transmission 
again. If 15 retransmission attempts fail (a total of 16 attempts), it sends 
the microcode to the descriptor update routine to report an error in the 
current transmit descriptor (bits RTRY and ERR are set). 

3.9.17 LANCE Programming Notes 

The following are LANCE programming notes: 

1. The interrupt signal is simply the OR of the interrupt-causing 
conditions. If another such condition occurs while the interrupt signal 
is already asserted, there will not be another active transition of the 
interrupt signal and another interrupt will not be generated. An 
interrupt service routine should use logic similar to the following to 
avoid losing interrupts: 

a. Read NICSRO and save the results in a register, say R2. 

b. Clear the interrupt enable bit INEA in the saved data in R2. 

c. Write NICSRO with the saved data in R2. This will make the 
interrupt signal false because INEA is clear and will clear all the 
write-one-to-reset bits such as RINT, TINT and the error bits; it 
will not alter the STRT, INIT or STOP bits nor any interrupt- 
cause bits which came true after NICSRO was read. 

d. Write NICSRO with only INEA to enable interrupts again. 

e. Service all the interrupt and error conditions indicated by the 
flags in the data in R2. 

f. Exit from the interrupt service routine. 

2. An interrupt is signalled to the host only when the last buffer of a 
multibuffer (chained) packet is received or transmitted. However, 
the OWN bit in each descriptor is cleared as soon as the LANCE has 
finished with that portion of the packet, and the mutual exclusion rule 
makes it safe for the host to process such a descriptor and its buffer. 



Architecture 3—1 1 5 



3. When a transmitter underflow occurs (UFE is set in a transmit 
descriptor because the silo is not filled fast enough), the LANCE 
will turn off its transmitter and the LANCE must be restarted to turn 
the transmitter back on again. This can be done by setting STOP in 
NICSRO and then setting STRT in NICSRO (DTX will still be clear in 
the chip's internal copy of NIIBWO). It is not necessary to set INIT to 
reread the initialization block. 

Note that setting STOP will immediately terminate any reception 
which is in progress. If the status of a receive descriptor has been 
updated and its OWN bit is now clear, then the contents of its buffer 
are valid. If the incoming packet was chained into more than one 
buffer, however, the packet is only valid if its last buffer has been 
completed (the one with the ENP bit set). 

4. The network controller hardware requires up to five seconds after 
power on to become stable. Self-test routines must delay at least this 
time before attempting to use the controller for either internal or 
external testing. 

5. The CAE bit (loss of carrier) may be set in the transmit descriptor 
when a packet is sent in internal loopback mode. When the LANCE is 
operating in internal loopback mode and a transmission is attempted 
with a non-matching address, the LANCE will correctly reject that 
packet. If the next operation is an internal loopback transmission 
without first resetting the LANCE, the packet will not be sent and 
LCAR will be set in the transmit descriptor for that packet. The 
receive descriptor will still be owned by the LANCE. Tb avoid this 
problem, the LANCE should be reinitialized after each internal 
loopback packet. 

6. The ONE flag is occasionally set in a transmit descriptor after a late 
collision. The LANCE does not attempt a retransmission even though 
ONE may be set. The host should disregard ONE if the COE flag is 
also set. 

7. The chip's internal copy of NICSR1 may become invalid when the 
chip is stopped. The NICSR1 and NICSR2 registers should always be 
loaded prior to setting INIT to initialize the LANCE chip. 

8. Attempting an external loopback test on a busy network can cause 
a silo pointer misalignment if a transmit abort occurs while the 
chip was preparing to transmit the loopback packet. The resulting 
retransmission may cause the transmitter enable circuit to hang, 
and the resulting illegal length transmission must be terminated 
by the jabber timer in the transceiver. It is unlikely that there will 
be a corrupted receive buffer because the reception that caused the 
transmit abort will usually not pass address recognition. 



3-116 Architecture 



Since external loopback is a controlled situation it is possible to 
implement a software procedure to detect a silo pointer misalignment 
problem and prevent continuous transmissions. Since the test is being 
done in loopback the exact length and contents of the receive packet 
are known; thus the software can determine whether the data in the 
receive buffer has been corrupted. 

On transmission, the diagnostic software should allow up to 32 retries 
before a hard error is flagged. This is not to say that 32 errors are 
allowed for each condition; the sum of all errors encountered in the 
test should not exceed 32. The diagnostic software should expect 
to get a transmit done interrupt with 1 millisecond of passing the 
transmit packet to the LANCE. If this does not occur, it should 
reset the LANCE and retry the test. This prevents a continuous 
transmission (babble) longer than the longest legal packet in case the 
LANCE has become hung. 

9. When the chip is in internal loopback mode and a CRC error is forced, 
a framing error will also be indicated along with the CRC error. In 
external loopback, when a CRC error is forced only that error is 
indicated; a framing error is indicated only if the LANCE actually 
receives extra bits. 

10. When transmit data chaining, a buffer error will be set in the current 
transmit descriptor if a late collision or retry error occurred while 
the LANCE was still transmitting data from the previous buffer. The 
BUE error in this case is an invalid error indication and should be 
ignored. BUE is valid only when UFE is also set. 

11. When the host program sets up a packet for transmission in chained 
buffers, it should set the OWN bits in all the transmit buffers except 
the first one (that is, the one containing the STP bit), and then as 
its last act set the OWN bit in the first descriptor. Once that bit is 
set, the LANCE will start packet transmission and may encounter an 
underflow error if the subsequent descriptors for the packet are not 
available. 

12. Do not set INIT and STRT in NICSRO at the same time. After 
stopping the chip, first set INIT and wait for IDON, then set STRT. 
If both are set at once, corrupt transmit or receive packets can be 
generated if RENA becomes true during the initialization process. 



Architecture 3—1 1 7 



3.1 Mass Storage Interface 

The KN210 contains a DSSI bus interface which is implemented by the 
SII chip and four 32K x 8 static RAMs, and is located on the KN210 I/O 
module. The interface allows the KN210 to transmit packets of data to, 
and receive packets of data from, up to seven other DSSI devices (typically 
RF type disk drives and TF type streaming tape drives). The KN210 also 
provides DSSI bus termination. 

This interface contains 27 registers and 128 Kbytes of 32 bit wide RAM 
(MSI buffer RAM). The SII chip transfers data between the DSSI bus and 
the MSI buffer RAM, and the processor transfers data between the MSI 
buffer RAM and main memory. 

3.10.1 DSSI Bus Overview 

Some of the major characteristics of the DSSI bus are: 

• Eight bit data path 

• Eight devices supported 

• Parity checking 

• Distributed arbitration 

• Synchronous operation 

• Maximum bandwidth of 4M bytes/sec 

Communication on the DSSI bus is limited to two devices at a time. Each 
device has a unique ID assigned to it. 

When two devices communicate on the DSSI bus, one acts as the initiator, 
the other as the target. The initiator is the device that starts a DSSI bus 
transaction. The target device controls the remainder of the DSSI bus 
transaction. The direction of data flow is from the initiator to the target. 

A DSSI bus transaction consists of six phases: 

1. WAIT — During this phase, the initiator waits for the bus to become 
free. 

2. ARBITRATION— During this phase, control of the bus is taken by the 
initiator with the highest ID. 

3. SELECTION — During this phase, the initiator tries to make a logical 
connection with the target. 



3—1 1 8 Architecture 



4. COMMAND OUT— During this phase, the initiator sends the six bytes 
of command information specified in the command block to the target 
(Section 3.10.5). 

5. DATA OUT — During this phase, the initiator sends from one to 4 
Kbytes of data to the target. 

6. STATUS IN — During this phase, the target sends one byte of status 
information on the transaction to the initiator. The initiator writes 
this byte to the status word in the command block. 

A block diagram of DSSI bus sequences, showing these six phases, is 
given in Figure 3—72. 















(D 




1 


' 




ARBITRATION 




(2) 




^ 


' 




SELECTION 




(3) 




' 


' 


(4) 


COMMAND OUT 




(5) 


1 


1 


DATA OUT 


(6) 


< 


r 


STATUS IN 











MA-X0075-88 



Figure 3-72 DSSI Bus Sequences 



Architecture 3—1 1 9 



The normal path follows vertically downward. Exception paths are listed 
below: 

1. The initiator arbitrates and loses. 

2. The target failed to respond or responded with an unexpected bus 
phase. 

3. The operation was timed out or the target responded with unexpected 
phase. 

4. The target detected a parity error or information mismatch in the 
command, or the target did not have any buffer space available. 

5. The operation was timed out or the target responded with an 
unexpected phase. 

3.10.2 Target Operation 

When the KN210 is functioning as a target device, the SII chip expects 
receive buffers to be established in the 128 Kbyte MSI buffer RAM 
(addresses 1010 0000 16 through 101F FFFF 16 ). Receive buffers must 
be set up by the processor and start on 8-byte boundaries. These buffers 
consist of a command block (Section 3.10.5) and a receive data block. 
These buffers are linked together by the first word in the command block, 
and the MSIJTLP register is used to point to the first buffer in the list 
(Figure 3-73). 

During target operation, the SII chip uses the MSIJTLP register to 
determine the address of the next free receive buffer to be used for this 
DSSI bus transaction. As the SII chip fills the buffer, it will reload the 
MSIJTLP for the next target transaction with the buffer's thread word 
(the first word in the command block). The target then places the DSSI 
bus in the status in phase, sends a status byte to the initiator and updates 
the status byte in its buffer's command block. 



3-1 20 Architecture 



MSI TLP 



RECEIVE 
BUFFER #1 



COMMAND 
BLOCK 



RECEIVE 

DATA 

BLOCK 



(4K BYTES) 



: BASE 
: BASE +2 
: BASE +4 
: BASE +6 
: BASE +8 
: BASE +10 
: BASE + 12 
: BASE +14 
: BASE +16 

': BASE +4110 
: BASE +4112 



RECEIVE 
BUFFER NO.2 



ETC. 



MA-X0076-88 



Figure 3-73 Target Operation 



Architecture 3-121 



3.10.3 Initiator Operation 

When the KN210 is functioning as initiator device, the SII chip expects 
transmit buffers to be established in the 128 Kbyte MSI BUFFER RAM 
(addresses 1010 0000 i 6 through 101F FFFF 16 ). These buffers must be 
set up by the processor and start on 8-byte boundaries. These buffers 
consist of a command block (Section 3.10.5) and a transmit data block. 
These buffers are linked together by the first word in the command block, 
and the MSI_ILP register is used to point to the first buffer in the list. 

3.10.3.1 Transmit Data Segment Links 

The transmit data block is broken into one or more segments. These 
segments need not reside in contiguous locations in the MSI buffer RAM 
and are connected together by the link. Pictorially, the link appears as 
shown in Figure 3—74. 



MSILWO: 



MSILW1 



LNK 



LENGTH OF NEXT SEGMENT 



ADDRESS OF NEXT SEGMENT ( ADDRESS BITS <17:02> ) 



MA-X0077-8B 



Figure 3-74 Transmit Data Segment Links 

MSI Link Word 

A definition of the bit fields of MSI link word (MSILWO) is given below. 

Data Bit Definition 

MSILWO LNK When set, this bit indicates that there is a data segment 

<15> following the next one. When clear the next data segment is 

the last in this data block. 

MSILWO Length of next segment. This field contains the number of bytes 

<14:0> in the next data segment. 



3-1 22 Architecture 

MSI Link Word 1 

A definition of the bit field of MSI link word 1 (MSILW1) is given below. 

Data Bit Definition 

MSILW1 Address of next segment. This field contains bits <17:2> of the 

<15:0> next 8-byte aligned data segment. 

Each segment of data must be preceded by the above described link. The 
number of linked segments is only limited by the maximum size of the 
data block (4 Kbytes) (Figure 3-75). 

When the KN210 is the initiator, the SII chip uses the MSI_IPL register 
to determine the address of the transmit buffer to be used for this DSSI 
transaction. As the SII chip is processing a transmit buffer, it loads an 
internal register with the second word of the link word as long as the 
LNK is enabled. This chaining continues until a LNK value of zero is 
encountered. The SII will then transfer the next segment and deposit 
the status of the entire transfer in the status area of the command block. 
The MSI_IPL register is then loaded with the buffer's thread word (the 
first word in the command block) for the next initiator operation. If an 
error of any kind occurs during the processing of a transmit buffer, the 
SII will stop the transmit operation by clearing the output enable bit 
MSI.DSCTRL <14>. 

3.10.4 Adding to a Buffer List 

The following enumerates the method required to dynamically add new 
buffers to the MSI_TLP and MSI.IPL lists: 

1. Fill in the new buffer command block and ensure that the MSB of the 
status word is zero. 

2. Make the thread word of the new buffer zero. 

3. Replace the thread word of the last item on either the MSI_IPL or 
MSI_TLP list with the new thread word, pointing to the new buffer. 

4. If the MSIJPL or MSI.TLP is zero, load it with the address of the 
new buffer. 



MSI IPL 



X 



NEXT TRANSMIT 
BUFFER 



Architecture 3-123 



TRANSMIT 
BUFFER #1 



COMMAND 
BLOCK 



LINK 



DATA SEG 



LINK 



DATA SEG 



: BASE 
: BASE +2 
: BASE +4 
: BASE +6 
: BASE +8 
: BASE +10 
: BASE +12 
: BASE +14 



TRANSMIT 
} DATA BLOCK 



J 



MA-X0078-88 



Figure 3-75 Initiator Operation 



3—1 24 Architecture 



3.10.5 Mass Storage Interface Command Block (MSICB) 

The MSI command block is a 12 byte data structure that the processor has 
to build at the start of all transmit and receive buffers in the MSI buffer 
RAM. The format for the MSI command block is shown in Figure 3-76. 

15 



MSICBWO 


THREAD WORD 


: BASE +0 


MSICBW1 


STATUS WORD 


: BASE +2 


MSICBW2 


COMMAND WORD 


: BASE +4 


MSICBW3 
MSICBW4 
MSICBW5 


COMMAND BYTES 


: BASE +6 
: BASE +8 
: BASE +10 






MA-X0079-88 



Figure 3-76 MSI Command Block 

3.10.5.1 MSI Command Block Word 

Word of the MSI command block (MSICBWO), also referred to as the 
thread word, resides in the MSI buffer RAM at the base address of the 
MSI command block. The thread word contains bits <17:2> of the base 
address of the next buffer. Bit of this field must always be set to 0, since 
buffers must start on an 8-byte boundary. A thread word of zero indicates 
that there are no more buffers. The format for MSICBWO is shown in 
Figure 3-77. 



15 



MSICBWO 



NEXT BUFFER ADDRESS < 17:2 > 



:BASE +0 



MA-X0085-88 



Figure 3-77 MSI Command Block Word 



Architecture 3—125 



3.10.5.2 MSI Command Block Word 1 

Word 1 of the MSI command block (MSICBW1), also referred to as the 
status word, resides in the MSI buffer RAM at the base+2 address of each 
MSI command block. This word indicates the status of the current DSSI 
transaction and is used by the processor to find out which buffers the 
SII chip has finished processing. The format for MSICBW1 is shown in 
Figure 3-78. 



MSICBW1 



UNUSED 



DNE — ' 



RST 
TMO 

XSM 

BPH 
STT 
PHS 
DSA 
PAR 



BASE+2 



MA-X0O80-88 



Figure 3-78 MSI Command Block Word 1 

The bit fields in MSICBW1 represent the following: 



Data Bit 



Definition 



MSICBW1<15> (DNE) Done. When set, this indicates that the SII chip has 

used this buffer (either successfully or not). When clear the SII 
chip has not used this buffer. Note, if this bit is set when the 
SII chip begins processing a buffer, the buffer is not used. 



MSICBW1<14:8> Unused. 

MSICBW1<7> (RST). Reset. When set, a DSSI device reset the DSSI bus 
during this buffer's transaction. 

NOTE 

If a DSSI bus reset occurred before the SII chip reached 
status in phase, the SH chip will clear MSI_DSCTRL <7> 
(output enable bit) and interrupt the processor without 
writing any status. 



3—1 26 Architecture 



Data Bit 



Definition 



MSICBW1<6> (TMO) Timeout. When set, one of the MSI_DSTMO timers has 
expired. 

NOTE 

If the timeout occurred before the SEE chip reached 
status in phase, the SH chip will clear MSI_DSCTRL<7> 
(output enable bit) and interrupt the processor without 
writing any status. 

MSICBW1<5> (XSM) Checksum. When set, the received checksum does not 
agree with that computed by the SII chip. Note the XSM bit is 
only valid when the KN210 is a target. 

MSICBW1<4> (BPH). Bad phase. When set, an illegal DSSI phase was 

entered by the target. Note the BPH bit is only valid when 
the KN210 is the initiator. 

MSICBW1<3> (STT) Status. When set, ACK was not returned by the target. 
Note the STT bit is only valid when the KN210 is the initiator. 

MSICBW1<2> (PHS) Phase. When set, the DSSI bus phase changed before 

the initiator expected. Note the PHS bit is only valid when the 
KN210 is the initiator. 

MSICBW1<1> (DSA). DSSI. When set, the target detected an error in the 
command bytes. Note the DSA bit is only valid when the 
KN210 is the target. 

MSICBW1<0> (PAR). Parity. When set, a parity error on the DSSI bus was 
detected. 



Please note that the following cases will not cause status to be written in 
memory: 

• DSSI bus reset occurs before status in phase is reached. 

• Initiator selects a non-existent device (initiator timeout will cause a 
DSSI bus reset). 

• Target disconnects from the DSSI bus before status in phase is 
reached. 



Architecture 3-127 



3.10.5.3 MSI Command Block Word 2 

Word 2 of the MSI command block (MSICBW2), also referred to as the 
command word, resides in the MSI buffer RAM at the base+4 address of 
each MSI command block. This word contains information regarding the 
transfer. The format for MSICBW2 is shown in Figure 3-79. 



15 14 3 2 10 

MSICBW2 



UNUSED 



: BASE+4 



IE J DEST J 

ID 

MA-X0081 -88 



Figure 3-79 MSI Command Block Word 2 

The bit fields in this memory word represent the following: 

Data Bit Definition 

MSICBW2<15> (IE). Interrupt enable. When set, the SII chip will interrupt 
the KN210 upon the completion (successful or not) of this 
transaction. When clear the SII chip will not generate an 
interrupt. Interrupts are posted on IRQ2 at IPL16 with a 
vector offset of C5 i6- 

MSICBW2<14:3> Unused. 

MSICBW2<2:0> (DEST ID). Destination ID. The ID of the target to be selected. 
This field is only used when the KN210 is the initiator. 



3-1 28 Architecture 



3.10.5.4 MSI Command Block Words 3-5 

Words 3-5 of the MSI command block (MSICBW3-5), also referred to as 
command bytes, reside in the MSI buffer RAM at the base+6 through 
base+10 address of each MSI command block. These 6 bytes are sent out 
during the command out phase by the initiator. Some of the information 
contained in these bytes are: 

• The target and initiator IDs 

• The number of data bytes which will be transferred by the initiator in 
the data out phase 

• The DSSI opcode. 

3.10.6 MSI Registers 

The following is a description of the 16 registers needed to control the SII 
chip during DSSI bus operations. 

NOTE 

The other 11 registers are not used during DSSI operations and 

should not be accessed. 

3.10.6.1 MSI Control and Status Registers 

These five registers are used to configure, control and monitor the SII 
chip. 

MSI Control/Status Register 

The MSI control/status register (MSI.CSR) (address 1008 460C 16 ) 
contains control and status information about the general operation of 
the SII chip in regard to the DSSI bus, including various enable bits. The 
format of the mass storage control/status register is shown in Figure 3-80. 



Architecture 3-129 



31 5 


4 


3 


2 




1 







UNUSED 










MBZ 

SLE 










PCE — 






IE 









MA-X0082-88A 



Figure 3-80 MSI Control/Status Register 



Data Bit Definition 



MSI_CSR Unused. Reads return undefined results, writes have no 

<31:5> effect. 

MSI_CSR <4:3> (MBZ) Must be zero. Read/Write. These bits must read as 
zero and be written as zero. 

MSI_CSR <2> (SLE) Selections. Read/Write. When set, the SII chip will 

respond to selections. When clear the SII chip will not 
respond to an initiator trying to select it. Cleared on power- 
up, or on the assertion of IORESET. 

MSI_CSR <1> (PCE) Parity check. Read/Write. When set, the SII chip 

reports parity errors. When clear the SII chip will continue 
to check parity but will not report any errors during the 
status in phase. Cleared on power-up, or on the assertion of 
IORESET. 

MSI_CSR <0> (IE) Interrupt enable. Read/Write. When set, interrupts are 

enabled. The SII chip posts interrupts when an error occurs 
or at the end of a transaction (successful or not). Interrupts 
are posted on IRQ2 at IPL16 with an offset of C5 i6. When 
clear interrupts are disabled. Cleared on power-up, or on the 
assertion of IORESET. 



3-1 30 Architecture 



MSI DSSI Control Register 

The MSI DSSI control register (MSI_DSCTRL) (address 1008 4644 16 ) 
contains information to control the SII chip. The format of the mass 
storage interface DSSI control register is shown in Figure 3—81. 



31 



15 14 13 



'8 76543210 



UNUSED 



UNUSED 



DSE 
OUT 



CH7 
CH6 
CH5 
CH4 
CH3 
CH2 
CH1 
CHO 



MA-XO083-88 



Figure 3-81 MSI DSSI Control Register 



Data Bit 



Definition 



MSI.DSCTRL 
<31:16> 

MSI DSCTRL <15> 



MSI DSCTRL <14> 



MSI.DSCTRL 
<13:8> 



Unused. Reads return undefined results. Writes have no 
effect. 

(DSE) DSSI Enable. Read/Write. This bit must be set to 
one by the processor for the SII chip to work on a DSSI 
bus. This bit is cleared by the SII chip if: the SII chip 
selects or is selected by a non-DSSI device, the SII chip is 
selected with Attention. It is also cleared on power-up, or 
on the assertion of IORESET. 

(OUT) Output enable. Read/Write. When set, the SII chip 
is enabled to send transmit buffers. This bit is cleared by 
the SII chip if: the MSI_IPL becomes zero, the initiator 
timer MSI_DSTMO <3:0> expires, or a transmit buffer is 
not terminated with ACK. It is also cleared on power-up, 
or on the assertion of IORESET. 

Unused. Reads return undefined results, writes have no 
effect. 



Architecture 3—131 



Data Bit 



Definition 



MSI DSCTRL <7> 



MSI DSCTRL <6> 



MSI DSCTRL <5> 



MSI DSCTRL <4> 



MSI DSCTRL <3> 



MSI DSCTRL <2> 



MSI_DSCTRL <1> 



MSI DSCTRL <0> 



(CH7) Channel 7. Read/Write. This bit is used to 
determine if device 7 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CH6) Channel 6. Read/Write. This bit is used to 
determine if device 6 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CH5) Channel 5. Read/Write. This bit is used to 
determine if device 5 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CH4) Channel 4. Read/Write. This bit is used to 
determine if device 4 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CH3) Channel 3. Read/Write. This bit is used to 
determine if device 3 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CH2) Channel 2. Read/Write. This bit is used to 
determine if device 2 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CHI) Channel 1. Read/Write. This bit is used to 
determine if device 1 is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 

(CHO) Channel 0. Read/Write. This bit is used to 
determine if device is a DSSI device. This bit must 
be set to one by the processor. Cleared on power-up, or on 
the assertion of IORESET. 



3-1 32 Architecture 



MSI DSS1 Connection Register 

The MSI DSSI connection register (MSI.CSTAT) (address 1008 4648 16 ) 
contains interrupt status related to SII chip connections. The format 
of the mass storage interface DSSI connection register is shown in 
Figure 3-82. 

31 16151413121110 9 8765432 10 



UNUSED 



CI 
UNU 
RST 
BER 
OBC 

TZ 
BUF 
LDN 
SCH 
CON 
DST 
TGT 
SWA 
SIP 
LST 
MBZ 



MA-X0084-88 



Figure 3-82 MSI DSSI Connection Register 



Architecture 3-133 



Data Bit 



Definition 



MSI_CSTAT Unused. Reads return undefined results, writes have no 

<31:16> effect. 

MSI_CSTAT (CI) Composite interrupt. Read only. This bit is the 

<15> composite error bit of the MSI_CSTAT register. It is the 

logical OR of bits MSI_CSTAT <13:11> and MSI_CSTAT 
<9:7>. When set, the processor will be interrupted on 
IRQ2 at IPL16 with a vector offset of C5 i6 if interrupts 
are enabled. Cleared on power-up, or on the assertion of 
IORESET. 

MSI_CSTAT (UNU) Unused. Reads return undefined results, writes have 

<14> no effect. 

MSI_CSTAT (RST) Reset asserted. Read/Write one to clear. When set, 

<13> the DSSI bus was reset by one of the eight DSSI devices. 

The SII chip will automatically disconnect itself from the 
bus and interrupt the processor on IRQ2 at IPL16 with an 
offset of C5 i6- This bit is write one to clear and is also 
cleared on power-up, or on the assertion of IORESET. 

MSI_CSTAT (BER) Bus error. Read/Write one to clear. This bit is set to 

<12> one on any of the following conditions: 

• Buffer overflow 

• Req/Ack offset exceeded 

• Illegal phase change 

While this bit is asserted, the SII chip will not receive or 
transmit data. This bit is write one to clear and is also 
cleared on power-up, or on the assertion of IORESET. 



3—134 Architecture 



Data Bit 



Definition 



MSI_CSTAT 
<11> 



MSI_CSTAT 
<10> 

MSI CSTAT <9> 



MSI CSTAT <8> 



MSI CSTAT <7> 



MSI CSTAT <6> 



(OBC) OUT_EN Bit cleared. Read/Write one to clear. This 
bit is set to one on any of the following conditions: 

• The SII chip has received RSTIN. (The DSSI bus has 
been reset.) 

• The MSLDSTMO (MSI_DSTMO <3:0> or MSI_DSTMO 
<7:4>) has expired. 

• As an initiator, the attached target disconnects 
unexpectedly. 

This bit is write one to clear and is also cleared on power-up, 
or on the assertion of IORESET. 

(TZ) Target pointer zero. Read only. When set, the MSI_ 
TLP register contains a value of zero. This bit is set on 
power-up, or on the assertion of IORESET. 

(BUF) Buffer service. Read/Write one to clear. When set, 
the SII chip has begun processing a transmit buffer destined 
for non-DSSI device. Note, this bit should always be zero 
since all devices must be DSSI. This bit is write one to 
clear and is also cleared on power-up, or on the assertion of 
IORESET. 

(LDN) List element done. Read/Write one to clear. When 
interrupts are enabled, this bit is set if the SII chip has 
completed a buffer, successfully or not. This bit is write one 
to clear and is also cleared on power-up, or on the assertion 
of IORESET. 

(SCH) State change. Read/Write one to clear. Set if MSI_ 
DSCTRL <15> is cleared causing the SII chip to leave DSSI 
mode. This bit is write one to clear and is also cleared on 
power-up, or on the assertion of IORESET. 

(CON) Connected. Read only. When set, the SII is 
connected to another device on the DSSI bus. Clear while 
the SII chip is not connected to another device on the DSSI 
bus. This bit is cleared on power-up, or on the assertion of 
IORESET. 



Architecture 3—1 35 



Data Bit 



Definition 



MSI_CSTAT <5> 



MSI CSTAT <4> 



MSI.CSTAT <3> 



MSI CSTAT <2> 



MSI CSTAT <1> 



MSI CSTAT <0> 



(DST) Destination. Read only. When set, the SII is the 
destination of the current transaction. In other words, this 
bit is set if the SII chip was selected by another device on 
the DSSI bus. This bit is cleared on power-up, or on the 
assertion of IORESET. 

(TGT) Target. Read only. When set, the SII chip is 
operating as a target during the current transaction. This 
bit is cleared on power-up, or on the assertion of IORESET. 

(SWA) Selected with attention. Read only. When set, the 
SII chip was selected with attention. This bit is write one to 
clear and is also cleared on power-up, or on the assertion of 
IORESET. 

(SIP) Selection in progress. Read only. When set, the SII 
chip is currently in a selection process. This is useful in 
determining if the desired target is unavailable. This bit is 
write one to clear and is also cleared on power-up, or on the 
assertion of IORESET. 

(LST) Lost. Read only. When set, the SII lost arbitration. It 
is cleared by the SII chip when it begins a selection process 
and on power-up or on the assertion of IORESET. 

(MBZ) Must be zero. Read Only. This bit will be read as 
zero. 



MSI ID Register 

The MSI ID register (MSIJD) (address 1008 4610 i 6 ) contains the three 
bit ID number of the KN210 on the DSSI bus. This value is placed on 
the DSSI bus during the selection phase so the target knows who selected 
it. The format of the mass storage interface ID register is shown in 
Figure 3-83. 



3-1 36 Architecture 



31 




16 


15 


14 


3 


2 


1 





UNUSED 




UNUSED 










I/O - 








KN210 BUS ID - 









MA-X0086-88A 



Figure 3-63 MSI ID Register 



Data Bit Definition 



MSI_ID Unused. Reads return undefined results, writes have no effect. 

<31:16> 

MSI_ID <15> (I/O) Input/Output. Read/Write. When set, the KN210's ID is 
determined by MSIJD <2:0>. When clear the KN210's ID is 
determined by on board jumpers and MSIJD <2:0> will reflect 
the one's complement of the KN210's DSSI ID. Cleared on 
power-up, or on the assertion of IORESET. Note that if this bit 
is cleared, writing to this register has no effect. 

MSI_ID Unused. Reads return undefined results, writes have no effect. 

<14:3> 

MSI_ID <2:0> KN210 Bus ID. Read/Write. When MSIJD <31> is clear (the 

normal operation configuration), this field contains the DSSI ID 
of the KN210, as determined by the on board jumpers. When 
MSIJD <31> is set, any DSSI ID value may be input (used, for 
example, to temporarily override the on board jumpers for test 
or diagnostic purposes). Indeterminate on power-up, or on the 
assertion of IORESET. 



MSI DSSI Timeout Register 

The MSI DSSI timeout register (MSI.DSTMO) (address 1008 461C 16 ) 
contains the timeout values of the SII chip for both the initiator and 
target roles. Also contained in this register is a single enable bit that 
governs both timers. The format of the MSI DSSI timeout register is 
shown in Figure 3-84. 



31 



16 1514 



Architecture 3—1 37 



876543 210 



UNUSED 




UNUSED 






ENA - 






TARGET 
TIMEOUT-J 


INIT 
TIMEOUT— I 



VALUE 



VALUE 



MA-X0087-88 



Figure 3-84 MSI DSSI Timeout Register 



Data Bit 



Definition 



MSI_DSTMO 
<31:16> 

MSI_DSTMO <15> 



MSI_DSTMO 
<14:8> 

MSI DSTMO <7:4> 



MSI DSTMO <3:0> 



Unused. Reads return undefined results, writes have no 
effect. 

(ENA) Enable. Read/Write. When set, both the DSSI 
target and DSSI initiator timers are enabled. When 
clear, both the DSSI target and DSSI initiator tinier are 
disabled. Cleared on power up, or on the assertion of 
IORESET. 

Unused. Reads return undefined results, writes have no 
effect. 

Target timeout value. Read/Write. This field contains the 
number of 200 microsecond intervals which may elapse 
while the KN210 is the target. The timer starts from 
the point when the KN210 was selected ends at the next 
observed bus free phase. Cleared on power_up, or on the 
assertion of IORESET. 

Initiator timeout value. Read/Write. This field contains 
the number of 200 microsecond intervals which may 
elapse, from the last observed bus free phase, until the 
next observed bus free phase, while the KN210 is in the 
initiator role; or the number of 200 microsecond intervals 
which may elapse before the KN210, acting as a potential 
initiator, detects a bus free phase. Should the timer 
expire under either of these two conditions the SII chip 
will assert a DSSI bus reset. Cleared on power_up, or on 
the assertion of IORESET. 



3-1 38 Architecture 



3.10.6.2 List Pointer Registers 

These are the two registers used as address pointers for next incoming 
and outgoing data buffers. 

MSI Target List Pointer Register 

The MSI target list pointer register (MSIJTLP) (address 1008 463C 16 ) 
contains the address to which the SII chip will write the next free receive 
buffer. The SII chip will automatically reload the register with the receive 
buffer's thread word upon completion of the current transaction. Note this 
register must contain bits <17:2> of an 8-byte aligned address, therefore 
bit will always be zero. The SII chip will interpret an address of 0000 
16 as the end of a linked list. The format of the MSI target list pointer 
register is shown in Figure 3-85. 

31 16 15 10 



UNUSED 



ADDRESS OF NEXT FREE 
RECEIVE BUFFER 



MBZ - 

MA-X0088-88 



Figure 3-65 MSI Target List Pointer Register 



Data Bit Definition 



MSIJTLP Unused. Reads return undefined results, writes have no 

<31:16> effect. 

MSIJTLP <15:1> Address of next incoming buffer. Read/Write. This field 

contains bits 17:3 of the 8-byte aligned address to where the 
SII chip will find the next free receive buffer. Cleared on 
powerup, or on the assertion of IORESET. 

MSIJTLP <0> (MBZ) Must be zero. Read/Write. This bit is read as zero 

and must be written as zero. 



NOTE 

This register can only be written by the processor when the 
register is zero or MSIJDSCTRL <15> (DSE) is clear; all other 
attempts to 'write to this register have no effect. 



Architecture 3-1 39 



MSI Initiator List Pointer Register 

The MSI initiator list pointer register (MSI.IPL) (address 1008 4640 16 ) 
contains the address from which the SII chip will find the next transmit 
buffer. The SII chip will automatically reload this register with the 
transmit buffer's thread word upon completion of the current transaction. 
Note this register must contain bits <17:2> of an 8-byte aligned address, 
therefore bit must always be zero. The SII chip will interpret an address 
of 0000 i6 as the end of a linked list. The format of the MSI initiator list 
pointer register is shown in Figure 3-86. 

31 1615 1 



UNUSED 



ADDRESS OF NEXT 
TRANSMIT BUFFER 



MBZ- 

MA-X0089-88 



Figure 3-86 MSI Initiator List Pointer Register 



Data Bit Definition 



MSI_IPL <31:16> Unused. Reads return undefined results, writes have no 
effect. 

MSI_IPL <15:1> Address of next outgoing buffer. Read/Write. This field 

contains bits 17:3 of the 8-byte aligned address of where 
the SII chip will find the next transmit buffer. Cleared on 
power_up, or on the assertion of IORESET. 

MSI_TLP <0> (MBZ) Must be zero. Read/Write. This bit will read as zero 

and must be written as zero. 



NOTE 

This register can only be written to by the processor when the 
register is zero or MSIJDSCTKL <15> (DSE) is clear; all other 
attempts to write to this register have no effect. 

3.10.6.3 Diagnostic and Test Registers 

This group of registers is used for test and diagnostic purposes only. They 
should never be used during normal operation. 



3—140 Architecture 



MSI Diagnostic Control Register 



The MSI diagnostic control register (MSI.DICTRL) at (address 1008 
4654 ig) allows the SII chip to be placed in one of three diagnostic test 
modes. The format of the MSI diagnostic control register is shown in 
Figure 3-S7. 



31 4 


3 


2 


1 





UNUSED 










ITM ' 








ELM 




TST 





MA-X0090-B8 



Figure 3-87 MSI Diagnostic Control Register 



Data Bit 



Definition 



MSI_ 
DICTRL<31:4> 

MSI_DICTRL<3> 



MSI DICTRL<2> 



Unused. Reads return undefined results. Writes have no 
effect. 

(ITM) Internal test mode. Read/Write. When set, the values 
written to MSI_DR0, MSI_DR1 and MSI_DR2 are to be 
looped back into the chip. This will enable the processor to 
insert test vectors into the chip during power-up diagnostics. 
Note that the MSI_DICTRL<1> (ELM) must be deasserted 
for this test to be meaningful. This bit is cleared on power- 
up, or on the assertion of IORESET. 

(PRE) Port enable. Read/Write. When set, the off-chip 
drivers to the DSSI port are enabled. After a reset, the 
KN210 will be disconnected from the bus (this bit will be 
zero). The primary purpose of this bit is to allow SII chip 
diagnostics to run without affecting the rest of the DSSI 
bus (PRE=0). This bit is cleared on power-up, or on the 
assertion of IORESET. 



Architecture 3—141 



Data Bit 



Definition 



MSI DICTRL<1> 



MSI DICTRL<0> 



(ELM) External loopback mode. Read/Write. When set, the 
SII chip is in external loopback mode. In this mode, MSI_ 
DRO, MSI_DR1 and MSI_DR2 are used to directly control 
the DSSI data and control lines, as well as the external bus 
transceiver. Note an external loopback connector must be 
in place when using this test mode. This bit is cleared on 
power-up, or on the assertion of IORESET. 

(TST) Test mode. Read/Write. When set, to one (1), the SII 
chip is in test mode. This enables the user to replace the 
20 MHz clock. The new clock is pulsed each time the MSI_ 
CLOCK register is written. This bit is cleared on power-up, 
or on the assertion of IORESET. 



MSI Diagnostic Register 

The MSI diagnostic register (MSIJDRO) (address 1008 4600 16 ) is used 
during internal and external loopback diagnostic tests. The fields in this 
register are used to emulate the data lines of the DSSI. The format of 
MSI diagnostic register is shown in Figure 3—88. 



31 



9 8 7 



UNUSED 




DATA <7:0 > 


PTY 







MA-X0091-88 



Figure 3-88 MSI Diagnostic Register 



Data Bit 



Definition 



MSI_DR0 <31:9> 
MSI DRO <8> 



Unused. Reads return undefined results, writes have no 
effect. 

(PTY) Parity. Read/Write. This bit contains the parity bit 
for the data byte MSI_DR0 <7:0>. Indeterminate on power- 
up, or on the assertion of IORESET. Note, parity checking is 
only enabled if MSI_CSR <1> PCE is set to 1. The SII chip 
uses odd parity checking. 



3—1 42 Architecture 



Data Bit 



Definition 



MSI DRO <7:0> 



(DATA) Read/Write. This field contains the current byte 
on the data bus. Indeterminate on power-up, or on the 
assertion of IORESET. 



NOTE 

MSI_DR0 should NOT be used during normal operation. 

MSI Diagnostic Register 1 

The MSI diagnostic register 1 (MSIJDR1) (address 1008 4604 16 ) is 
used during internal and external loopback tests. In external loopback 
mode an external loopback connector in place allows values written into 
MSI_DR0 to be read back in MSI_DR1 and values written into MSI_ 
DR1 to be read back in MSI_DR0. In internal loopback mode it acts as 
the DSSI bus emulating some of the DSSI control lines. Note that all 
the control lines are asserted high in internal loopback test mode. For 
more information on the SII chip modes see the description of the MSI 
diagnostic control register. The format of MSI diagnostic register 1 is 
shown in Figure 3-89. 



UNUSED 
















BSY 


















RST 






ACK 






RFO 










ATN 




MSB 






cm 






I/O 





MA-X0092-88 



Figure 3-89 MSI Diagnostic Register 1 



Architecture 3—143 



Data Bit Definition 



MSI_DR1 <31:9> Unused. Reads return undefined results, writes have no 
effect. 

MSI_DR1 <8> (BSY) Busy. Read/Write. In internal loopback test mode, 

MSI_DICTRL <3> set, this bit emulates the DSSI BSY 
bus signal. In external loopback mode this bit is linked to 
MSI_DR0 <8> (PTY) for driver testing. Indeterminate on 
power-up, or on the assertion of IORESET. 

MSI_DR1 <7> (SEL) Select. Read/Write. In internal loopback test mode, 

MSI_DICTRL <3> set, this bit emulates the DSSI SEL bus 
signal. In external loopback mode this bit is linked to MSI_ 
DRO <7> (DATA <7>) for driver testing. Indeterminate on 
power-up, the negation of DCOK when SCR <7>. 

MSIJDR1 <6> (RST) Reset. Read/Write. In internal loopback test mode, 

MSI_DICTRL <3> set, this bit emulates the DSSI RST bus 
signal. In external loopback mode this bit is linked to MSI_ 
DRO <6> (DATA <6>) for driver testing. Indeterminate on 
power-up, or on the assertion of IORESET. 

MSI_DR1 <5> (ACK) Acknowledge. Read/Write. In internal loopback 

test mode, MSI_DICTRL <3> set, this bit emulates the 
DSSI ACK bus signal. In external loopback mode this bit 
is linked to MSI_DRO <5> (DATA <5>) for driver testing. 
Indeterminate on power-up, or on the assertion of IORESET. 

MSI_DR1 <4> (REQ) Request. Read/Write. In internal loopback test mode, 

MSI_DICTRL <3> set, this bit emulates the DSSI REQ 
bus signal. In external loopback mode this bit is linked to 
MSI_DRO <4> (DATA <4>) for driver testing. Indeterminate 
on power-up, or on the assertion of IORESET. 

MSI_DR1 <3> (ATN) Attention. Read/Write. In internal loopback test 

mode, MSI_DICTRL <3> set, this bit emulates the DSSI 
ATN bus signal. In external loopback mode this bit is 
linked to MSI_DR0 <3> (DATA <3>) for driver testing. 
Indeterminate on power-up, or on the assertion of IORESET. 

MSI_DR1 <2> (MSG) Message. Read/Write. In internal loopback test 

mode, MSI_DICTRL <3> set, this bit emulates the DSSI 
MSG bus signal. In external loopback mode this bit is 
linked to MSI_DR0 <2> (DATA <2>) for driver testing. 
Indeterminate on power-up, or on the assertion of IORESET. 



3—1 44 Architecture 



Data Bit Definition 



MSI_DR1 <1> (C/D) Control/Data. Read/Write. In internal loopback test 

mode, MSI_DICTRL <3> set, this bit emulates the DSSI C/D 
bus signal. In external loopback mode this bit is linked to 
MSI_DR0 <1> (DATA <1>) for driver testing. Indeterminate 
on power-up, or on the assertion of IORESET. 

MSI_DR1 <0> (I/O) Input/Output. Read/Write. In internal loopback test 

mode, MSI_DICTRL <3> set, this bit emulates the DSSI I/O 
bus signal. In external loopback mode this bit is linked to 
MSI_DRO <0> (DATA <0>) for driver testing. Indeterminate 
on power-up, or on the assertion of IORESET. 

NOTE 

The data written to this register in internal test mode may 

differ from that read back from it, since only certain bits are 

driven when configured as a target or initiator. See the register 

description of MSIJDR2 for more information on the internal test 

mode. 

MSI Diagnostic Register 2 

The MSI diagnostic register 2 (MSI_DR2) (address 1008 4608 16 ) is used 
by diagnostics to directly control the DC563 transceiver chip. The format 
of the MSI diagnostic register 2 is shown in Figure 3-90. 



31 4 


3 


2 


1 




UNUSED 










IGS — 














SBE 







MA-X0093-88 



Figure 3-90 MSI Diagnostic Register 2 



Architecture 3—1 45 



Data Bit Definition 



MSI_DR2 <31:4> Unused. Reads return undefined results. Writes have no 
effect. 

MSI_DR2 <3> (IGS) Read/Write. This bit enables the DSSI bus drivers 

for ACK and ATN, placing the SII chip in the initiator role. 
Cleared on power-up, or on the assertion of IORESET. 

MSI_DR2 <2> (TGS) Read/Write. When set, this bit enables the DSSI bus 

drivers for I/O, C/D, MSG and ATN, placing the SII chip in 
the target role. Cleared on power-up, or on the assertion of 
IORESET 

MSI_DR2 <1> (ARB) Arbitrate. Read/Write. This bit enables the decoding 

of ID0..ID2, putting the SII chip in the arbitration phase. 
Cleared on power-up, or on the assertion of IORESET. 

MSI_DR2 <0> (SBE) Read/Write. When set, the DC563 transceiver drives 

the DSSI data bus and parity lines. Cleared on power-up, 
or on the assertion of IORESET. 



NOTE 

Special care should be taken when writing to the MSI.DR2 
register to avoid disturbing the DSSI bus during power-up 
diagnostics. This register should only be used when an external 
loopback connector is in place and not during normal operation. 

MSI Clock Control Register 

Writing to the MSI clock control register (MSI_CLOCK), address 1008 
4658 i6, generates a pulse which, in test mode (MSI_DICTRL <0> set to 
one), replaces the 20 MHz clock input. This can be used to allow the CPU 
to observe and sequence the various state machines inside the SII chip. 
The format of the MSI clock control register is shown in Figure 3—91. 

31 



UNUSED 



MA-X0094-88 



Figure 3-91 MSI Clock Control Register 



3-1 46 Architecture 



Data Bit Definition 



MSI_CLOCK Unused. Write only. Writing to this register generates a 

<31:0> pulse which, in test mode (MSI_DICTRL <0> set to one), 

replaces the 20 MHz clock input. 



MSI Internal State Registers (0-3) 

These registers, at addresses 1008 465C 16 , 1008 4660 i 6 , 1008 4664 
16, and 1008 4668 i6, reflect the status of the SII chip's internal state 
machine when used in test mode (that is, MSIJDICTRL <0> set to one). 



4 



KN210 Firmware 



This chapter describes the functional operation of the KN210 firmware. 
This firmware is used to provide an easy means to configure and bootstrap 
a KN210-based system and to detect and isolate system malfunctions. 

The firmware described in this chapter resides on the KN210 processor 
module. The KN210 is an R3000-based Q22-bus CPU module set. 

The KN210 provides a maximum of 256 Kbyte of EPROM for the 
firmware. The firmware resides on the KN210 processor module in two 
128 Kbyte EPROMs (one per processor), which are arranged as 32-bit 
words and located at the R3000 restart location at physical address 1FC0 
0000 and the diagnostic processor restart location at physical address 
2004 0000. 

The firmware uses the KN210 module LEDs and a console terminal to 
communicate diagnostic progress, display error conditions, and indicate 
the current mode of operation. Additionally, the console terminal is used 
as the primary operator interface when in console I/O mode. 

NOTE 

A console terminal is not required for operation, since the module 
set can be configured to bootstrap automatically. However, in 
most scenarios a console terminal is a recommended part of a 
standard configuration. 

The KN210 firmware runs standalone, and does not require other 
software products for normal operation in console I/O mode. However, 
in most situations an operating system (or other image) is loaded in 
KN210 local memory and control is transferred to it. When the operating 
system is running, the processor is in program I/O mode. (The terms 
console I/O mode and program I/O mode refer to the context and usage 
of the console terminal.) 



4-1 



4-2 KN210 Firmware 



The KN210 supports ULTRIX. Additionally, the firmware supports 
bootstrap of MDM and other diagnostics images. Also, the console 
supports communication with an APT host in manufacturing 
environments through the console serial line. 

KN210 firmware is an integral part of the module and does not require 
installation or support services. 

4.1 Firmware Capabilities 

The KN210 firmware provides the following services: 

• Diagnostics that test all components on the board and verify the 
module is working correctly. 

• Automatic/manual bootstrap of an operating system following 
processor halts. 

• Automatic/manual restart of an operating system following processor 
halts. 

• An interactive command language that allows the user to examine 
and alter the state of the processor. 

The remainder of this chapter describes in detail the functions and 
external characteristics of the KN210 firmware. 

4.2 Power-Up 

On power-up, the KN210 firmware performs initial power-up tests, locates 
and identifies a console device, and performs the remaining diagnostics. 
Certain power-up actions are dependent on the state of the Operation 
and Function switches on the H3602-SA panel. The various functions 
determined by the Operation and Function switches are described in 
Section 4.2.3. 

4.2.1 Initial Power-Up Test 

At power-up, the diagnostic processor performs the Initial Power-Up Test 
(IPT). The purpose of the IPT is to verify that the console private NVRAM 
is valid and if invalid to test and initialize the NVRAM. 

If the NVRAM contains invalid data, the IPT will initialize certain non- 
volatile data, such as the default boot device, to a known state. In any 
case, the IPT then initializes other data structures and performs a 
processor initialization. If the mode switch is set to Test, the IPT then 
tests the console serial line. 



KN210 Firmware 4-3 



NOTE 

All EPT failures are considered fatal, and the KN210 will hang 
with a value on the LEDs indicating the point of failure. Refer to 
Table 4-2 for the meaning of the LEDs. 

4.2.2 Locating a Console Device 

After the diagnostic processor IPT has completed successfully, the 
firmware attempts to locate a console device and find out what type of 
device it is. Normally, this is the device attached to the console serial 
line. In this case, the firmware will send out a device attributes escape 
sequence to the console serial line to determine the type of terminal 
attached and the functions it supports. Terminals that do not respond 
to the device attributes request correctly are assumed to be hardcopy 
devices. 

NOTE 

The KN210 is always an arbiter CPU and the console serial line is 

unconditionally treated as the system console. 

Once a console device has been found, the firmware displays the KN210 
banner message, similar to the following: 

KN210-A VO.O 

The banner message contains the processor name and the version of 
the firmware. The letter code in the firmware version indicates whether 
the firmware is pre-field test (X), field test (T) or an official release (V). 
The first digit indicates the major release number and the trailing digit 
indicates the minor release number. 

4.2.3 Operation and Function Switches 

The operation and function switches tell the KN210 to perform 
maintenance functions or to continue with the bootstrap process. 

The operation switch has three settings: Normal, Maintenance and 
Action. When in normal mode, the function switch positions are break 
enabled and break disabled. If in maintenance mode, the function switch 
positions are break enabled and break disabled. If the position of the 
operation switch is set to action, the function switch positions are test and 
query. 



4-4 KN210 Firmware 

The operation and function switches are described in Table 4—1. 
Table 4-1 Operation and Function Switches 

Operation Function 

Switch Switch 

Mode Symbol Position Symbol 

Normal -*■ 



Maintenance 



Action 



break enabled 


© 


break 


6 


disabled 




break enabled 


© 


break 


6 


disabled 




test 


© 


query 


6 



4.2.3.1 Operation Switch Set to Normal 

When the operation switch is set to normal the diagnostic processor 
executes the power up diagnostics. In addition to message text, a 
countdown is displayed to indicate diagnostic test progress. A successful 
diagnostic countdown is shown in Example 4—1. 

Performing normal system tests. 

49. .48. .47.. 46.. 45. .44.-43. .42.. 41 

33.. 32. .31.. 30.. 29. .28.. 27. .26. .25 

17. .16. .15.. 14.. 13. .12.. 11. .10. .09 

Tests completed. 

Memory Size: xxxxxxxx (OXxxxxxxxx) bytes 

Ethernet Address : xx-xx-xx-xx-xx-xx 



Example 4-1 Normal Diagnostic Countdown 

After the diagnostics are executed, control is passed to the R3000 
processor through BIT 31 of the select processor register (SPR) in the 
KN210 processor (Section 4.2.4.1), and the R3000 processor continues 
with the power-up sequence. 



40. 


.39. 


.38. 


.37. 


.36. 


.35. 


.34 


24. 


.23. 


.22. 


.21. 


.20. 


.19. 


.18 


08. 


.07. 


.06. 


.05. 


.04. 


.03. 


. 



KN210 Firmware 4-5 



If the operation switch is set to normal and the environment variable 
bootmode is set to a, the R3000 processor attempts to find a booting 
device specified by the setenv command through the bootpath 
environment variable stored in non-volatile memory (Section 4.3.2). 

When the operation switch is set to normal and the environment variable 
bootmode is not initialized or it is set to d, the R3000 enters console I/O 
mode and displays the R3000 console prompt (») to prompt the user for 
commands. Refer to Section 4.4 for console command descriptions. 

If there are diagnostic failures, a diagnostic register dump is performed 
similarly to Example 4—2. The remaining diagnostics execute, the 
countdown continues, and the KN210 enters maintenance mode 
(Section 4.2.3.2). For a detailed description of the register dump refer 
to Section 4.5. 

Performing normal system tests. 

49. .48. .47.. 46. .45. .44. .43. .42. .41. .40. .39. .38. .37. .36. .35. .34. . 

?34 2 08 FF 00 0000 

P1=00000000 P2=00000003 P3=00000031 P4=00000011 P5=00002000 
P6=FFFFFFFF P7=00000000 P8=00000000 P9=00000000 P10=2005438F 
rO=00114B98 rl=FFFFFFFF r2=2005D2F0 r3=55555555 r4=AAAAAAAA 
r5=00000000 r6=AAAAAAAA r7=00000000 r8=00000000 ERF=80000180 
33. .32. .31. .30.. 29. .28. .27. .26. .25. .24. .23. .22. .21. .20. .19. .18. . 
17. .16. .15.. 14. .13. .12.. 11. .10. .09. .08. .07.. 06. .05. .04. .03. . 
Normal operation not possible. 
>» 



Example 4-2 Abnormal Diagnostic Countdown 

4.2.3.2 Operation Switch Set to Maintenance 

When the operation switch is set to maintenance, the diagnostic processor 
executes the power-up diagnostics. In addition to message text, a 
countdown is displayed to indicate diagnostic test progress. A successful 
diagnostic countdown is shown in Example 4—1. 

After the diagnostics are executed, the KN210 enters maintenance mode 
and displays the diagnostic processor console prompt (>») to prompt the 
user for commands (Section 6.2.7). 



4-6 KN210 Firmware 



4.2.3.3 Operation Switch Set to Action 

Two different operations are possible when the operation switch is set to 
action: test and query. 

Function Switch Set to Test 

If the function switch is set to test, the console serial line external 
loopback test is executed at the end of the IPT. The purpose of this test is 
to verify that the console serial line connections from the KN210 through 
the H3602-SA panel are intact. 

NOTE 

An external loopback connector should be inserted in the serial 
line connector on the H3602-SA panel before cycling power to 
invoke this test. 

During this test the firmware toggles between the two states: active and 
passive, for a few seconds each with each displaying a different number 
on the LEDs. 

During the active state (about 3 seconds long), the LEDs are set to 7. In 
this state, the firmware reads the baud rate and operation switch, then 
transmits and receives a character sequence. If the operation switch has 
been moved from the action position, the firmware exits the test and 
continues as if on a normal power-up. 

During the passive state (about 7 seconds long), the LEDs are set to 3. 

If at any time the firmware detects an error (parity, framing, overflow or 
no characters), the firmware hangs with a 7 displayed on the LEDs. 

Function Switch Set to Query 

If the KN210 designated console device supports DEC multinational 
character set (MCS) and either the NVRAM data is invalid or the 
function switch is set to query the firmware prompts for the console 
language. The firmware first displays the language selection menu shown 
in Example 4—3. 

After the language query, the firmware invokes the ROM-based 
diagnostics, and the firmware enters normal mode if the diagnostics 
are passed successfully. However, if the diagnostics fail, the firmware 
enters maintenance mode. 



KN210 Firmware 4-7 



1 

2 


Dansk 

Deutsch (Deutschland/Osterreich) 


3 


Deutsch (Schweiz) 


4 


English (United Kingdom) 


5 


English (United States/Canada) 


6 


Espafiol 


7 


> Frangais (Canada) 


8 


Frangais (France/Belgique) 


9 


Frangais (Suisse) 


10 


Italiano 


11 


Nederlands 


12 


Norsk 


13 


► Portugues 


14 


) Suomi 


15 


Svenska 


( 


L. .15) : 



Example 4-3 Language Selection Menu 

If no response is received within 30 seconds, the language defaults to 
English (United States/Canada). 

NOTE 

This action is only taken if the console device supports DEC MCS. 
Any console device that does not support DEC MCS, such as a 
VT100, defaults to English (United States/Canada). 

After this inquiry, the firmware proceeds to autoboot. 

4.2.3.4 LED Codes 

In addition to the console diagnostic countdown a hexadecimal value is 
displayed on the diagnostic LEDs on the processor module and the H3602- 
SA panel. The purpose of the LED display is to improve fault isolation, 
when there is no console terminal or when the hardware is incapable of 
communicating with the console terminal. Table 4—2 lists all LED codes 
and the associated actions that are performed at power-up. The LED code 
is changed before the corresponding test or action is performed. 



4-8 KN210 Firmware 



Table 4-2 LED Codes 



LED 

Value Actions 



F Initial state on power-up, no code has executed 

E Entered ROM, some instructions have executed 

D Waiting for power to stabilize (POK) 

C SSC and ROM tests 

B Diagnostic processor tests 

A R3000 tests 

9 CMCTL and memory tests 

8 CQBIC (Q22-bus) tests 

7 Console loopback tests 

6 DSSI subsystem tests 

5 Ethernet subsystem tests 

4 Diagnostic processor console I/O mode 

3 R3000 console I/O mode 

2 Diagnostic processor primary/secondary bootstrap 

1 R3000 primary/secondary bootstrap 

Operating system running 



4.2.4 Interprocessor Interaction 

The R3000 and the diagnostic processor can each select the other 
processor to start or continue execution. This is accomplished through 
the SPR register (Section 4.2.4.1). 



KN210 Firmware 4-9 



4.2.4.1 Select Processor Register Operation 

The select processor register (SPR) determines which processor is active. 
This is a write-only register. 

If the diagnostic processor writes a 1 to the SPR (diagnostic processor 
executes the command EXIT), the diagnostic processor hangs on a DMA 
grant and the R3000 begins execution. 

If the R3000 writes a to the SPR (R3000 executes the command maint), 
the R3000 hangs on a RDBUSY or WRBUSY stall and the diagnostic 
processor begins execution. 

4.2.5 Power-Up Sequence 

The KN210 power-up sequence depends on whether the processor is in 
normal mode or in maintenance mode. 

4.2.5.1 Normal Power-Up Operation 

When the KN210 is set to operate in normal mode, the power-up sequence 
algorithm is as shown in Example 4—4. 

1 . Diagnostic processor powers-up (begins execution at a location pointed 
to by 2004 0000) 

2 . Diagnostic processor runs self test diagnostics 

3. Diagnostic processor executes EXIT command (SPR set to 1) 

4 . Diagnostic processor hangs on a DMA grant 

5. R3000 begins execution at an address stored in 1FC0 0000. 

- if the bootmode environment variable is set to ' a' 

R3000 attempts to auto_boot 

if bootpath environment variable is valid 

the auto_boot succeeds 
else 

the R3000 waits for a command at 

its prompt ( » ) 

- if the bootmode environment variable is not initialized 

(*) or if it is set to ' d' 

the R3000 waits for a command at 
its prompt ( » ) 

- when the R3000 waits for a command at its prompt 

( » ) console commands can be received 

if the command is maint (SPR is set to 0) then 

- The R3000 hangs on a RDBUSY stall. 

- The diagnostic processor resumes execution. 



Example 4-4 Normal Power-Up Sequence Algorithm 



4-10 KN210 Firmware 



4.2.5.2 Maintenance Power-Up Operation 

When the KN210 is set to operate in maintenance mode, the power-up 
sequence algorithm is as shown in Example 4—5. 

1 . Diagnostic processor powers-up (begins execution at a location pointed 
by 2004 0000) 

2 . Diagnostic processor runs self test diagnostics 

3 . Diagnostic processor enters console mode (diagnostic processor waits for 
a command at its prompt ( >» ) ) 

- console commands can be received 

if the command is EXIT (SPR is set to 1) then 

- The diagnostic processor hangs on a DMA grant 

- The R3000 begins execution 



Example 4-5 Maintenance Power-Up Sequence Algorithm 
4.2.6 Processor Identification 

The KN210 provides the Sys_Type read only register at physical location 
2004 0004 in the diagnostic processor firmware EPROM and through the 
R3000 environment variable systype, described in Section 4.4.2.3. 

4.2.6.1 Sys_Type Register Layout 

The layout of the SysJIype register is shown in Figure 4—1. The Sys_Type 
register address is 2004 0004. 



Figure 4-1 System Type Register 



KN210 Firmware 4-11 



Field Name 



RW Description 



31:24 



SYS_ 
TYPE 



23:16 VERSION ro 



15:8 SYS_ ro 

SUB_ 
TYPE 

7:0 HARDWARE ro 



This field identifies the type of system for a specific 
processor. (Reads as 06 for the KN210.) 

This field identifies the resident version of the 
firmware EPROM encoded as two hexadecimal 
digits. For example, if the banner displays V5.0, 
then this field is 50 (hex). 

This field identifies the particular system sub-type. 
(Reads as 01 for the KN210.) 



This field identifies the hardware revision level. 



4.3 Operating System Bootstrap 

Bootstrapping is the process of loading and transferring control to 
an operating system. The KN210 supports bootstrap of UL/TRIX- 
32. Additionally, the KN210 will boot MDM diagnostics and any user 
application image which conforms to the boot formats described in this 
manual. 

On the KN210, a bootstrap occurs whenever a boot command is issued 
at the console in maintenance or normal mode or whenever the processor 
halts and the conditions specified in Section 4.3.7 for automatic bootstrap 
are satisfied. 



4.3.1 MDM Bootstrap 

MDM is booted by the diagnostic processor when in maintenance mode 
and when the BOOT command is executed at the diagnostic processor 
console prompt. 

For a detailed description of the diagnostic processor boot process, refer to 
Chapter 6. 



4-12 KN210 Firmware 



4.3.2 Operating System Bootstrap 

The operating system is booted by the R3000 when in one of the following 
states: 

• The operation switch is in the normal position and the environment 
variable bootmode is set to a. 

• The operation switch is in the normal position and the environment 
variable bootmode is undefined or set to d and the boot command is 
typed. 

• The operating system initiates a reboot operation. 
One of three ports may be used for bootstrapping: 

• KN210 I/O board Ethernet controller 

• KN210 I/O board DSSI controller 

• KN210 Q22-bus MSCP or TMSCP controller 

Refer to Section 4.7 for a list of the supported devices. 

The disk and tape bootstrap code has no knowledge of any file structure 
on disks or tapes. Because of this, the operating system must provide an 
image capable of being loaded through the boot block that in turn loads 
the remainder of the operating system. 

The Ethernet bootstrap code is capable of booting using the MOP Ethernet 
bootstrap protocol. BOOTP is not supported. 

The boot code allows the operator to set the default bootstrap device 
and file name by storing them in a non-volatile environment variable 
(REFERENCE>(ENVIRONMEOT_VARIABLES)). Once set, the system 
normally uses this default for bootstraps. However, the operator can 
override the default manually. 

The boot code interface also provides for command extension through 
the bootstrap mechanism. If after parsing a command line the boot code 
interface fails to recognize a keyword that begins a command, it looks for 
the environment variable path and if it finds the path, it prepends the 
value of path to the keyword and attempts to boot the resulting filename. 
Any remaining arguments following the initial keywords are passed as 
arguments to the program after it is loaded. 



KN210 Firmware 4-13 



4.3.3 Boot Process 

The boot process is as follows: 

1. Determine the device to be booted from parsing the boot command or 
from the bootpath environment variable. 

2. If the process is initiated by the boot command, set the bootpath 
environment variable to the boot device in non-volatile memory. 

3. Open the boot device and read block zero (Figure 4r-2). 

4. Read the sequence of blocks described in the bootblock into main 
memory. 

5. Transfer control to the loaded code at the start address found on the 
bootblock. Arguments supplied through the boot command are passed 
using the C-language (argc,argv) conventions. A pointer to the current 
environment table is also passed. 

6. Any exception in this process forces the boot code to display the 
console prompt. 



RESERVED 



RESERVED 



SIGNATURE 



BOOT BLOCK TYPE 



PROGRAM LOAD ADDRESS 



PROGRAM START ADDRESS 



PROGRAM BLOCK COUNT 



PROGRAM STARTING BLOCK ADDRESS 



MA-X0613-8O 



Figure 4-2 Bootblock Layout 



4-14 KN210 Firmware 



4.3.4 Bootstrap Support Routines in the Console 

The ULTRIX bootstrap loader contains no code for performing I/O or 
machine dependent operations. Instead, the loader calls a set of routines 
provided by the console. The address of these routines are contained in a 
transfer vector located in console ROM. All routines are called as normal 
C routines using the R3000 calling conventions. 

The entry point routines can be grouped as follows: 

• console - Invoke console program restarts, reboots, and so on 

• saio - I/O support for standalone programs. Raw device I/O 

• machine - Machine specific functions (cache flushes, interlock memory 
references, and so on) 

• libc - Subset of the C library (strings, getenv, and so on) 

• parser - Access to console command parser 

• commands - Access to subset of console commands 
Section 4.6 describes the console entry points. 

4.3.5 Console Use of Memory Space 

The KN210 console reserves the bottom 64 Kbytes of physical address 
space visible from ksegl. The 64 Kbytes are partitioned as follows: 



Table 4-3 


Console Memory Space 


Address 


O/S Interface 


Console Program 


Starting 
Ending 


0000 0000 
0000 0500 


0000 04FF 
0000 FFFF 



The operating system interface region is used to hold the boot block and 
the current exception handling code. 

The console program region is used to hold the console program stack and 
static data structures. 



KN210 Firmware 4-15 



4.3.6 Boot Devices 

Three types of boot media are supported: disk, tape and Ethernet. When 
specifying a boot device, the following syntax is used: 

dev(controller, unit, partition) 

The dev field is a device mnemonic. The controller and unit fields specify 
the hardware controller and unit number of the device. The partition field 
specifies a software managed partition of the device. Partitions are only 
meaningful for disk devices. If not specified, controller, unit and partition 
default to zero. The parentheses are always required. 

4.3.6.1 Disk 

Only DSSI and MSCP disks are supported. A simple bootblock bootstrap 
is supported from disk. If the disk is partitioned, a bootblock per partition 
is possible. 

rf( ) and ra( ) 

4.3.6.2 Tape 

Only TMSCP tapes are supported. A simple bootblock bootstrap is 
supported from tape. 

tm() 

4.3.6.3 Ethernet 

Bootstrapping over the Ethernet is a very important bootstrap function. 
The MOP protocol is used for network bootstraps. 

mop() 

This is a standard Digital bootstrap protocol. With MOP, either the client 
or the server may specify the file to be downloaded. If the client supplies 
a file specification, then that file is provided by the server. If the client 
does not supply a file specification, then the server determines the file 
from a database of registered clients. In the latter case, the client must 
be known to the server and be in its data base. In the former case, the 
only restriction is that the file be known to the server. 



4-16 KN210 Firmware 



4.3.7 Halts 

The R3000 processor does not provide a halt input to unconditionally 
call the console program. The KN210 has a hardware halt interrupt at 
hardware interrupt request (IRQ) 5 (Section 3.1.4). The operating system 
interrupt handler must call the console at the PROM_HALT entry point. 
Interrupts must be left disabled. The console program will save the 
machine state and restore in response to the continue command. 

Table 4-4 describes the R3000 registers that are saved when the PROM_ 
HALT entry point is called. The continue command first restores the 
R3000 registers to the saved values and then restarts the operating 
system at the saved return address in register ra. 

Table 4-4 PROM_HALT Saved Registers 

Register Name Register Name 

$2..$3 v0..vl $4..$7 a0..a3 

$16..$23 s0..s7 $26..$27 kO-kl 

$28 gp $29 sp 

$30 fp $31 ra 

cO sr cause 



The use of the maint command while the R3000 is in console I/O mode 
destroys the saved machine state. If the operating system is halted 
and maintenance mode is invoked, a subsequent attempt to restart the 
operating system will cause unpredictable results. 

NOTE 

Entering maintenance mode after an R3000 operating system 

destroys the saved machine state. 

The maintenance mode halt process is described in Chapter 6. 



KN210 Firmware 4-17 



4.4 KN21 Console Command Language 

The following sections describe the console command language. 

4.4.1 Maintenance Mode Console Command Language 

When in maintenance mode, the KN210 console command language 
interface is the same as for the KA640 console language. One additional 
command is implemented, the Exit command. The command has no 
arguments and has the effect of switching the KN210 from maintenance 
mode to normal mode. Refer to Chapter 6 for a detailed description of the 
maintenance mode console commands. 

4.4.2 Normal Mode Console Command Language 

When the KN210 is in normal mode and in console I/O mode, it will read 
and interpret commands received on the console terminal. The commands 
are based on the DECstation 3100 (PMAX) command language. 

4.4.2.1 Control Characters 

Certain ASCII control characters have special meaning when typed on the 
console terminal. These characters are described in Table 4—5. 

Table 4-5 Control Characters 

Character Function 



Return 



Ends a command line. Command characters are 
buffered until a carriage-return is received. 



Delete | Deletes the previously typed character. If the console 

terminal is defined as hardcopy (environment variable 
term set to hardcopy) the deleted text is echoed 
surrounded by backslashes. If the console terminal 
is a CRT (environment variable term set to crt) each 
delete is echoed with the sequence "<BSxSPxBS>". 
Deletes received when there are no characters to be 
deleted are ignored. 

Causes the console to abort processing of a command. 



Ctrl C 



4-18 KN210 Firmware 



Table 4-5 (Cont.) Control Characters 



Character 



Function 



Ctrl 1 10| 




Ctrl | |Q| 




Ctrl | |R| 


Ctrl | 


Ctrl| |U| 


I^M 



Cau ses console output to be discarded until the next 



Ctrl O is entered, or until the next console prompt or 



error message is issued. Ctrl| O is also cancelled when 



Ctrl | O is typed. 



Resu mes console output that was suspended by 



Ctrl S 



Causes the current command line to be displayed, 
omitting any deleted characters. 



Suspends output on the console terminal until |Ctrl| |Q| 
is typed. 

Discards all characters accumulated for the current 
line. 

Supresses any special meaning associated with the 
next character. 



4.4.2.2 Lexical Conventions 

The console is case insensitive with respect to parsing commands but case 
is preserved when assigning values to environment variables. 

All console commands are specified using US ASCII characters only. 
Values entered for environment variables however may contain any 8-bit 
character code. 

Numeric values may be entered as decimal, hexadecimal, octal, and 
binary values. Decimal values are represented by a string of decimal 
digits with no leading zeros (123). Octal values are represented by 
a string of octal digits and a leading zero must be present (0177). 
Hexadecimal values are represented by hexadecimal digits preceded with 
a "Ox" (0x3ff). Binary values are represented by binary digits preceded 
with a "Ob" (OblOOl). 



KN210 Firmware 4-19 



4.4.2.3 Environment Variables 

The KN210 console makes use of environment variables to pass 
information to the operating system. Some of the environment variables 
are maintained in non- volatile RAM so that their contents are not lost 
when power is removed. 

Additional environment variables may be denned by the operator or 
are defined automatically by the console program but they are lost 
when power is lost. The environment variables shown in Table 4—6 are 
maintained in non-volatile memory. 



Table 4-6 Environment Variables 



Variable 



Type 



Function 



baud 1 



bootpath 



init 



bootmode 



bitmap 1 


init 


bitmaplen 1 


init 


osconsole 1 


init 


console 


nvram 



Baud rate of the console terminal line. Read only. 
Possible values are 300, 600, 1200, 2400, 4800, 
9600, 19200, and 38400. 

A string containing the complete boot path 
specification. The boot path has two fields; 
the boot device (Section 4.3.6), and the 
bootpath. An example of a bootpath definition 
is: ra(0,0,0)moon_lander. 

A one character code controlling what action the 
console is to take on power-up or following a 
reset. Two codes are defined: a for autoboot, and 
d to halt after performing power-up diagnostics. 
Allowable console devices are tty(0) for console 
serial line. 

The hexadecimal address of good pages bitmap. 

The length of the memory bitmap. 

Always tty(0). 

Always selects tty(0). 



lr These environments variables are read only. Attepts to write from console I/O have no 
effect. 



4-20 KN210 Firmware 



Table 4-6 (Cont.) Environment Variables 



Variable TyP e Function 



systype 1 init Read only. Contains information used to identify 

the processor. Bits 24:31 contain the CPU type. 
Bits 16:23 contain the system type (6 for the 
KN210). Bits 8:15 contain the firmware revision 
level and bits 0:7 contain the hardware version 
level. 

1 These environments variables are read only. Attepts to write from console I/O have no 
effect. 



4.4.2.4 Commands 

The commands documented below are accepted by the console. 

? 

? [command- list] 

Identical to the help command. 
BOOT 

boot [-f file] [-s] [-n] [args] 

Boot loads the file following the flag -f . If the -f flag is not specified, then 
the file specified by the environment variable bootpath is loaded. If -s 
is specified, the operating system is booted in single user mode. If -n is 
specified, then the file is loaded but control is not passed to the program. 
If any arguments are present, then they are passed to the booted image 
using the standard argc/argv mechanism. If any argument begins with a 
(-) then it must be preceded with an additional (-) character. 

CONTINUE 

continue 

The continue command causes the processor to begin execution at the 
address currently in the saved program counter. The processor state 
saved at the last console entry is restored before leaving console mode. 



KN210 Firmware 4-21 



D 

d f-bhw] address value 

D deposits a single byte, halfword or word value at the indicated address. 
DUMP 

dump [-Bcdoux] [-bhw] range 

Dump performs a formatted display of the contents of memory. Memory 
contents may be displayed (simultaneously) in hex (-x), unsigned decimal 
(-u), octal (-o), decimal (-d), as ASCII characters (-c), or as binary (-B). 
Memory contents may be dumped as bytes (-b), halfwords (-h), or words 
(-w). The range of memory to be dumped may be specified as base-address 
(a single value is dumped) base-address#count (a specified number of 
values are dumped) or base-address:limit-address (all values between the 
base address and the limit address are dumped). 

E 

e [-bhw] address 

E displays the byte, halfword, or word at address. 

FILL 

fill [-bhw] [-walue] range 

Fill sets the range of memory specified to the value specified. If no value 
is specified, then zero is used. Memory contents may be filled as bytes 
(-b), halfwords (-h), or words (-w). The range of memory to be filled is 
specified as in the dump command. 

GO 

go [entry] 

Go transfers control to the indicated entry point address. If no entry 
address is supplied, then the entry point of the last program module 
loaded is used. 



4-22 KN210 Firmware 
HELP 

help [command- list] 

Help displays a brief synopsis of the indicated command. If no command 
list is supplied then console displays a synopsis of each command. 

INIT 

init 

Init performs a full initialization. The effect is identical to that performed 
at power-up or reset except that no diagnostics are executed. 

MAINT 

maint 

This command causes the console to enter maintenance mode. Any saved 
program state is discarded. 

PRINTENV 

printenv [variable-list] 

Printenv displays the indicated environment variable on the console 
terminal. If no variable is specified, all console environment variables are 
displayed. 

SETENV 

setenv variable value 

Setenv assigns a value to the indicated environment variable. 
UNSETENV 

unsetenv variable 

Unsetenv removes -the indicated variable from the set of console 
environment variables. The environment variables stored in non-volatile 
memory are not affected by this command. 



KN210 Firmware 4-23 



4.5 Diagnostics 

The ROM based diagnostics constitute a major portion of the firmware 
on the KN210. These diagnostics run automatically on power-up when 
in maintenance mode, and can be executed interactively as a whole, or 
as individual tests. Refer to Chapter 6 for further information on KN210 
diagnostics. 

4.6 PROM Entry Points 

The following entry points are defined in the KN210 PROM. This 
information is provided here only as a general guide as to what functions 
are available. All routines are called as normal C routines. The normal C 
conventions are assumed. 

4.6.1 Argvize 

Breaks a string into tokens and returns the number of tokens. The value 
returned by Argvize is slp.strcnt (argc) and slp->strptrs is the address of 
vector of strings (argv). 



struct string_list{ 
char *strptrs[MAXSTRINGS] 
char * strbuf [ STRINGBYTES ] 
char *strp; 
int strcnt; 

int 

argvize (str , sip) 

char * str; 

struct string_list *slp; 



/* Vector of string pointers */ 

/* Strings themselves */ 

/* Free ptr in strbuf. */ 

/* Number of strings in strptrs . */ } 



4.6.2 Atob 

Converts ASCII to binary. Accepts all C numeric input formats. Returns 
pointer to any unconverted substring left after the numeric conversion. 



char * 

atob (str, intp) 



4-24 KN210 Firmware 



4.6.3 Autoboot 



Perform automatic bootstrap. Unlike reboot, the bootstrap is 
unconditional (although bootpath must be defined). If the autoboot fails, 
control passes to the console. 

void 
autoboot ( ) 

4.6.4 Bevexcept 

Primitive exception handler for exceptions that occur while BEV bit is 
still set in system status register. Not a C routine. 

bevexcept ( ) 

4.6.5 Bevutlb 

Primitive exception handler for exceptions that occur while BEV bit is 
still set in system status register. Not a C routine. 

bevutlb () 

4.6.6 Close 

Close a file. 

int 

close (fd) 
int fd; 

4.6.7 Dumpcmd 

Invokes the console dump command. Returns if successful, 1 if not. 

int 

dumpcmd (argc, argv) 

int argc ; 

char **argv; 



KN210 Firmware 4-25 



4.6.8 Exec 

Loads a new program image. 

void 
exec () 

4.6.9 Getchar 

Inputs a single character from the current console device. 

int 
getchar ( ) 

4.6.10 Getenv 

Returns the value of a console environment variable. 

Char * 
getenv (name) 
char *name; 

4.6.11 Gets 

Gets a line of input from the console and places it in the caller's buffer. 
Normal line editing functions are performed on input. The address of the 
buffer is returned. 

char * 
gets (buf ) 
char *buf; 

4.6.12 Halt 

Saves the machine state and enters console I/O mode. 

halt 

4.6.13 Help 

Invokes the console help command. Returns if successful, 1 if not. 

help 



4-26 KN210 Firmware 

4.6.14 loctl 

Performs a device or file system specific operation on a device or file. 

int 

ioctl (f d, cmd, arg) 

int fd; 

int cmd; 

int arg; 

4.6.15 Longjump 

Terminates execution in current context and continues from context saved 
in jmp_buf by a previous setjmp. Execution resumes with rval as the 
value returned from setjmp. 

longjump ( jmp_buf , rval) 
struct jmp_buf *jmp_buf; 
int rval; 

4.6.16 Lseek 

Positions a file into an arbitrary byte position and returns the new 
position as int. 

int 

lseek (fd, offset, direction); 

int fd; 

int offset; 

int direction; 

4.6.17 Open 

Opens the indicated filename. 

int 

open (filename, flags) 

char * filename; 

int flags; 



KN210 Firmware 4-27 



4.6.18 Parser 

Inputs a command line from the console terminal, argvizes it and looks 
up the first token in the command table. If it is found, invokes the 
corresponding command with the standard argc/argv argument list. If 
the command is not found in the command table and search_path is not 
null, then attempts to perform the command by "exec'ing" the file specified 
by the concatenation of search_path and the first token. 

struct cmd__table { 

char *name; /* Command name */ 

int (* routine) () ; /* Command routine */ 

char * us age; /* Command usage string. */ 
} 

int 

parser (cmd__table, prompt, search_path) 

struct cmd_table *cmd__table; 

char *prompt; 

char *search_path; 

4.6.19 Printenvcmd 

Invoke the console printenv command. Returns if successful, 1 if not. 

int 

printenvcmd (argc, argv) 

int argc; 

char *argv; 

4.6.20 Print! 

Prints formatted values on the current console device. 

void 

printf (fmt, va_alist) 

char *fmt; 

va_dcl 

4.6.21 Putchar 

Outputs a single character to the current console device. 

void 

putchar (c) 
char c; 



4-28 KN210 Firmware 

4.6.22 Puts 

Outputs a string to the current console device. 

void 
puts(s) 
char * s ; 

4.6.23 Range 

Parses a console range specification and returns the base address and the 
count. Returns if the range is of the form address :address, 1 if the range 
is of the form address#cnt, and minus 1 if the range cannot be parsed. 

int 

range (str, basep, cntp) 

char *str; 

unsigned *basep; 

unsigned *cntp; 

4.6.24 Read 

Read data from a file into a buffer. Return the actual number of bytes 
read to the caller 

int 

read(fd, buf, cnt) 

int fd; 

char *buf; 

int cnt; 

4.6.25 Reboot 

Performs automatic test and reboots system if bootmode is a, otherwise 
enters console. The effect of this routine is to duplicate the normal console 
power-up/reset boot decision. 

void 
reboot ( ) 



KN210 Firmware 4-29 

4.6.26 Reinit 

Re-initializes the console monitor and enters command mode. 

reinit () 

4.6.27 Reset 

Enter the prom at its entry point, the result is the same as if the reset 
button had been pressed or the power switch turned on. 

void 
reset () 

4.6.28 Restart 

Re-enters the console monitor without re-initializing it. 

void 
restart ( ) 

4.6.29 Setenv 

Sets the value of an environment variable. 

int 

setenv (name , value ) 
char *name; 
char * value; 

4.6.30 Setenvcmd 

Invokes the console setenv command. Returns if successful, 1 if not. 

int 

setenvcmd (argc, argv) 

int argc; 

char **argv; 



4-30 KN210 Firmware 



4.6.31 Setjmp 

Saves the current register context in jmpjbuf and then returns zero. 
Later, a call to longjump causes the saved context to be restored and 
execution resumes again, this time with the return value specified by the 
longjump routine. Used to regain control from exceptional conditions. 

typedef jmp_buf[ll]; /* Register context */ 

int 

set jmp ( jmp_buf ) 

jmp_buf jmp_buf; 

4.6.32 Showchar 

Outputs a single character to the current console device. Displays all 
printing characters normally. Displays blanks as "\b", form feeds as 
"\f , newlines as "\n", returns as "\r", tabs as "\t". Display any other 
nonprinting character as "\xxx" where xxx is the octal code for the 
character. 

void 

showchar (c) 
char c; 

4.6.33 Strcat 

Concatenates string 1 and string 2, returning a pointer to the result. 

char * 

strcat (strl, str2) 

char *strl; 

char *str2; 

4.6.34 Strcmp 

Compares string 1 and string 2. Returns if they are the same, a 
negative value if string 1 is less than string 2, a positive value if string 1 
is greater than string 2. 

int 

strcmp (strl, str2) 

char *strl; 

char *str2; 



KN210 Firmware 4-31 



4.6.35 Strcpy 

Copies string 2 to string 1 and returns a pointer to the first unmodified 
character in string 1. String 1 must be long enough to contain string 2. 

char * 

strcpy (strl, str2) 

char *strl; 

char *str2; 



4.6.36 Strlen 

Returns the number of bytes in a string. 

int 

strlen (str) 

char *str; 

4.6.37 Unsetenvcmd 

Delete an environment variable. 

int 

unsetenvcmd (argc, argv) 

int argc; 

char *argv; 

4.6.38 Write 

Write data from a buffer into a file. Return the actual number of bytes 
written to the caller. 

int 

write (f d, buf , cnt) 

int fd; 

char *buf; 

int cnt; 



4-32 KN210 Firmware 



4.7 Supported Devices 

The KN210 firmware supports operating system bootstrapping from the 
following devices: 

Table 4-7 KN210 Boot Devices 

Name Protocol Unit Type 



rf 


DSSI 


0-7 


Disk 


ra 


MSCP 


0-3 


Disk 


tm 


TMSCP 


0-3 


Tape 


mop 


MOP 




Ethernet 



The DSSI and NI adaptors are in the KN210 I/O module. The MSCP 
devices are attached to the Q22-bus. 

NOTE 

Only Q22-bus MSCP or TMSCP devices are supported by the 

console bootstrap procedure. 



5 

Diagnostic Processor 



5.1 Diagnostic Processor 



The diagnostic processor of the KN210 is implemented by a VLSI chip 
called the CVAX. 



5.1 .1 Processor State 

The processor state consists of that portion of the state of a process that is 
stored in processor registers rather than in memory. The processor state 
is composed of sixteen general purpose registers (GPRs), the processor 
status longword (PSL), and the internal processor registers (IPRs). 

Non-privileged software can access the GPRs and the processor status 
word (bits <15:00> of the PSL). The IPRs and bits <31:16> of the PSL can 
only be accessed by privileged software. The IPRs are explicitly accessible 
only by the move to processor register (MTPR) and move from processor 
register (MFPR) instructions that can be executed only while running in 
kernel mode. 

5.1.1.1 General Purpose Registers 

The KN210 diagnostic processor implements 16 GPRs. These registers 
are used for temporary storage, as accumulators, and as base and index 
registers for addressing. These registers are denoted RO - R15. The bits of 
a register are numbered from the right <0> through <31> (Figure 6-1). 



5-1 



5-2 Diagnostic Processor 



31 30292827262524232221 201918171615141312 11 10 9 


8 


7 


6 


5 


4 


3 


2 


1 





















I 















































Figure 5-1 General Purpose Register Bit Map 

Certain of these registers have been assigned special meaning by the 
VAX- 11 architecture: 

• R15 is the program counter (PC). The PC contains the address of the 
next instruction byte of the program. 

• R14 is the stack pointer (SP). The SP contains the address of the top 
of the processor defined stack. 

• R13 is the frame pointer (FP). The VAX- 11 procedure call convention 
builds a data structure on the stack called a stack frame. The FP 
contains the address of the base of this data structure. 

• R12 is the argument pointer (AP). The VAX- 11 procedure call 
convention uses a data structure called an argument list. The AP 
contains the address of the base of this data structure. 

Consult the VAX Architecture Reference Manual for more information on 
the operation and use of these registers. 

5.1.1.2 Processor Status Longword 

The PSL is saved on the stack when an exception or interrupt occurs 
and is saved in the process control block (PCB) on a process context 
switch. Bits <15:00> may be accessed by non-privileged software, while 
bits <31:16> may only be accessed by privileged software. Processor 
initialization sets the PSL to 041F 0000 i6- Figure 5-2 shows the 
processor status longword bit map. 



31 30 29 28 27 26 25 24 23 22 21 20 



Diagnostic Processor 5—3 



876543210 



CM 

TP 

MBZ 

FPD ■ 

IS 

CUR MOD 

PRV MOD ■ 

MBZ 



IPL 



DV- 
FU- 
IV - 



Figure 5-2 PSL Bit Map 



T N Z V C 



MA-X0657-89 



Data Bit 



Definition 



PSL <31> (CM) Compatibility mode. This bit always reads as zero; 
loading a 1 into this bit has no effect. 

PSL <30> (TP) Trace pending 

PSL <29:28> Unused, must be written as zero. 

PSL <27> (FPD) First part done 

PSL <26> (IS) Interrupt stack 

PSL <25:24> (CUR) Current mode 

PSL <23:22> (PRV) Previous mode 

PSL <21> Unused, must be written as zero. 

PSL <20:16> (IPL) Interrupt priority level 

PSL <15:8> Unused, must be written as zero. 



5—4 Diagnostic Processor 



Data Bit Definition 



PSL <7> (DV) Decimal overflow trap enable. This read/write bit has no 

effect on KN210 hardware; it can be used by macrocode which 
emulates VAX decimal instructions. 

PSL <6> (FU) Floating underflow fault enable 

PSL <5> (IV) Integer overflow trap enable 

PSL <4> (T) Trace trap enable 

PSL <3> (N) Negative condition code 

PSL <2> (Z) Zero condition code 

PSL <1> (V) Overflow condition code 

PSL <0> (C) Carry condition code 

5.1.1.3 Internal Processor Registers 

The KN210 IPRs can be accessed by using the MFPR and MTPR 
privileged instructions. Each IPR falls into one of the following seven 
categories: 

1. Implemented by KN210 (in the CVAX chip) 

2. Implemented by KN210 (in the SSC) 

3. Implemented by KN210 (and all designs that use the CVAX chip) 
uniquely 

4. Implemented by KN210 (and all designs that use the SSC) uniquely 

5. Not implemented, timed out by the CDAL bus timer (in the SSC) after 
4 us. Read as zero, NOP on write. 

6. Access not allowed; accesses result in a reserved operand fault 

7. Accessible, but not fully implemented; accesses yield unpredictable 
results 

Refer to Table 5-1 for a listing of each of the KN210 IPRs, along with its 
mnemonic, its access type (read or write) and its category number. 



Diagnostic Processor 5—5 



Table 5-1 KN210 Internal Processor Registers 



Decimal Hex 


Register Name 


Mnemonic 


Type 


Category 1 








Kernel stack pointer 


KSP 


R/W 


1 


1 


1 


Executive stack pointer 


ESP 


R/W 


1 


2 


2 


Supervisor stack pointer 


SSP 


R/W 


1 


3 


3 


User stack pointer 


USP 


R/W 


1 


4 


4 


Interrupt stack pointer 


ISP 


R/W 


1 


7:5 


7:5 


Reserved 






5 


8 


8 


P0 base register 


POBR 


R/W 


1 


9 


9 


P0 length register 


POLR 


R/W 


1 


10 


A 


PI base register 


P1BR 


R/W 


1 


11 


B 


PI length register 


P1LR 


R/W 


1 


12 


C 


System base register 


SBR 


R/W 


1 


13 


D 


System length register 


SLR 


R/W 


1 


15:14 


F:E 


Reserved 






5 


16 


10 


Process control block 
base 


PCBB 


R/W 


1 


17 


11 


System control block 
base 


SCBB 


R/W 


1 


18 


12 


Interrupt priority level 


IPL 


R/W 


11 


19 


13 


AST level 


ASTLVL 


R/W 


11 


20 


14 


Software interrupt 
request 


SIRR 


W 


1 


21 


15 


Software interrupt 
summary 


SISR 


R/W 


11 


23:22 


17:16 


Reserved 






5 


24 


18 


Interval clock 
control/status 


ICCS 


R/W 


31 


25 


19 


Next interval count 


NICR 


W 


5 


26 


1A 


Interval count 


ICR 


R 


5 


27 


IB 


Time-of-year 


TODR 


R/W 


2 


28 


1C 


Console storage receiver 
status 


CSRS 


R/W 


71 


29 


ID 


Console storage receiver 
data 


CSRD 


R 


71 


30 


IE 


Console storage transmit 
status 


CSTS 


R/W 


71 



1 An I following the category number indicates that the register is initialized on power-up 
and by the negation of DCOK when the processor is halted. 



5-6 Diagnostic Processor 



Table 5-1 (Cont.) KN210 Internal Processor Registers 



Decimal Hex 


Register Name 


Mnemonic 


Type 


Category 1 


31 


IF 


Console storage transmit 
data 


CSTD 


W 


71 


32 


20 


Console receiver 
control/status 


RXCS 


R/W 


41 


33 


21 


Console receiver data 
buffer 


RXDB 


R 


41 


34 


22 


Console transmit 
control/status 


TXCS 


R/W 


41 


35 


23 


Console transmit data 
buffer 


TXDB 


W 


41 


36 


24 


Translation buffer 
disable 


TBDR 


R/W 


5 


37 


25 


Cache disable 


CADR 


R/W 


31 


38 


26 


Machine check error 
summary 


MCESR 


R/W 


5 


39 


27 


Memory system error 


MSER 


R/W 


31 


41:40 


29:28 


Reserved 






5 


42 


2A 


Console saved PC 


SAVPC 


R 


3 


43 


2B 


Console saved PSL 


SAVPSL 


R 


3 


47:44 


2F:2C 


Reserved 






5 


48 


30 


SBI fault/status 


SBIFS 


R/W 


5 


49 


31 


SBI silo 


SBIS 


R 


5 


50 


32 


SBI silo comparator 


SBISC 


R/W 


5 


51 


33 


SBI maintenance 


SBIMT 


R/W 


5 


52 


34 


SBI error register 


SBIER 


WW 


5 


53 


35 


SBI timeout address 
register 


SBITA 


R 


5 


54 


36 


SBI quadword clear 


SBIQC 


W 


5 


55 


37 


I/O bus reset 


IORESET 


W 


4 


56 


38 


Memory management 
enable 


MAPEN 


R/W 


1 


57 


39 


TB invalidate all 


TBIA 


W 


1 


58 


3A 


TB invalidate single 


TBIS 


W 


1 


59 


3B 


TBdata 


TBDATA 


R/W 


5 


60 


3C 


Microprogram break 


MBRK 


WW 


5 



1 An I following the category number indicates that the register is initialized on power-up 
and by the negation of DCOK when the processor is halted. 



Diagnostic Processor 5-7 



Table 5-1 (Cont.) KN21 Internal Processor Registers 



Decimal Hex Register Name 



Mnemonic iyp e Category 1 



61 


3D 


Performance monitor 
enable 


PMR 


R/W 


5 


62 


3E 


System identification 


SID 


R 


1 


63 


3F 


Translation buffer check 


TBCHK 


W 


1 


64:127 


40:7F 


Reserved 






6 



1 An I following the category number indicates that the register is initialized on power-up 
and by the negation of DCOK when the processor is halted. 



KN210 Diagnostic VAX Standard IPRs 

VAX standard internal processor registers (IPRs) are classified as 
Category One IPRs. The VAX Architecture Reference Manual should 
be consulted for details on the operation and use of these registers. 

The VAX standard IPRs listed in Table 5—2 are also referenced in other 
sections of this manual. 



Table 5-2 VAX Standard IPRs 



Number Register Name 



Mnemonic Section 



12 System base register 

13 System length register 

16 Process control block base 

17 System control block base 

18 Interrupt priority level 

20 Software interrupt request 

21 Software interrupt summary 
27 Time-of-year clock 

56 Memory management enable 

57 Translation buffer invalidate 
all 

58 Translation buffer invalidate 
single 

62 System identification 

63 Translation buffer check 



SBR 


5.1.5.3 


SLR 


5.1.5.3 


PCBB 


5.1.5 


SCBB 


5.1.5.4 


IPL 


5.1.5.1 


SIRR 


5.1.5.1 


SISR 


5.1.5.1 


TODR 


3.6.2 


MAPEN 


5.1.4.2 


TBIA 


5.1.4.2 



TBIS 

SD3 
TBCHK 



5.1.4.2 

5.1.6 
5.1.4.2 



5—8 Diagnostic Processor 



KN210 Unique IPRs 

Internal processor registers that are implemented uniquely on the KN210 
are described in detail in this manual. Refer to the sections listed in 
Table 5-3 for a description of these registers. 

Table 5-3 KN210 Unique IPRs 

Number Register Name Mnemonic Section 



24 


Interval clock control/status 


ICCS 


3.6.3 


32 


Console receiver 
control/status 


RXCS 


3.5.1.1 


33 


Console receiver data buffer 


RXDB 


3.5.1.2 


34 


Console transmit 
control/status 


TXCS 


3.5.1.3 


35 


Console transmit data buffer 


TXDB 


3.5.1.4 


42 


Console saved PC 


SAVPC 


5.1.5 


43 


Console saved PSL 


SAVPSL 


5.1.5 



5.1.2 Data Types 

The diagnostic processor supports the following subset of the "VAX data 
types: 

Byte 

Word (16-bit) 

Longword (32-bit) 

Quadword (64-bit) 

Character string 

Variable length bit field 

5.1.3 Instruction Set 

The KN210 CPU implements the following subset of the "VAX instruction 
set types in microcode: 

• Integer arithmetic and logical 

• Address 

• Variable length bit field 



Diagnostic Processor 5—9 

Control 

Procedure call 

Miscellaneous 

Queue 1 

Character string moves (MOVC3, MOVC5, CMPC3 1 , CMPC5 1 , 
LOCC 1 , SCANC 1 , SKPC 1 , and SPANC 1 ) 

Operating system support 

5.1 .4 Memory Management 

The KN210 implements full VAX memory management. System space 
addresses are virtually mapped through single-level page tables, and 
process space addresses are virtually mapped through two-level page 
tables. 

5.1.4.1 Translation Buffer 

To reduce the overhead associated with translating virtual addresses 
to physical addresses, the KN210 employs a 28-entry, fully associative, 
translation buffer for caching VAX PTEs in modified form. Each entry 
can store a modified PTE for translating virtual addresses in either the 
VAX process space, or VAX system space. The translation buffer is flushed 
whenever memory management is enabled or disabled (that is, by writes 
to IPR 56), any page table base or length registers are modified (that 
is, by writes to IPRs 8 - 13) and by writing to IPR 57 (TBIA) or IPR 58 
(TBIS). 

Each entry is divided into two parts: a 23-bit tag register and a 31-bit 
PTE register. The tag register is used to store the virtual page number 
(VPN) of the virtual page that the corresponding PTE register maps. The 
PTE register stores the 21-bit PFN field, the PTE.V bit, the PTE.M bit 
and an 8-bit partially decoded representation of the 4-bit VAX PTE PROT 
field, from the corresponding VAX PTE, as well as a translation buffer 
valid (TB.V) bit. 

During virtual to physical address translation, the contents of the 28 tag 
registers are compared with the virtual page number field (bits <31:9>) of 
the virtual address of the reference. If there is a match with one of the 
tag registers, then a translation buffer hit occurs, and the contents of the 
corresponding PTE register is used for the translation. 



1 These instructions were in the microcode assisted category on the KA630-AA 
(MicroVAX II) and therefore had to be emulated. 



5—1 Diagnostic Processor 



If there is no match, the translation buffer does not contain the necessary 
VAX PTE information to translate the address of the reference, and 
the PTE must be fetched from memory. Upon fetching the PTE, the 
translation buffer is updated by replacing the entry that is selected 
by the replacement pointer. Since this pointer is moved to the next 
sequential translation buffer entry whenever it is pointing to an entry 
that is accessed, the replacement algorithm is not last used (NLU). 

5.1.4.2 Memory Management Control Registers 

There are four IPRs that control the memory management unit (MMU): 
IPR 56 (MAPEN), IPR 57 (TBIA), IPR 58 (TBIS), and IPR 63 (TBCHK). 

Memory management can be enabled/disabled through IPR 56 (MAPEN). 
Writing a to this register with a MTPR instruction disables memory 
management, and writing a 1 to this register with a MTPR instruction 
enables memory management. Writes to this register flush the translation 
buffer. To determine whether or not memory management is enabled, IPR 
56 is read using the MFPR instruction. Translation buffer entries that 
map a particular virtual address can be invalidated by writing the virtual 
address to IPR 58 (TBIS) using the MTPR instruction. 

NOTE 

Whenever software changes a valid PTE for the system or current 
process region, or a system PTE that maps any part of the current 
process page table, all process pages mapped by the PTE must be 
invalidated in the translation buffer. 

The entire translation buffer can be invalidated by writing a to IPR 57 
(TBIA) using the MTPR instruction. 

The translation buffer can be checked to see if it contains a valid 
translation for a particular virtual page by writing a virtual address 
within that page to IPR 63 (TBCHK) using the MTPR instruction. If the 
translation buffer contains a valid translation for the page, the condition 
code V bit (bit <1> of the PSL) is set. 

NOTE 

The TBIS, TBIA, and TBCHK IPRs are write only. The operation 

of a MFPR instruction from any of these registers is undefined. 



Diagnostic Processor 5-11 



5.1.5 Exceptions and Interrupts 

Both exceptions and interrupts divert execution from the normal flow of 
control. An exception is caused by the execution of the current instruction 
and is typically handled by the current process (for example, an arithmetic 
overflow), while an interrupt is caused by some activity outside the 
current process and typically transfers control outside the process (for 
example, an interrupt from an external hardware device). 

5.1.5.1 Interrupts 

Interrupts can be divided into two classes: non-maskable, and maskable. 

Non-maskable interrupts cause a halt through the hardware halt 
procedure which saves the PC, PSL, MAPEN<0> and a halt code in IPRs, 
raises the processor IPL to IF and then passes control to the resident 
firmware. The firmware dispatches the interrupt to the appropriate 
service routine based on the halt code and hardware event indicators. 

Non-maskable interrupts cannot be blocked by raising the processor IPL, 
but can be blocked by running out of the halt protected address space 
(except those non-maskable interrupts that generate a halt code of 3). 
Non-maskable interrupts with a halt code of 3 cannot be blocked since 
this halt code is generated after a hardware reset. 

Maskable interrupts cause the PC and PSL to be saved, the processor 
IPL to be raised to the priority level of the interrupt (except for Q22-bus 
interrupts where the processor IPL is set to 17 independent of the level at 
which the interrupt was received) and the interrupt to be dispatched to 
the appropriate service routine through the system control block (SCB). 

The various interrupt conditions for the KN210 are listed in Table 5—4 
along with their associated priority levels and SCB offsets. 

Table 5-4 Interrupts 

Priority 

Level Interrupt Condition SCB Offset 

Non- BDCOK and BPOK negated then * 

maskable asserted on Q22-bus (Power up) 

BDCOK negated then asserted 

while BPOK asserted on Q22-bus 

(SCR<7> clear) 

lr Fhese conditions generate a hardware halt procedure with a halt code of 3 (hardware 
reset). 



5-1 2 Diagnostic Processor 



Table 5-4 (Cont.) Interrupts 



Priority 




Level Interrupt Condition 


SCB Offset 


BDCOK negated then asserted 


2 


while BPOK asserted on Q22-bus 




(SCR<7> set) 




BHALT asserted on Q22-bus 


2 


BREAK generated by the console 


2 


device 




IF Unused 




IE BPOK negated on Q22-bus 


oc 


ID CDAL bus parity error 


60 


Q22-bus NXM on a write 


60 


CDAL bus timeout during DMA 


60 


Main memory NXM errors 


60 


Uncorrectable main memory errors 


60 


1C - IB Unused 




LA Correctable main memory errors 


54 


19 - 18 Unused 




17 BR7 L asserted 


Q22-bus vector plus 200 16 


16 Interval timer interrupt 


CO 


Mass storage interface 


C5 


Network interface 


D5 


BR6 L asserted 


Q22-bus vector plus 200 i 6 


15 BR5 L asserted 


Q22-bus vector plus 200 i 6 


14 Console terminal 


F8,F6 i6 


Programmable timers 


78,7C 


BR4 L asserted 


Q22-bus vector plus 200 i 6 


13 - 10 Unused 




OF - 01 Software interrupt requests 


84-BC 


2 These conditions generate a hardware halt procedure with 


a halt code of 2 (external halt). 



NOTE 

Because the Q22-bus does not allow differentiation between the 
four bus grant levels (that is, a level 7 device could respond to a 
level 4 bus grant), the KN210 diagnostic processor raises the DPL 
to 17 after responding to interrupts generated by the assertion of 
either BR7 L, BR6 L, BR5 L, or BR4 L. The KN210 maintains the 
EPL at the priority of the interrupt for all other interrupts. 



Diagnostic Processor 5—1 3 



The interrupt system is controlled by three IPRs: IPR 18, the interrupt 
priority level register (IPL), IPR 20, the software interrupt request 
register (SIRR), and IPR 21, the software interrupt summary register 
(SISR). 

The IPL is used for loading the processor priority field in the PSL (bits 
<20:16>). The SIRR is used for creating software interrupt requests. The 
SISR records pending software interrupt requests at levels 1 through 15. 
The format of these registers is shown in Figure 5—3. 



IGNORED .RETURNS ZERO 



PSL<20:15> 



31 






4 


3 





IGNORED 








REQUEST 







31 16 15 



PENDING SOFTWARE INTERRUPTS 
FEDCBA987654321 



SISR 



MBZ - 

MA-X06&8-80 



Figure 5-3 Interrupt Registers 

5.1.5.2 Exceptions 

Exceptions can be divided into three types: 

• Trap 

• Fault 

• Abort 

A trap is an exception that occurs at the end of the instruction that caused 
the exception. After an instruction traps, the PC saved on the stack is the 
address of the next instruction that would have normally been executed 
and the instruction can be restarted. 



5—1 4 Diagnostic Processor 



A fault is an exception that occurs during an instruction, and that leaves 
the registers and memory in a consistent state such that the elimination 
of the fault condition and restarting the instruction will give correct 
results. After an instruction faults, the PC saved on the stack points to 
the instruction that faulted. 

An abort is an exception that occurs during an instruction, leaving the 
value of the registers and memory unpredictable, such that the instruction 
cannot necessarily be correctly restarted, completed, simulated or undone. 
After an instruction aborts, the PC saved on the stack points to the 
instruction that was aborted (which may or may not be the instruction 
that caused the abort) and the instruction may or may not be restarted 
depending on the class of the exception and the contents of the parameters 
that were saved. 

Exceptions are grouped into six classes: 

Arithmetic 

Memory management 

Operand reference 

Instruction execution 

Tracing 

System failure 

A list of exceptions grouped by class is given in Table 5—5. Exceptions 
save the PC and PSL and in some cases, one or more parameters, on the 
stack. Most exceptions do not change the IPL of the processor (except 
the exceptions in serious system failures class, which set the processor 
IPL to IF) and cause the exception to be dispatched to the appropriate 
service routine through the SCB (except for the interrupt stack not 
valid exception, and exceptions that occur while an interrupt or another 
exception are being serviced, which cause the exception to be dispatched 
to the appropriate service routine by the resident firmware). 

The exceptions listed in Table 5—5 (except machine check) are described 
in greater detail in the VAX Architecture Reference Manual. The 
machine check exception is described in greater detail in Section 5.1.5.3. 
Exceptions that can occur while servicing an interrupt or another 
exception are listed in Table 5-8 in Section 5.1.5.6. 



Diagnostic Processor 5—15 



Table 5-5 Exceptions 



Arithmetic Exceptions 



Type 



SCB Offset 



Integer overflow 
Integer divide-by-zero 
Subscript range 



Trap 


34 


Trap 


34 


Trap 


34 



Memory Management 
Exceptions 


Type 


SCB Offset 


Access control violation 
Translation not valid 


Fault 
Fault 


20 
24 


Operand Reference Exceptions 


Type 


SCB Offset 


Reserved addressing mode 
Reserved operand fault 


Fault 
Abort 


1C 

18 


Instruction Execution 
Exceptions 


Type 


SCB Offset 



Reserved/privileged instruction 


Fault 


10 


Emulated instruction 


Fault 


C8, CC 


Change mode 


Trap 


40-4C 


Breakpoint 


Fault 


2C 



Tracing Exception 


Type 


SCB Offset 


Trace 


Fault 


28 


System Failure Exceptions 


Type 


Offset 


Interrupt stack not valid 
Kernel stack not valid 


Abort 
Abort 


l 
08 



1 Dispatched by resident firmware rather than through the SCB 



5-1 6 Diagnostic Processor 



Table 5-5 (Cont.) Exceptions 



System Failure Exceptions 



Type 



Offset 



Machine check 

CDAL bus parity errors 
Cache parity errors 
Q22-bus NXM errors 
Q22-bus device parity errors 
Q22-bus NO GRANT errors 
CDAL bus timeout errors 
Main memory NXM errors 
Main memory uncorrectable 
errors 



Abort 



04 



5.1.5.3 Information Saved on a Machine Check Exception 

In response to a machine check exception the PSL, PC, four parameters, 
and a byte count are pushed onto the stack, as shown in Figure 5—4. 



BYTE COUNT 



:SP 



MACHINE CHECK CODE 



MOST RECENT VIRTUAL ADDRESS 



INTERNAL STATE INFORMATION 1 



INTERNAL STATE INFORMATION 2 



PC 



PSL 



Figure 5-4 Information Saved on a Machine Check Exception 

The meaning of this information and how it effects the recovery procedure 
is described in the following paragraphs. 



Byte Count 

<31:0> = 0000 0010 i6, 16 io- This value indicates the number of bytes of 
information that follow on the stack (not including the PC and PSL). 



Diagnostic Processor 5—17 



Machine Check Code Parameter 

Machine Check Code <31:0>— A code value that indicates the type of 
machine check that occurred. A list of the possible machine check codes 
(in hex) and their associated causes follows. 

Memory Management Errors — These codes indicate that the microcode in 
the CVAX CPU chip detected an impossible situation while performing 
functions associated with memory management. The most likely cause 
of this type of a machine check is a problem internal to the CVAX 
chip. Machine checks due to memory management errors are non- 
recoverable. Depending on the current mode, either the current process 
or the operating system should be terminated. The state of the POBR, 
POLR, P1BR, P1LR, SBR, and SLR should be logged. 

Hex 

Code Error Description 

5 The calculated virtual address for a process PTE was in the PO space 
instead of the system space when the CPU attempted to access a process 
PTE after a translation buffer miss. 

6 The calculated virtual address space for a process PTE was in the PI 
space instead of the system space when the CPU attempted to access a 
process PTE after a translation buffer miss. 

7 The calculated virtual address for a process PTE was in the PO space 
instead of the system space when the CPU attempted to access a 
process PTE to change the PTE <M> bit before writing to a previously 
unmodified page. 

8 The calculated virtual address for a process PTE was in the PI space 
instead of the system space when the CPU attempted to access a 
process PTE to change the PTE <M> bit before writing to a previously 
unmodified page. 

Interrupt Errors — This code indicates that the interrupt controller in 
the diagnostic processor requested a hardware interrupt at an unused 
hardware IPL. The most likely cause of this type of a machine check is a 
problem internal to the CVAX chip. Machine checks due to unused IPL 
errors are non-recoverable. A non-vectored interrupt generated by a 
serious error condition (memory error, power fail, or processor halt) has 
probably been lost. The operating system should be terminated. 



5-1 8 Diagnostic Processor 



Hex 

Code Error Description 



9 A hardware interrupt was requested at an unused Interrupt Priority 

Level (IPL). 

Microcode Errors — This code indicates that an impossible situation 
was detected by the microcode during instruction execution. Note that 
most erroneous branches in the CVAX CPU microcode cause random 
microinstructions to be executed. The most likely cause of this type 
of machine check is a problem internal to the CVAX chip. Machine 
checks due to microcode errors are non-recoverable. Depending on 
the current mode, either the current process or the operating system 
should be terminated. 



Hex 

Code Error Description 

A An impossible state was detected during a MOVC3 or MOVC5 

instruction (not move forward, move backward, or fill). 

Read Errors — These codes indicate that an error was detected while the 
CVAX CPU was attempting to read from either the cache, main memory, 
or the Q22-bus. The most likely cause of this type of machine check 
must be determined from the state of the MSER, DSER, MEMCSR16, 
QBEAR, DEAR, and CBTCR. Machine checks due to read errors may be 
recoverable, depending on the state of the VAX CAN'T RESTART flag 
(captured in Internal State Information 2 <15>) and the FIRST PART 
DONE flag (captured in PSL <27>). If the FIRST PART DONE flag is 
set, the error is recoverable. If the FIRST PART DONE flag is cleared, 
then the VAX CAN'T RESTART flag must also be cleared for the error 
to be recoverable. Otherwise, the error is unrecoverable and depending 
on the current mode, either the current process or the operating system 
should be terminated. The information pushed onto the stack by this type 
of machine check is from the instruction that caused the machine check. 

Hex 

Code Error Description 

80 An error occurred while reading an operand, a process PTE during 

address translation, or on any read generated as part of an interlocked 
instruction. 



Diagnostic Processor 5-19 



Hex 

Code Error Description 



81 An error occurred while reading a system page table entry (SPTE), 
during address translation, a process control block (PCB) entry during a 
context switch, or a system control block (SCB) entry while processing 
an interrupt. 

Write Errors — These codes indicate that an error was detected while the 
CVAX CPU was attempting to write to either the cache, main memory, 
or the Q22-bus. The most likely cause of this type of machine check 
must be determined from the state of the MSER, DSER, MEMCSR16, 
QBEAR, DEAR, and CBTCR. Machine checks due to write errors are 
non-recoverable because the CPU is capable of performing many read 
operations out of the cache before a write operation completes. For this 
reason, the information that is pushed onto the stack by this type of 
machine check cannot be guaranteed to be from the instruction that 
caused the machine check. 

Hex 

Code Error Description 

82 An error occurred while writing an operand, or a process page table 
entry (PPTE) to change the PTE <M> bit before writing a previously 
unmodified page. 

83 An error occurred while writing a system page table entry (SPTE) to 
change the PTE <M> bit before writing a previously unmodified page, 
or a PCB entry during a context switch or during the execution of 
instructions that modify any stack pointers stored in the PCB. 

Most Recent Virtual Address Parameter 

Most Recent "Virtual Address <31:0>— This field captures the contents 
of the virtual address pointer register at the time of the machine check. 
If a machine check, other than a machine check 81, occurs on a read 
operation, this field represents the virtual address of the location that is 
being read when the error occurred, plus four. If machine check 81 occurs, 
this field represents the physical address of the location that was being 
read when the error occurred, plus four. 



5-20 Diagnostic Processor 



If a machine check, other than a machine check 83, occurs on a write 
operation, this field represents the virtual address of a location that 
is being referenced either when the error occurred, or sometime after 
the error occurred, plus four. If a machine check 83 occurs, this field 
represents the physical address of the location that was being referenced 
either when the error occurred, or sometime after the error occurred, plus 
four. In other words, if the machine check occurs on a write operation, the 
contents of this field cannot be used for error recovery. 

Internal State Information 1 Parameter 

Internal State Information 1 is divided into four fields. The contents of 
these fields is described as follows: 

<31:24> — This field captures the opcode of the instruction that was being 
read or executed at the time of the machine check. 

<23:16> — This field captures the internal state of the CVAX CPU chip at 
the time of the machine check. The four most significant bits are equal to 
<1110> and the four least significant bits contain highest priority software 
interrupt <3:0>. 

<15:8> — This field captures the state of CADR <7:0> at the time of the 
machine check. 

<7:0> — This field captures the state of the MSER <7:0> at the time of the 
machine check. 

Internal State Information 2 Parameter 

Internal State Information 2 is divided into five fields. The contents of 
these fields is described as follows: 

<31:24>— This field captures the internal state of the CVAX CPU chip at 
the time of the machine check. This field contains SC register <7:0>. 

<23:16>— This field captures the internal state of the CVAX CPU chip at 
the time of the machine check. The two most significant bits are equal to 
11 (binary) and the six least significant bits contain state flags <5:0>. 

<15:^-This field captures the state of the VAX CANT RESTART flag at 
the time of the machine check. 



Diagnostic Processor 5—21 



<14:8> — This field captures the internal state of the CVAX CPU chip at 
the time of the machine check. The three most significant bits are equal 
to <111> (binary) and the four least significant bits contain ALU condition 
codes. 

<7:0>— This field captures the offset between the virtual address of the 
start of the instruction being executed at the time of the machine check 
(saved PC) and the virtual address of the location being accessed (PC) at 
the time of the machine check. 

PC 

PC <31:0>— This field captures the virtual address of the start of the 
instruction being executed at the time of the machine check. 

PSL 

PSL <31:0> — This field captures the contents of the PSL at the time of 
the machine check. 

5.1.5.4 System Control Block 

The system control block (SCB) consists of two pages in main memory that 
contain the vectors by which interrupts and exceptions are dispatched to 
the appropriate service routines. The SCB is pointed to by IPR 17, the 
system control block base register (SCBB), represented in Figure 5-5. 
The SCB format is presented in Table 5—6. 



PHYSICAL LONGWORD ADDRESS OF PCB 



UA-X0668-86 



Figure 5-5 System Control Block Base Register 



5-22 Diagnostic Processor 



Table 5-6 System Control Block Format 



SCB 



Offset Interrupt/Exception Type 



Parameter Notes 



00 


Unused 






IRQ passive release on 
other VAXes 


04 


Machine check 


Abort 


4 


Parameters depend on 
error type 


08 


Kernel stack not 
valid 


Abort 





Must be serviced on 
interrupt stack 


OC 


Power fail 


Interrupt 





IPL is raised to IE 


10 


Reserved/privileged 
instruction 


Fault 







14 


Customer reserved 
instruction 


Fault 





XFC instruction 


18 


Reserved operand 


Fault/Abort 


Not always recoverable 


1C 


Reserved 
addressing mode 


Fault 







20 


Access control 
violation 


Fault 


2 


Parameters are virtual 
address, status code 


24 


Translation not 
valid 


Fault 


2 


Parameters are virtual 
address, status code 


28 


Trace pending (TP) 


Fault 







2C 


Breakpoint 
instruction 


Fault 







30 


Unused 






Compatibility mode in 
other VAXes 


34 


Arithmetic 


Trap/Fault 


1 


Parameter is type code 


38:3C 


Unused 








40 


CHMK 


Trap 


1 


Parameter is sign- 
extended operand 
word 


44 


CHME 


Trap 


1 


Parameter is sign- 
extended operand 
word 


48 


CHMS 


Trap 


1 


Parameter is sign- 
extended operand 
word 



Diagnostic Processor 5—23 



Table 5-6 (Cont.) System Control Block Format 

SCB 



Offset Interrupt/Exception Type 



Parameter Notes 



4C 



CC 



CHMU 



Trap 



50 


Unused 






54 


Corrected read data 


Interrupt 





58:5C 


Unused 






60 


Memory error 


Interrupt 





64:6C 


Unused 






78 


Programmable 
timer 


Interrupt 





7C 


Programmable 
timer 1 


Interrupt 





80 


Unused 






84 


Software level 1 


Interrupt 





88 


Software level 2 


Interrupt 





8C 


Software level 3 


Interrupt 





90:BC 


Software levels 4-15 


Interrupt 





CO 


Interval timer 


Interrupt 





C4 


Mass storage 
interface 


Interrupt 





C8 


Emulation start 


Fault 


11 



Emulation continue Fault 



DO 


Unused 






D4 


Network interface 


Interrupt 





D8:DC 


Unused 






E0:EC 


Reserved for 
customer or CSS 
use 







Parameter is sign- 
extended operand 
word 

IPL is 1A (CRD L) 

IPL is ID 
(MEMERR L) 

IPL is 14 
IPL is 14 



Ordinarily used for 
AST delivery 
Ordinarily used for 
process scheduling 

IPL is 16 (INTTIM L) 
IPL is 14 

Same mode exception, 
FPD=0; parameters are 
opcode, PC, specifiers 
Same mode exception, 
FPD=1: no parameters 

IPL is 14 



5—24 Diagnostic Processor 



Table 5-6 (Cont.) System Control Block Format 



SCB 








Offset Interrupt/Exception 


Type 


Parameter Notes 


F0:F4 Unused 






Console storage 
registers on 11/750 
and 11/730 


F8 Console receiver 


Interrupt 





IPL is 14 


FC Console transmitter 


Interrupt 





IPL is 14 


100:1FC Adapter vectors 


Interrupt 





Not implemented by 
the KN210 


200:3FC Device vectors 


Interrupt 





Correspond to Q22- 
bus Vectors 000:1FC; 
KN210 appends the 
assertion of bit <9,0> 


400:FFC Unused 


Interrupt 








5.1.5.5 Diagnostic Processor Hardware Detected Errors 

The diagnostic processor is capable of detecting 11 types of error 
conditions during program execution. 

1. CDAL bus parity errors indicated by MSER <6> (on a read) or 
MEMCSR16 <7> (on a write) being set. 

2. Cache tag parity errors indicated by MSER <0> being set. 

3. Cache data parity errors indicated by MSER <1> being set. 

4. Q22-bus NXM errors indicated by DSER <7> being set. 

5. Q22-bus NO SACK errors (no indicator). 

6. Q22-bus NO GRANT errors indicated by DSER <2> being set. 

7. Q22-bus device parity errors indicated by DSER <5> being set. 

8. CDAL bus timeout errors indicated by DSER <4> (only on DMA) 
being set. 

9. Main memory NXM errors indicated by DSER <0> (only on DMA) 
being set. 

10. Main memory correctable errors indicated by MEMCSR16 <29> being 
set. 



Diagnostic Processor 5-25 



11. Main memory uncorrectable errors indicated by MEMCSR16 <31> 
and DSER <4> (only on DMA) being set. 

These errors will cause either a machine check exception, a memory error 
interrupt, or a corrected read data interrupt, depending on the severity of 
the error and the reference type that caused the error. 

5.1.5.6 Hardware Halt Procedure 

The hardware halt procedure is the mechanism by which the hardware 
assists the firmware in emulating a processor halt. The hardware halt 
procedure saves the current value of the PC in IPR 42 (SAVPC), and 
the current value of the PSL, MAPEN<0>, and a halt code in IPR 43 
(SAVPSL). The current stack pointer is saved in the appropriate internal 
register. The PSL is set to 041F 0000 16 (IPL=1F, kernel mode, using the 
interrupt stack) and the current stack pointer is loaded from the interrupt 
stack pointer. Control is then passed to the resident firmware at physical 
address 2004 0000 16 with the state of the CPU as follows: 

Register New Contents 

SAVPC Saved PC 

SAVPSL<31:16, 7:0> Saved PSL<31:16,7:0> 

SAVPSL <15> Saved MAPEN<0> 

SAVPSL <14> Valid PSL flag (unknown for halt code of 3) 

SAVPSL <13:8> Saved restart code 

SP Current interrupt stack 

PSL 041F 0000 i 6 

PC 2004 0000 16 

MAPEN 

ICCS (for a halt code of 3) 

MSER (for a halt code of 3) 

CADR (for a halt code of 3, cache is also flushed) 

SISR (for a halt code of 3) 

ASTLVL (for a halt code of 3) 

All else Undefined 

The firmware uses the halt code in combination with any hardware event 
indicators to dispatch the execution or interrupt that caused the halt to 
the appropriate firmware routine (either console emulation, power-up, 
reboot, or restart). Tables 5-7 and 5-8 list the interrupts and exceptions 
that can cause halts along with their corresponding halt codes and event 
indicators. 



5-26 Diagnostic Processor 



Table 5-7 Unmaskable Interrupts That can Cause a Halt 



Halt 
Code 



Interrupt Condition 



Event Indicators 



External Halt (CVAX HALTBSf 
pin asserted) 

BHALT asserted on the Q22-bus. 
BDCOK negated and asserted on the 
Q22-bus while BPOK stays asserted 
(Q22-bus REBOOT/RESTART) and 
SCR <7> is set. 
BREAK generated by the console 



DSER<15> 
DSER <14> 



RXDB <11> 



Hardware Reset (CVAX RESET 
pin negated) 

BDCOK and BPOK negated then 
asserted on the Q22-bus (Power-up) 
BDCOK negated and asserted on the 
Q22-bus while BPOK stays asserted 
(Q22-bus REBOOT/RESTART) and 
SCR <7> is clear. 



Table 5-8 Exceptions That can Cause a Halt 



Halt 
Code 



Exception Condition 



HALT instruction executed in kernel mode 



Exceptions While Servicing an Interrupt or Exception 



4 

5 

7 

8 

A 

B 

10 

11 

12 



Interrupt stack not valid during exception 

Machine check during normal exception 

SCB vector bits <1:0> = 11 

SCB vector bits <1:0> = 10 

CHMx executed while on interrupt stack 

CHMx executed to the interrupt stack 

ACV or TNV during machine check exception 

ACV or TNV during kernel stack not valid exception 

Machine check during machine check exception 



Diagnostic Processor 5—27 



Table 5-8 (Cont.) Exceptions That can Cause a Halt 



Halt 
Code 



Exception Condition 



13 Machine check during kernel stack not valid exception 

19 PSL <26:24> = 101 during interrupt or exception 

1A PSL <26:24> = 110 during interrupt or exception 

IB PSL <26:24> = 111 during interrupt or exception 

ID PSL <26:24> = 101 during REI 

IE PSL <26:24> = 110 during REI 

IF PSL <26:24> = 111 during REI 



5.1 .6 System Identification 

The system identification register (SID), IPR 62, is a read-only register 
implemented in the CVAX chip. This 32-bit, read-only register is used to 
identify the processor type and its microcode revision level (Figure 5-6). 



2423 



TYPE 


RESERVED 


MICROCODE REV. 



MA-1101-87 



Figure 5-6 System Identification Register 



Field Name 



RW Description 



31:24 



15:8 



7:0 



SYS_ 
TYPE 



23:16 VERSION ro 



SYS_ 
SUB_ 
TYPE 



This field identifies the type of system for a specific 
processor. (Reads as 06 for the KN210.) 

This field identifies the resident version of the 
firmware EPROM encoded as two hexadecimal 
digits. For example, if the banner displays V5.0, 
then this field is 50 (hex). 

This field identifies the particular system sub-type. 
(Reads as 01 for the KN210.) 



HARDWARE ro This field identifies the hardware revision level. 



5—28 Diagnostic Processor 



In order to distinguish between different CPU implementations that use 
the same CPU chip, the KN210 implements a MicroVAX system type 
register (SYSJTYPE) at physical address 2004 0004 16 . This 32-bit read- 
only register is implemented in the KN210 ROM. The format of this 
register is shown in Figure 5—7. 



SYS_TYPE 


VERSION 


SYS_SUB_TYPE 


RESERVED 



MA-XO661-80 



Figure 5-7 System Type Register 



Data Bit 



Definition 



SYSJTYPE 
<31:24> 

SYSJTYPE 
<23:16> 

SYSJTYPE 
<15:8> 



(SYSJTYPE) System type code. This field reads as 01 ie for 
all single-processor Q22-bus based systems. 

(REV LEVEL) Revision level. This field reflects the revision 
level of the KN210 firmware. 

(SYS_SUB_TYPE) System sub-type code. This field reads as 
10 i 6 for the KN210. 



SYSJTYPE <7:0> Reserved for Digital use. 



5.1 .7 CYAX References 

All references by the CPU can be classified into one of three groups: 

• Request instruction-stream read references 

• Demand data-stream read references 

• Write references 

5.1.7.1 Instruction-Stream Read References 

The diagnostic processor has an instruction prefetcher with a 12-byte 
(3 longword) instruction prefetch queue (IPQ) for prefetching program 
instructions from either cache or main memory. Whenever there is an 
empty longword in the IPQ, and the prefetcher is not halted due to an 
error, the instruction prefetcher generates an aligned longword, request 
instruction-stream (I-stream) read reference. 



Diagnostic Processor 5—29 

5.1.7.2 Data-Stream Read References 

Whenever data is immediately needed by the CPU to continue processing, 
a demand data-stream (D-stream) read reference is generated. More 
specifically, demand D-stream references are generated on operand, PTE, 
SCB, and PCB references. 

When interlocked instructions, such as branch on bit set and set 
interlock (BBSSI) are executed, a demand D-stream read-lock reference 
is generated. Since the CPU does not impose any restrictions on data 
alignment (other than the aligned operands of the add aligned word 
interlocked (ADAWI) and interlocked queue instructions) and since 
memory can only be accessed one aligned longword at a time, all data 
read references are translated into an appropriate combination of masked 
and unmasked, aligned longword read references. 

If the required data is a byte, a word within a longword, or an aligned 
longword, then a single, aligned longword, demand D-stream read 
reference is generated. If the required data is a word that crosses a 
longword boundary, or an unaligned longword, then two successive aligned 
longword demand D-stream read references are generated. Data larger 
than a longword is divided into a number of successive aligned longword 
demand D-stream reads, with no optimization. 

5.1.7.3 Write References 

Whenever data is stored or moved, a write reference is generated. Since 
the CPU does not impose any restrictions on data alignment (other than 
the aligned operands of the ADAWI and interlocked queue instructions) 
and since memory can only be accessed one aligned longword at a time, 
all data write references are translated into an appropriate combination 
of masked and unmasked aligned longword write references. 

If the required data is a byte, a word within a longword, or an aligned 
longword, then a single, aligned longword, write reference is generated. 
If the required data is a word that crosses a longword boundary, or 
an unaligned longword, then two successive aligned longword write 
references are generated. Data larger than a longword is divided into 
a number of successive aligned longword writes. 



6 



Maintenance Mode Firmware 



This chapter describes the KN210 maintenance mode functional firmware. 
The maintenance mode firmware is "VAX-11 code which resides in EPROM 
on the KN210 processor module. The maintenance mode firmware gains 
control by one of the following methods: 

• On the execution of the maintenance command from the KN210 
operational (R3000) console 

• On system power-up 

• When the onboard CVAX CPU performs a processor restart operation 

A processor restart operation is also called a processor halt. Halt, in this 
context, means only that the control is transferred to the firmware. It 
does not mean that the processor actually stops executing instructions. 

6.1 Maintenance Mode Firmware Features 

The maintenance mode firmware is located on one 128 Kbyte EPROM on 
the KN210 processor module, and provides the following features: 

• Diagnostic tests that test all components on the board and verify that 
the module is working correctly 

• Manual bootstrap of an operating system following processor halts 

• Manual restart of an operating system following processor halts 
(Restart in this context is not the same as restarting or resetting the 
hardware.) 

• An interactive command language that allows the user to examine 
and alter the state of the processor 

• Multilanguage support for displaying critical system messages and 
handling LK201 country specific keyboards 

6-1 



6—2 Maintenance Mode Firmware 



6.1.1 Halt Entry, Exit, and Dispatch 

The main purpose of this code is to save the state of the machine on halt 
entry, invoke the dispatcher, and restore the state of the machine on exit 
to program I/O mode. 

6.1.1.1 Halt Entry - Saving Processor State 

The entry code (residing at physical address 2004 0000) is executed 
whenever a halt occurs. The processor will halt for a variety of reasons. 
The reason for the halt is stored in PR$_SAVPSL<13:8>(RESTART_ 
CODE), IPR 43. A complete list of the halt reasons and the associated 
messages can be found in Table 6-10 in Section 6.8. PR$_SAVPC, IPR 
42, contains the value of the PC when the processor was halted. On a 
power-up, PR$_SAVPC is undefined. 

One of the first actions the firmware does after a halt is save the current 
LED code, then it writes an "E" to the diagnostic LEDs. This action occurs 
within several instructions upon entry into the firmware. The intent of 
this action is to let the user know that at least some instructions have 
been successfully executed. 

The maintenance mode firmware unconditionally saves the following 
egisters on any halt: 

R0 through R15, the general purpose registers 

PR$_SAVPSL, the saved PSL register 

PR$_SCBB, the system control block base register 

DLEDR, the diagnostic LED register 

SSCCR, the SSC configuration register 

ADxMCH & ADxMSK, the SSC address match and mask registers 

NOTE 

The SSC programmable timer registers are not saved. In some 
cases, such as bootstrap, the timers are used by the firmware and 
previous "time" context is lost. 

Several registers are unconditionally set to pre-determined values by the 
firmware on any halt, processor init or bootstrap. This action ensures that 
the firmware itself can run and protects the board from physical damage. 

Registers that fall into this category are: 

• SSCCR, the SSC configuration register 

• ADxMCH & ADxMSK, the SSC address match and mask registers 



Maintenance Mode Firmware 6—3 



• CBTCR, the CDAL bus timeout control register 

• TTVRx, the SSC timer interrupt vector registers 

On every halt entry, the firmware sets the console serial line baud rate 
based on the value read from the BDR and extends the halt protection 
from 8 Kbytes to 128 Kbytes to include all of the EPROM. 

6.1.1.2 Halt Exit - Restoring Processor State 

When the firmware exits, it uses the currently defined saved context. This 
context is initially determined by what is saved on entry to the firmware, 
and may be modified by console commands, or automatic operations such 
as an automatic bootstrap on power-up. 

When restoring the context, the firmware will flush both caches if enabled, 
and invalidate all translation buffer entries through the internal processor 
register PR$_TBIA, IPR 57. 

In restoring the context, the console pushes the user's PSL and PC onto 
the user's interrupt stack, then executes an REI from that stack. This 
implies that the user's ISP is valid before the firmware can exit. This is 
done automatically on a bootstrap. However, it is suggested that the SP is 
set to a valid memory location before issuing the START or CONTINUE 
command. Furthermore, the user should validate PR$_SCBB prior to 
executing a NEXT command, since the firmware utilizes the trace trap 
vector for this function. At power-up, the user ISP is set to 200 (hex) and 
PR$_SCBB is undefined. 

6.1.1.3 Halt Dispatch 

The action taken by the firmware on a halt is dependent primarily on the 
following information: 

• The Function switch, BDR<7>(ENB_HALT) 

• The halt action field, CPMBX<1:0>(HALT_ACTION) 

• The halt code, PR$_SAVPSL<13:8>(RESTART_CODE), in particular 
the power-up state 

In general, the Function switch governs whether external halt conditions 
are recognized by the KN210. The halt action field in the console program 
mailbox is a 2-bit field used by operating systems to force the firmware 
to enter the console, restart, or reboot following a halt, regardless of the 
setting of the Function switch. The halt (or restart) code is automatically 
deposited in PR$_SAVPSL on any processor restart operation. The action 
taken on a halt is summarized in Table 6—1. 



6—4 Maintenance Mode Firmware 



Table 6-1 Halt Action Summary 



Function 




Halt 




Switch 


Power-Up 


Action 


Action 


T 


T 


X 


diagnostics, halt 


T 


F 





halt 


F 


T 


X 


diagnostics, bootstrap, halt 


F 


F 





restart, bootstrap, halt 


X 


F 


1 


restart, halt 


X 


F 


2 


bootstrap, halt 


X 


F 


3 


halt 



"T" indicates that the condition is true. 
"F" indicates that the condition is false. 
"x" indicates that the condition is "don't care" 



NOTE 

This assumes that the operation switch is set to maintenance 

mode. 

Multiple actions mean that the first action is taken and only if it fails is 
the next action taken. Diagnostics are an exception, if diagnostics fail the 
console is entered. 

Because the KN210 does not support battery backed up main memory, an 
operating system restart operation is not attempted on a power-up. 

6.1.1.4 External Halts 

Several conditions can trigger an external halt (PR$_ 
SAVPSL<13:8>(RESTART_CODE) = 2), and different actions are taken 
depending on the condition. 



An external halt can be caused by: 



1. Pressing j Break | on the system console terminal, if halts are enabled 
(BDR<7>(ENB_HALT) = 1). 

2. Assertion of the BHALT line on the Q22-bus, if the SCR<14>(BHALT_ 
ENABLE) bit in the CQBIC is set. 

3. Negation of DCOK, if the SCR<7>(DCOK_ACT) bit is set. 



Maintenance Mode Firmware 6—5 



NOTE 

The switch labeled RESTART on some BA213 system enclosures 
negates DCOK. The negation of DCOK may also be asserted by the 
DEQNA sanity timer, or any other Q22-bus module that chooses to 
implement the Q22-bus restart/reboot protocol. 

6.1.2 Power-Up 

On a power-up, the maintenance mode firmware performs actions that 
are unique to this condition. Among these actions are initial power-up 
tests, identifying a console device, language query, and the remaining 
diagnostics. Certain actions are dependent on the state of the mode 
switch on the H3602-SA panel which has three settings: "test," "query," 
and "normal." This section describes the sequence of events which occurs 
on power-up. 

6.1 .2.1 Initial Power-Up Test 

The first action performed on power-up is the initial power-up test 
(IPT). The purpose of the IPT is to verify that the console private 
NVRAM is valid and if invalid to test and initialize the NVRAM. 
Prior to checking the NVRAM, the IPT waits for power to stabilize by 
monitoring SCR<5>(POK). Once power is stable, the IPT then tests to 
see if the backup batteries failed during the power failure by checking 
SSCCR<31>(BLO). If the batteries failed, then the IPT will initialize 
certain non-volatile data, such as the default boot device, to a known 
state. In any case, the IPT then initializes other data structures and 
performs a processor initialization. If the mode switch is set to "test," the 
IPT then tests the console serial line as described in Section 6.1.3. 

NOTE 

All IPT failures are considered fatal, and the KN210 will appear 
to "hang" with a value on the LEDs indicating the point of failure. 
See Table 6-2 for the LED codes. 

6.1.2.2 Locating a Console Device 

After the IPT has completed successfully, the firmware attempts to locate 
a console device and find out what type of device it is. Normally, this is 
the device attached to the console serial line. In this case, the firmware 
will send out a device attributes escape sequence to the console serial line 
to determine the type of terminal attached and the functions it supports. 
Terminals that do not respond to the device attributes request correctly 
are assumed to be hardcopy devices. 



6-6 Maintenance Mode Firmware 



Once a console device has been found, the firmware displays the KN210 
banner message, similar to the following: 

KN210-A VO.O 

The banner message contains the processor name and the version of the 
firmware. The letter code in the firmware version indicates whether the 
firmware is pre-field test ("X"), field test ("T") or an official release ("V"). 
The first digit indicates the major release number and the trailing digit 
indicates the minor release number. 

Next, if the designated console device supports DEC multinational 
character set (MCS) and either the battery failed during power failure 
or the mode switch is set to "query," the firmware prompts for the console 
language. The firmware first displays the language selection menu shown 
in Example 6—1. 

After the language query, the firmware invokes the ROM-based 
diagnostics, and eventually displays the console prompt. 

6.1.3 Mode Switch Set to "Test" 

If the mode switch is set to "test," the console serial line external loopback 
test is executed at the end of the IPT. The purpose of this test is to verify 
that the console serial line connections from the KN210 through the 
H3602-SA panel are intact. 

NOTE 

An external loopback connector should be inserted in the serial 
line connector on the H3602-SA panel prior to cycling power to 
invoke this test. 

During this test the firmware toggles between two states, active and 
passive, each a few seconds long and each displaying a different number 
on the LEDs. 

During the active state (about 3 seconds long), the LEDs are set to 7. 
In this state the firmware reads the baud rate and mode switch, then 
transmits and receives a character sequence. If the mode switch has been 
moved from the "test" position, the firmware exits the test and continues 
as if on a normal power-up. 

During the passive state (about 7 seconds long), the LEDs are set to 3. 

If at any time the firmware detects an error (parity, framing, overflow or 
no characters), the firmware hangs with a 7 on the LEDs. 



Maintenance Mode Firmware 6—7 



6.1.4 Mode Switch Set to "Query" 

If the mode switch is set to "query" (or the firmware detects that the 
battery failed during a power loss), the firmware queries the user for a 
language which is used for displaying critical system messages. 

The language query menu is shown in Example 6-1. 



1] 


Dansk 


2 


Deutsch (Deutschland/Osterreich) 


3 


Deutsch (Schweiz) 


4 


English (United Kingdom) 


5 


English (United States/Canada) 


6 


Espafiol 


7 


Francais (Canada) 


8 


Frangais (France/Belgique) 


9 


Francais (Suisse) 


10 


Italiano 


11 


Nederlands 


12 


Norsk 


13 


Portugues 


14 


Suomi 


15 


Svenska 


<: 


L. .15) : 


Exampl 


e 6-1 Language Selection Menu 



If no response is received within 30 seconds, the language defaults to 
English (United States/Canada). 

NOTE 

This action is only taken if the console device supports DEC MCS. 
Any console device that does not support DEC MCS, such as a 
VT100, defaults to English (United States/Canada). 

After this inquiry, the firmware proceeds as if the mode switch were set to 
"normal," as described in Section 6.1.5. 



6—8 Maintenance Mode Firmware 



Performing normal system tests. 

49. .48. .47. .4 6. .45. .44. .43. .42. .41. .40. .39. .38. .37. .36. .35. .34 
33. .32. .31. .30. .29. .28. .27. .26. .25. .24. .23. .22. .21. .20.. 19. .18 
17. .16. .15. .14. .13. .12. .11. .10. .09. .08. .07. .06. .05. .04. .03. . 
Tests completed. 



Example 6-2 Normal Diagnostic Countdown 
6.1.5 Mode Switch Set to "Normal" 

If the mode selected is "normal", then the next step in the power-up 
sequence is to execute the bulk of ROM-based diagnostics. In addition 
to message text, a countdown is displayed to indicate diagnostic test 
progress. A successful diagnostic countdown is shown in Example 6-2. 

In the case of diagnostic failures, a diagnostic register dump is performed 
similar to that shown in Example 6-3. Depending on the failure, the 
remaining diagnostics may execute and the countdown continue. For a 
detailed description of the register dump refer to Section 6.4. 

Performing normal system tests. 

49. .48. .47. .4 6. .45. .44. .43. .42. .41. .40. .39. .38. .37. .36. .35. .34. . 

?34 2 08 FF 00 0000 

P1=00000000 P2=00000003 P3=00000031 P4=00000011 P5=00002000 
P6=FFFFFFFF P7=00000000 P8=00000000 P9=00000000 P10=2005438F 
r0=00114B98 rl=FFFFFFFF r2=2005D2F0 r3=55555555 r4=AAAAAAAA 
r5=00000000 r6=AAAAAAAA r7=00000000 r8=00000000 ERF=80000180 
33. .32. .31. .30. .29. .28. .27. .26. .25. .24. .23. .22. .21. .20. .19. .18. . 
17. .16. .15. .14. .13.. 12.. 11.. 10. .09.. 08. .07.. 06.. 05. .04.. 03.. 
Normal operation not possible. 



Example 6-3 Abnormal Diagnostic Countdown 

If the diagnostics have successfully completed and halts are enabled, the 
firmware displays the console prompt (>») and enters console I/O mode. 



Maintenance Mode Firmware 6—9 



6.1.6 LED Codes 

In addition to the console diagnostic countdown, a hexadecimal value 
is displayed by the LEDs on the H3602-SA panel. The same value is 
displayed by the four red LEDs on the KN210 processor module. The 
purpose of the LED display is to improve fault isolation, when there is no 
console terminal or when the hardware is incapable of communicating 
with the console terminal. Table 6—2 lists all LED codes and the 
associated actions which are performed at power-up. The LED code is 
changed before the corresponding test or action is performed. 

Table 6-2 LED Codes 

LED 

Value Actions 

F Initial state on power-up, no code has executed 

E Entered ROM, some instructions have executed 

D Waiting for power to stabilize (POK) 

C SSC and ROM tests 

B CVAX tests 

A R3000 tests 

9 CMCTL and memory tests 

8 CQBIC (Q22-bus) tests 

7 Console loopback tests 

6 DSSI subsystem tests 

5 Ethernet subsystem tests 

4 CVAX console I/O mode 

3 R3000 console I/O mode 

2 CVAX primary/secondary bootstrap 

1 R3000 primary/secondary bootstrap 

Operating system running 



6.2 Console Service 

The KN210 is by definition halted whenever the console program is 
running and the triple angle prompt (>») is displayed on the console 
terminal. When halted, the firmware provides most of the services of a 
standard VAX console through the device that is designated as the system 
console. 



6—10 Maintenance Mode Firmware 

6.2.1 Console Control Characters 

In console I/O mode, several characters have special meanings. 



Return | — ends a command line. No action is taken on a command 
until after it is termina ted by a carriage-return. A null line 
terminated by a | Return | is treated as a valid, null command. No action 

is echoed as 



is taken, and the console re-prompts for input, 
carriage-return, line feed. 



Return 



Rubout — deletes the character that the operator previously typed. 



What appears on the console terminal depends on whether the 
terminal is a video termina l or a hardcopy terminal. For hardcopy 
terminals, when a | Rubout | is pressed, the console echoes with a 
backslash (\), foll owed by the character being deleted. If the operator 
presses additional | Rubout [ s, the additional characters deleted are 
echoed. When the operator types a non-rubout character, the console 
echoes another backslash, followed by the character typed. The result 
is to echo the characters deleted, surrounding them with backslashes. 



For example : 

The operator types: EXAMI;E<rubout><rubout>NE<CR> 

The console echoes: EXAMI;E\E; \NE<CR> 

The console sees the command line: EXAMINE <CR> 



For video terminals, when | Rubout | is pressed the previous character 
is erased from the screen and the cursor is restored to its previous 
position. 

The console does not delete characters past the begi nning of a 
command line. If the operator presses more | Rubout [ s than there 



are characters on the line, the extra rubouts are ignored. If | Rubout [ is 
pressed on a blank line, it is ignored. 

I Ctrl | jc] — causes the console to echo A C and to abort processing of a 
command. |Ctrl| |c] has no effect as part of a binary load data stream. 
Ctrl] g clears [Ctrl] |§, and reenables output stopped by [Ctrl] g. 



Maintenance Mode Firmware 6—11 



Ctrl) [o| — causes the console to throw away transmissions to the 
console terminal until the next |Ctrl| |5| is entered. |Ctrl| [5| is echoed as 



A 0<CR> when it disables output, but is not echoed when it reenables 
output. Output is reenabled if the console prints an error message, or 
if it prompts for a command from the terminal. Displaying a REPEAT 
command does not reenable output. When output is reenabled for 
reading a co mmand, the console prompt is displayed. Output is also 
enabled Ictril isl. 



Ctrl 1 — resumes output to the console terminal. Additional [Ctrl| JQJs 



are ignored. jOtrlj ||] and )Otrlj § are not echoed. 



Ctrl 



S] — stops output to the console terminal until [Ctrl| |Q] is typed 



Ctri] H and |Ctrl] @ are not echoed. 



| Ctrl I |D] — causes the console to echo A U<CR>, and deletes the entire 
line. If [Ctrl | [Dj is typed on an empty line, it is echoed, and the console 
prompts for another command. 



| Ctrl | (RJ — causes the console to echo <CRxLF> followed by the current 
command line. This function can be used to improve t he re adability 
of a command line that has been heavily edited. When |Ctrl| |C] is typed 
as p art of a command line, the console deletes the line as it does with 

'CtrllP. 



Break) - If the console is in console I/O mode, Break is equivalent to 



Ctrl| g, but is echoed as " A C". 



NOTE 

If the loc al con sole is in program I/O mode and halts are 

disabled, | Break | is ignored. If the console is in program I/O 



mode and halts are enabled, | Break | causes the processor to halt 
and enter console I/O mode. 

Control c hara cters are typed by pressing the character key while holding 
down the |Ctrll key. 

If an unrecognized control character (ASCII code less than 32 decimal or 
between 128 and 159 decimal) is typed, it is echoed as up arrow followed 
by the character with ASCII code 64 greater. For example, BEL (ASCII 
code 7) is echoed as " A G", since ca pital G is ASCII code 7+64=71. When 
a control character is deleted with [ Rubout [ it is echoed the same way. 
After echoing the control character, the console processes it like a normal 
character. Commands with control characters are invalid, unless they are 
part of a comment, and the console will respond with an error message. 



6—1 2 Maintenance Mode Firmware 



Note that control codes from 128 to 159, the CI control codes, cannot be 
entered by any present Digital terminal. The character with code 7 and 
the character with code 135 will both echo as " A G". 

6.2.2 Console Command Syntax 

The console accepts commands of lengths up to 80 characters. It responds 
to longer commands with an error message. The count does not include 
rubouts, rubbed out characters, or the terminating carriage-return. 

Commands may be abbreviated. Abbreviations are formed by dropping 
characters from the end of a keyword, as long as the resulting keyword is 
still unique. Most commands can be uniquely expressed with their first 
character. 

Multiple adjacent spaces and tabs are treated as a single space by the 
console. Leading and trailing spaces and tabs are ignored. Tabs are 
echoed as spaces. 

Command qualifiers can appear after the command keyword, or after any 
symbol or number in the command. A qualifier is any contiguous set of 
non whitespace characters that is started with a slash (ASCII code 47 
decimal). 

All numbers (addresses, data, counts) are in hexadecimal. Note, though, 
that symbolic register-names number the registers in decimal. The 
console does not distinguish between upper and lower case either in 
numbers or in commands; both are accepted. 

6.2.3 Console Command Keywords 

The firmware implements a variant of the VAX SRM console command 
set. The only commands defined in the VAX SRM and not supported by 
the KN210 are MICROSTEP, LOAD, and @. The CONFIGURE, HELP, 
MOVE, SEARCH and SHOW commands have been added to the command 
set to facilitate system debugging and access to system parameters. In 
general, however, the KN210 console is similar to other VAX consoles. 

Table 6-3 lists command and qualifier keywords. 



Maintenance Mode Firmware 6—13 



Table 6-3 Command, Parameter, and Qualifier Keywords 



Command Keywords 


Processor Control 


Data Transfer 


Console Control 


B*OOT 


D*EPOSIT 


CONFIGURE 


CONTINUE 


E*XAMINE 


F*IND 


H*ALT 


M*OVE 


R*EPEAT 


INITIALIZE 


SEA*RCH 


SET 


N*EXT 


X 


SH*OW 


START 


EXIT 


T*EST 


U*NJAM 




I 


SET & SHOW Parameter Keywords 




BO*OT 


BF*L(A)G 


DE*VICE 


DS*SI 


ET*HERNET 


H*OST 


L*ANGUAGE 


M*EMORY 


Q*BUS 


RL*V12 


U*QSSP 


VERS*ION 


Qualifier Keywords 




Address Space 




Data Control 


Control 


Command Specific 


/B 


/G 


/IN*STRUCTION 


/W 


/I 


/NO*T 


fh 


/P 


/R5: or/ 


/Q 


/V 


/RP*B or /ME*M 


/N: 


M 


/F*ULL 


/S*TEP: 


fU 


/DU*P or 

/MAINTENANCE 


/WR*ONG 




/DS*SIor/U*QSSP 

/DI*SKor/T*APE 

/SE*RVICE 


"*" indicates the minimal number of character that are required to uniquely identify the 


keyword. 







A complete summary of the console commands is provided in Table 6-5 
following the command descriptions. 



6—14 Maintenance Mode Firmware 



6.2.4 Console Command Qualifiers 

All qualifers in the console command syntax are global. That is, they may 
appear in any place on the command line after the command keyword. 

All qualifiers have unique meanings throughout the console, regardless of 
the command. For example, the 7B" qualifier always means byte. 

Table 6-6 is a summary of the qualifers recognized by the KN210 console. 

6.2.5 Command Address Specifiers 

Several commands take an address or addresses as arguments. In the 
context of the console, an address has two components, the address space, 
and the offset into that space. The console supports 6 address spaces: 
physical memory (/P qualifier), virtual memory (/V qualifier), general 
purpose registers (/G qualifier), internal processor registers (/I qualifier), 
protected memory (/U qualifier), and the PSL (/M qualifier). 

The address space that the console references is inherited from the 
previous console reference, unless explicitly specified. The initial address 
space reference is PHYSICAL. 

The KN210 console supports symbolic references to addresses. A symbolic 
reference simultaneously defines the address space for a given symbol. 
Table 6-4 lists the symbolic addresses supported by the console grouped 
according to address space. 

Table 6-4 Console Symbolic Addresses 

Symbol Address Symbol Address 

/G — General Purpose Registers 



RO 


00 


Rll 


OB 


Rl 


01 


R12 


OC 


R2 


02 


R13 


OD 


R3 


03 


R14 


OE 


R4 


04 


R15 


OF 


R5 


05 


AP 


OC 


R6 


06 


PP 


OD 


R7 


07 


SP 


OE 


R8 


08 


PC 


OF 


R9 


09 


PSL 






Note: All symbolic values in this table are in hexadecimal. 



Maintenance Mode Firmware 6—1 5 



Table 6-4 (Cont.) Console Symbolic Addresses 



Symbol 


Address 


Symbol 


Address 


/G — General Purpose Registers 


RIO 


OA 








H - Internal Processor Registers 


PR$_KSP 


00 




PR$_SISR 


15 


PR$_ESP 


01 




PR$_ICCR 


18 


PR$_SSP 


02 




PR$_RXCS 


20 


PR$_USP 


03 




PR$_RXDB 


21 


PR$_ISP 


04 




PR$_TXCS 


22 


PR$_POBR 


08 




PR$_TXDB 


23 


PR$_POLR 


09 




PR$_TBDR 


24 


PR$_P1BR 


0A 




PR$_CADR 


25 


PR$_P1LR 


0B 




PR$_MCESR 


26 


PR$_SBR 


OC 




PR$_MSER 


27 


PR$_SLR 


0D 




PR$_SAVPC 


2A 


PR$_PCBB 


10 




PR$_SAVPSL 


2B 


PR$_SCBB 


11 




PR$_ 
IORESET 


37 


PR$_IPL 


12 




PR$_MAPEN 


38 


PR$_ASTLV 


13 




PR$_TBIA 


39 


PR$_SIRR 


14 




PR$_TBIS 


3A 


PR$_NICR 


19 




PR$_SID 


3E 


PR$_ICR 


1A 




PR$_TBCHK 


3F 


PR$_TODR 


IB 












/P - Physical (VAX I/O Spa 


ice) 


QBIO 


2000 0000 


QBMEM 


3000 0000 


QBMBR 


2008 0010 






ROM 


2004 0000 






BDR 


2008 4004 






DSCR 


2008 0000 


DSER 


2008 0004 


DMEAR 


2008 0008 


DSEAR 


2008 000C 


IPCRO 


2000 1P40 






SSC.RAM 


2014 0400 


SSCCR 


2014 0010 



6—1 6 Maintenance Mode Firmware 



Table 6-4 (Cont.) Console Symbolic Addresses 



Symbol 


Address 


Symbol 


Address 




/p-: 


Physical (VAX I/O Space) 


SSC_CDAL 


2014 0020 


SSC_DLEDR 


2014 0030 


SSC_ 


2014 0130 


SSC_ 


2014 0134 


ADOMAT 




AD0MSK 




SSC_ 


2014 0140 


SSC_ 


2014 0144 


AD1MAT 




AD1MSK 




SSC.TCRO 


2014 0100 


SSC_TIR0 


2014 0104 


SSC.TNIRO 


2014 0108 


SSC_TIVR0 


2014 010C 


SSC_TCR1 


2014 0110 


SSC.TIRl 


2014 0114 


SSCJTNIR1 


2014 0118 


SSC_TTVR1 


2014 one 


MEMCSRO 


2008 0100 


MEMCSR1 


2008 0104 


MEMCSR2 


2008 0108 


MEMCSR3 


2008 010C 


MEMCSR4 


2008 0110 


MEMCSR5 


2008 0114 


MEMCSR6 


2008 0118 


MEMCSR7 


2008 011C 


MEMCSR8 


2008 0120 


MEMCSR9 


2008 0124 


MEMCSR10 


2008 0128 


MEMCSR11 


2008 012C 


MEMCSR12 


2008 0130 


MEMCSR13 


2008 0134 


MEMCSR14 


2008 0138 


MEMCSR15 


2008 013C 


MEMCSR16 


2008 0140 


MEMCSR17 


2008 0144 


Any Address Space 



The last location successfully referenced in an EXAMINE or 
DEPOSIT command. 

The location immediately following the last location successfully 
referenced in an EXAMINE or DEPOSIT command. For 
references to physical or virtual memory spaces, the location 
referenced is the last address, plus the size of the last reference 
(1 for byte, 2 for word, 4 for longword, 8 for quadword). For 
other address spaces, the address is the last address referenced 
plus one. 



Maintenance Mode Firmware 6—17 



Table 6-4 (Cont.) Console Symbolic Addresses 

Any Address Space 

"-" The location immediately preceding the last location 

successfully referenced in an EXAMINE or DEPOSIT command. 
For references to physical or virtual memory spaces, the 
location referenced is the last address minus the size of 
this reference (1 for byte, 2 for word, 4 for longword, 8 for 
quadword). For other address spaces, the address is the last 
addressed referenced minus one. 

"@" The location addressed by the last location successfully 

referenced in an EXAMINE or DEPOSIT command. 



6.2.6 References to Processor Registers and Memory 

The KN210 console is implemented by macrocode executing from 
EPROM. Actual processor registers cannot be modified by the console 
command interpreter. When the console is entered, the console saves 
the processor registers in console memory and all command references to 
them are directed to the corresponding saved values, not to the registers 
themselves. 

When the console reenters program I/O mode, the saved registers are 
restored and any changes become operative only then. References to 
processor memory are handled normally. The binary load and unload 
command cannot reference the console memory pages. 

The following registers are saved by the console, and any direct reference 
to these registers will be intercepted by the console and the access will be 
to the saved copies: 

R0...R15 - the general purpose registers. 

PR$_IPL - the interrupt priority level register. 

PR$_SCBB - the system control block base register. 

PR$_ISP - the interrupt stack pointer. 

PR$MAPEN - the memory management enable register. 

The following registers are also saved, yet may be accessed directly 
through console commands. Writing values to these registers may make 
the console inoperative. 



6—1 8 Maintenance Mode Firmware 

PR$_SAVPC - the halt PC. 

PR$_SAVPSL - the halt PSL. 

ADxMCH/ADxMSK - the SSC address decode and match registers. 

SSCCR - the SSC configuration register. 

DLEDR - the SSC diagnostic LED register. 

6.2.7 Console Commands 

The following sections define the commands accepted by the console, when 
it is in console I/O mode. The following conventions are used to describe 
command syntax: 

• [ ] - denotes command elements that are optional. 

• { } - denotes a command element. 

• ... - denotes a list of command elements. 

6.2.7.1 BOOT 

Format : 

BOOT [qualifier] [{boot_device}[:l] 

Description : 

The console initializes the processor and transfers execution to VMB. 
VMB attempts to boot the operating system from the specified device 
or the default boot device if none is specified. The console qualifies the 
bootstrap operation by passing a boot flags to VMB in R5. A more detailed 
description of the bootstrap process and how the default bootstrap device 
is determined is described in Section 6.3. 

In the case where either the qualifiers or the device name is absent, then 
the corresponding default value is used. Explicitly stating the boot flags 
or the boot device overrides the current default value for the current boot 
request, but does not change the corresponding default value in NVRAM. 

There are three mechanisms by which the default boot device and boot 
flags may be set. 

1. The operating system may write a default boot device and flags into 
the appropriate locations in NVRAM (Section 6.7.3). 



Maintenance Mode Firmware 6—19 



2. The user may explicity set the default boot device and boot flags with 
the console SET BOOT and SET BFIAG commands respectively. 

3. The console will prompt the user for the default boot device, if any of 
the following conditions are met: 

• The power-up mode switch is set to "query" mode. 

• The console detects that the battery failed, and therefore the 
contents of NVRAM are no longer valid. 

• The console detects that the default boot device has not been 
explicitly set by the user. Either a previous device query timed out 
and defaulted to ESAO or neither (1) nor (2) has been performed. 
Simply stated, the console will prompt the user on each and every 
power-up for a default boot device, until such a request has been 
satisfied. 

On power-up if no default boot device is specified in NVRAM, the console 
issues a list of potential bootable devices and then queries the user for 
a device name. If no device name is entered within 30 seconds, ESAO is 
used. However, ESAO does not become the "default" boot device. 

Qualifiers : 

• /R5:{boot_flags} Boot flags is a 32-bit hex value, that is passed 
to VMB in R5. No interpretation of this value is performed by the 
console. Refer to Figure 6-1 for the bit assignments of R5. A default 
boot flags longword may be specified using the SET BFLAG command 
and displayed with the SHOW BFLAG command. 

• /{boot_flags} Equivalent to the form above. 
Arguments : 

• [{boot_device}] The boot device name may be any arbitrary 
character string, with a maximum length of 17 characters. Longer 
strings cause a "VAL TOO BIG" error message to be issued from the 
console. Otherwise the console makes no attempt at interpretting 
or validating the device name. The console converts the string to 
all upper case, and passes VMB a string descriptor to this device 
name in R0. A default boot device may be specified using the SET 
BOOT command and displayed with the SHOW BOOT command. The 
factory default device is the Ethernet port, ESAO. 



6—20 Maintenance Mode Firmware 



Examples : 



>»show boot 

DUAO 

>»show bf lag 


»>b 

(BOOT/R5:0 DUAO) 



! Boot using default boot flags and device, 



2. . 
-DUAO 

>»bo xqaO 
(BOOT/R5:0 XQAO) 



! Boot using default boot flags and specified device 



2. . 
-XQAO 

»>boot/10 
(BOOT/R5:10 DUAO) 



! Boot using specified boot flags and default device 



2. . 

-DUAO 

>»boot /r5:220 xqaO ! Boot using specified boot flags and device, 
(BOOT/R5:220 XQAO) 

2. . 
-XQAO 



6.2.7.2 CONFIGURE 

Format : 

CONFIGURE 

Description : 

CONFIGURE is similar to the VMS SYSGEN CONFIG utility. This 
feature simplifies system configuration by providing information that is 
typically available only with a running operating system. 

The CONFIGURE command invokes an interactive mode that permits the 
user to enter Q22-bus device names, then generates a table of Q22-bus 
I/O page device CSR addresses and device vectors. 



Maintenance Mode Firmware 6—21 



Qualifiers : 
None 

Arguments 
None 

Examples : 



>»conf ig 

Enter device configuration, 
Device, Number? help 
Devices : 



HELP, or EXIT 



LPV11 


KXJ11 




DZQ11 


DZV11 


DFA01 




TSV05 


RXV21 


DRV11W 


DRV11B 


DPV11 


DMV11 


DELQA 


DEQNA 


DESQA 


RQDX3 


KDA50 


RRD50 


RQC25 


KFQSA-DISK 


TQK50 


TQK70 


TD81E 


RV20 


KFQSA-TAPE 


KMV11 


IEQ11 


DHQ11 


DHV11 


CXA16 


CXB16 


CXY08 


VCB01 


QVSS 


LNV11 


LNV21 


QPSS 


DSV11 


ADV11C 


AAV11C 


AXV11C 


KWV11C 


ADV11D 


AAV11D 


VCB02 




DRV11J 


DRQ3B 


VSV21 


IBQ01 


IDV11A 


IDV11B 


IDV11C 


IDV11D 


IAV11A 


I AVI IB 


MIRA 


ADQ32 


DTC04 


DESNA 


IGQ11 










Numbers : 












1 to 255, default is 1 










Device, Number 


? rqdx3,2 










Device, Number 


? dhvll 










Device, Number 


? tqk50 










Device , Number 


? tqk70 










Device, Number 


? exit 











Address /Vector Assignments 
-772150/154 RQDX3 
-760334/300 RQDX3 
-774500/260 TQK50 
-760444/304 TQK70 
-760500/310 DHV11 
>» 



6-22 Maintenance Mode Firmware 

6.2.7.3 CONTINUE 

Format : 

CONTINUE 

Description : 

The processor begins instruction execution at the address currently 
contained in the program counter. Processor initialization is not 
performed. The console enters program I/O mode. Internally, the continue 
command pushes the user's PC and PSL onto the user's ISP, and then 
executes an REI instruction. This implies that the user's ISP is pointing 
to some valid memory. 

Qualifiers : 

None 
Arguments : 

None 
Examples : 

>»continue 
»> 

6.2.7.4 DEPOSIT 

Format : 

DEPOSIT [qualifierjist] {address} {data} [{data}...] 

Description : 

Deposits the data into the address specified. If no address space or data 
size qualifiers are specified, the defaults are the last address space and 
data size used in a DEPOSIT, EXAMINE, MOVE or SEARCH command. 
After processor initialization, the default address space is physical 
memory, the default data size is a longword and the default address is 
zero. If conflicting address space or data sizes are specified, the console 
ignores the command and issues an error message. 



Maintenance Mode Firmware 6—23 



Qualifiers : 

• /B — The data size is byte. 

• /W — The data size is word. 

• /L — The data size is longword. 

• /Q — The data size is quadword. 

• /G — The address space is the general purpose register set, RO 
through R15. The data size is always long. 

• /I — The address space is internal processor registers (IPRs). These 
are the registers only accessible by the MTPR and MFPR instructions. 
The data size is always long. 

• /M — The address space is the processor status longword (PSL). 

• /P — The address space is physical memory. 

• /V — The address space is virtual memory. All access and protection 
checking occur. If the access would not be allowed to a program 
running with the current PSL, the console issues an error message. 
'Virtual space DEPOSITS cause the PTE<M> bit to be set. If memory 
mapping is not enabled, virtual addresses are equal to physical 
addresses. 

• /U — Access to console private memory is allowed. This qualifier also 
disables virtual address protection checks. On virtual address writes, 
the PTE<M> bit will not be set if the /U qualifier is present. This 
qualifier is not inherited, and must be respecified on each command. 

• /N:{count} — The address is the first of a range. The console 
deposits to the first address, then to the specified number of 
succeeding addresses. Even if the address is the symbolic address 
(-), the succeeding addresses are at larger addresses. The symbolic 
address specifies only the starting address, not the direction of 
succession. For repeated references to preceding addresses, use 
REPEAT DEPOSIT - <DATA>. 

• /STEP:{size} — The number to add to the current address. 
Normally this defaults to the data size, but is overriden by the 
presence of this qualifier. This qualifier is not inherited. 

• /WRONG — The ECC bits for this data forced to a value of 3 (ECC 
bits of 3 will always generate a double bit error). 



6—24 Maintenance Mode Firmware 



Arguments : 

• {address} — A long word address that specifies the first location 
into which data is deposited. The address can be any legal address 
specifier as defined in Section 6.2.5 and Table 6—4. 

• {data} — The data to be deposited. If the specified data is larger 
than the deposit data size, the console ignores the command and 
issues an error response. If the specified data is smaller than the 
deposit data size, it is extended on the left with zeros. 

• [{data}] — Additional data to be deposited (up to a maximum of 6 
values). 

Examples : 

>»d/p/b/n:lFF 
>»d/v/l/n:3 1234 5 

»>d/n:8 RO FFFFFFFF 
»>d/n:200 - 
>»d/l/p/n:10/s:200 8 

>» 

6.2.7.5 EXAMINE 

Format : 



Clear first 512 bytes of physical memory. 

Deposit 5 into four longwords starting at 
virtual memory address 1234 . 
Loads GPRs RO through R8 with -1. 

Starting at previous address, clear 513 bytes. 

Deposit 8 in the first longword of 
the first 17 pages in physical memory. 



EXAMINE [qualifierjist] [{address}] 

Description : 

Examines the contents of the memory location or register specified by the 
address. If no address is specified, + is assumed. The display line consists 
of a single character address specifier, the hexadecimal physical address 
to be examined, and the examined data also in hexadecimal. 

EXAMINE uses the same qualifiers as DEPOSIT. However, the /WRONG 
qualifier will cause examines to ignore ECC errors on reads from 
physical memory. Additionally, the examine command supports an 
/INSTRUCTION qualifier, which will disassemble the instructions at 
the current address. 



Maintenance Mode Firmware 6—25 



Qualifiers : 

• /B — The data size is byte. 

• /W — The data size is word. 

• PL — The data size is longword. 

• /Q — The data size is quadword. 

• /G — The address space is the general purpose register set, RO 
through R15. The data size is always long. 

• /I — The address space is internal processor registers (IPRs). These 
are the registers only accessible by the MTPR and MFPR instructions. 
The data size is always long. 

• /M — The address space is the processor status longword (PSL). 

• /P — The address space is physical memory. Note that when virtual 
memory is examined, the address space and address in the response 
are the translated physical address. 

• /V — The address space is virtual memory. All access and protection 
checking occur. If the access would not be allowed to a program 
running with the current PSL, the console issues an error message. 
If memory mapping is not enabled, virtual addresses are equal to 
physical addresses. 

• /M — The address space and display are the PSL. The data size is 
always long. 

• /U — Access to console private memory is allowed. This qualifier 
also disables virtual address protection checks. This qualifier is not 
inherited, and must be respecified with each command. 

• /N: {count} — The address is the first of a range. The console 
deposits to the first address, then to the specified number of 
succeeding addresses. Even if the address is the symbolic address 
(-), the succeeding addresses are at larger addresses. The symbolic 
address specifies only the starting address, not the direction of 
succession. For repeated references to preceding addresses, use 
REPEAT EXAMINE - <DATA>. 

• /STEP:{size} — The number to add to the current address. 
Normally this defaults to the data size, but is overridden by the 
presence of this qualifier. This qualifier is not inherited. 



6—26 Maintenance Mode Firmware 



/WRONG 

ignored. 



ECC errors on this read access to main memory are 



/INSTRUCTION — Disassemble and display the VAX Macro-32 
instruction at the specified address. 



Arguments 



[{address}] — A longword address that specifies the first location 
to be examined. The address can be any legal address specifier as 
denned in Section 6.2.5 and Table 6—4. If no address is specified, + is 
assumed. 



Examples 



>»e pc 

G 0O0OOOOF FFFFFFFC 

>»e sp 

G 0O0O0OOE 00000200 

>»e psl 

M 00000000 041FOOO0 

>»e/m 

M 00000000 041F00O0 

»>e r4/n:5 

G 00000004 00000000 
G 00000005 00000000 
G 00000006 00000000 
G 00000007 00000000 
G 00000008 00000000 
G 00000009 801D9000 

>»e pr$_scbb 

I 00000011 2O04A0O0 

»>e/p 

P 00000000 00000000 

>»e /ins 20040000 



Examine the PC. 
Examine the SP . 
Examine the PSL. 
Examine PSL another way. 
Examine R4 through R9. 



! Examine the SCBB, IPR 17 . 

! Examine local memory . 

! Examine 1st byte of EPROM. 



P 20040000 


11 BRB 


20040019 


>»e /ins/n:5 


20040019 


! Disassemble from branch. 


P 20040019 


DO MOVL 


I A #20140000, ©#20140000 


P 20040024 


D2 MCOML 


©#20140030, ©#20140502 


P 2004002F 


D2 MCOML 


S A #0E, ©#20140030 


P 20040036 


7D MOVQ 


R0,@#201404B2 


P 2004003D 


DO MOVL 


I A #201404B2,R1 


P 20040044 


DB MFPR 


S A #2A,B A 44(R1) 


>»e/ins 




! Look at next instruction . 


P 20040048 


DB MFPR 


S A #2B,B A 48(R1) 


>» 







Maintenance Mode Firmware 6—27 



6.2.7.6 EXIT 

Format : 

EXIT 

Description : 

EXIT from maintenance mode and Start/Return to the operational 
(R3000) console. This command will idle the CVAX CPU. Executing 
the maintenance command on the operational (R3000) console will return 
control to CVAX and return the user to the maintenance mode prompt. 
The EXIT command implementation should comply with the following 
guidelines: 

• Prior to execution of the command, all errors must be handled. 

• Steps of the EXIT command are: 

1. Q22-bus map must be disabled. 

2. Turn off interrupts to the CVAX. 

3. SPR<31> set to 1. 
Qualifiers : 

None 
Arguments : 

None 
Examples : 

>»exit ! Return to operational console. 

»maint ! Enter the maintenance console. 

>» 



6—28 Maintenance Mode Firmware 

6.2.7.7 FIND 

Format : 

FIND [qualifier-list] 

Description : 

The console searches main memory starting at address zero for a page- 
aligned 128 Kbyte segment of good memory, or a restart parameter block 
(RPB). If the segment or block is found, its address plus 512 is left in SP 
(R14). If the segment or block is not found, an error message is issued, 
and the contents of SP are preserved. If no qualifier is specified, /RPB is 
assumed. 

Qualifiers : 

• /MEMORY — Search memory for a page aligned block of good 
memory, 128 Kbytes in length. The search looks only at memory that 
is deemed usable by the bitmap. This command leaves the contents of 
memory unchanged. 

• /RPB — Search all of physical memory for a restart parameter block. 
The search does not use the bitmap to qualifiy which pages are looked 
at. The command leaves the contents of memory unchanged. 

Arguments : 

None 

Examples : 



>»e sp 

G 0000000E 00000000 
>»find /mem 
>»e sp 

G 0O0O000E 00000200 
>»find /rpb 
?2C FND ERR 0OCO0004 
>» 



! Check the SP . 

! Look for a valid 128 Kbytes. 
! Note where it was found. 

! Check for valid RPB. 
! None to be found here. 



Maintenance Mode Firmware 6—29 



6.2.7.8 HALT 

Format : 

HALT 

Description : 

This command has no effect and is included for compatability with other 
consoles. 

Qualifiers : 

None 
Arguments : 

None 
Examples : 

>»halt ! Pretend to halt. 

>» 

6.2.7.9 HELP 

Format : 

HELP 

Description : 

This command has been included to help the console operator answer 
simple questions about command syntax and usage. 

Qualifiers : 

None 
Arguments : 

None 



6—30 Maintenance Mode Firmware 



Examples : 

>»help 

Following is a brief summary of all the commands supported by the console: 

UPPERCASE denotes a keyword that you must type in 
| denotes an OR condition 

[] denotes optional parameters 

<> denotes a field that must be filled in 

with a syntactically correct value 

Valid qualifiers : 

/B /W /L /Q /INSTRUCTION 
/G /I /V /P /M 
/STEP: /N: /NOT 
/WRONG /U 

Valid commands : 

DEPOSIT [<qualif iers>] <address> [<datum> [<datum>] ] 

EXAMINE [<qualifiers>] [<address>] 

MOVE [<qualifiers>] <address> <address> 

SEARCH [<qualifiers>] <address> <pattern> [<mask>] 

SET BFL(A)G <boot_flags> 

SET BOOT <boot_device> [ : ] 

SET HOST/DUP/DSSI <node_number> [<TASK>] 

SET HOST/DUP/UQSSP </DISK | /TAPE> <controller_number> [<task>] 

SET HOST/DUP/UQSSP <physical_CSR_address> [<task>] 

SET HOST/MAINTENANCE/UQSSP/SERVICE <controller_number> 

SET HOST/MAINTENANCE/UQSSP <physical_CSR_address> 

SET LANGUAGE <language_number> 

SHOW BFL(A)G 

SHOW BOOT 

SHOW DEVICE 

SHOW DSSI 

SHOW ETHERNET 

SHOW LANGUAGE 

SHOW MEMORY [/FULL] 

SHOW QBUS 

SHOW UQSSP 

SHOW VERSION 

HALT 

INITIALIZE 

UN JAM 

CONTINUE 

EXIT 



Maintenance Mode Firmware 6—31 



START <address> 
REPEAT <command> 
X <address> <count> 
FIND [/MEMORY | /RPB] 
TEST [<test_code> [<parameters>] ] 

BOOT [ /R5 : <boot_f lags> | /<boot_f lags>] [<boot_device> [ : ] ] 
NEXT [cotint] 
CONFIGURE 
HELP 
>» 

6.2.7.10 INITIALIZE 

Format : 

INTIXALIZE 

Description : 

A processor initialization is performed. The following registers are 
initialized. 



Register 



Initialized Value 



PSL 


041F0OO0 


IPL 


IF 


ASTLVL 


4 


SISR 





ICCS 


Bits <6> and <0> are clear, tl 
UNPREDICTABLE. 


RXCS 





TXCS 


80 


MAPEN 





CPU cache 


Disabled, all entries invalid 


Instruction buffer 


Unaffected 


Console previous 
reference 


Longword, physical, address 



TODR 



Unaffected 



6—32 Maintenance Mode Firmware 



Register Initialized Value 



Main memory Unaffected 

General registers Unaffected 

Halt code Unaffected 

Bootstrap in progress Unaffected 
flag 

Internal restart in Unaffected 
progress flag 



The maintenance mode firmware performs the following additional 
initialization: 

The CDAL bus timer is initialized. 

The address decode and match registers are initialized. 

The programmable timer interrupt vectors are initialized. 

The BDR registers are read to determine the baud rate, and then the 
SSCCR is configured accordingly. 

All error status bits are cleared. 
Qualifiers : 

None 
Arguments : 

None 
Examples : 

>»init 
>» 



Maintenance Mode Firmware 6—33 



6.2.7.11 MOVE 

Format : 

MOVE [qualifier-list] {src_address} {dest_address} 

Description : 

The console copies the block of memory starting at the source address to 
a block beginning at the destination address. Typically, this command 
is used with the /N: qualifier to transfer large blocks of data. The 
destination will correctly reflect the contents of the source, regardless 
of the overlap between the source and the data. 

The MOVE command actually performs byte, word, longword, and 
quadword reads and writes as needed in the process of moving the data. 
Moves are only supported for the PHYSICAL and VIRTUAL address 
spaces. 

Qualifiers : 

/B — The data size is byte. 

/W — The data size is word. 

/L — The data size is longword. 

/Q — The data size is quadword. 

/P — The address space is physical memory. 

IV — The address space is virtual memory. All access and protection 
checking occur. If the access would not be allowed to a program 
running with the current PSL, the console issues an error message. 
Virtual space MOVEs cause the destination PTE<M> bit to be set. 
If memory mapping is not enabled, virtual addresses are equal to 
physical addresses. 

/U — Access to console private memory is allowed. This qualifier also 
disables virtual address protection checks. On virtual address writes, 
the PTE<M> bit will not be set if the /U qualifier is present. This 
qualifier is not inherited, and must be respecified on each command. 

/N:{count} — The address is the first of a range. The console 
deposits to the first address, then to the specified number of 
succeeding addresses. Even if the address is the symbolic address 
(-), the succeeding addresses are at larger addresses. The symbolic 
address specifies only the starling address, not the direction of 
succession. 



6—34 Maintenance Mode Firmware 



• /STEP:{size} — The number to add to the current address. 
Normally this defaults to the data size, but is overridden by the 
presence of this qualifier. This qualifier is not inherited. 

• /WRONG — On reads, ECC errors on the access of data in main 
memory are ignored. On writes, the ECC bits for this data are forced 
to a value of 3. 

Arguments : 

• {src_address} — A longword address that specifies the first location 
of the source data to be copied. 

• {dest_address} — A longword address that specifies the destination 
of the first byte of data. These addresses may be any legal address 
specifier as defined in Section 6.2.5 and Table 6-4. If no address is 
specified, + is assumed. 

Examples : 



>»e /n:4 
P 00000000 
P 00000004 
P 00000008 
P O0OOO00C 
P 00000010 

>»e /n:4 200 
P 00000200 
P 00000204 
P 00000208 
P 0000020C 
P 00000210 

>»move /n : 4 

>»e /n:4 
P 00000000 
P 00000004 
P 00000008 
P OOOOOOOC 
P 00000010 

>» 



! Observe destination. 



00000000 
00000000 
00000000 
00000000 
00000000 

58DD0520 
585E04C1 
00FF8FBB 
5208A8D0 
540CA8DE 
200 

58DD0520 
585E04C1 
00FF8FBB 
5208A8D0 
540CA8DE 



! Observe source data, 



! Move the data. 

! Observe the destination. 



Maintenance Mode Firmware 6—35 



6.2.7.12 NEXT 

Format : 

NEXT {count} 

Description : 

The NEXT command causes the processor to "step" the specified number 
of macro instructions. If no count is specified, "single-step" is assumed. 
The console does not however enter "Spacebar Step Mode" as described in 
the VAX Architecture Reference Manual, but rather returns to the console 
prompt. 

The console uses the trace and trace pending bits in the PSL, and the 
SCB trace pending vector to implement the NEXT function. This creates 
the following restrictions on the usage of the NEXT command: 

• If memory management is enabled, the NEXT command works if 
and only if the first page in SSC RAM is mapped somewhere in SO 
(system) space. 

• The NEXT command, due to the instructions executed in 
implementation, does not work where time critical code is being 
executed. 

• The NEXT command elevates the IPL to 31 for long periods of time 
(milliseconds) while single stepping over several commands. 

• Unpredictable results occur if the macro instruction being stepped 
over modifies the SCBB, or the trace trap entry. This means that the 
NEXT command cannot be used in conjunction with other debuggers. 
This also implies that the user should validate PR$_SCCB before 
using the NEXT command. 

Qualifiers : 

None 

Arguments : 

• {count} — A value representing the number of macro instructions to 
execute. 



6—36 Maintenance Mode Firmware 



Examples 



>»dep 1000 50D650D4 




>»dep 1004 125005D1 




>»dep 1008 00FE11F9 




>»e /instruct 


ion 


/n:5 


1000 


P 00001000 


D4 


CLRL 


R0 


P 00001002 


D6 


INCL 


R0 


P 00001004 


Dl 


CMPL 


S^#05,R0 


P 00001007 


12 


BNEQ 


00001002 


P 00001009 


11 


BRB 


00001009 


P 0000100B 


00 


HALT 




>»dep pr$ scbb 200 




>»dep pc 1000 








>» 








>»n 








P 00001002 


D6 


INCL 


R0 


>»n 








P 00001004 


Dl 


CMPL 


S A #05,R0 


>»n 








P 00001007 


12 


BNEQ 


00001002 


»>n 








P 00001002 


D6 


INCL 


RO 


»>n 5 








P 00001004 


Dl 


CMPL 


S"#05,RO 


P 00001007 


12 


BNEQ 


00001002 


P 00001002 


D6 


INCL 


RO 


P 00001004 


Dl 


CMPL 


S^#05,R0 


P 00001007 


12 


BNEQ 


00001002 


>»n 7 








P 00001002 


D6 


INCL 


RO 


P 00001004 


Dl 


CMPL 


S"#05,RO 


P 00001007 


12 


BNEQ 


00001002 


P 00001002 


D6 


INCL 


RO 


P 00001004 


Dl 


CMPL 


S A #05,R0 


P 00001007 


12 


BNEQ 


00001002 


P 00001009 


11 


BRB 


00001009 


>»n 








P 00001009 


11 


BRB 


00001009 


>» 








6.2.7.13 REPEAT 






Format : 









! Create a simple program. 



! List it. 



! Set up a user SCBB , 
! ... and the PC . 

! Single. . . 



, or multiple step the program. 



REPEAT {command} 



Maintenance Mode Firmware 6—37 



Description : 

The c onso le repeatedly displays and executes the specified command. 
Press | Ctrl | jc] to stop the repeating. Any valid console command can be 
specified for the command with the exception of the REPEAT command. 

Qualifiers : 

None 

Arguments : 

• {command} — A valid console command other than REPEAT. 

Examples : 

>»repeat e pr$_todr ! Watch the clock. 

I 0000001B 5AFE78CE 

I 0000001B 5AFE78D1 

I 0000001B 5AFE78FD 

I 0000001B 5AFE7900 

I 0000001B 5AFE7903 

I 0000001B 5AFE7907 

I O0O0001B 5AFE790A 

I O0O0001B 5AFE790D 

I 0000001B 5AFE7910 

I 0000001B 5AFE793C 

I 0000001B 5AFE793F 

I 0000001B 5AFE7942 

I 0000001B 5AFE7946 

I 0000001B 5AFE7949 

I O0O0O01B 5AFE794C 

I 0000001B 5AFE794F 

I 0000001B 5 A C 
>» 

6.2.7.14 SEARCH 

Format : 

SEARCH [qualifierjist] {address} {pattern} [{mask}] 

Description : 

The search command finds all occurrences of a pattern, and reports the 
addresses where the pattern was found. If the /NOT qualifier is present, 
all addresses where the pattern did not match are reported. 



6-38 Maintenance Mode Firmware 



The command accepts an optional mask that indicates don't care bits. For 
example, to ignore bit in the comparison, specify a mask of 1. The mask, 
if not present, defaults to 0. 

Conceptually, a match condition occurs if the following condition is true: 

(pattern AND NOT mask) EQUALS (data AND NOT mask) 

where : 

pattern — is the target data. 

mask — is the optional don't care bitmask (which defaults to 0) . 

data — is the data (byte, word, long, quad) at the current address, 

The command reports the address if the match condition is true, and 
there is no /NOT qualifier, or if the match condition is false and there is a 
/NOT qualifier. Stating this in a tabular form: 

/NOT Qualifier Match Condition Action 



absent 


true 


absent 


false 


present 


true 


present 


false 



report address 
no report 
no report 
report address 

The address is advanced by the size of the pattern (byte, word, long or 
quad), unless overriden by the /STEP qualifier. 

Qualifiers : 

• /B — The data size is byte. 

• /W — The data size is word. 

• /L — The data size is longword. 

• /Q — The data size is quad word. 

• /P — The address space is physical memory. Note that when virtual 
memory is examined, the address space and address in the response 
are the translated physical address. 



Maintenance Mode Firmware 6—39 



• /V — The address space is virtual memory. All access and protection 
checking occur. If the access would not be allowed to a program 
running with the current PSL, the console issues an error message. 
If memory mapping is not enabled, virtual addresses are equal to 
physical addresses. 

• /U — Access to console private memory is allowed. This qualifier 
also disables virtual address protection checks. This qualifier is not 
inherited, and must be respecified with each command. 

• /N:{count} — Trie address is the first of a range. The first access 
is to the address specified, then subsequent accesses are made to 
succeeding addresses. Even if the address is the symbolic address 
(-), the succeeding addresses are at larger addresses. The symbolic 
address specifies only the starting address, not the direction of 
succession. 

• /STEP:{size} — The number to add to the current address. 
Normally this defaults to the data size, but is overriden by the 
presence of this qualifier. This qualifier is not inherited. 

• /WRONG — ECC errors on read accesses to main memory are 
ignored. 

• /NOT — Inverts the sense of the match. 
Arguments : 

• {start_address} — A longword address that specifies the first 
location subject to the search. This address can be any legal address 
specifier as defined in Section 6.2.5 and Table 6-4. If no address is 
specified, + is assumed. 

• {pattern} — The target data. 

• [{mask}] — A longword containing the bits in the target which are 
to be masked out. 



6-40 Maintenance Mode Firmware 



Examples 



>»dep /p/l/n:1000 

»> 

>»dep 300 12345678 

>»dep 4 01 12345678 

>»dep 502 87654321 

>» 

>»search /n:1000 /st:l 12345678 

P 00000300 12345678 

P 00000401 12345678 
»>search /n:1000 12345678 

P 00000300 12345678 
>»search /n:1000 /not 

P 00000300 12345678 

P 00000400 34567800 

P 00000404 00000012 

P 00000500 43210000 

P 00000504 00008765 
»>search /n:1000 /st:l 1 FFFFFFFE 

P 00000502 87654321 

P 00000503 00876543 

P 00000504 00008765 

P 00000505 00000087 
»>search /n:1000 /b 12 

P 00000303 12 

P 00000404 12 
>»search /n:1000 /st:l /w FE11 
»> 
>» 
»> 



! Clear some memory. 

! Deposit some "search" data. 



Search for all occurances. 

...of 12345678 on any byte. 

. . . boundary . 

Then try on longword. . . 

. . . boundaries . 

Search for all non-zero... 

. . . longwords . 



! Search for "odd" longwords, 
! ... on any boundary . 



! Search for all occurrances. 
! ... of the byte 12 . 

! Search for all words which. , 
! ... could be interpretted as 
! ...a "spin" (10$: brb 10$). 
! Note, none found. 



6.2.7.15 SET 

Format : 



SET {parameter} {value} 

Description : 

Sets the indicated console parameter to the indicated value. The following 
are console parameters and their acceptable values: 

Parameters : 

• BFL(A)G — Set the default R5 boot flags. The value must be a 
hexadecimal number of up to 8 hex digits. 

• BOOT — Set the default boot device. The value must be a valid 
device name as specified in Section 6.2.7.1 on the BOOT command. 



Maintenance Mode Firmware 6-41 



HOST — Invoke the DUP or MAINTENANCE driver on the 
selected node. Only SET HOST /DUP accepts a value parameter. 
The hierarchy of the SET HOST qualifiers listed below suggests 
the appropriate usage. Each qualifier only supports the additional 
qualifiers at levels below it. 

/DUP — Use the DUP protocol to examine/modify parameters 
of a device on either the DSSI bus or the Q22-bus. The optional 
value for SET HOST /DUP is a task name for the selected DUP 
driver to execute. 

NOTE 

The KN210 DUP driver only supports SEND DATA 
IMMEDIATE messages, and hence those devices which 
also support them. 

/DSSI — Select the DSSI node, where node is a number from 
to 7. 

/UQSSP — Select the Q22-bus device using one of the following 
three methods. 

/DISK n — Specify the disk controller number, where n 
is from to 255. (The resulting fixed address for n=0 is 
20001468 and the floating rank for n>0 is 26.) 

/TAPE n — Specify the tape controller number, where 
n is from to 255. (The resulting fixed address for n=0 is 
20001940 and the floating rank for n>0 is 30.) 

csr_address — Specify the Q22-bus I/O page CSR address 
for the device. 

/MAINTENANCE — Use the MAINTENANCE protocol to 
examine/modify KFQSA EEPROM configuration parameters. Note 
that SET HOST /MAINTENANCE does not accept a task value. 

/UQSSP — 

/SERVICE n — Specify the KFQSA controller number n of a 
KFQSA in service mode, where n is from to 3. (The resulting 
fixed address of a KFQSA in service mode is 20001910+4*n.) 

csr address — Specify the Q22-bus I/O page CSR address 
for the KFQSA. 



6-42 Maintenance Mode Firmware 



LANGUAGE — Set console language and keyboard type. If the 
current console terminal does not support the Digital multinational 
character set (MCS), then this command has no effect and the console 
remains in English message mode. Acceptable values are 1 through 
15 and have the following meaning: 

1) Dansk 

2) Deutsch (Deutschland/Osterreich) 

3) Deutsch (Schweiz) 

4) English (United Kingdom) 

5) English (United States/Canada) 

6) Espanol 

7) Francais (Canada) 

8) Francais (France/Belgique) 

9) Francais (Suisse) 

10) Italiano 

11) Nederlands 

12) Norsk 

13) Portugues 

14) Suomi 

15) Svenska 



Qualifiers : 

On a per parameter basis 
Arguments : 

None 
Examples : 



>» 

>»set bflag 220 

>» 

>»set boot duaO 

>» 

>»set host / dup / dssi 

Starting DUP server. . . 



Maintenance Mode Firmware 6—43 



DSSI Node (SUSAN) 

Copyright 1988 Digital Equipment Corporation 

5-Jul-1988 15:33:06 

5-Jul-1988 15:33:06 

5-Jul-1988 15:33:06 

5-Jul-1988 15:33:06 

5-Jul-1988 15:33:06 

5-Jul-1988 15:33:06 
End of directory 

Task Name? params 

Copyright 1988 Digital Equipment Corporation 

PARAMS> stat path 

ID Path Block Remote Node DGS S DGS R 



DRVEXR 


VI. 


.0 


D 


DRVTST 


VI. 


.0 


D 


HIS TRY 


VI. 


.0 


D 


ERASE 


VI. 


.0 


D 


PARAMS 


VI. 


.0 


D 


DIRECT 


VI. 


.0 


D 



MSGS S MSGS R 



PB 


FF811ECC 


Internal 


Path 


6 PB 


FF811FD0 


KFQSA KFX 


VI. 


1 PB 


FF8120D4 


KAREN RFX 


V101 


4 PB 


FF8121D8 


WILMA RFX 


V101 


5 PB 


FF8122DC 


BETTY RFX 


VI 01 


2 PB 


FF8123E0 


DSSI1 VMS 


V5.0 


3 PB 
PARAMS 


FF8124E4 
> exit 


3 VMB 


BOOT 


Exiting. . . 






Task Name? 























































14328 


14328 





61 


61 



Stopping DUP server . . . 

>» 

>»set host /dup/dssi params 

Starting DUP server. . . 

DSSI Node (SUSAN) 

Copyright 1988 Digital Equipment Corporation 



PARAMS> show node 
Parameter Current 



Default 



Type 



Radix 



NODENAME 



SUSAN 



PARAMS> show allclass 
Parameter Current 



RF30 
Default 



String Ascii B 

Type Radix 
Byte Dec B 



ALLCLASS 

PARAMS> exit 
Exiting . . . 



6—44 Maintenance Mode Firmware 



Stopping DUP server. . . 

>» 

>»set host /maint/uqssp 200014 68 

UQSSP Controller (772150) 

Enter SET, CLEAR, SHOW, HELP, EXIT, or QUIT 
Node CSR Address Model 



772150 


21 


1 760334 


21 


4 760340 


21 


5 760344 


21 


7 KFQSA — 




? help 




Commands : 




SET <node> /KFQSA 




SET <NODE> <CSR address> <model> 


CLEAR <NODE> 




SHOW 




HELP 




EXIT 




QUIT 




Parameters: 




<N0DE> 




<CSR_address> 




<model> 




? set 6 /kfqsa 




? show 




Node CSR Address 1 


tfodel 


772150 


21 


1 760334 


21 


4 760340 


21 


5 760344 


21 


6 KFQSA — 




? exit 




Programming the KFQSA 




>» 




>»set language 5 




>» 




6.2.7.16 SHOW 




Format : 





set KFQSA DSSI node number 
enable a DSSI device 
disable a DSSI device 
show current configuration 
print this text 
program the KFQSA 
don't program the KFQSA 

to 7 

760010 to 777774 

21 (disk) or 22 (tape) 



SHOW {parameter} 

Description : 

Displays the console parameter indicated. 



Maintenance Mode Firmware 6-45 

Parameters : 

• BFL(A)G — Show the default R5 boot flags. 

• BOOT — Show the default boot device. 

• DEVICE. — Show a list of all devices in the system. 

• ETHERNET — Show the hardware Ethernet address for all 
Ethernet adapters that can be found. Displays as blank, if no 
Ethernet adapter is present. 

• DSSI — Show the status of all nodes that can be found on the DSSI 
bus. For each node on the DSSI bus, the console displays the node 
number, the node name, and the boot name and type of the device, if 
available. The command does not include the bootability of the device. 
The node that issues the command reports a node name of "*". The 
device information is obtained from the media type field of the MSCP 
command GET UNIT STATUS. In the case where the node is not 
running, or is not capable of running an MSCP server, then no device 
information is displayed. 

• LANGUAGE — Show the console language and keyboard type. 
Refer to the corresponding SET LANGUAGE command for the 
meaning. 

• MEMORY — Show main memory configuration on a board by 
board basis. Also report the addresses of bad pages, as denned by the 
bitmap. 

/FULL Additionally show the normally inaccessible areas of 
memory, such as, the PFN bitmap pages, the console scratch 
memory pages, and the Q22-bus scatter/gather map pages. 

• QBUS — Show all Q22-bus I/O addresses that respond to an aligned 
word read. For each address, the console displays the address in the 
VAX I/O space in hex, the address as it would appear in the Q22-bus 
I/O space in octal, and the word data that was read in hex. This 
command may t ake several minutes to complete, so the user may 
want to issue a |Otrl| [<5| to terminate the command. The command 
disables the scatter/gather map for the duration of the command. 

• UQSSP — Show the status of all disks and tapes that can be found 
on the Q22-bus which support the UQSSP protocol. For each such 
disk or tape on the Q22-bus, the console displays the controller 
number, the controller CSR address, and the boot name and type 

of each device connected to the controller. The command does not 
indicate the bootability of the device. 



6—46 Maintenance Mode Firmware 



The device information is obtained from the media type field of the 
MSCP command GET UNIT STATUS. In the case where the node is 
not running, or is not capable of running, an MSCP server, then no 
device information is displayed. 

• VERSION — Show the current version of the firmware. 

Qualifiers : 

On a per parameter basis 
Arguments : 

None 
Examples : 

>» 

>» show bf lag 

00000220 

>» show boot 

DUA0 

»> 

>»show device 

DSSI Node (SUSAN) 

-DIA0 -rf(0,0,*) (RF71) 

DSSI Node 1 (KAREN) 
-DIA1 -rf(l,l,*) (RF71) 

DSSI Node 7 (*) 

UQSSP Tape Controller (772150) 
-MUA0 -tm(0,0) (TK70) 

Ethernet Adapter 

-ESA0 -se -mop() (08-00-2B-0C-C4-75) 

>» 

>» show dssi 

DSSI Node (SUSAN) 

-DIA0 -rf(0,0,*) (RF71) 

DSSI Node 1 (KAREN) 
-DIA1 -rf(l,l,*) (RF71) 



Maintenance Mode Firmware 6—47 



DSSI Node 7 (*) 

>» 

>»show ethernet 

Ethernet Adapter 

-ESAO -se -mop() (08-00-2B-0C-C4-75) 

>» 

>»show language 

English (United States/Canada) 

>» 

>»show memory 

Memory 0: 00000000 to 003FFFFF, 4MB, bad pages 

Total of 4MB, bad pages, 98 reserved pages 

>» 

>»show memory/ full 

Memory 0: 00000000 to 003FFFFF, 4MB, bad pages 

Total of 4MB, bad pages, 98 reserved pages 

Memory Bitmap 

-003F8000 to 003FFFFF, 2 pages 

Console Scratch Area 

-003F4000 to 003F7FFF, 32 pages 

Qbus Map 

-003F8000 to 003FFFFF, 64 pages 

Scan of Bad Pages 

>» 

>»show qbus 

Scan of Qbus I/O Space 

-200014 68 (772150) - 4000 (154) RQDX3/KDA50/RRD50/RQC25/X-DISK 

-2000146A (772152) = 0B40 

-20001940 (774500) = 0000 (260) TQK50/TQK70/TU81E/RV20/X-TAPE 

-20001942 (774502) = 0BC0 

-20001F40 (777500) = 0020 (004) IPCR 

Scan of Qbus Memory Space 

>» 

>»show uqssp 

UQSSP Tape Controller (772150) 

-MUA0 -tm(0,0) (TK70) 

>» 

>»show version 

KN210 — A Vn.n 

>» 



6-48 Maintenance Mode Firmware 

6.2.7.17 START 

Format : 

START [{address}] 

Description : 

The console starts instruction execution at the specified address. If no 
address is given, the current PC is used. If memory mapping is enabled, 
macro instructions are executed from virtual memory, and the address 
is treated as a virtual address. The START command is equivalent to a 
DEPOSIT to PC, followed by a CONTINUE. No INITIALIZE is performed. 

Qualifiers : 

None 

Arguments : 

• [{address}] — The address at which to begin execution. This is 
loaded in the user's PC. 

Examples : 

>»start 1000 

6.2.7.18 TEST 

Format : 

TEST [{test_number} [{test.argumexits}]] 

Description : 

The console invokes a diagnostic test program specified by the test 
number. If a test number of is specified, the power-up script is executed. 
The console accepts an optional list of up to five additional hexadecimal 
arguments. 

A more detailed explanation of the diagnostics may be found in 
Section 6.4. 

Qualifiers : 

None 



Maintenance Mode Firmware 6—49 



Arguments : 

• {testjnumber} — A two digit hexadecimal number specifying the 
test to be executed. 

• {test_arguments} — Up to five additional test arguments. These 
arguments are accepted but no meaning is attached to them by the 
console. For the interpretation of these arguments, consult the test 
specification for each individual test. 

Examples : 



»> 
>» 
>»t o 



! Execute the power-up diagnostic script 

! Warning. . .this has the same affect as a power-up! 



49. .48. .47. .46. .45. .44. .43. .42. .41. .40. .39. .38. .37. .36. .35. .34. . 
33. .32. .31. .30. .29. .28. .27. .26. .25. .24. .23. .22. .21. .20. .19. .18. . 
17. .16. .15. .14.. 13. .12. .11. .10. .09. .08. .07. .06. .05. .04. .03. . 



>» 
>» 
»> 

>»t 9e 

Test 

# Address 



! List all of the diagnostic tests. 



Name 



Parameters 



2004C000 
2004B200 
C6 2004D6DC 
C7 2004D79E 
34 2004D858 
33 2004D920 
32 2004D968 
2004DA8C 
2004DB1C 
2004DB9E 
2004E1C5 
2004E512 
2004E7D8 
55 2004E983 
5A 2004E9F8 

45 2004EB08 

46 2004EDF0 
9E 2004F41A 

2004F440 
2004F602 
2004F7DD 
2004F9A4 
2004FB20 



91 
90 
80 
60 
52 
53 



81 
82 
CI 
C2 
C5 



De_SCB 
CP_SCB 
S S C_po we r up 
CBTCR timeout 
ROM logic test 
CMCTL_jpo we rup 
CMCTL regs 
CQB I C_powe rup 
CQBIC regs 
CQBIC_memory 
Console serial 
Prog timer 
TOY clock 
Interval timer 
VAX CMCTL CDAL 
cache_mem_cqbi c 
Cache l_diag_md 
List diags 
MSCP-QBDS test 
DELQA 
SSC RAM 
SSC RAM ALL 
SSC regs 



********* 
*** 



MEMCSR0_addr ********* 

** 

* 

********** 

start_baud end_baud ****** 

which_timer wait_time_us *** 

repeat_test_250ms_ea Tolerance *** 

* 

dont_report_memory_bad repeat_count 
start_addr end_addr addr_incr **** 
addr incr ********* 

* ~~ 

IP csr ****** 

de vi ce_num_addr * * * * 

* 



6-50 Maintenance Mode Firmware 



56 


2004FC14 


5C 


2004FF19 


5D 


20050COC 


58 


200523D2 


57 


200527B8 


5E 


200527CD 


5B 


20052BF6 


5F 


20052DC4 


54 


20053967 


41 


20053C3C 


42 


20053DDD 


31 


20053E20 


30 


2005434F 


4F 


2005478A 


4E 


20054948 


4D 


20054A5D 


4C 


20054BEF 


4B 


2O055OB0 


4A 


2005528A 


49 


2005549D 


48 


20055A6C 


47 


200560C3 


40 


2005624E 


44 


20056568 


9D 


200568B4 


9C 


200569B8 


9F 


200571CD 


70 


200578F0 


71 


20057907 


72 


2005791C 


73 


20057931 


74 


2005794B 


75 


20057965 


76 


2005797F 


77 


20057999 


>» 




>» 




>» 




>»t fe 



S I I_ext_loopbck 

SII_initiatior 

SI I target 

DSSI reset 

SII_memory 

NI_memory 

SII__registers 

NI_Test 

Virtual mode 

Board Reset 

Check_for_intrs 

MEM_Setup_CSRs 

MEM_Bitmap 

MEM_Data 

MEM_Byte 

MEM_Address 

MEM_ECC_Error 

MEM_Maskd_Errs 

MEM_Correction 

MEM_FDM_Logi c 

MEM_Addr_shrts 

MEM_Re fresh 

MEM_Count_Errs 

Cache_memory 

Utilities 

List CPU regs 

Create script 

R3000_cache 

R3000_fpu 

R3000_tlb 

R3000_reg_intrf 

R3000_buf_intrf 

R3 0_mem_intr f 

R3000_interrupt 

R3000 mov inver 



** * 

run test ****** 

run test ******* 

port_no time_secs * 

incr test_pattern run_test ******* 

incr test_pattern run_test ******* 

run_test **** 

do_extl where run_test ******* 

********* 

*** 

*** 

********** 

*** mark_Hard_SBEs ****** 

start_add end_add add_incr cont_on_err ***** 

start_add end_add add_incr cont_on_err ***** 

start_add end_add add_incr cont_on_err ***** 

start_add end_add add_incr cont_on_err ***** 

start_add end_add add_incr cont_on_err ***** 

start_add end_add add_incr cont_on_err ***** 

*** cont on err ****** 

start_add end_add * cont_on_err pat 2 pat3 ** 

start end incr cont_on_err time_seconds **** 

First_board Last_board Soft_errs_allowed *** 

addr incr ********* 

Expnd_err_msg get_mode init_LEDs clr_ps_cnt 



loop run_test *** 

incr pattern start_add end_add run_test ** 

incr pattern start_add end_add ** 

run_test 

incr * start add end add ** 



! Show the diagnostic state. 



Maintenance Mode Firmware 6—51 



bitmap=OOBF3400, length=OCOO, checksum=007E 

busmap=0 OBF 8 

return_stack=201406A4 

subtest_pc=2004EBB0 

timeout=00000001, error=00, de_error=00 

de_error_vector=00, sever it y_code=02, total_error_count=0000 

previous_error=00000000, 00000000, 00000000, 00000000, 00000000 

last_exception_pc=2004EBDA 

flags=21FFFD7F, test_flags=20 

highest_severity=00 

led_display=0 6 

console_display=00 

save_mchk_code=80 , save_err_f lags=000000 

parameter_l=00000000 2=00000000 3=00000000 

parameter 6=00000001 7=00000000 8=2004EBE0 



4=00000000 5=00000000 
9=00000000 10=20056056 



>» 
>» 
>» 

>»t 9c 

TOY =76BA1D75 
TCRO =00000000 
TCR1 =00000001 
RXCS =00000000 
MSER =00000000 
BDR =FFFFFFD0 
SCR =0000C000 
QBMBR=00000000 



! Display the CPU registers, 



ICCS =00000000 
TIRO =00000000 
TIR1 =02BD7971 
RXDB 
CADR 

DLEDR=0000000C 
DSER =00000080 
IPCRn=0020 



TNIR0=00000000 TIVR0=00000078 

TNIR1=0000000F TIVR1=0000007C 

0000000D TXCS =00000000 TXDB =00000030 

0000000C 

SSCCR=00D45033 CBTCR=C0000004 

QBEAR=00O0OO0F DEAR =00000000 



MEM_FRU 1 
MEM_FRD 2 
MEM_FRD 3 
MEM FRD 4 



MEMCSR_0=80000015 
MEMCSR_4=80400016 
MEMCSR__8=00000000 
MEMCSR12=00000000 
MEMCSR16=00000044 



1=00000015 

5=80800016 

9=00000000 

13=00000000 

17=0000203C 



2=00000015 

6=00000016 

10=00000000 

14=00000000 



3=00000015 

7=00000016 

11=00000000 

15=00000000 



Ethernet SA = 08-00-2B-0B-25-65 



NICSR0=0004 



SII 



>» 



MSIDRO =01FF 
MSIIDR =8007 
MSIDSCR=80FF 



MSIDR1 =0002 
MSITR =0000 
MSIDSSR=8500 



MSIDR2 =0000 
MSITLP =0000 
MSIDCR =0008 



MSICSR =0010 
MSIILP =0000 



6—52 Maintenance Mode Firmware 

6.2.7.19 UN JAM 

Format : 

UNJAM 

Description : 

An I/O bus reset is performed. This is implemented by writing 1 to IPR 
55. 

Qualifiers : 

None 
Arguments : 

None 
Examples : 

>»un jam 
»> 

6.2.7.20 X - Binary Load and Unload 

Format : 

X {address} {count} <CR> {line_checksum} 
{data} {data_checksum} 

Description : 

The X command is for use by automatic systems communicating with the 
console. It is not intended for use by operators. 

The console loads or unloads (that is, writes to memory, or reads from 
memory) the specified number of data bytes, starting at the specified 
address through the console serial line. 

If bit 31 of the count is clear, data is to be received by the console, and 
deposited into memory. If bit 31 of the count is set, data is to be read from 
memory and sent by the console. The remaining bits in the count are a 
positive number indicating the number of bytes to load or unload. 



Maintenance Mode Firmware 6—53 



The console accepts the command upon receiving the carriage return. 
The next byte the console receives is the command checksum, which is 
not echoed. The command checksum is verified by adding all command 
characters, including the checksum and separating whitespace, (but 
not including the terminating carriage return or rubouts or characters 
deleted by rubout), into an 8 bit register initially set to zero. If no errors 
occur, the result is zero. If the command checksum is correct, the console 
responds with the input prompt and either sends data to the requester or 
prepares to receive data. If the command checksum is in error, the console 
responds with an error message. The intent is to prevent inadvertent 
operator entry into a mode where the console is accepting characters from 
the keyboard as data, with no escape mechanism possible. 

If the command is a load (bit 31 of the count is clear), the console responds 
with the input prompt, then accepts the specified number of bytes of 
data for depositing to memory, and an additional byte of received data 
checksum. The data is verified by adding all data characters and the 
checksum character into an 8 bit register initially set to zero. If the final 
contents of the register is non-zero, the data or checksum are in error, and 
the console responds with an error message. 

If the command is a binary unload (bit 31 of the count is set), the console 
responds with the input prompt, followed by the specified number of bytes 
of binary data. As each byte is sent, it is added to a checksum register 
initially set to zero. At the end of the transmission, the 2's complement of 
the low byte of the register is sent. 

If the data checksum is incorrect on a load, or if memory errors or line 
errors occur during the transmission of data, the entire transmission is 
completed, and then the console issues an error message. If an error 
occurs during loading, the contents of the memory being loaded are 
UNPREDICTABLE. 

Echo is suppressed during the receiving of the data string and checksums. 

To avoid treating flow control characters from the terminal as valid 
command line checksums, all flow control is terminated at the reception 
of the carriage return terminating the command line. 

It is possible to co ntrol th e con sol e ser ial line through the use of the 
control characters ( |Ctrl| [c|, [Ori] §, [Ctrl) |o| and so on) during a binary 
unload. It is not possible during a binary load, as all received characters 
are valid binary data. 



6-54 Maintenance Mode Firmware 



Data being loaded with a binary load command must be received by the 
console at a rate of at least one byte every 60 seconds. The command 
checksum that precedes the data must be received by the console within 
60 seconds of the carriage return that terminates the command line. The 
data checksum must be received within 60 seconds of the last data byte. 
If any of these timing requirements are not met, the console aborts the 
transmission by issuing an error message and prompting for input. 

The entire command, including the checksum, can be sent to the console 
as a single burst of characters at the console serial line's specified 
character rate. The console is able to receive at least 4 Kbytes of data 
in a single X command. 

Qualifiers : 

None 
Arguments : 

None 
Examples : 

None 

6.2.7.21 ! - Comment 

Format : 



Description : 

The comment command is used to document command sequences. The 
comment character can appear anywhere on the command line. All 
characters following the comment character are ignored. 

Qualifiers : 

None 
Arguments : 

None 
Examples : 

>» ! The console ignores this line . 
>» 



Maintenance Mode Firmware 6—55 



6.2.8 Conventions for Tables 6-5 and 6-6 

Table 6-5 lists a complete summary of the console commands. Table 6-6 
is a summary of the qualifiers recognized by the diagnostic processor 
console. 

UPPERCASE denotes the command or qualifier keyword. 

{} denotes a mandatory item which must be syntactically correct. 

[ ] denotes an optional item. 

! denotes an "or" condition. 

boot_flags, count, size, address, & parameters denote hex longword 
values. 

bootjdevice denotes a legal boot device name. 

csrjaddress denotes a Q22-bus I/O page CSR address. 

controller _number denotes a controller number from to 255. 

languagejype denotes the language value, from 1 to 15. 

command denotes a console command other than REPEAT. 

data, pattern, & mask denote hex values of the current size. 

test_number denotes hex byte test number. 



Table &-5 


Console Command Summary 






Command 


Qualifiers 


Argument 


Other(s) 


BOOT 


/R5:{boot_fiags} /{boot_flags} 


[{boot_device}] 


— 


CONTINUE 


— 


— 


— 


DEPOSIT 


/B/W/L/Q — /G/I/V/P/M 


{address} 


{data} 




/U 




[{data}] 




/N:{count} /STEP:{size} 








/WRONG 






EXAMINE 


/B/W/L/Q — /G/I/V/P/M 

/U 

/N:{count} /STEP:{size} 

/WRONG 

/INSTRUCTION 


[{address}] 




EXIT 


— 


— 


— 


FIND 


/MEM/RPB 









6—56 Maintenance Mode Firmware 



Table 6-5 (Cont.) Console Command Summary 



Command 


Qualifiers 


Argument 


Other(s) 


HALT 


— 








HELP 


— 


— 


— 


INITIALIZE 


— 


— 


— 


MOVE 


/B/W/L/Q— /V/P/U 


{src_address} 


{dest_ 




/N:{count} /STEP:{size} 




address} 




/WRONG 






NEXT 


— 


[{count}] 


— 


REPEAT 


_ — 


{command} 


— 


SEARCH 


/B/W/L/Q— /V/P/U 


{start_address} 


{pattern} 




/N:{count} /STEP:{size} 




[{mask}] 




/WRONG 








/NOT 






SET 


— 


{bitmap} 


— 


BFL(A)G 








SET BOOT 


— 


{device_string} 


— 


SET HOST 


/DUP /DSSI 


{node_number} 


[{task}] 


SET HOST 


/DUP /UQSSP {/DISK ! 


{controller. 


[{task}] 




/TAPE} 


number} 


[{task}] 




/DUP /UQSSP 


{csr.address} 




SET HOST 


/MAINTENANCE /UQSSP 


{controller. 






/SERVICE 


number} 






/MAINTENANCE /UQSSP 


{csr.address} 




SET 


— 


{language_type} 


— 


LANGUAGE 








SHOW 


— 


— 


— 


BFL(A)G 








SHOW 


— 


— 


— 


BOOT 








SHOW DSSI 


— 


— 


— 


SHOW 


— 


— 


— 


ETHERNET 








SHOW 


— 


— 


— 


LANGUAGE 








SHOW 


/FULL 


— 


— 


MEMORY 








SHOW 


— 


— 


— 


QBUS 









Maintenance Mode Firmware 6—57 



Table 6-5 (Cont.) Console Command Summary 



Command 



Qualifiers 



Argument 



Other(s) 



SHOW 

UQSSP 

SHOW 

VERSION 

START 

TEST 

UNJAM 

X 



{address} 
{test_number} 

{address} 



[{parameters}] 
{count} 



Table 6-6 Console Qualifier Summary 



Data Control 



/B Byte, legal for memory references only. 

/W Word, legal for memory references only. 

/L Longword, the default for GPR and IPR references. 

/Q Quadword, legal for memory references only. 

/N:{count} Specify number of additional operations. 

/STEP:{size} Override the default step incrementing size with the value 

specified for the current reference. 

/WRONG Ignore ECC bits on reads. Use an ECC value of 3 on writes. 



Address Space Control 



/G 

/I 

/V 

/P 

/U 

/M 



General Purpose Registers 

Internal Processor Registers 

Virtual memory 

Physical memory, both VAX memory and I/O spaces 

Protected memory (ROMs, SSC RAM, PFN bitmap) 

Machine state (PSL) 



6—58 Maintenance Mode Firmware 



Table 6-6 (Cont.) Console Qualifier Summary 



Command Specific 



/INSTRUCTION EXAMINE command only. Disassemble the instruction at 

address specified. 
/NOT SEARCH command only. Invert the sense of the match. 

/R5:{boot_nags}, BOOT command only. Specify a function bitmap to pass to 
/{boot_flags} VMB through R5. Refer to Figure 6-1 for a bit description of 

R5. Either form of the command is acceptable. 
/RPB, /MEM FIND command only. Search for valid RPB or good block of 

memory. 
/DUP, SET HOST command only. Refer to command description for 

/DSSI, /UQSSP, usage. 



/DISK, /TAPE, 
/MAINTENANCE, 

/SERVICE 



6.3 Bootstrapping 

Bootstrapping is the process of loading and transferring control to an 
operating system. The KN210 maintenance mode supports bootstrap 
MDM diagnostics and any user application image which conforms to the 
boot formats described herein. 

On the KN210, a bootstrap occurs whenever a BOOT command is issued 
at the console or whenever the processor halts and the conditions specified 
in the Table 6-1 for automatic bootstrap are satisfied. 

6.3.1 Boot Devices 

The maintenance mode firmware passes the address of a descriptor of 
the boot device name to VMB through RO. The device name used for the 
bootstrap operation is one of the following: 

• ESAO, if no default boot device has been specified 

• The default boot device specified at initial power-up or through a SET 
BOOT command 

• The boot device name explicitly specified in a BOOT command line 



Maintenance Mode Firmware 6—59 



The device name may be any arbitrary character string, with a maximum 
length of 17 characters. Longer strings cause an error message to be 
issued to the console. Otherwise the console makes no attempt at 
interpreting or validating the device name. The console converts the 
string to all upper case, and passes VMB the address of a string descriptor 
for the device name in RO. 

Table 6-7 correlates the boot device names expected in a BOOT command 
with the corresponding supported devices. 



Table 6-7 KN210 Supported Boot Devices 



Boot 


Controller 




Name 1 


Type 


Device Type(s) 


Disk: 


[node$]DIAn 


On-board 
DSSI 


RF30, RF71 


DUcn 


RQDX3 
MSCP 


RD52, RD53, RD54, RX33, RX50 




KDA50 MSCP 


RA70, RA80, RA81, RA82, RA90 




KFQSA 


RF30, RF71 




MSCP 






KLESI 


RC25 


Tape: 


[node$]MIAn 


On-board 
DSSI 


TF70 


MUcn 


TQK50 MSCP 


TK50 




TQK70 MSCP 


TK70 




KFQSA 


TFxx 




MSCP 






KLESI 


TU81E 


Network: 


ESAO 


On-board 

Enet 






1 Boot device names consist of minimally a two letter device code, followed by a single 
character controller letter (A..Z), and terminating in a device unit number (0...65535). 
DSSI device names may optionally include a node prefix, consisting of either a node 
number (0...7) or a node name (a string of up to 8 characters), terminating in a "$". 



6-60 Maintenance Mode Firmware 



Table 6-7 (Cont.) KN210 Supported Boot Devices 

Boot Controller 

Name 1 Type Device Type(s) 

Network: 

XQcn DEQNA 

DELQA 

DESQA 



PROM: 

PRAO MRV11 

1 Boot device names consist of minimally a two letter device code, followed by a single 
character controller letter (A...Z), and terminating in a device unit number (0...65535). 
DSSI device names may optionally include a node prefix, consisting of either a node 
number (0...7) or a node name (a string of up to 8 characters), terminating in a "$". 



NOTE 

Table 6-7 presents a definitive list of boot devices which the 
KN210 supports. However, the KN210 will likely boot other 
devices which adhere to the MSCP standards. 

6.3.2 Boot Flags 

The action of VMB is qualified by the value passed to it in R5. R5 
contains boot flags that specify conditions of the bootstrap. The firmware 
passes to VMB either the R5 value specified in the BOOT command or the 
default boot flag value specified with a SET BFLAG command. 

Figure 6-1 shows the location of the boot flags used by VMB in the boot 
flag longword and Table 6-8 describes each flag's function. 



RPB$V TOPSYS 



Maintenance Mode Firmware 6—61 



31 28 




9 


8 




6 


S 


4 


3 






























RPB$V_HALT — 
RPB$V_SOLICT - 
RPB$V_HEADER 
RPB$V_BOOBPT 
RPB$V_DIAG — 
RPB$V_BBLOCK 
RPB$V_CONV — 



Figure 6-1 VMB Boot Flags 



MA-XD0464S 



Table 6-8 VMB Boot Flags 



Field Name 



Description 



RPB$V_CONV 

3 RPB$V_ 

BBLOCK 



RPB$V_DIAG 



RPB$V_ 
BOOBPT 

RPB$V_ 
HEADER 



RPB$V_SOLICT 



Conversational bootstrap. 

Secondary bootstrap from bootblock. When this bit 
is set, VMB reads logical block number of the 
boot device and tests it for conformance with the 
bootblock format. If in conformance, the block is 
executed to continue the bootstrap. No attempt to 
perform a Files-11 bootstrap is made. 
Diagnostic bootstrap. When this bit is set, 
the load image requested over the network is 
[SYS0.SYSMAINT3DIAGBOOT.EXE. 
Bootstrap breakpoint. If this flag is set, a 
breakpoint instruction is executed in VMB and 
control is transferred to XDELTA prior to boot. 
Image header. If this bit is set, VMB transfers 
control to the address specified by the file's image 
header. If this bit is not set, VMB transfers control 
to the first location of the load image. 
File name solicit. When this bit is set, VMB 
prompts the operator for the name of the application 
image file. A maximum of a 39 character file 
specification is permitted. 



6-62 Maintenance Mode Firmware 



Table 6-8 (Cont.) VMB Boot Flags 



Field Name Description 



9 RPB$V_HALT Halt before transfer. When this bit is set, VMB 

halts before transferring control to the application 
image. 

31:28 RPB$V_ This field can be any value from through F. This 

TOPSYS flag changes the top level directory name for the 

system disks with multiple operating systems. For 
example, if TOPSYS is 1, the top level directory 
name is [SYS1..J. 



6.3.3 Preparing for the Bootstrap 

Prior to dispatching to the primary bootstrap (VMB), the firmware 
initializes the system to a known state. The initialization sequence is 
the following: 

1. Check CPMBX<2>(BIP). If it is set, bootstrap fails. 

2. If this is an automatic bootstrap, print the message "Loading system 
software" on the console terminal. 

3. Validate the boot device name. If none exists, supply a list of available 
devices and prompt user for a device. If no device is entered within 30 
seconds, use ESAO. 

4. Write a form of this BOOT request including the active boot flags and 
boot device on the console, for example "(BOOT7R5:0 DUAO)". 

5. Set CPMBX<2>(BIP). 

6. Initialize the Q22-bus scatter/gather map. 

a. Clear IPCR<5>(LMEAE). 

b. Perform an UNJAM. 

c. Map all vacant Q22-bus pages to the corresponding page in local 
memory and validate each entry if that page is good. 

d. Perform an INIT. 

e. Set IPCR<5>(LMEAE). 

7. Validate the PFN bitmap. If invalid, rebuild it. 

8. Search for a 128 Kbyte contiguous block of good memory as defined by 
the PFN bitmap. If 128 Kbytes cannot be found, the bootstrap fails. 



Maintenance Mode Firmware 6-63 



9. Initialize the general purpose registers. 

RO = address of descriptor of the boot device name or if none 

specified 

R2 = length of PFN bitmap in bytes 

R3 = address of PFN bitmap 

R4 = time of day from PR$_TODR at power-up 

R5 = boot flags 

RIO = halt PC value 

Rll = halt PSL value (without halt code and map enable) 

AP = halt code 

SP = base of 128 Kbyte good memory block + 512 

PC = base of 128 Kbyte good memory block + 512 

Rl, R6, R7, R8, R9, FP =0 

10. Copy the VMB image from EPROM to local memory beginning at the 
base of the 128 Kbyte good memory block + 512. 

11. Exit from the firmware to memory resident VMB. 

On entry to VMB the processor is running at IPL 31 on the interrupt 
stack with memory management disabled. 

6.3.4 Primary Bootstrap, VMB 

"Virtual memory boot (VMB) is the primary bootstrap for booting VAX 
processors. On the KN210, VMB is resident in the firmware and is copied 
into main memory before control is transferred to it. VMB then loads the 
secondary bootstrap image and transfers control to it. 

NOTE 

In certain cases, VMB actually loads the operating system directly. 
However, for the purpose of this discussion "secondary bootstrap*' 
refers to any VMB loadable image. 

VMB inherits a well defined environment and is responsible for further 
initialization. The following summarizes the operation of VMB: 

1. Initialize a two page SCB on the first page boundary above VMB. 

2. Allocate a three page stack above the SCB. 

3. Initialize the restart parameter block (RPB). 

4. Initialize the secondary bootstrap argument list. 

5. If not a PROM boot, locate a minimum of 3 consecutive valid QMRs. 



6—64 Maintenance Mode Firmware 



6. Write "2" to the diagnostic LEDs and display "2.." on the console to 
indicate that VMB is searching for the device. 

7. Optionally, solicit from the console a "Bootfile: " name. 

8. Write the name of the boot device from which VMB will attempt to 
boot on the console, for example, "-DUA0". 

9. Copy the secondary bootstrap from the boot device into local memory 
above the stack. If this fails, the bootstrap fails. 

10. Clear CPMBX<2>(BIP) and CPMBX<3>(RIP). 

11. Write "0" to the diagnostic LEDs and display "0.." on the console to 
indicate that VMB is now transferring control to the loaded image. 

12. Transfer control to the loaded image with the following register 
usage: 

R5 = transfer address in secondary bootstrap image 
RIO = base address of secondary bootstrap memory 
Rll = base address of RPB 

AP = base address of secondary boot parameter block 
SP = current stack pointer 

If the bootstrap operation fails, VMB relinquishes control to the console 
by halting with a HALT instruction. 

NOTE 

VMB makes no assumptions about the location of Q22-bus 
memory. However, VMB searches through the Q22-bus map 
registers (QMRs) for the first QMR marked valid. VMB requires 
minimally 3 and maximally 129 contiguous valid maps to complete 
a bootstrap operation. If the search exhausts all map registers 
or there are fewer than the required number of valid maps, a 
bootstrap cannot be performed. It is recommended that a suitable 
block of Q22-bus memory address space be available (unmapped 
to other devices) for proper operation. 

The following is a sample console display of a successful automatic 
bootstrap: 

Loading system software . 
(BOOT/R5:0 DUAO) 

2. . 

-DUAO 
1. .0. . 



Maintenance Mode Firmware 6—65 



After a successful bootstrap operation, control is passed to the secondary 
bootstrap image with the memory layout as shown in Figure 6-2. 



1 1 
• . 




• POTENTIAL "BAD" MEMORY • 


• • 


BASE 


RPB 






BASE+512(SP) 










VMB IMAGE 


256 PAGES FOR VMB 


NEXT PAGE 




128 Kbyte BLOCK OF 


SCB (TWO PAGES) 


(PAGE ALIGNED) 


NEXT PAG E+ 1024 


STACK {THREE PAGES) 






NEXT PAGE+2560 


SECONDARY BOOTSTRAP IMAGE 








(POTENTIALLY EXCEEDS BLOCK) 


•^ 




• • 


• UNUSED MEMORY • 


• • 


PFN BITMAP 




~~ | 




PFN BITMAP 

(ON A PAGE BOUNDARY) 


UP TO 32 PAGES 




FIRMWARE "SCRATCH MEMORY" 








(BALANCE BETWEEN BITMAP & QMRs) 






QMR BASE 










Q22-bus SCATTER/GATHER MAP 


64 PAGES 

I 




(ALWAYS ON 32 Kbyte BOUNDARY) 


• • 


i 


» POTENTIAL "BAD" MEMORY • 


TOP OF MEMORY 


» 1 


1 





Figure 6-2 Memory Layout at VMB Exit 

In the event that an operating system has an extraordinarily large 
secondary bootstrap which overflows the 128 Kbytes of good memory, 
VMB loads the remainder of the image in memory above the good block. 
However, if there are not enough contiguous good pages above the block to 
load the remainder of the image, the bootstrap fails. 



6-66 Maintenance Mode Firmware 



6.3.5 Device Dependent Bootstrap Procedures 

As mentioned earlier, the KN210 supports bootstrapping from a variety of 
boot devices. The following sections describe the various device dependent 
boot procedures. 

6.3.5.1 Disk and Tape Bootstrap Procedure 

The disk and tape bootstrap supports Files- 11 lookup (supporting only 
the ODS level 2 file structure) or the boot block mechanism (used in 
PROM boot also). Of the standard DEC operating systems VMS and ELN 
use the Files- 11 bootstrap procedure and Ultrix-32 uses the boot block 
mechanism. 

VMB first attempts a Files- 11 lookup, unless the RPB$V_BBLOCK boot 
flag is set. If VMB determines that the designated boot disk is a Files- 11 
volume, it searches the volume for the designated boot program, usually 
[SYS0.SYSEXE3SYSBOOT.EXE. However, VMB can request a diagnostic 
image or prompt the user for an alternate file specification (Section 6.3.2). 
If the boot image cannot be found, VMB fails. 

If the volume is not a Files- 11 volume or the RPB$V_BBLOCK boot flag 
was set, the boot block mechanism proceeds as follows: 

1. Read logical block of the selected boot device (this is the boot block). 

2. Validate that the contents of the boot block conform to the boot block 
format (Figure 6-3). 

3. Use the boot block to find and read in the secondary bootstrap. 

4. Transfer control to the secondary bootstrap image, just as for a Files- 
11 boot. 

The format of the boot block must conform to that shown in Figure 6-3. 



Maintenance Mode Firmware 6-67 



BB+O: 



31 


24 


23 




16 


15 







1 


N 


ANY VALUE 


LOW LBN 


HIGH LBN 



(THE NEXT SEGMENT IS ALSO USED AS A PROM "SIGNATURE BLOCK.") 



31 24 23 



16 15 



BB+ (2*n)+0: 

BB+ (2*n)+8: 
BB+ <2*n)+12: 
BB+(2*n)+16: 
BB+ (2*n)+20: 



CHK 



18 (HEX) 



ANY VALUE, MOST LIKELY 



SIZE IN BLOCKS OF THE IMAGE 



LOAD OFFSET 



OFFSET INTO IMAGE TO START 



SUM OF THE PREVIOUS THREE LONGWORDS 



WHERE: 



(1) THE 18(HEX) INDICATES THIS IS A VAX INSTRUCTION SET 

(2) 18 (HEX) + K = THE ONE'S COMPLEMENT OF CHK 



Figure 6-3 Boot Block Format 

6.3,5.2 PROM Bootstrap Procedure 

The PROM bootstrap uses a variant of the boot block mechanism. VMB 
searches through Q22-bus memory on 16 Kbyte boundaries for a valid 
PROM signature block, the second segment of the boot block denned in 
Figure 6-3. 

At each boundary, VMB : 

1. "Validates the readibility of that Q22-bus memory page. 

2. If readable, check to see if it contains a valid PROM signature block. 

If verification passes, the PROM image will be copied into main memory 
and VMB will transfer control to that image at the offset specified in the 
PROM bootblock. If not, the next page will be tested. 



6-68 Maintenance Mode Firmware 



NOTE 

It is not necessary that the boot image actually reside in PROM. 
Any boot image in Q22-bus memory space with a valid signature 
block on a 16 Kbyte boundary is a candidate. 

The PROM image is copied into main memory in 127 page "chunks" until 
the entire PROM is moved. All destination pages beyond the primary 128 
Kbyte block are verified to make sure they are marked good in the PFN 
bitmap. The PROM must be copied contiguously and if all required pages 
cannot fit into the memory immediately following the VMB image, the 
boot fails. 

6.3.5.3 Network Bootstrap Procedure 

Whenever a network bootstrap is selected on a KN210, VMB makes 
continuous attempts to boot from the network. VMB uses the DNA 
maintenance operations protocol (MOP) as the transport protocol for 
network bootstraps and other network operations. Once a network boot 
has been invoked, VMB turns on the designated network link and repeats 
load attemps, until either a successful boot occurs or it is halted from the 
operator console. 

The KN210 supports the load of a standard operating system, a diagnostic 
image, or a user designated program through network bootstraps. The 
default image is a standard operating system. However, a user may select 
an alternate image by setting either the RPB$V_DIAG bit or the RPB$V_ 
SOLICT bit in the boot flag longword R5. Note, that the RPB$V_SOLICT 
bit has precedence over the RPB$V_DIAG bit. Hence, if both bits are set, 
then the solicited file is requested. (Refer to Figure 6—1 for the usage of 
these bits.) 

NOTE 

VMB accepts a maximum of a 39 character file specification 
for solicited boots. If the network server is running VMS, the 
following defaults apply to the file specification: the directory 
MOM$LOAD:, and an extension .SYS. Therefore, the 39 character 
file specification need only consist of the filename if the default 
directory and extension attributes are used. 

The KN210 VMB uses the MOP program load sequence for bootstrapping 
the module and the MOP "dump/load" protocol type for load related 
message exchanges. The MOP message types used in the exchange are 
listed in Table 6-9. 



Maintenance Mode Firmware 6-69 



VMB, the requester, starts by sending a REQ_PROGRAM message in the 
appropriate envelope to the MOP "dump/load" multicast address. It then 
waits for a response in the form of a VOLUNTEER message from another 
node on the network, the MOP load server. If a response is received, 
then the destination address is changed from the multicast address to 
the node address of the server. The same REQ_PROGRAM message is 
retransmitted to the server as an acknowledge which initiates the load. 

Next, VMB begins sending REQ_MEM_LOAD messages in response to 
either: 

• MEM_LOAD message, while there is still more to load 

• MEM_LOAD_w_XFER, if it is the end of the image 

• PARAM_LOAD_w_XFER, if it is the end of the image and operating 
system parameters are required 

The "load number" field in the load messages is used to synchronize the 
load sequence. At the beginning of the exchange, both the requester and 
server initialize the load number. The requester only increments the load 
number if a load packet has been successfully received and loaded. This 
forms the acknowledge to each exchange. The server will resend a packet 
with a specific load number, until it sees a request with the load number 
incremented. The final acknowledge is sent by the requester and has a 
load number equivalent to the load number of the appropriate LOAD_w_ 
XFER message + 1. 

During the boot sequence if no response is made to the REQ_PROGRAM 
message in the current time-out limit, the time-out limit is increased 
linearly (by 4 seconds) up to a maximum of about 4 minutes. The initial 
time-out limit is 8 seconds. 

6.3.5.4 Network Listening 

While the KN210 is waiting for a load volunteer during bootstrap, it 
listens on the network for other maintenance messages directed to the 
node and periodically identifies itself at 8 to 12 minute intervals. In 
particular, this listener supplements the MOP functions of the VMB 
load requester typically found in bootstrap firmware and supports the 
following: 

• A remote console server that generates unsolicited SYSTEM_ID 
messages every 8 to 12 minutes and solicited SYSTEMJD messages 
in response to REQUESTJD messages, as well as, COUNTERS 
messages in response to REQ_COUNTERS messages. 



6—70 Maintenance Mode Firmware 



• A loopback server that responds to Ethernet LOOPBACK messages by 
echoing the message to the requester. 

• An IEEE 802.2 responder which replies to both XID and TEST 
messages. 

During network operation the firmware listens only to MOP "Load/Dump," 
MOP "Remote Console," and Ethernet "Loopback Assistance" messages 
protocols directed to the Ethernet physical address of the node. All other 
Ethernet protocols are filtered by the network device driver. Additionally, 
IEEE 802.3 messages are also processed by the network listener. 

The MOP functions and message types which are supported by the KN210 
are summarized in the following tables. 

Table 6-9 KN210 Network Maintenance Operations Summary 



Function 


Role 


Transmit 




Receive 


MOP Ethernet and IEEE 802.3 Messages 1 


Dump 


Requester 












Server 










Load 


Requester 


REQ_ 
PROGRAM 2 


to solicit 


VOLUNTEER 






REQ_MEM_ 


to solicit & 


MEM.LOAD 






LOAD 


ACK 
or 

or 


MEM_LOAD_w_ 
XFER 

PARAM_LOAD_ 
w XFER 



Server 



Console 



Requester 
Server 



SYSTEM ID 3 



in response 
to 



REQUESTED 



1 All unsolicited messages are sent in Ethernet (MOP V3) and IEEE 802.2 (MOP V4), until 
the MOP version of the server is known. All solicited messages are sent in the format used 
for the request. 

2 The initial REQ_PROGRAM message is sent to the dumpload multicast address. If an 
assistance VOLUNTEER message is received, then the responder's address is used as the 
destination to repeat the REQ_PROGRAM message and for all subsequent REQ_MEM_ 
LOAD messages. 

3 SYSTEM_ID messages are sent out every 8 to 12 minutes to the remote console multicast 
address and on receipt of a REQUEST_ID message they are sent to the initiator. 



Maintenance Mode Firmware 6—71 



Table 6-9 (Cont.) KN210 Network Maintenance Operations Summary 



Function 


Role 


Transmit 


Receive 


MOP Ethernet and IEEE 802.3 Messages 1 






COUNTERS 


in response REQ_ 
to COUNTERS 
BOOT 


Loopback 


Requester 










Server 


LOOPED 


in response LOOP_DATA 






DATA 4 


to 


IEEE 802.2 Messages 6 


Exchange 


Requester 








ID 










Server 


XIDJRSP 


in response XID_CMD 
to 


Test 


Requester 










Server 


TEST.RSP 


in response TEST_CMD 
to 



1 All unsolicited messages are sent in Ethernet (MOP V3) and IEEE 802.2 (MOP V4), until 
the MOP version of the server is known. All solicited messages are sent in the format used 
for the request. 

4 LOOPED_DATA messages are sent out in response to LOOP_DATA messages. These 
messages are actually in Ethernet LOOP TEST format, not in MOP format, and when sent 
in Ethernet frames omit the additional length field (padding is disabled). 
5 IEEE 802.2 support of XID and TEST is limited to Class 1 operations. 



6.4 Diagnostics 

The ROM based diagnostics constitute a major portion of the firmware 
on the KN210 and consist of an initial power-up test and a series of 
functional component diagnostics. These diagnostics run automatically 
on power-up and when in maintenance mode. They can be executed 
interactively as a whole, or as individual tests using the TEST command 
(Section 6.2.7.18). This section summarizes their operation. 



6—72 Maintenance Mode Firmware 



The purpose of the ROM based diagnostics is multifaceted: 

1. During powerup, they determine if enough of the KN210 is working to 
allow the console to run. 

2. During the manufacturing process, they verify that the board was 
correctly built. 

3. In the field, they verify that the board is operational, and to report all 
detected errors. 

4. They allow sophisticated users and Field Service technicians to run 
individual diagnostics interactively, with the intent of isolating errors 
to the FRU. 

To accommodate these requirements, the diagnostics have been designed 
as a collection of individual parameterized tests. A data structure, called 
a script, and a program, called the diagnostic executive, orchestrate the 
running of these tests in the right order with the right parameters. 

A script is a data structure that points to various tests. There are several 
scripts, one for the field, and several for manufacturing, depending on 
where on the manufacturing line the board is. Sophisticated users may 
also create their own scripts interactively. Additionally, the script contains 
other information: 

What parameters need to be passed to the test. 

What is to be displayed, if anything, on the console. 

What is to be displayed, if anything, on the LED. 

What to do on errors (halt, loop, or continue). 

Where the tests may be run from. For example, there are certain 
tests that can only be run from the EEROM. Other tests are position 
independent code (PIC), and may be run from EEROM, or main 
memory in the interests of execution speed. 

The diagnostic executive interprets scripts to determine what tests are 
to be run. There are several built-in scripts on the KN210 that are used 
for manufacturing, power-up, and Field Service personnel. The diagnostic 
executive automatically invokes the correct script based on the current 
environment of the KN210. Any script can be explicitly run with the 
TEST command from the console terminal. 

The diagnostic executive is also responsible for controlling the tests so 
that when errors occur, they can be caught and reported to the user. The 
executive also ensures that when the tests are run, the machine is left in 
a consistent and well denned state. 



Maintenance Mode Firmware 6—73 



6.4.1 Error Reporting 

Before a console is established, the only error reporting is through the 
KN210's diagnostic LEDs (and any LEDs on other boards). Once a console 
has been established, all errors detected by the diagnostics are also 
reported by the console. When possible, the diagnostics issue an error 
summary on the console. Example 6—4 shows a typical error display. 



?34 2 08 FF 00 0000 



P1=00000000 
P6=FFFFFFFF 
rO=00114B98 
r5=00000000 



P2=00000003 
P7=00000000 
rl=FFFFFFFF 
r6=AAAAAAAA 



P3=00000031 P4=00000011 P5=00002000 

P8=00000000 P9=00000000 P10=2005438F 

r2=2005D2F0 r3=55555555 r4=AAAAAAAA 

r7=00000000 r8=00000000 ERF=80000180 



(1) 

(2) 
(3) 
(4) 
(5) 



Example 6-4 Diagnostic Register Dump 

The numbers in parenthesis on the right side of Example 6—4 refer to 
lines of the display and are not a part of the diagnostic dump. The 
information on these lines is summarized as follows: 

1. Test summary containing six hexadecimal fields. 

a. ?34, test identifies the diagnostic test. 

b. 2, severity is the level of a test failure, as dictated by the script. 
Failure of a severity level 2 test causes the display of this five-line 
error printout, and halts an autoboot to console I/O mode. An 
error of severity level 1 displays the first line of the error printout, 
but does not interrupt an autoboot. Most tests have a severity 
level of 2. 

c. 08, error is a number, that in conjunction with listing files, 
isolates to within a few instructions where the diagnostic detected 
the error. This field is also called the subtestlog. 



6—74 Maintenance Mode Firmware 



d. FF, de_error is a code with which the diagnostic executive signals 
the diagnostic's state and any illegal behavior. This field indicates 
a condition that the diagnostic expects on detecting a failure. The 
possible codes are: 

FF - Normal error exit from diagnostic 

FE - Unanticipated interrupt 

FD - Interrupt in cleanup routine 

FC - Interrupt in interrupt handler 

FB - Script requirements not met 

FA - No such diagnostic 

EF - Unanticipated exception in executive 

e. 00, vector is the SCB vector (if non-zero) through which an 
unexpected exception or interrupt trapped, when the de_error 
field indicates an unexpected exception or interrupt (FE or EF). 

f. 0000, count is the number of previous errors that have occurred. 

2. P1...P5 are the first five longwords of the diagnostic state. This is 
internal information that is used by repair personnel. 

3. P6...P10 are the last five longwords of the diagnostic state. 

4. R0...R4 are the first five GPRs at the moment the error was detected. 

5. R5...R8 are additional GPRs and ERF is a diagnostic summary 
longword. 

NOTE 

This information only applies to CVAX-based tests. R3000 tests 
(70-76) will display different registers. This information is only 
intended to be an example of an error display. 

6.4.2 Diagnostic Interdependences 

When running tests interactively on an individual basis, users should be 
aware that certain tests may be dependent on some state set up from a 
previous test. In general, tests should not be run out of order. 



Maintenance Mode Firmware 6—75 



6.4.3 Areas Not Covered 

The goal has been to achieve the highest possible coverage on the KN210 
and the memory boards. However, the testing of the KN210 while running 
with memory management turned on is minimal. Also, due to the way the 
firmware is implemented (a polled environment running at IPL 31), the 
testing of interrupts is not extensive. 

These diagnostics are not intended to be used as system level tests. There 
are no tests that completely verify that access to the Q22-bus will work. 
Thus, a disk, a controller, the backplane, or portions of the CQBIC may 
be faulty, and the diagnostics may not detect the fault. Such a fault may 
result later on as an inability to boot. 

6.5 Operating System Restart 

An operating system restart is the process of bringing up the operating 
system from a known initialization state following a processor halt. This 
procedure is often called restart or warmstart, and should not be confused 
with a processor restart which results in firmware entry. 

On the KN210 a restart occurs if the conditions specified in Table 6-1 are 
satisfied. 

lb restart a halted operating system, the firmware searches system 
memory for the restart parameter block (RPB), a data structure 
constructed for this purpose by VMB. If a valid RPB is found, the 
firmware passes control to the operating system at an address specified in 
the RPB. 

The firmware keeps a restart in progress (RIP) flag in CPMBX which it 
uses to avoid repeated attempts to restart a failing operating system. An 
additional RIP flag is maintained by the operating system in the RPB. 

The firmware uses the following algorithm to restart the operating 
system: 

1. Check CPMBX<3>(RIP). If it is set, restart fails. 

2. Print the message "Restarting system software" on the console 
terminal. 

3. Set CPMBX<3>(RIP). 

4. Search for a valid RPB. If none is found, restart fails. 

5. Check the operating system RPB$L_RSTRTFLG<0>(RIP) flag. If it is 
set, restart fails. 

6. Write "0" on the diagnostic LEDs. 



6—76 Maintenance Mode Firmware 



7. Dispatch to the restart address, RPB$L_RESTART, with : 

SP = the physical address of the RPB plus 512 
AP = the halt code 
PSL = 041F 0000 
PR$_MAPEN =0. 

If the restart is successful, the operating system must clear 
CPMBX<3>(RIP). 

If restart fails, the firmware prints "Restart failure" on the system 
console. 



6.5.1 Locating the RPB 

The RPB is a page aligned control block which can be identified by the 
first three longwords. The format of the RPB signature is shown in 
Figure 6-4. 



RPB: +00 
+ 04 
+ 08 



PHYSICAL ADDRESS OF THE RPB 



PHYSICAL ADDRESS OF THE RESTART ROUTINE 



CHECKSUM OF FIRST 31 LONGWORDS OF RESTART ROUTINE 



MA-X0056-BS 



Figure 6-4 RPB Signature Format 

The firmware uses the following algorithm to find a valid RPB: 

1. Search for a page of memory that contains its address in the first 
longword. If none is found, the search for a valid RPB has failed. 

2. Read the second longword in the page (the physical address of the 
restart routine). If it is not a valid physical address, or if it is zero, 
return to step 1. The check for zero is necessary to ensure that a page 
of zeros does not pass the test for a valid RPB. 

3. Calculate the 32 bit twos-complement sum (ignoring overflows) of the 
first 31 longwords of the restart routine. If the sum does not match 
the third longword of the RPB, return to step 1. 

4. A valid RPB has been found. 



Maintenance Mode Firmware 6—77 



6.6 Machine State on Power-Up 

This section describes the state of the KN210 after a power-up halt. 

The descriptions in this section assume a machine with no errors, that the 
machine has just been turned on and that only the power-up diagnostics 
have been run. The state of the machine is not denned if individual 
diagnostics are run or during any other halts other than a power-up halt 
(SAVPSL<13:8>(RESTART_CODE) = 3). 

The following sections describe data structures that are guaranteed to 
be constant over future versions of the maintenance mode firmware. 
Placement and/or existence of any other structure(s) is not implied. 

6.6.1 Main Memory Layout and State 

Main memory is tested and initialized by the firmware on power-up. 
Figure 6-5 is a diagram of how main memory is partitioned after 
diagnostics. 



PFN BITMAP 



QMR BASE 



AVAILABLE SYSTEM MEMORY 
(PAGES POTENTIALLY GOOD OR BAD) 



PFN BITMAP 

(48,12,16,20,24,28 OR 32 PAGES 

ON NEXT 32 Kbyte BOUNDARY BELOW QMRs) 



FIRMWARE "SCRATCH MEMORY" 
(BALANCE OF PAGES BETWEEN 
PFN BITMAP & QMRs) 



Q22-bus SCATTER/GATHER MAP 

(64 PAGES ALWAYS ON 32 Kbyte BOUNDARY) 



FIRST "GOOD" 
64 Kbyte BLOCK 
FROM THE TOP 



TOP OF MEMORY 



• POTENTIAL "BAD" MEMORY 



Figure 6-5 Memory Layout After Power-Up Diagnostics 



6—78 Maintenance Mode Firmware 



6.6.1.1 Reserved Main Memory 

In order to build the scatter/gather map and the bitmap, the firmware 
attempts to find a physically contiguous page aligned 64 Kbyte block of 
memory at the highest possible address that has no multiple bit errors. 
Single bit errors are tolerated in this section. 

Of the 64 Kbytes, the upper 32 Kbytes are dedicated to the Q22-bus 
scatter/gather map, as shown in Figure 6-5. Of the lower 32 Kbytes, up 
to 16 Kbytes at the bottom of the block is allocated to the page frame 
number (PFN) bitmap. The size of the PFN bitmap is dependent on the 
extent of physical memory, each bit in the bitmap maps one page (512 
bytes) of memory. The remainder of the block between the bitmap and 
scatter/gather map (minimally 16 Kbytes) is allocated for the firmware. 

6.6.1.2 PFN Bitmap 

The PFN bitmap is a data structure that indicates which pages in memory 
are deemed useable by operating systems. The bitmap is built by the 
diagnostics as a side effect of the memory tests on power-up. The bitmap 
always starts on a page boundary. The bitmap requires 1 Kbyte for every 
4 Mbytes of main memory. Therefore, an 8 Mbyte system requires 2 
Kbytes; 16 Mbyte requires 4 Kbytes; 32 Mbyte requires 8 Kbytes; and a 
64 Mbyte requires 16 Kbytes. The bitmap does not map itself or anything 
above it. There may be memory above the bitmap which has both good 
and bad pages. 

Each bit in the PFN bitmap corresponds to a page in main memory. There 
is a one to one correspondence between a PFN (origin 0) and a bit index 
in the bitmap. A one in the bitmap indicates that the page is good and 
can be used. A zero indicates that the page is bad and should not be 
used. By default, a page is flagged bad, if a multiple bit error occurs when 
referencing the page. Single bit errors, regardless of frequency, will not 
cause a page to be flagged bad. 

The PFN bitmap is protected by a checksum stored in the NVRAM. The 
checksum is a simple byte wide, two's complement checksum. The sum of 
all bytes in the bitmap and the bitmap checksum should result in zero. 
Operating systems that modify the bitmap are encouraged to update this 
checksum to faciliate diagnosis by service personnel. 



Maintenance Mode Firmware 6—79 



6.6.1.3 Scatter/Gather Map 

On power-up, the scatter/gather map is initialized by the firmware to map 
to the first 4 Mbytes of main memory. Main memory pages will not be 
mapped, if there is a corresponding page in Q22-bus memory, or if the 
page is marked bad by the PFN bitmap. 

On a processor halt other than power-up, the contents of the 
scatter/gather map is undefined, and is dependent on operating system 
usage. 

Operating systems should not move the location of the scatter/gather 
map, and should access the map only on aligned longwords through the 
local I/O space of 2008 8000 to 2008 FFFC, inclusive. The Q22-bus map 
base register, (QMBR) is set up by the firmware to point to this area, and 
should not be changed by software. 

6.6.1.4 Contents of Main Memory 

The contents of main memory are undefined after the diagnostics have 
run. Typically, non-zero test patterns will be left in memory. 

The diagnostics scrub all of main memory, so that no power-up induced 
errors remain in the memory system. On the KN210 memory subsystem, 
the state of the ECC bits and the data bits are undefined on initial power- 
up. This can result in single and multiple bit errors if the locations are 
read before written because the ECC bits are not in agreement with their 
correspsonding data bits. An aligned longword write to every location 
(done by diagnostics) eliminates all power-up induced errors. 

6.6.2 CMCTL Registers 

The maintenance mode firmware assigns bank numbers to CMCTL 
registers in ascending order, without attempting to disable physical banks 
that contain errors. High order unused banks are set to zero. Error 
loggers should capture the following bits from each MEMCSR register. 

MEMCSR<31> (bank enable bit). As the firmware always assigns 
banks in ascending order, knowing which banks are enabled is sufficient 
information to derive the bank numbers. MEMCSR<1:0> (bank usage). 
This field determines the size of the banks on the particular memory 
board. 

Additional information should be captured from the MCSR16 and 
MCSR17 as needed. 



5-80 Maintenance Mode Firmware 



6.6.3 First Level Cache 



The first level cache is tested during the power-up diagnostics, flushed 
and then turned off. The cache is again turned on by the BOOT and the 
INIT command. Otherwise, the state of the first level cache is disabled. 



6.6.4 Translation Buffer 

The CPU translation buffer is tested by diagnostics on power-up, but not 
used by the firmware since it runs in physical mode. The translation 
buffer can be invalidated by using PR$_TBIA, IPR 57. 

6.6.5 Halt Protected Space 

Halt protected space is from 2004 0000 to 2005 FFFF, inclusive, for the 
128 Kbytes of maintenance mode firmware on the KN210. The halt 
unprotected space is from 2006 0000 to 2008 FFFF. 

The diagnostic processor firmware always runs in halt protected space. 
When passing control to the bootstrap, the firmware exits the halt 
protected space, so if halts are enabled, and the halt line is asserted, 
the processor will then halt before booting. 

The SSC decodes both spaces (256 Kbyte). That is, the ROMs appear 
twice in the address space. However, the halt protected space is set to 128 
Kbyte, the size of the EPROMs. 

6.7 Public Data Structures and Entry Points 

This section describes public data structures and subroutine entry points 
that are public and are guaranteed to be compatible over future versions 
of the maintenance mode firmware. 

6.7.1 Maintenance Mode Firmware EPROM Layout 

The KN210 maintenance mode uses one 128 Kbyte EPROM. 
Approximately 120 Kbytes of this is used for code, with the remaining 
reserved for future expansion and customer usage. There are two copies 
of the firmware, one in halt protected space, and one in halt unprotected 
space. Both copies are identical. 



Maintenance Mode Firmware 6-81 



HALT PROTECT 
ADDRESS 



2004 0000 
2004 0006 
2004 0008 
2004 O00C 
2004 0010 
2004 0014 

2004 0018 
2004 001C 



2005 F800 
2005 FFFC 



BRANCH INSTRUCTION 



SYSTEM ID EXTENSION 



CPSGETCHAR R4 



CP$MSG OUT NOLF R4 



CPSREAD WITH PRMPT R4 



RESERVED 



DEFAULT BOOT DEVICE 
DESCRIPTOR POINTER 



DEFAULT BOOT FLAGS 
POINTER 



CONSOLE, DIAGNOSTIC 
AND BOOT CODE 



EPROM CHECKSUM 



RESERVED FOR DIGITAL 



4 PAGES RESERVED 
FOR CUSTOMER USE 



HALT UNPROTECT 
ADDRESS 



2006 0000 
2006 0006 
2006 0008 
2006 O00C 
2006 0010 
2006 0014 

2006 0018 
2006 001C 



2007 F800 
2007 FFFC 



MA-X0057-8S 



Figure 6-6 KN210 Maintenance Mode EPROM Layout 

The first instruction executed on halts is a branch around the system ID 
extension (SIE) and the callback entry points. This allows these public 
data structures to reside in fixed locations in the EPROM. 

The callback area entry points provide a simple interface to the currently 
denned console for VMB and secondary bootstraps. This is documented 
further in the next section. 

The EPROM checksum is a longword checksum from 2004 0000 to the 
checksum inclusive. The diagnostics use this to determine that the 
EPROMs can correctly be read. 

The memory between the checksum and the 4 page user area at the 
end of the EPROMs is reserved for DIGITAL for future expansion of the 
maintenance mode firmware. The contents of this area is set to FF. 



6-82 Maintenance Mode Firmware 



The four pages reserved for customer use are at the top of the EPROMs, 
and start at address 2005 F800 (halt protected space) or 2007 F800 (halt 
unprotected space). These areas are not "burned" and may be reburned 
by OEMs or end users. The area is not tested by the maintenance mode 
firmware and is not included in the checksum. 

6.7.2 Call-Back Entry Points 

The maintenance mode firmware provides several entry points that 
facilitate I/O to the designated console device. Users of these entry points 
do not need to be aware of the console device type, be it a video terminal 
or workstation. 

The primary intent of these routines is to provide a simple console device 
to VMB and secondary bootstraps, before operating systems load their 
own terminal drivers. 

These are JSB (subroutine as opposed to procedure) entry points located 
in fixed locations in the firwmare. These locations branch to code that in 
turn calls the appropriate routines. 

All of the entry points are designed to run at IPL 31 on the interrupt 
stack in physcial mode. Virtual mode is not supported. Due to internal 
firmware architectural restrictions, users are encouraged to only call into 
the halt protected entry points. These entry points are listed below. 

CP$GET_CHAR_ 2004 0008 

R4 

CP$MSG_OUT_ 2004 000C 

NOLFJR4 

CP$READ_WTH_ 2004 0010 

PRMPT_R4 

6.7.2.1 CP$GETCHAR_R4 

This routine returns the next character entered by the operator in R0. 
A timeout interval can be specified. If the timeout interval is zero, no 
timeout is generated. If a timeout is specified and if timeout occurs, a 
value of 18 (CAN) is returned instead of normal input. 

Registers RO, Rl, R2, R3 and R4 are modified by this routine, all others 
are preserved. 



Maintenance Mode Firmware 6—83 



; Usage with timeout : 

movl #timeout_in_tenths_of_second, rO 

jsb @#CP$GET_CHAR_R4 

cmpb rO,# A xl8 

beql timeout_handler 

; Input is in RO . 



Spe c i f y t ime out . 
Call routine. 
Check for timeout , 
Branch if timeout . 



; Usage without timeout : 

clrl rO 

j sb @ #CP $ GET_CHAR_R4 

; Input is in RO . 



; Specify no timeout . 
; Call routine. 



6.7.2.2 CP$MSG_OUT_NOLF_R4 

This routine outputs a message to the console. The message is specified 
either by a message code or a string descriptor. The routine distinguishes 
between message codes and descriptors by requiring that any descriptor 
be located outside of the first page of memory. Hence, message codes are 
restricted to values between and 511. 

Registers RO, Rl, R2, R3 and R4 are modified by this routine, all others 
are preserved. 



; Usage with message code: 

movzbl #console_message_code, rO 
jsb 8#CP$MSG_OUT_NOLF_R4 



; Specify message code. 
; Call routine. 



; Usage with a message descriptor (position dependent) 



movaq 5$ , rO 

jsb @#CP$MSG OUT N0LF_R4 



; Specify address of desc. 
; Call routine . 



5$: .ascid /This is a message/ ; Message with descriptor, 



; Usage with a message descriptor (position independent) . 



6-S4 Maintenance Mode Firmware 



pushab 5$ 

pushl #10$-5$ 

movl sp, rO 

j sb @ #CP $MS G_OUT_NOLF_R4 

clrq (sp)+ 



Generate message desc. 

on stack. 

Pass desc. addr . in RO , 

Call routine. 

Purge desc. from stack. 



5$: 
10$. 



ascii /This is a message/ 



Message. 



6.7.2.3 CP$READ_WTH_PRMPT_R4 

This routine outputs a prompt message and th en inputs a c haract er st ring 
from the console. When the input is accepted, | Delete | , |Ctrl| and [Ctrl| 
functions are supported. 

As with CP$MSG_OUT_NOLF_R4, either a message code or the address 
of a string descriptor is passed in RO to specify the prompt string. A value 
of zero results in no prompt. 

A descriptor of the input string is returned in RO and Rl. RO contains the 
length of the string and Rl contains the address. This routine inputs the 
string into the console program string buffer and therefore the caller need 
not provide an input buffer. Successive calls however destroy the previous 
contents of the input buffer. 

Registers RO, Rl, R2, R3 and R4 are modified by this routine, all others 
are preserved. 



Usage with a message descriptor (position independent) 



pushab 10$ 

pushl #10 $-5$ 

movl sp, rO 

jsb @#CP$READ_WTH_PRMPT_R4 

clrq (sp)+ 



Generate prompt desc. 

on stack . 

Pass desc. addr. in RO. 

Call routine. 

Purge prompt desc. 

Input desc in RO and Rl , 



5$: 
10$: 



.ascii /Prompt> / ; Prompt string. 



Maintenance Mode Firmware 6—85 



6.7.3 SSC RAM Layout 

The maintenance mode firmware uses the 1 Kbyte of battery backed up 
(BBU) RAM in the SSC for storage of firmware specific data structures 
and other information that must be preserved across power cycles. This 
nonvolatile RAM (NVRAM) resides in the SSC chip starting at address 
2014 0400. The NVRAM should not be used by the operating systems 
except as documented below. This NVRAM is not reflected in the bitmap 
built by the firmware. 



2014 0400 



2014 07FC 



PUBLIC DATA STRUCTURES 
(CPMBX, ETC.) 



R3000 STATE 



FIRMWARE STACK 



DIAGNOSTIC STATE 



RESERVED FOR 
CUSTOMER USE 



MA-X0058-8Q 



Figure 6-7 KN21 SSC NVRAM Layout 



6.7.4 Public Data Structures 

The following is a list of the public data structures in NVRAM used by 
the console. 

Fields that are designated as reserved and/or internal use should not be 
written, since there is no protection against such corruption. 

6.7.4.1 Console Program Mailbox 

The console program mailbox (CPMBX) is a software data structure 
located at the beginning of NVRAM (2014 0400). The CPMBX is used 
to pass information between the maintenance mode firmware and 
diagnostics, VMB, or an operating system. It consists of three bytes 
referred to here as NVR0, NVR1, and NVR2 shown in Figures 6-8 
through 6-10. 



6—86 Maintenance Mode Firmware 



NVRO 



LANGUAGE 


RIP 


BIP 


HLT_ACT 



Figure 6-8 NVRO 



Field Name 



Description 



7:4 LANGUAGE This field specifies the current selected language for 

displaying halt and error messages on terminals which 
support MCS. 

3 RIP If set, a restart attempt is in progress. This flag must be 

cleared by the operating system, if the restart succeeds. 

2 BIP If set, a bootstrap attempt is in progress. This flag must be 

cleared by the operating system if the bootstrap succeeds. 

1:0 HLT_ Processor halt action - this field, in conjunction with 

ACT the conditions specified in Table 6-1, is used to control 

the automatic restart/bootstrap procedure. HLT_ACT is 
normally written by the operating system. 



: Restart; if that fails, reboot; if that fails, halt. 

1 : Restart; if that fails, halt. 

2 : Reboot; if that fails, halt. 

3 : Halt. 



7 6 5 4 3 2 10 



NVR1 





MCS 


CRT 





2014 0401 



Figure 6-9 NVR1 



Maintenance Mode Firmware 6—87 



Field Name 



Description 



MCS If set, indicates that the attached terminal supports 

multinational character set (MCS). If clear, MCS is not 
supported. 

CRT If set, indicates that the attached terminal is a CRT. If 

clear, indicates that the terminal is hardcopy. 



KEYBOARD 



2014 0402 



Figure 6-10 NVR2 



Field Name 



Description 



7:0 



KEYBOARD This field indicates the national keyboard variant in use. 



6.7.4.2 Firmware Stack 

This section contains the stack that is used by all of the firmware, with 
the exception of VMB, which has its own built in stack. 

6.7.4.3 Diagnostic State 

This area is used by the firmware resident diagnostics. This section is not 
documented here. 

6.7.4.4 User Area 

The KN210 console reserves the last longword (address 2014 07FC) of 
the NVRAM for customer use. This location is not tested by the console 
firmware. Its value is undefined. 



6.8 Error Messages 



The error messages issued by the maintenance mode firmware fall into 
three catgories, halt code messages, VMB error messages, and console 
messages. 



6-88 Maintenance Mode Firmware 



6.8.1 Halt Code Messages 

Except on power-up, which is not treated as an error condition, the 
following messages are issued by the firmware whenever the processor 
halts. 

For example: 

?06 HLT INST 
PC = 800050D3 

The number preceding the halt message is the halt code. This number 
is obtained from SAVPSL<13:8>(RESTART_CODE), IPR 43, which is 
written on any CVAX processor restart operation. 



Table 6-10 HALT Messages 



Code Message 



Description 



?02 
_03 

?04 



EXT HLT 



ISP ERR 



?05 


DBL ERR 


?06 


HLT INST 


?07 


SCB ERR3 


?08 


SCB ERR2 


?0A 


CHMFR 




ISTK 


?0B 


CHMTO 




ISTK 


?0C 


SCB RD ERR 



External halt, caused by either console BREAK 

condition or Q22-bus BHALTJL. 

Power-up, no halt message is displayed; _03 is not 

displayed. However, the presence of the firmware 

banner and diagnostic countdown indicates this halt 

reason. 

In attempting to push state onto the interrupt stack 

during an interrupt or exception, the processor 

discovered that the interrupt stack was mapped NO 

ACCESS or NOT VALID. 

The processor attempted to report a machine check 

to the operating system, and a second machine check 

occurred. 

The processor executed a HALT instruction in kernel 

mode. 

The SCB vector had bits <1:0> equal to 3. 

The SCB vector had bits <1:0> equal to 2. 

A change mode instruction was executed when 

PSL<IS> was set. 

The SCB vector for a change mode had bit <0> set. 

A hard memory error occurred while the processor was 
trying to read an exception or interrupt vector. 



Maintenance Mode Firmware 6-89 



Table 6-1 (Cont.) HALT Messages 



Code Message 



?10 


MCHKAV 


?11 


KSPAV 


?12 


DBL ERR2 


?13 


DBL ERR3 


?19 


PSL EXC5 1 


?1A 


PSL EXC6 1 


?1B 


PSL EXC7 1 


?1D 


PSL REI5 1 


?1E 


PSL REI6 1 


?1F 


PSL REI7 1 



Description 



An access violation or an invalid translation occurred 

during machine check exception processing. 

An access violation or translation not valid occurred 

during processing of a kernel stack not valid exception. 

Double machine check error. A machine check occured 

while trying to service a machine check. 

Double machine check error. A machine check occured 

while trying to service a kernel stack not valid 

exception. 

PSL<26:24> = 5 on interrupt or exception. 

PSL<26:24> = 6 on interrupt of exception. 

PSL<26:24> = 7 on interrupt or exception. 

PSL<26:24> = 5 on an REI instruction 

PSL<26:24> = 6 on an REI instruction. 

PSL<26:24> = 7 on an REI instruction. 



1 For the last six cases, the VAX architecture does not allow execution on the interrupt stack 
while in a mode other than kernel. In the first three cases, an interrupt is attempting to 
run on the interrupt stack while not in kernel mode. In the last three cases, an REI 
instruction is attempting to return to a mode other than kernel and still run on the 
interrupt stack. 



6.8.2 Console Error Messages 

These error messages are issued in response to a console command that 
has error(s). 



Table 6-11 Console Error Messages 



Code Message 



Description 



?20 CORRPTN 

?21 ILL REF 



?22 



ILLCMD 



The console program database has been 

corrupted. 

Illegal reference. The requested reference would 

violate virtual memory protection, the address 

is not mapped, the reference is invalid in the 

specified address space, or the value is invalid in 

the specified destination. 

The command string cannot be parsed. 



6-90 Maintenance Mode Firmware 



Table 6-11 (Cont.) Console Error Messages 



Code Message 



Description 



?23 


INVDGT 


?24 


LTL 


?25 


ILL ADR 


?26 


VAL TOO LRG 


?27 


SWCONF 


?28 


UNKSW 


?29 


UNKSYM 


?2A 


CHKSM 



?2C 


FNDERR 


?2D 


TMOUT 


?2E 


MEM ERR 


?2F 


UNXINT 


?30 


UNIMPLEMENTED 


?31 


QUAL NOVAL 


?32 


QUAL AMBG 


?33 


QUAL REQ VAL 


?34 


QUAL OVERF 


?35 


ARG OVERF 


?36 


AMBGCMD 


?37 


INSUF ARG 



A number has an invalid digit. 

The command was too large for the console to 

buffer. The message is issued only after receipt of 

the terminating carriage return. 

The address specified falls outside the limits of 

the address space. 

The value specified does not fit in the destination. 

Switch conflict, for example, two different data 

sizes are specified for an EXAMINE command. 

The switch is unrecognized. 

The symbolic address in an EXAMINE or 

DEPOSIT command is unrecognized. 

The command or data checksum of an X command 

is incorrect. If the data checksum is incorrect, 

this message is issued, and is not abbreviated to 

Illegal command. 

The operator entered a HALT command. 

A FIND command failed either to find the RPB or 

128 Kbytes of good memory. 

During an X command, data failed to arrive in the 

time expected (60 seconds). 

A machine check occurred with a code of 80 (hex) 

or 81 (hex), indicating a read or write memory 

error. 

Unexpected interrupt or exception. 

Unimplemented function. 

Qualifier does not take a value. 

Ambiguous qualifier. 

Qualifier requires a value. 

Too many qualifiers. 

Too many arguments. 

Ambiguous command. 

Insufficient arguments. 



Maintenance Mode Firmware 6—91 



6.8.3 VMB error messages 

Table 6—12 lists errors issued by VMB. 
Table 6-12 VMB Error Messages 



Code Message 



Description 



?40 


NOSUCHDEV 


?41 


DEVASSIGN 


?42 


NOSUCHFILE 


?43 


FILESTRUCT 


?44 


BADCHKSUM 


?45 


BADFILEHDR 


?46 


BADIRECTORY 


?47 


FILNOTCNTG 


?48 


ENDOFFILE 


?49 


BADFILENAME 


?4A 


BUFFEROVF 


?4B 


CTRLERR 


?4C 


DEVINACT 


?4D 


DEVOFFLINE 


?4E 


MEMERR 


?4F 


SCBINT 


?50 


SCB2NDINT 


?51 


NOROM 


?52 


NOSUCHNODE 


?53 


INSFMAPREG 


?54 


RETRY 



No bootable devices found. 

Device is not present. 

Program image not found. 

Invalid boot device file structure. 

Bad checksum on header file. 

Bad file header. 

Bad directory file. 

Invalid program image format. 

Premature end of file encountered. 

Bad file name given. 

Program image does not fit in available memory. 

Boot device I/O error. 

Failed to initialize boot device. 

Device is offline. 

Memory initialization error. 

Unexpected SCB exception or machine check. 

Unexpected exception after starting program image. 

No valid ROM image found. 

No response from load server. 

Invalid memory configuration. 

No devices bootable, retrying. 



A 

Specifications 



This appendix contains the physical, electrical and environmental 
specifications for the KN210 CPU module and the KN210 I/O module. 

A.1 Physical Specifications 

The KN210 CPU module, KN210 I/O module and MS650-AA are quad- 
height modules with the following dimensions: 
Dimension Measurement 

Height 10.457 (+0.015/-0.020) inches 

Length 8.430 (+0.010/-0.010) inches 

Width 0.375 inches maximum (nonconductive) 

0.343 inches maximum (conductive) 

NOTE 

Width, as defined for Digital modules, is the height of components 

above the surface of the module. 

A.2 Electrical Specifications 

The power requirements for the KN210 CPU module are as follows: 

+5 V ±5% +12V ±5% 

4.5 A maximum 0.13 A maximum 

Typical currents are 10 percent less than the specified maximum. 



A-1 



A— 2 Specifications 

The bus loads for the KN210 CPU module are as follows: 

* 3.5 ac loads 

• 1.0 dc loads 

The power requirements for the KN210 I/O module are as follows: 

+5 V ±5% +12V ±5% 

5.0 A maximum 0.23 A maximum 

Typical currents are 10 percent less than the specified maximum. 
The KN210 I/O module does not present any loads to the Q22-bus. 

A.3 Environmental Specifications 

The environmental specifications for the KN210 CPU module and the 
KN210 I/O module are as follows: 

Operating Conditions 

Temperature 5°C (41°F) to 60°C (140°F) with a rate of change no greater 

than 20± 2°C (36± 4°F) per hour at sea level. Derate 
maximum temperature by 1.8°C for each 1000 meters (1°F 
for each 1000 ft) of altitude above sea level. 

Humidity 0% to 95% noncondensing, with a maximum wet bulb 

temperature of 32°C (90°F) and a minimum dew point 
temperature of 2°C (36°F). 

Altitude Up to 2,400 meters (8,000 ft) with a rate of change no 

greater than 300 meters per min (1000 ft per min). 

Nonoperating Conditions Less Than 60 Days 

Temperature -40°C to +66°C (-40°F to +151°F) with a rate of change no 

greater than 11± 2°C (20± 4°F) per hour at sea level. Derate 
the maximum temperature by 1.8°C for each 1000 meters 
(1 Q F for each 1000 ft) of altitude above sea level. 

Humidity Up to 95% noncondensing. 

Altitude Up to 4,900 meters (16,000 ft) with a rate of change no 

greater than 600 meters per min (2000 feet per min). 



Specifications A— 3 



Nonoperating Conditions Greater Than 60 Days 

Temperature +5°C to +60°C (+40°F to +140°F) with a rate of change no 

greater than 20± 2°C (36± 4°F) per hour at sea level. Derate 
the maximum temperature by 1.8°C for each 1000 meters 
(1°F for each 1000 ft) of altitude above sea level. 

Humidity 10% to 95% noncondensing, with a maximum wet bulb 

temperature of 32 °C (90°F) and a minimum dew point 
temperature of 2°C (36°F). 

Altitude Up to 2,400 meters (8,000 ft) with a rate of change no 

greater than 300 meters per min (1000 ft per min). 



B 

Address Assignments 



B.1 R3000 Physical Address Space Map 

Table B-l lists the R3000 memory space. 
Table B-1 R3000 Memory Space 

Contents Address Range 



Local memory space (Up to 64 Mbytes) 
Reserved memory space 



0000 0000 - 03FF FFFF 
0400 0000 - 1FFF FFFF 



Table B-2 lists the R3000 I/O memory space. 
Table B-2 R3000 I/O Space 



Contents 



Address Range 



Reserved Q-22 bus I/O space 1000 0000 - 1000 0007 

Q-22 bus floating address space 1000 0008 - 1000 07FF 

User reserved Q-22 bus I/O space 1000 0800 - 1000 OFFF 

Reserved Q-22 bus I/O space 1000 1000 - 1000 1F3F 

Interprocessor communication register 1000 1F40 

Reserved Q-22 bus I/O space 1000 1F48 - 1000 1FFF 

Reserved I/O module address space 1000 2000 - 1003 FFFF 

Two copies of local ROM 1004 0000 - 1007 FFFF 

DMA system configuration register 1008 0000 

DMA system error register 1008 0004 

DMA master error address register 1008 0008 

DMA slave error address register 1008 000C 



B-1 



B—2 Address Assignments 



Table B-2 (Cont.) R3000 I/O Space 



Contents 



Address Range 



Q-22 bus map base register 1008 0010 

Reserved 1008 0014 - 1008 00FF 

Main memory configuration register 00 1008 0100 

Main memory configuration register 01 1008 0104 

Main memory configuration register 02 1008 0108 

Main memory configuration register 03 1008 010C 

Main memory configuration register 04 1008 0110 

Main memory configuration register 05 1008 0114 

Main memory configuration register 06 1008 0118 

Main memory configuration register 07 1008 011C 

Main memory configuration register 08 1008 0120 

Main memory configuration register 09 1008 0124 

Main memory configuration register 10 1008 0128 

Main memory configuration register 11 1008 012C 

Main memory configuration register 12 1008 0130 

Main memory configuration register 13 1008 0134 

Main memory configuration register 14 1008 0138 

Main memory configuration register 15 1008 013C 

Main memory error status register 1008 0140 

Main memory control/diagnostic status 1008 0144 

register 

Reserved I/O module address space 1008 0148 - 1008 3FFF 

Interrupt status 1008 4000 

Boot and diagnostic register 1008 4004 

Select processor register 1008 4008 

100 Hz clock 1008 4010 

Reserved I/O module address space 1008 4014 - 1008 7FFF 

Q-22 bus map registers 1008 8000 - 1008 FFFF 

Reserved I/O module address space 1009 0000 - 1013 FFFF 

SSC base address register 1014 0000 

SSC configuration register 1014 0010 

CDAL bus timeout control register 1014 0020 

Diagnostic LED register 1014 0030 

Reserved I/O module address space 1014 0034 - 1014 0068 

Time-of-year register 1014 006C 

Reserved 1014 0070 - 1014 007C 

Console receiver control/status 1014 0080 



Address Assignments B-3 



Table B-2 (Cont.) R3000 I/O Space 



Contents 



Address Range 



1014 00DB 



1014 00FF 



Console receiver data buffer 1014 0084 

Console transmitter control/status 1014 0088 

Console transmitter data buffer 1014 008C 

Reserved 1014 0090 - 

I/O system reset register 1014 OODC 

Reserved 1014 00E0 

ROM data register 1014 00F0 

Bus timeout counter 1014 00F4 

Interval timer 1014 00F8 

Reserved 1014 OOFC - 

Timer control register 1014 0100 

Timer interval register 1014 0104 

Timer next interval register 1014 0108 

Timer interrupt vector 1014 010C 

Timer 1 control register 1014 0110 

Timer 1 interval register 1014 0114 

Timer 1 next interval register 1014 0118 

Timer 1 interrupt vector 1014 011C 

Address decode match register 1014 0130 

Address decode mask register 1014 0134 

Reserved 1014 0138 - 

Battery backed-up RAM 1014 0400 - 

Local Q-22 bus memory space 1400 0000 - 

Reserved (4 copies local Q-22 memory) 1440 0000 - 

Reserved 1500 0000 - 

Vector read register 1600 0050 1 

Vector read register 1 1600 0054 1 

Vector read register 2 1600 0058 1 

Vector read register 3 1600 005C 1 

Reserved 1600 0060 - 

Write error address register 1700 0000 1 

Reserved 1700 0004 - 

ROM 1FC0 0000 - 

Reserved 1FC2 0000 - 



1014 033F 
1014 07FF 
143F FFFF 
14FF FFFF 
1600 004F 



16FF FFFF 

1FBFFFFF 
1FC1 FFFF 1 
FFFF FFFF 



1 Only accessible from R3000 processor. 



B-4 Address Assignments 

B.2 CVAX Physical Address Space Map 

Table B-3 lists the CVAX memory space. 
Table B-3 VAX Memory Space 

Contents Address Range 

Local memory space (Up to 64 Mbytes) 0000 0000 - 03FF FFFF 

Reserved memory space 0400 0000 - 1FFF FFFF 



Table B— 4 lists the VAX input/output memory space. 

Table B^4 CVAX I/O Space 

Contents Address Range 

Reserved Q22-bus I/O space 2000 0000 - 2000 0007 

Q22-bus floating address space 2000 0008 - 2000 07FF 

User reserved Q22-bus I/O space 2000 0800 - 2000 OFFF 

Reserved Q22-bus I/O space 2000 1000 - 2000 1F3F 

Interprocessor communication register 2000 1F40 

Reserved Q22-bus I/O space 2000 1F48 - 2000 1FFF 

Reserved I/O module address space 2000 2000 - 2003 FFFF 

MicroVAX system type register (in ROM) 2004 0004 

Local ROM - halt mode 2004 0000 - 2005 FFFF 

Local ROM - run mode 2006 0000 - 2007 FFFF 

DMA system configuration register 2008 0000 

DMA system error register 2008 0004 

DMA master error address register 2008 0008 

DMA slave error address register 2008 000C 

Q22-bus map base register 2008 0010 

Reserved 2008 0014 - 2008 OOFF 

Main memory configuration register 00 2008 0100 

Main memory configuration register 01 2008 0104 

Main memory configuration register 02 2008 0108 

Main memory configuration register 03 2008 010C 

Main memory configuration register 04 2008 0110 

Main memory configuration register 05 2008 0114 

Main memory configuration register 06 2008 0118 

Main memory configuration register 07 2008 011C 

Main memory configuration register 08 2008 0120 



Address Assignments B— 5 



Table B-4 (Cont.) CVAX I/O Space 



Contents 



Address Range 



Main memory configuration register 09 2008 0124 

Main memory configuration register 10 2008 0128 

Main memory configuration register 11 2008 012C 

Main memory configuration register 12 2008 0130 

Main memory configuration register 13 2008 0134 

Main memory configuration register 14 2008 0138 

Main memory configuration register 15 2008 013C 

Main memory error status register 2008 0140 

Main memory control/diagnostic status 2008 0144 

register 

Reserved I/O module address space 2008 0148 - 2008 3FFF 

Interrupt status 2008 4000 

Boot and diagnostic register 2008 4004 

Select processor register 2008 4008 

100 Hz clock 2008 4010 

Reserved I/O module address space 2008 4014 - 2008 7FFF 

Q-22 bus map registers 2008 8000 - 2008 FFFF 

Reserved I/O module address space 2009 0000 - 2013 FFFF 

SSC base address register 2014 0000 

SSC configuration register 2014 0010 

CDAL bus timeout control register 2014 0020 

Diagnostic LED register 2014 0030 

Reserved I/O module address space 2014 0034 - 2014 0068 

Time-of-year register 2014 006C 

Reserved 2014 0070 - 2014 007C 

Console receiver control/status 2014 0080 

Console receiver data buffer 2014 0084 

Console transmitter control/status 2014 0088 

Console transmitter data buffer 2014 008C 

Reserved 2014 0090 - 2014 00DB 

I/O system reset register 2014 00DC 

Reserved 2014 00E0 

ROM data register 2014 00F0 

Bus timeout counter 2014 00F4 

Interval timer 2014 00F8 

Reserved 2014 00FC - 2014 00FF 

Timer control register 2014 0100 



B— 6 Address Assignments 



Table B-4 (Cont.) CVAX I/O Space 



Contents 



Address Range 



Timer interval register 

Timer next interval register 

Timer interrupt vector 

Timer 1 control register 

Timer 1 interval register 

Timer 1 next interval register 

Timer 1 interrupt vector 

Address decode match register 

Address decode mask register 

Reserved 

Battery backed-up RAM 

Reserved I/O module address space 

Local Q-22 bus memory space 

Reserved I/O module address space 



2014 0104 

2014 0108 

2014 010C 

2014 0110 

2014 0114 

2014 0118 

2014 011C 

2014 0130 

2014 0134 

2014 0138 - 2014 033F 

2014 0400 - 2014 07FF 

2014 0800 - 2FFF FFFF 

3000 0000 - 303F FFFF 

3040 0000 - 3FFF FFFF 



B.2.1 External IPRs 

Several of the internal processor registers (IPRs) on the KN210 CPU 
module are implemented in the SSC rather than in the CVAX chip. These 
registers are referred to as external IPRs, and are listed in Table B— 5. 



Table B-5 External IPRs 



EPR 

Number Register Name 



Abbreviation 



27 


Time-of-year register 


TODR 


28-31 


Reserved 




32 


Console receiver 
control/status 


RXCS 


33 


Console receiver data buffer 


RXDB 


34 


Console transmitter 
control/status 


TXCS 


35 


Console transmitter data 
buffer 


TXDB 


55 


I/O system reset register 


IORESET 



Address Assignments B— 7 



B.3 Global Q22-bus Address Space Map 

The addresses and memory contents of the Q22-bus memory space are 
Usted in Table B-6. 

Table B-6 Q22-bus Memory Space 

Contents Address Range 

Q22-bus memory space (octal) 0000 0000 - 1777 7777 

The contents and addresses of the Q22-bus I/O space with BBS7 asserted 
are listed Table B-7. 

Table B-7 Q22-bus I/O Space with BBS7 Asserted 

Contents Address Range 

Q22-bus I/O space (octal) 1776 0000 - 1777 7777 

Reserved Q22-bus I/O space 1776 0000 

Q22-bus floating address space 1776 0010 - 1776 3777 

User reserved Q22-bus I/O space 1776 4000 - 1776 7777 

Reserved Q22-bus I/O space 1777 0000 - 1777 7477 

Interprocessor communication register 1777 7500 

Reserved Q22-bus I/O space 1777 7502 - 1777 7777 



c 

Q22-bus Specification 



C.1 Introduction 

The Q22-bus, also known as the extended LSI- 11 bus, is the low-end 
member of Digital's bus family. All of Digital's microcomputers, such 
as the MicroVAX I, MicroVAX II, MicroVAX 3500, MicroVAX 3600, and 
MicroPDP-11 use the Q22-bus. 

The Q22-bus consists of 42 bidirectional and 2 unidirectional signal lines. 
These form the lines along which the processor, memory, and I/O devices 
communicate with each other. 

Addresses, data, and control information are sent along these signal 
lines, some of which contain time-multiplexed information. The lines are 
divided as follows: 

• Sixteen multiplexed data/address lines — BDAL<15:00> 

• Two multiplexed address/parity lines — BDAL<17:16> 

• Four extended address lines — BDAL<21:18> 

• Six data transfer control lines — BBS7, BDIN, BDOUT, BRPLY, 
BSYNC, BWTBT 

• Six system control lines — BHALT, BREF, BEVNT, BINIT, BDCOK, 
BPOK 

• Ten interrupt control and direct memory access control lines — 
BIAKO, BIAKI, BIRQ4, BIRQ5, BIRQ6, BIRQ7, BDMGO, BDMR, 
BSACK, BDMGI 

In addition, a number of power, ground, and space lines are defined for 
the bus. Refer to Table C— 1 for a detailed description of these lines. 



C-1 



C— 2 Q22-bus Specification 



The discussion in this appendix applies to the general 22-bit physical 
address capability. All modules used with the KN210 CPU module must 
use 22-bit addressing. 

Most Q22-bus signals are bidirectional and use terminations for a 
negated (high) signal level. Devices connect to these lines by way of 
high-impedance bus receivers and open collector drivers. The asserted 
state is produced when a bus driver asserts the line low. 

Although bidirectional lines are electrically bidirectional (any point 
along the line can be driven or received), certain lines are functionally 
unidirectional. These lines communicate to or from a bus master (or 
signal source), but not both. Interrupt acknowledge (BIAK) and direct 
memory access grant (BDMG) signals are physically unidirectional in 
a daisy-chain fashion. These signals originate at the processor output 
signal pins. Each is received on device input pins (BIAKI or BDMG-I) 
and is conditionally retransmitted through device output pins (BIAKO 
or BDMGO). These signals are received from higher priority devices and 
are retransmitted to lower priority devices along the bus, establishing the 
position-dependent priority scheme. 

C.1.1 Master/Slave Relationship 

Communication between devices on the bus is asynchronous. A 
master/slave relationship exists throughout each bus transaction. Only 
one device has control of the bus at any one time. This controlling device 
is termed the bus master, or arbiter. The master device controls the bus 
when communicating with another device on the bus, termed the slave. 

The bus master (typically the processor or a DMA device) initiates a bus 
transaction. The slave device responds by acknowledging the transaction 
in progress and by receiving data from, or transmitting data to, the bus 
master. Q22-bus control signals transmitted or received by the bus master 
or bus slave device must complete the sequence according to bus protocol. 

The processor controls bus arbitration, that is, which device becomes bus 
master at any given time. A typical example of this relationship is a disk 
drive, as master, transferring data to memory as slave. Communication 
on the Q22-bus is interlocked so that, for certain control signals issued 
by the master device, there must be a response from the slave in order to 
complete the transfer. It is the master/slave signal protocol that makes 
the Q22-bus asynchronous. The asynchronous operation precludes the 
need for synchronizing with, and waiting for, clock pulses. 



Q22-bus Specification C-3 



Since bus cycle completion by the bus master requires response from the 
slave device, each bus master must include a timeout error circuit that 
aborts the bus cycle if the slave does not respond to the bus transaction 
within 10 us. The actual time before a timeout error occurs must be 
longer than the reply time of the slowest peripheral or memory device on 
the bus. 

C.2 Q22-bus Signal Assignments 

Table C— 1 lists the data and address signal assignments. Table C— 2 lists 
the control signal assignments. Table C— 3 lists the power and ground 
signal assignments. Table C— 4 lists the spare signal assignments. 

Table C-1 Data and Address Signal Assignments 

Data and Address Signal Pin Assignment 

BDALO AU2 

BDAL1 AV2 

BDAL2 BE2 

BDAL3 BF2 

BDAL4 BH2 

BDAL5 BJ2 

BDAL6 BK2 

BDAL7 BL2 

BDAL8 BM2 

BDAL9 BN2 

BDAL10 BP2 

BDAL11 BR2 

BDAL12 BS2 

BDAL13 BT2 

BDAL14 BU2 

BDAL15 BV2 

BDAL16 AC1 

BDAL17 AD1 

BDAL18 BC1 

BDAL19 BD1 

BDAL20 BE1 

BDAL21 BF1 



C— 4 Q22-bus Specification 



Table C-2 Control Signal Assignments 



Control Signal Pin Assignment 



Data Control 




BDOUT 


AE2 


BRPLY 


AF2 


BDIN 


AH2 


BSYNC 


AJ2 


BWTBT 


AK2 


BBS7 


AP2 


Interrupt Control 




BIRQ7 


BP1 


BIRQ6 


AB1 


BIRQ5 


AA1 


BIRQ4 


AL2 


BIAKO 


AN2 


BIAKI 


AM2 


DMA Control 




BDMR 


AN1 


BSACK 


BN1 


BDMGO 


AS2 


BDMGI 


AR2 


System Control 




BHALT 


API 


BREF 


AR1 


BEVNT 


BR1 


BINIT 


AT2 


BDCOK 


BA1 


BPOK 


BB1 



Q22-bus Specification C-5 
Table C-3 Power and Ground Signal Assignments 

Power and Ground Pin Assignment 



+5 B (battery) or 


AS1 


+12 B (battery) 




+12 B 


BS1 


+5B 


AVI 


+5 


AA2 


+5 


BA2 


+5 


BV1 


+12 


AD2 


+12 


BD2 


+12 


AB2 


-12 


AB2 


-12 


BB2 


GND 


AC2 


GND 


AJ1 


GND 


AMI 


GND 


ATI 


GND 


BC2 


GND 


BJ1 


GND 


BM1 


GND 


BT1 



Table C-~4 Spare Signal Assignments 

Spare Pin Assignment 

SSparel AE1 

SSpare3 AH1 

SSpare8 BH1 

SSpare2 API 

MSpareA AK1 

MSpareB AL1 

MSpareB BKl 

MSpareB BL1 

PSparel AU1 

ASpare2 BUI 



C— 6 Q22-bus Specification 



C.3 Data Transfer Bus Cycles 

Data transfer bus cycles, executed by bus master devices, transfer 32-bit 
words or 8-bit bytes to or from slave devices. In block mode, multiple 
words can be transferred to sequential word addresses, starting from a 
single bus address. Data transfer bus cycles are listed and denned in 
Table C-5. 



Table C-5 Data Transfer Operations 







Function ('with, respect to 


Bus Cycle 


Definition 


the bus master) 


DATI 


Data word input 


Read 


DATO 


Data word output 


Write 


DATOB 


Data byte output 


Write-byte 


DATIO 


Data word input/output 


Read-modify-write 


DATIOB 


Data word input/byte 
output 


Read-modify-write byte 


DATBI 


Data block input 


Read block 


DATBO 


Data block output 


Write block 



The bus signals listed in Table C— 6 are used in the data transfer 
operations described in Table C-5. 



Table C-6 Bus Signals for Data Transfers 



Signal 



Definition 



Function 



BDAL<21:00> L 



BSYNCL 
BDINL 



22 data/address lines 



Bus cycle control 
Data input indicator 



BDAL<15:00> L are used 
for word and byte transfers. 
BDAL<17:16> L are used 
for extended addressing, 
memory parity error (16), and 
memory parity error enable (17) 
functions. BDAL<21:18> L are 
used for extended addressing 
beyond 256 Kbytes. 
Indicates bus transaction in 
progress. 
Strobe signals 



Q22-bus Specification C-7 



Table C-6 (Cont.) Bus Signals for Data Transfers 



Signal 


Definition 


Function 


BDOUTL 


Data output indicator 


Strobe signals 


BRPLYL 


Slave's acknowledge of 
bus cycle 


Strobe signals 


BWTBTL 


Write/byte control 


Control signals 


BBS7 


I/O device select 


Indicates address is in the I/O 
page. 



Data transfer bus cycles can be reduced to five basic types: DATI, 
DATO(B), DATIO(B), DATBI, and DATBO. These transactions occur 
between the bus master and one slave device selected during the 
addressing part of the bus cycle. 

C.3.1 Bus Cycle Protocol 

Before initiating a bus cycle, the previous bus transaction must have been 
completed (BSYNC L negated) and the device must become bus master. 
The bus cycle can be divided into two parts: addressing and data transfer. 
During addressing, the bus master outputs the address for the desired 
slave device, memory location, or device register. The selected slave 
device responds by latching the address bits and holding this condition 
for the duration of the bus cycle until BSYNC L becomes negated. During 
data transfer the actual data transfer occurs. 



C.3.2 Device Addressing 

Device addressing of a data transfer bus cycle comprises an address setup 
and deskew time, and an address hold and deskew time. During address 
setup and deskew time, the bus master does the following operations: 

• Asserts BDAL<21:00> L with the desired slave device address bits. 

• Asserts BBS7 L if a device in the I/O page is being addressed. 

• Asserts BWTBT L if the cycle is a DATO(B) or DATBO bus cycle. 



C-8 Q22-bus Specification 



During this time, the address, BBS7 L, and BWTBT L signals are 
asserted at the slave bus receiver for at least 75 ns before BSYNC goes 
active. Devices in the I/O page ignore the nine high-order address bits 
BDAL<21:13>, and instead, decode BBS7 L along with the 13 low-order 
address bits. An active BWTBT L signal during address setup time 
indicates that a DATO(B) or DATBO operation follows, while an inactive 
BWTBT L indicates a DATT, DATBI, or DATIO(B) operation. 

The address hold and deskew time begins after BSYNC L is asserted. 

The slave device uses the active BSYNC L bus received output to 
clock BDAL address bits, BBS7 L, and BWTBT L into its internal 
logic. BDAL<21:00> L, BBS7 L, and BWTBT L remain active for 25 
ns minimum after the BSYNC L bus receiver goes active. BSYNC L 
remains active for the duration of the bus cycle. 

Memory and peripheral devices are addressed similarly, except for the 
way the slave device responds to BBS7 L. Addressed peripheral devices 
must not decode address bits on BDAL<21:13> L. Addressed peripheral 
device can respond to a bus cycle when BBS7 L is asserted (low) during 
the addressing of the cycle. When asserted, BBS7 L indicates that the 
device address resides in the I/O page (the upper 4K address space). 
Memory devices generally do not respond to addresses in the I/O page; 
however, some system applications may permit memory to reside in the 
I/O page for use as DMA buffers, read-only memory bootstraps, and 
diagnostics. 

DATI 

The DATI bus cycle, shown in Figure C-l, is a read operation. During 
DATI, data is input to the bus master. Data consists of 16-bit word 
transfers over the bus. During data transfer of the DATI bus cycle, the 
bus master asserts BDIN L 100 ns minimum after BSYNC L is asserted. 
The slave device responds to BDIN L active as follows: 

• Asserts BRPLY L ns minimum (8 ns maximum to avoid bus timeout) 
after receiving BDIN L, and 125 ns maximum before BDAL bus driver 
data bits are valid. 

• Asserts BDAL<21:00> L with the addressed data and error 
information ns (minimum) after receiving BDIN, and 125 ns 
(maximum) after assertion of BRPLY. 



Q22-bus Specification C— 9 



BUS MASTER 
PROCESSOR OR DEVICE 

ADDRESS DEVICE OR MEMORY 

ASSERT BDAL <21 :00> L WITH 

ADDRESS AND 

ASSERT BBS7 IF THE ADDRESS 

IS IN THE I/O PAGE 

ASSERT BSYNC L 



SLAVE 
MEMORY OR DEVICE 



DECODE ADDRESS 

STORE DEVICE SELECTED- 
OPERATION 



REQUEST DATA 

REMOVE THE ADDRESS FROM 
BDAL <21:00> LAND 
NEGATE BBS7 L 
ASSERT BDIN L 



INPUT DATA 

PLACE DATA ON BDAL < 15:00> L 
- ASSERT BRPLY L 



TERMINATE INPUT TRANSFER 
ACCEPT DATA AND RESPOND 
BY NEGATING BDIN L 



TERMINATE BUS CYCLE 
NEGATE BSYNC L 



OPERATION COMPLETED 
NEGATE BRPLY L 



MR-6028 
MA- 1074-87 



Figure C-1 DATI Bus Cycle 



C-1 Q22-bus Specification 



When the bus master receives BRPLY L, it does the following: 

• Waits at least 200 ns deskew time and then accepts input data 
at BDAL<17:00> L bus receivers. BDAL <17:16> L are used for 
transmitting parity errors to the master. 

• Negates BDIN L 200 ns minimum to 2 us maximum after BRPLY L 
goes active. 

The slave device responds to BDIN L negation by negating BRPLY L and 
removing read data from BDAL bus drivers. BRPLY L must be negated 
100 ns maximum prior to removal of read data. The bus master responds 
to the negated BRPLY L by negating BSYNC L. 

Conditions for the next BSYNC L assertion are as follows: 

• BSYNC L must remain negated for 200 ns minimum. 

• BSYNC L must not become asserted within 300 ns of previous BRPLY 
L negation. 

Figure C— 2 shows DAT! bus cycle timing. 

NOTE 

Continuous assertion of BSYNC L retains control of the bus by the 
bus master, and the previously addressed slave device remains 
selected. This is done for DATTO(B) bus cycles where DATO or 
DATOB follows a DAT! without BSYNC L negation and a second 
device addressing operation. Also, a slow slave device can hold 
off data transfers to itself by keeping BRPLY L asserted, which 
causes the master to keep BSYNC L asserted. 

DATOB 

DATOB, shown in Figure C— 3, is a write operation. Data is transferred in 
32-bit words (DATO) or 8-bit bytes (DATOB) from the bus master to the 
slave device. The data transfer output can occur after the addressing part 
of a bus cycle when BWTBT L has been asserted by the bus master, or 
immediately following an input transfer part of a DATIOB bus cycle. 



022-bus Specification C-11 




^ f 



100 ns MINIMUM 



3, /C 



TIMING AT MASTER DEVICE 



R/T DAL (4) ^ RADDR ^ 




> a 



TIMING AT SLAVE DEVICE 



NOTES: 

1. TIMING SHOWN AT MASTER AND SLAVE DEVICE 3. BUS DRIVER OUTPUT AND BUS RECEIVER INPUT 
BUS DRIVER INPUTS AND BUS RECEIVER OUTPUTS. SIGNAL NAMES INCLUDE A "B" PREFIX. 

2. SIGNAL NAME PREFIXES ARE DEFINED BELOW: 4. DONT CARE CONDITION. 

T= BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



Figure C-2 DATI Bus Cycle Timing 



G-1 2 Q22-bus Specification 



BUS MASTER 
(PROCESSOR OR DEVICE) 



SLAVE 
(MEMORY OR DEVICE) 



ADDRESS DEVICE/MEMORY 
ASSERT BDAL <21 :00> L WITH 
ADDRESS AND 

ASSERT BBS7L IF ADDRESS IS 
IN THE I/O PAGE 
ASSERT BWTBT L (WRITE 
CYCLE) 
ASSERT BSYNC L 



DECODE ADDRESS 

STORE DEVICE SELECTED 
OPERATION 



OUTPUT DATA 

REMOVE THE ADDRESS FROM 
BDAL<21:00> L AND NEGATE BBS7 L 
NEGATE BWTBT L UNLESS DATOB 
PLACE DATA ON BDAL < 15:00> L 
ASSERT BDOUT L — 



TAKE DATA 

RECEIVE DATA FROM BDAL 

LINES 

ASSERT BRPLY L 



TERMINATE OUTPUT TRANSFER 
NEGATE BDOUT L (AND BWTBT L 
IF IN A DATOB BUS CYCLE) 
REMOVE DATA FROM BDAL <15:00> L. 



OPERATION COMPLETED 
NEGATE BRPLY L 



TERMINATE BUS CYCLE 
NEGATE BSYNC L 



Figure C-3 DATO or DATOB Bus Cycle 



Q22-bus Specification C-13 



The data transfer part of a DATOB bus cycle comprises a data setup and 
deskew time and a data hold and deskew time. 

During the data setup and deskew time, the bus master outputs the data 
on BDAL<15:00> L at least 100 ns after BSYNC L assertion. BWTBT L 
remains negated for the length of the bus cycle. If the transfer is a byte 
transfer, BWTBT L remains asserted. If it is the output of a DATIOB, 
BWTBT L becomes asserted and lasts the duration of the bus cycle. 

During a byte transfer, BDAL<00> L selects the high or low byte. This 
occurs in the addressing part of the cycle. If asserted, the high byte 
(BDAL<15:08> L) is selected; otherwise, the low byte (BDAL<07:00> L) 
is selected. An asserted BDAL 16 L at this time forces a parity error to 
be written into memory if the memory is a parity-type memory. BDAL 
17 L is not used for write operations. The bus master asserts BDOUT L 
at least 100 ns after BDAL and BDWTBT L bus drivers are stable. The 
slave device responds by asserting BRPLY L within 10 us to avoid bus 
timeout. This completes the data setup and deskew time. 

During the data hold and deskew time, the bus master receives BRPLY 
L and negates BDOUT L, which must remain asserted for at least 150 
ns from the receipt of BRPLY L before being negated by the bus master. 
BDAL<17:00> L bus drivers remain asserted for at least 100 ns after 
BDOUT L negation. The bus master then negates BDAL inputs. 

During this time, the slave device senses BDOUT L negation. The data is 
accepted and the slave device negates BRPLY L. The bus master responds 
by negating BSYNC L. However, the processor does not negate BSYNC L 
for at least 175 ns after negating BDOUT L. This completes the DATOB 
bus cycle. Before the next cycle, BSYNC L must remain unasserted for at 
least 200 ns. Figure C-4 shows DATOB bus cycle timing. 

DATIOB 

The protocol for a DATIOB bus cycle is identical to the addressing and 
data transfer part of the DATI and DATOB bus cycles, and is shown in 
Figure C-5. After addressing the device, a DATI cycle is performed as 
explained earlier; however, BSYNC L is not negated. BSYNC L remains 
active for an output word or byte transfer (DATOB). The bus master 
maintains at least 200 ns between BRPLY L negation during the DATI 
cycle and BDOUT L assertion. The cycle is terminated when the bus 
master negates BSYNC L, as described for DATOB. Figure C-6 illustrates 
DATIOB bus cycle timing. 



C-1 4 Q22-bus Specification 



4 — t 



Ons MINIMUM 




MINIMUM 

TIMING AT MASTER DEVICE 




25 ns MINIMUM 

TIMING AT SLAVE DEVICE 

NOTES: 

1. TIMING SHOWN AT MASTER AND SLAVE DEVICE 3. BUS DRIVER OUTPUT AND BUS RECEIVER INPUT 
BUS DRIVER INPUTS AND BUS RECEIVER OUTPUTS. SIGNAL NAMES INCLUDE A "B" PREFIX. 

2. SIGNAL NAME PREFIXES ARE DEFINED BELOW: 4. DON'T CARE CONDITION. 

T = BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



Figure C-4 DATO or DATOB Bus Cycle Timing 



Q22-bus Specification G-1 5 



BUS MASTER 
(PROCESSOR OR DEVICE) 



SLAVE 
(MEMORY OR DEVICE) 



ADDRESS DEVICE/MEMORY 

ASSERT BDAL <21 :00> L WITH 

ADDRESS 

ASSERT BBS7L IF THE 

ADDRESS IS IN THE I/O PAGE 

ASSERT BSYNC L 



DECODE ADDRESS 

STORE DEVICE SELECTED 
OPERATION 



REQUEST DATA 

REMOVE THE ADDRESS FROM 
BDAL <21:00> L 
ASSERT BDIN L 



INPUT DATA 

PLACE DATA ON BDAL < 15:00 > L 
ASSERT BRPLY L 



TERMINATE INPUT TRANSFER 

ACCEPT DATA AND RESPOND BY 
TERMINATING BDIN L 



COMPLETE INPUT TRANSFER 
REMOVE DATA 
NEGATE BRPLY L 



OUTPUT DATA 

PLACE OUTPUT DATA ON BDAL < 15:00 > L 
(ASSERT BWTBT L IF AN OUTPUT 
BYTE TRANSFER) 
ASSERT BDOUT L 



TAKE DATA 

RECEIVE DATA FROM BDAL LINES 
ASSERT BRPLY L 



TERMINATE OUTPUT TRANSFER 

REMOVE DATA FROM BDAL LINES 
NEGATE BDOUT L 



TERMINATE BUS CYCLE 
NEGATE BSYNC L 
(AND BWTBT L IF IN 
A DATIOB BUS CYCLE) 



OPERATION COMPLETED 
NEGATE BRPLY L 



Figure C-5 DATIO or DATIOB Bus Cycle 



C-1 6 Q22-bus Specification 



150nsMINIMUM 



-I r 

R/TDAL (4|YtADDrV (4) V R DATA V 



JOOns 

MINIMUM 



/ 



150 ns. 
MINIMUM 



r 




— H f*- ns MINI 

— mi U- 100 ns MINIMUM 



X 

150 ns 175 ns / 



DO< 



T WTBT (4)\ 

3 



*- 100 ns MINIMUM 



100 ns MINIMUM- 




X 



ASSERTION = BYTE 



£ 



•150 ns MINIMUM 



TIMING AT MASTER DEVICE 



(4)YrADDrY (4) Y TDATA Y 

-H k 2! 

Imin 




•- 25 ns MINIMUM 



TIMING AT SLAVE DEVICE 



NOTES: 

1. TIMING SHOWN AT REQUESTING DEVICE 3. BUS DRIVER OUTPUT AND BUS RECEIVER INPUT 
BUS DRIVER INPUTS AND BUS RECEIVER OUTPUTS SIGNAL NAMES INCLUDE A "B" PREFIX. 

2. SIGNAL NAME PREFIXES ARE DEFINED BELOW: 4. DON'T CARE CONDITION. 

T= BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



Figure C-6 DATIO or DATIOB Bus Cycle Timing 



Q22-bus Specification C-17 



C.4 Direct Memory Access 

The direct memory access (DMA) capability allows direct data transfer 
between I/O devices and memory. This is useful when using mass storage 
devices (for example, disks) that move large blocks of data to and from 
memory. A DMA device needs to be supplied with only the starting 
address in memory the starting address in mass storage, the length 
of the transfer, and whether the operation is read or write. When this 
information is available, the DMA device can transfer data directly to or 
from memory. Since most DMA devices must perform data transfers in 
rapid succession or lose data, DMA devices are given the highest priority. 

DMA is accomplished after the processor (normally bus master) has 
passed bus mastership to the highest priority DMA device that is 
requesting the bus. The processor arbitrates all requests and grants the 
bus to the DMA device electrically closest to it. A DMA device remains 
bus master until it relinquishes its mastership. The following control 
signals are used during bus arbitration: 

• BDMGI L DMA grant input 

• BDMGO L DMA grant output 

• BDMR L DMA request line 

• BSACK L bus grant acknowledge 

C.4.1 DMA Protocol 

A DMA transaction can be divided into the following three phases: 

• Bus mastership acquisition phase 

• Data transfer phase 

• Bus mastership relinquishment phase 

During the bus mastership acquisition phase, a DMA device requests 
the bus by asserting BDMR L. The processor arbitrates the request and 
initiates the transfer of bus mastership by asserting BDMGO L. 

The maximum time between BDMR L assertion and BDMGO L assertion 
is DMA latency. This time is processor-dependent. BDMGO L/BDMGI L 
is one signal that is daisy-chained through each module in the backplane. 



C-18 Q22-bus Specification 



It is driven out of the processor on the BDMGO L pin, enters each module 
on the BDMGI L pin, and exits on the BDMGO L pin. This signal passes 
through the modules in descending order of priority until it is stopped by 
the requesting device. The requesting device blocks the output of BMDGO 
L and asserts BSACK L. If BDMR L is continuously asserted, the bus 
hangs. 

During the data transfer phase, the DMA device continues asserting 
BSACK L. The actual data transfer is performed as described earlier. 

The DMA device can assert BSYNC L for a data transfer 250 ns minimum 
after it received BDMGI L and its BSYNC L bus receiver is negated. 

During the bus mastership relinquishment phase, the DMA device gives 
up the bus by negating BSACK L. This occurs after completing (or 
aborting) the last data transfer cycle (BRPLY L negated). BSACK L 
can be negated up to a maximum of 300 ns before negating BSYNC L. 

NOTE 

If multiple data transfers are performed during this phase, 
consideration must be given to the use of the bus for other system 
functions, such as memory refresh (if required). 

Figure C— 7 shows the DMA protocol, and Figure C-8 shows DMA 
request/grant timing. 

C.4.2 Block Mode DMA 

For increased throughput, block mode DMA can be implemented on a 
device for use with memories that support this type of transfer. In a block 
mode transaction, the starting memory address is asserted, followed by 
data for that address, and data for consecutive addresses. 

By eUminating the assertion of the address for each data word, the 
transfer rate is almost doubled. 

There are two types of block mode transfers, DATBI (input) and DATBO 
(output). The DATBI bus cycle is described in Section C.4.2. 1 and 
illustrated in Figure C-9. 

The DATBO bus cycle is described in Section C.4.2.2 and illustrated in 
Figure C-10. 



Q22-bus Specification C-1 9 



PROCESSOR 
MEMORY IS SLAVE 



BUS MASTER 
CONTROLLER 



y 



REQUEST BUS 
ASSERT BDMR L 



GRANT BUS CONTROL 
NEAR THE END OF THE 
CURRENT BUS CYCLE ' 
(BRPLY L IS NEGATED) 
ASSERT BDMGO L AND 
INHIBIT NEW PROCESSOR 
GENERATED BSYNC L FOUR 
THE DURATION OF THE 
DMA OPERATION 



/ 



/ 



\ 



\ 



\ 



\ 



/ 



/ 



/ 



/ 



TERMINATE GRANT * 

SEQUENCE 

NEGATIVE BDMGO L AND 

WAIT FOR DMA OPERATION 

TO BE COMPLETED 

MONITOR TRANSACTION TO 
INVALIDATE CACHE IF 
CACHE HIT 



RESUME PROCESSOR 
OPERATION 
ENABLE PROCESSOR 
GENERATED BSYNC L 
(PROCESSOR IS BUS 
MASTER) OR ISSUE 
ANOTHER GRANT IF BDMR 
L IS ASSERTED 



ACKNOWLEDGE BUS 

MASTERSHIP 

RECEIVE BDMG 

WAIT FOR NEGATION OF 

BSYNC L AND BRPLY L 

ASSERT BSACK L 

NEGATE BDMR L 



EXECUTE A DMA DATA 

TRANSFER 

ADDRESS MEMORY AND 

TRANSFER UP TO 4 WORDS 

OF DATA AS DESCRIBED 

FOR DATI OR DATO BUS 

CYCLES 

RELEASE THE BUS BY 

TERMINATING BSACK L 

(NO SOONER THAN 

NEGATION OF LAST BRPLY L) 

AND BSYNC L 



WAIT FOUR uS OR UNTIL 
ANOTHER FIFO TRANSFER 
IS PENDING BEFORE 
REQUESTING BUS AGAIN 



MA-X00S6-B0A 



Figure C-7 DMA Protocol 



C-20 Q22-bus Specification 




NOTES: 

1. TIMING SHOWN AT REQUESTING DEVICE BUS DRIVER 
INPUTS AND BUS RECEIVER OUTPUTS. 



3. BUS DRIVER OUTPUT AND BUS RECEIVER INPUT 
SIGNAL NAMES INCLUDE A "B" PREFIX. 



2. SIGNAL NAME PREFIXES ARE DEFINED BELOW: 
T= BUS DRIVER INPUT 
R = BUS RECEIVER OUTPUT 



Figure C-8 DMA Request/Grant Timing 



Q22-bus Specification C-21 



T SACK 



T/R DAL 



R/T 
SYNC 




lOhX. 



m 



150 ns |« »|« » | 100 ns min 



T DIN - 
R RPLY- 



^ 



TT 



j 



100 ns 
min 



150 ns, 
min| 



200 ns 

— min 



\ 



\ 



/ 



/ 



\ 



/ 



\ 



V 



300 ns 
max 



r 



\ 



h 



Y 



xxv^\ xwwwwwwwwwwww 



TIMING AT MASTER DEVICE 

T = BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



R/T DAL 



100 ns max H — 




/ 



\ 



^ AVWWWWWWWWWWVW^ 



TIMING AT SLAVE DEVICE : 

T = BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



MA- 1088-87 



Figure C-9 DATBI Bus Cycle Timing 



C-22 Q22-bus Specification 



R DMG 




R REF 



TBS7 



z. 



TIMING AT MASTER DEVICE 

T = BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



J \ 



/ 



UNDEFINED 



R SYNC 



T RPLY 




Z 



UNDEFINED 



X 



j — V 



TIMING AT SLAVE DEVICE 

T = BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



MA-1087-87 



Figure C-10 DATBO Bus Cycle Timing 



Q22-bus Specification C-23 



C.4.2.1 DATBI Bus Cycle 

Before a DATBI block mode transfer can occur, the DMA bus master 
device must request control of the bus. This occurs under conventional 
Q22-bus protocol. 

A block mode DATBI transfer is executed as follows: 

• Address device memory— the address is asserted by the bus master 
on TADDR<21:00> along with the negation of TWTBT. The bus master 
asserts TSYNC 150 ns minimum after gating the address onto the 
bus. 

• Decode address— the appropriate memory device recognizes that it 
must respond to the address on the bus. 

• Request data-the address is removed by the bus master from 
TADDR<21:00> 100 ns minimum after the assertion of TSYNC. The 
bus master asserts the first TDIN 100 ns minimum after asserting 
TSYNC. The bus master asserts TBS7 50 ns maximum after asserting 
TDIN for the first time. TBS7 remains asserted until 50 ns maximum 
after the assertion of TDIN for the last time. In each case, TBS7 can 
be asserted or negated as soon as the conditions for asserting TDIN 
are met. The assertion of TBS7 indicates the bus master is requesting 
another read cycle after the current read cycle. 

• Send data— the bus slave asserts TRPLY ns minimum (8000 ns 
maximum to avoid a bus timeout) after receiving RDIN. The bus slave 
asserts TREF concurrent with TRPLY if, and only if, it is a block 
mode device which can support another RDIN after the current RDIN. 
The bus slave gates TDATA<15:00> onto the bus ns minimum after 
receiving RDIN and 125 ns maximum after the assertion of TRPLY. 

NOTE 

Block mode transfers must not cross 16-word boundaries. 

• Terminate input transfer— the bus master receives stable 
RDATA<15:00> from 200 ns maximum after receiving RRPLY until 
20 ns minimum after the negation of RDIN. (The 20 ns minimum 
represents total minimum receiver delays for RDIN at the slave and 
RDATA<15:00> at the master.) The bus master negates TDIN 200 ns 
minimum after receiving RRPLY. 



C-24 Q22-bus Specification 



• Operation completed— the bus slave negates TRPLY ns minimum 
after receiving the negation of RDIN. If RBS7 and TREF are both 
asserted when TRPLY negates, the bus slave prepares for another 
DIN cycle. RBS7 is stable from 125 ns after RDIN is received until 
150 ns after TRPLY negates. If TBS7 and RREF were both asserted 
when TDIN negated, the bus master asserts TDIN 150 ns minimum 
after receiving the negation of RRPLY and continues with the timing 
relationship in send data above. RREF is stable from 75 ns after 
RRPLY asserts until 20 ns minimum after TDIN negates. (The ns 
minimum represents total minimum receiver delays for RDIN at the 
slave and RREF at the master.) 

NOTE 

The bus master must limit itself to not more than eight 
transfers unless it monitors RDMR. If it monitors RDMR, 
it may perform up to 16 transfers as long as RDMR is not 
asserted at the end of the seventh transfer. 

• Terminate bus cycle— if RBS7 and TREF were not both asserted 
when TRPLY negated, the bus slave removes TDATA<15:00> from 
the bus ns minimum and 100 ns maximum after negating TRPLY. 
If TBS7 and RREF were not both asserted when TDIN negated, the 
bus master negates TSYNC 250 ns minimum after receiving the last 
assertion of RRPLY and ns minimum after the negation of that 
RRPLY. 

• Release the bus— the DMA bus master negates TSACK ns after 
negation of the last RRPLY. The DMA bus master negates TSYNC 
300 ns maximum after it negates TSACK. The DMA bus master must 
remove RDATA<15:00>, TBS7, and TWTBT from the bus 100 ns 
maximum after clearing TSYNC. 

At this point the block mode transfer is complete, and the bus arbitration 
logic in the CPU enables processor-generated TSYNC or issues another 
bus grant (TDMGO) if RDMR is asserted. 

C.4.2.2 DATBO Bus Cycle 

Before a block mode transfer can occur, the DMA bus master device 
must request control of the bus. This occurs under conventional Q22-bus 
protocol. 

A Block mode DATBO transfer is executed as follows: 

• Address device memory— the address is asserted by the bus master 
on TADDR<21:00> along with the aasertion of TWTBT. The bus 
master asserts TSYNC 150 ns minimum after gating the address onto 
the bus. 



Q22-bus Specification C-25 



Decode address-the appropriate memory device recognizes that it 
must respond to the address on the bus. 

Send data-the bus master gates TDATA<15:00> along with TWTBT 
100 ns minimum after the assertion of TSYNC. TWTBT is negated. 
The bus master asserts the first TDOUT 100 ns minimum after gating 
TDATA<15:00>. 

NOTE 

During DATBO cycles, TBS7 is undefined. 

Receive data— the bus slave receives stable data on RDATA<15:00> 
from 25 ns minimum before receiving RDOUT until 25 ns minimum 
after receiving the negation of RDOUT. The bus slave asserts TRPLY 
ns minimum after receiving RDOUT. The bus slave asserts TREF 
concurrent with TRPLY if, and only if, it is a block mode device which 
can support another RDOUT after the current RDOUT. 

NOTE 

Block mode transfers must not cross 16-word boundaries. 

Terminate output transfer-the bus master negates TDOUT 150 ns 
minimum after receiving RRPLY. 

Operation completed— the bus slave negates TRPLY ns minimum 
after receiving the negation of RDOUT. If RREF was asserted 
when TDOUT negated and if the bus master wants to transfer 
another word, the bus master gates the new data on TDATA<15:00> 
100 ns minimum after negating TDOUT. RREF is stable from 
75 ns maximum after RRPLY asserts until 20 ns minimum after 
RDOUT negates. (The 20 ns minimum represents minimum receiver 
delays for RDOUT at the slave and RREF at the master). The bus 
master asserts TDOUT 100 ns minimum after gating new data on 
TDATA<15:00> and 150 ns minimum after receiving the negation of 
RRPLY. The cycle continues with the timing relationship in receive 
data above. 

NOTE 

The bus master must limit itself to not more than 8 transfers 
unless it monitors RDMR. If it monitors RDMR, it may perform 
up to 16 transfers as long as RDMR is not asserted at the end 
of the seventh transfer. 



C-26 Q22-bus Specification 



• Terminate bus cycle— if RREF was not asserted when RRPLY 
negated or if the bus master has no additional data to transfer, the 
bus master removes data on TDATA<15:00> from the bus 100 ns 
minimum after negating TDOUT. If RREF was not asserted when 
TDOUT negated, the bus master negates TSYNC 275 ns minimum 
after receiving the last RRPLY and ns minimum after the negation 
of the last RRPLY. 

• Release the bus— the DMA bus master negates TSACK ns after 
negation of the last RRPLY. The DMA bus master negates TSYNC 
300 ns maximum after it negates TSACK. The DMA bus master must 
remove TDATA, TBS7, and TWTBT from the bus 100 ns maximum 
after clearing TSYNC. 

At this point the block mode transfer is complete, and the bus arbitration 
logic in the CPU enables processor-generated TSYNC or issues another 
bus grant (TDMGO) if RDMR is asserted. 

C.4.3 DMA Guidelines 

The following is a list of DMA guidelines: 

• Systems with memory refresh over the bus must not include devices 
that perform more than one transfer per acquisition. 

• Bus masters that do not use block mode are limited to four DATI, four 
DATO, or two DATIO transfers per acquisition. 

• Block mode bus masters that do not monitor BDMR are limited to 
eight transfers per acquisition. 

• If BDMR is not asserted after the seventh transfer, block mode bus 
masters that do monitor BDMR may continue making transfers 
until the bus slave fails to assert BREF, or until they reach the total 
maximum of 16 transfers. Otherwise, they stop after eight transfers. 



Q22-bus Specification C-27 



C.5 Interrupts 

The interrupt capability of the Q22-bus allows an I/O device to 
temporarily suspend (interrupt) current program execution and divert 
processor operation to service the requesting device. The processor inputs 
a vector from the device to start the service routine (handler). Like the 
device register address, hardware fixes the device vector at locations 
within a designated range below location 001000. The vector indicates the 
first of a pair of addresses. The processor reads the contents of the first 
address, the starting address of the interrupt handler. The contents of the 
second address is a new processor status word (PS). 

The new PS can raise the interrupt priority level, thereby preventing 
lower-level interrupts from breaking into the current interrupt service 
routine. Control is returned to the interrupted program when the 
interrupt handler is ended. The original interrupted program's address 
(PC) and its associated PS are stored on a stack. The original PC and 
PS are restored by a return from interrupt (RTI or RTT) instruction at 
the end of the handler. The use of the stack and the Q22-bus interrupt 
scheme can allow interrupts to occur within interrupts (nested interrupts), 
depending on the PS. 

Interrupts can be caused by Q22-bus options or the MicroVAX CPU. Those 
interrupts that originate from within the processor are called traps. Traps 
are caused by programming errors, hardware errors, special instructions, 
and maintenance features. 

The following Q22-bus signals are used in interrupt transactions: 

Signal Definition 

BIRQ4 L Interrupt request priority level 4 

BIRQ5 L Interrupt request priority level 5 

BIRQ6 L Interrupt request priority level 6 

BIRQ7 L Interrupt request priority level 7 

BIAKI L Interrupt acknowledge input 

BIAKO L Interrupt acknowledge output 

BDAL<21:00> Data/address lines 

BDIN L Data input strobe 

BRPLY L Reply 



C-28 Q22-bus Specification 

C.5.1 Device Priority 

The Q22-bus supports the following two methods of device priority: 

• Distributed arbitration — priority levels are implemented on the 
hardware. When devices of equal priority level request an interrupt, 
priority is given to the device electrically closest to the processor. 

• Position-defined arbitration — priority is determined solely by 
electrical position on the bus. The closer a device is to the processor, 
the higher its priority is. 

C.5.2 Interrupt Protocol 

Interrupt protocol on the Q22-bus has three phases: 

• Interrupt request 

• Interrupt acknowledge and priority arbitration 

• Interrupt vector transfer phase 

The interrupt request phase begins when a device meets its specific 
conditions for interrupt requests. For example, the device is ready, 
done, or an error occurred. The interrupt enable bit in a device status 
register must be set. The device then initiates the interrupt by asserting 
the interrupt request line(s). BIRQ4 L is the lowest hardware priority 
level and is asserted for all interrupt requests for compatibility with 
previous Q22-bus processors. The level at which a device is configured 
must also be asserted. A special case exists for level 7 devices that must 
also assert level 6. The following list gives the interrupt levels and the 
corresponding Q22-bus interrrupt request lines. For an explanation, refer 
to Section C.5.3. 

Interrupt Level Lines Asserted by Device 

4 BIRQ4 L 

5 BIRQ4 L, BIRQ5 L 

6 BIRQ4 L, BIRQ6 L 

7 BIRQ4 L, BIRQ6 L, BIRQ7 L 

Figure C— 11 shows the interrupt request/acknowledge sequence. 



Q22-bus Specification C-29 



PROCESSOR 



STROBE INTERRUPTS 
ASSERT BDIN L 



GRANT REQUEST 

PAUSE AND ASSERT BIAKO L 



DEVICE 



INITIATE REQUEST 
ASSERT BIRQ L 



RECEIVE BDIN L 

STORE "INTERRUPT SENDING* 
IN DEVICE 



RECEIVE BIAKI L 

RECEIVE BIAKI LAND INHIBIT 

BIAKO L 

PLACE VECTOR ON BDAL < 15:00 > L 

ASSERT BRPLY L 

NEGATE BIRQ L 



RECEIVE VECTOR AND 

TERMINATE REQUEST 
INPUT VECTOR ADDRESS 
NEGATE BDIN L AND BIAKO L 



COMPLETE VECTOR TRANSFER 

REMOVE VECTOR FROM BDAL BUS 
NEGATE BRPLY L 



PROCESS THE INTERRUPT 

SAVE INTERRUPTED PROGRAM 
PC AND PS ON STACK 
LOAD NEW PC AND PS FROM 
VECTOR ADDRESSED LOCATION 
EXECUTE INTERRUPT SERVICE 
ROUTINE FOR THE DEVICE 



Figure C-11 Interrupt Request/Acknowledge Sequence 



C-30 Q22-bus Specification 



The interrupt request line remains asserted until the request is 
acknowledged . 

During the interrupt acknowledge and priority arbitration phase, the 
processor acknowledges interrupts under the following conditions: 

• The device interrupt priority is higher than the current PS<7:5>. 

• The processor has completed instruction execution and no additional 
bus cycles are pending. 

The processor acknowledges the interrupt request by asserting BDIN L, 
and 150 ns minimum later asserting BIAKO L. The device electrically 
closest to the processor receives the acknowledge on its BIAKE L bus 
receiver. 

At this point, the two types of arbitration must be discussed separately. 
If the device that receives the acknowledge uses the four-level interrupt 
scheme, it reacts as follows: 

• If not requesting an interrupt, the device asserts BIAKO L and the 
acknowledge propagates to the next device on the bus. 

• If the device is requesting an interrupt, it must check that no higher- 
level device is currently requesting an interrupt. This is done by 
monitoring higher-level request lines. The following table lists the 
lines that need to be monitored by devices at each priority level: 

Device Priority Level Liae(s) Monitored 

4 BIRQ5, BIRQ6 

5 BIRQ6 

6 BIRQ7 

7 



Q22-bus Specification C— 31 



In addition to asserting levels 7 and 4, level 7 devices must drive level 
6. This is done to simplify the monitoring and arbitration by level 4 
and 5 devices. In this protocol, level 4 and 5 devices need not monitor 
level 7 because level 7 devices assert level 6. Level 4 and 5 devices 
become aware of a level 7 request because they monitor the level 6 
request. This protocol has been optimized for level 4, 5, and 6 devices, 
since level 7 devices are very seldom necessary. 

• If no higher-level device is requesting an interrupt, the acknowledge 
is blocked by the device. (BIAKO L is not asserted.) Arbitration logic 
within the device uses the leading edge of BDIN L to clock a flip-flop 
that blocks BIAKO L. Arbitration is won and the interrupt vector 
transfer phase begins. 

• If a higher-level request line is active, the device disqualifies itself 
and asserts BIAKO L to propagate the acknowledge to the next device 
along the bus. 

Signal timing must be considered carefully when implementing four-level 
interrupts (Figure C— 12). 



INTERRUPT LATENCY 
MINUS SERVICE TIME 




100 ns MAXIMUM 



(UNASSERTED) 



(UNASSERTED) 



NOTES: 

1. TIMING SHOWN AT REQUESTING DEVICE BUS DRIVER 
INPUTS AND BUS RECEIVER OUTPUTS. 

2. SIGNAL NAME PREFIXES ARE DEFINED BELOW: 

T= BUS DRIVER INPUT 

R = BUS RECEIVER OUTPUT 



3. BUS DRIVER OUTPUT AND BUS RECEIVER INPUT 
SIGNAL NAMES INCLUDE A "B" PREFIX. 



4. DON'T CARE CONDITION. 



Figure C-12 Interrupt Protocol Timing 



C-32 Q22-bus Specification 



If a single-level interrupt device receives the acknowledge, it reacts as 
follows: 

• If not requesting an interrupt, the device asserts BIAKO L and the 
acknowledge propagates to the next device on the bus. 

• If the device was requesting an interrupt, the acknowledge is blocked 
using the leading edge of BDIN L, and arbitration is won. The 
interrupt vector transfer phase begins. 

The interrupt vector transfer phase is enabled by BDIN L and BIAEI L. 
The device responds by asserting BRPLY L and its BDAL<15:00> L bus 
driver inputs with the vector address bits. The BDAL bus driver inputs 
must be stable within 125 ns maximum after BRPLY L is asserted. The 
processor then inputs the vector address and negates BDIN L and BIAKO 
L. The device then negates BRPLY L and 100 ns maximum later removes 
the vector address bits. The processor then enters the device's service 
routine. 

NOTE 

Propagation delay from BIAEI L to BIAKO L must not be greater 
than 500 ns per Q22-bus slot. The device must assert BRPLY L 
within 10 us maximum after the processor asserts BIAKI L. 

C.5.3 Q22-bus Four-Level Interrupt Configurations 

If you have high-speed peripherals and desire better software 
performance, you can use the four-level interrupt scheme. Both position- 
independent and position-dependent configurations can be used with the 
four-level interrupt scheme. 

Figure C— 13 shows the position-independent configuration. This allows 
peripheral devices that use the four-level interrupt scheme to be placed 
in the backplane in any order. These devices must send out interrupt 
requests and monitor higher-level request lines as described. The level 4 
request is always asserted from a requesting device regardless of priority. 
If two or more devices of equally high priority request an interrupt, the 
device physically closest to the processor wins arbitration. Devices that 
use the single-level interrupt scheme must be modified, or placed at the 
end of the bus, for arbitration to function properly. 



Q22-bus Specification C-33 







BIAK (INTERRUPT ACKNOWLEDGE) 




LEVEL 4 


BIAK 


LEVEL 6 




BIAK 


LEVEL E 




BIAK 


LEVEL 7 








DEVICE 




DEVICE 




DEVICE 




DEVICE 




Jl , 


. . 




BIRQ 4 (LEVEL 4 INTERRUPT REQUEST) , , 


" 


n 




" 


L 




" 


' 




BIRO S (LEVEL 5 INTERRUPT REQUEST) 








V 












BIRQ 6 (LEVEL 6 INTERRUPT REQUEST) 


" 








\ 






BIRQ 7 (LEVEL 7 INTERRUPT REQUEST) 












1 





Figure C-13 Position-Independent Configuration 

Figure C— 14 shows the position-dependent configuration. This 
configuration is simpler to implement. A constraint is that peripheral 
devices must be inserted with the highest priority device located closest 
to the processor, and the remaining devices placed in the backplane in 
decreasing order of priority (with the lowest priority devices farthest 
from the processor). With this configuration, each device has to assert 
only its own level and level 4. Monitoring higher-level request lines is 
unnecessary. Arbitration is achieved through the physical positioning of 
each device on the bus. Single-level interrupt devices on level 4 should be 
positioned last on the bus. 







BIAK (INTERRUPT ACKNOWLEDGE) 


LEVEL 7 


BIAK 


LEVEL 6 


BIAK 


LEVEL 5 


BIAK 


LEVEL 4 




BIRQ 4 (LEVEL 4 INTERRUPT REQUEST 


DEVICE 




DEVICE 




DEVICE 




DEVICE 


h , 


i ■ 


, i 


) 


1 


■ 




1 


' 




1 


1 


_J' 


BIRQ S (LEVEL 6 INTERRUPT REQUEST) j 


\ 


1 










BIRQ 6 (LEVEL 6 INTERRUPT REQUEST 


, | 




1 


< 












BIRQ 7 (LEVEL 7 INTERRUPT REQUEST 


» 1 


r 















MA-X0616-U 



Figure C-14 Position-Dependent Configuration 



G-34 Q22-bus Specification 

C.6 Control Functions 

The following Q22-bus signals provide control functions: 

Signal Definition 

BREF L Memory refresh (also block mode DMA) 

BHALT L Processor halt 

BINIT L Initialize 

BPOK H Power OK 

BDCOK H DC power OK 

C.6.1 Halt 

Assertion of BHALT L for at least 25 ns interrupts the processor, which 
stops program execution and forces the processor unconditionally into 
console I/O mode. 

C.6.2 Initialization 

Devices along the bus are initialized when BINIT L is asserted. The 
processor can assert BINIT L as a result of executing a reset instruction 
as part of a power-up or power-down sequence. BINIT L is asserted for 
approximately 10 us when reset is executed. 

C.6.3 Power Status 

Power status protocol is controlled by two signals, BPOK H and BDCOK 
H. These signals are driven by an external device (usually the power 
supply). 

C.7 Q22-bus Electrical Characteristics 

The input and output logic levels for Q22-bus signals are given in 
Section C.7.1. 



Q22-bus Specification C— 35 



C.7.1 Signal Level Specifications 

The signal level specifications for the Q22-bus are as follows: 

Input Logic Level 

TTL logical low 0.8 Vdc maximum 

TTL logical high 2.0 Vdc minimum 

Output Logic Level 

TTL logical low 

TTL logical high 0.4 Vdc maximum 



2.4 Vdc minimum 



C.7.2 Load Definition 



AC loads make up the maximum capacitance allowed per signal line to 
ground. A unit load is defined as 9.35 pF of capacitance. DC loads are 
defined as maximum current allowed with a signal line driver asserted or 
unasserted. A unit load is defined as 210 pA in the unasserted state. 

C.7.3 120-OhmQ22-bus 

The electrical conductors interconnecting the bus device slots are treated 
as transmission lines. A uniform transmission line, terminated in 
its characteristic impedance, propagates an electrical signal without 
reflections. Since bus drivers, receivers, and wiring connected to the 
bus have finite resistance and nonzero reactance, the transmission 
line impedance is not uniform, and introduces distortions into pulses 
propagated along it. Passive components of the Q22-bus (such as wiring, 
cabling, and etched signal conductors) are designed to have a nominal 
characteristic impedance of 120 ohms. 

The maximum length of interconnecting cable, excluding wiring within 
the backplane, is limited to 4.88 m (16 ft). 



C-36 Q22-bus Specification 



C.7.4 Bus Drivers 

Devices driving the 120-ohm Q22-bus must have open collector outputs 
and meet the following specifications: 

DC Specifications 

• Output low voltage when sinking 70 mA of current is 0.7 V maximum. 

• Output high leakage current when connected to 3.8 Vdc is 25 uA (even 
if no power is applied, except for BDCOK H and BPOK H). 

• These conditions must be met at worst-case supply temperature, and 
input signal levels. 

AC Specifications 

• Bus driver output pin capacitance load should not exceed 10 pF. 

• Propagation delay should not exceed 35 ns. 

• Skew (difference in propagation time between slowest and fastest 
gate) should not exceed 25 ns. 

• Transition time (from 10% to 90% for positive transition — rise time, 
from 90% to 10% for negative transition — fall time) must be no faster 
than 10 ns. 

C.7.5 Bus Receivers 

Devices that receive signals from the 120-ohm Q22-bus must meet the 
following requirements: 

DC Specifications 

• Input low voltage maximum is 1.3 V. 

• Input high voltage minimum is 1.7 V. 

• Maximum input current when connected to 3.8 Vdc is 80 uA (even if 
no power is applied). 

These specifications must be met at worst-case supply voltage, 
temperature, and output signal conditions. 



Q22-bus Specification C— 37 

AC Specifications 

• Bus receiver input pin capacitance load should not exceed 10 pF. 

• Propagation delay should not exceed 35 ns. 

• Skew (difference in propagation time between slowest and fastest 
gate) should not exceed 25 ns. 

C.7.6 Bus Termination 

The 120-ohm Q22-bus must be terminated at each end by an appropriate 
terminator, as shown in Figure C— 15. This is to be done as a voltage 
divider with its Thevenin equivalent equal to 120 ohms and 3.4 
V (nominal). This type of termination is provided by an REV11-A 
refresh/boot/terminator, BDV11-AA, KPV11-B, TEV11, or by certain 
backplanes and expansion cards. 

+5 V +5 V 



178 n | 330 ne 

120 n I 250 n 

— ►BUSLINE »► BUS LINE 

TERMINATION TERMINATION 

383 n £ 680 £2 > 

' % i i 

MR-6033 
MA- 107 1-87 

Figure C-15 Bus Line Terminations 

Each of the several Q22-bus lines (all signals whose mnemonics start 
with the letter B) must see an equivalent network with the following 
characteristics at each end of the bus: 



Bus Termination Characteristic Value 

Input impedance 120 ohm +5%, -15% 
(with respect to ground) 

Open circuit voltage 3.4 Vdc +5% 

Capacitance load Not to exceed 30 pF 



C-38 Q22-bus Specification 



NOTE 

The resistive termination can be provided by the combination 

of two modules. (The processor module supplies 220 ohms to 

ground. This, in parallel with another 220-ohm card, provides 120 

ohms.) Both terminators must reside physically within the same 

backplane. 

C.7.7 Bus Interconnecting Wiring 

The following sections give specific information about bus interconnecting 
wiring. 

C.7.7.1 Backplane Wiring 

The wiring that connects all device interface slots on the Q22-bus must 
meet the following specifications: 

• The conductors must be arranged so that each line exhibits a 
characteristic impedance of 120 ohms (measured with respect to 
the bus common return). 

• Crosstalk between any two lines must be no greater than 5%. Note 
that worst-case crosstalk is manifested by simultaneously driving all 
but one signal line and measuring the effect on the undriven line. 

• DC resistance of the signal path, as measured between the near- 
end terminator and the far-end terminator module (including all 
intervening connectors, cables, backplane wiring, and connector- 
module etch) must not exceed 20 ohms. 

• DC resistance of the common return path, as measured between the 
near-end terminator and the far-end terminator module (including 
all intervening connectors, cables, backplane wiring and connector- 
module etch) must not exceed an equivalent of 2 ohms per signal 
path. Thus, the composite signal return path dc resistance must not 
exceed 2 ohms divided by 40 bus lines, or 50 milliohms. Note that 
although this common return path is nominally at ground potential, 
the conductance must be part of the bus wiring. The specified 

low impedance return path must be provided by the bus wiring as 
distinguished from the common system or power ground path. 



Q22-bus Specification C-39 



C.7.7.2 Intrabackplane Bus Wiring 

The wiring that connects the bus connector slots within one contiguous 
backplane is part of the overall bus transmission line. Owing to 
implementation constraints, the nominal characteristic impedance of 
120 ohms may not be achievable. Distributed wiring capacitance in excess 
of the amount required to achieve the nominal 120-ohm impedance may 
not exceed 60 pF per signal line per backplane. 

C.7.7.3 Power and Ground 

Each bus interface slot has connector pins assigned for the following dc 
voltages. The maximum allowable current per pin is 1.5 A. +5 Vdc must 
be regulated to 5% with a maximum ripple of 100 mV pp. +12 Vdc must 
be regulated to 3% with a maximum ripple of 200 mV pp. 

• +5 Vdc — three pins (4.5 A maximum per bus device slot) 

• +12 Vdc — two pins (3.0 A maximum per bus device slot) 

• Ground — eight pins (shared by power return and signal return) 

NOTE 

Power is not bused between backplanes on any interconnecting 

bus cables. 

C.8 System Configurations 

Q22-bus systems can be divided into two types: 

• Systems containing one backplane 

• Systems containing multiple backplanes 

Before configuring any system, three characteristics for each module in 
the system must be identified. 

• Power consumption — +5 Vdc and +12 Vdc are the current 
requirements. 

• AC bus loading — the amount of capacitance a module presents to a 
bus signal line. AC loading is expressed in terms of ac loads, where 
one ac load equals 9.35 pF of capacitance. 

• DC bus loading — the amount of dc leakage current a module presents 
to a bus signal when the line is high (undriven). DC loading is 
expressed in terms of dc loads, where one dc load equals 210 uA 
(nominal). 



C-40 Q22-bus Specification 



Power consumption, ac loading, and dc loading specifications for each 
module are included in the Microcomputer Interfaces Handbook. 

NOTE 

The ac and dc loads and the power consumption of the processor 
module, terminator module, and backplane must be included in 
determining the total loading of a backplane. 

Rules for configuring single-backplane systems are as follows: 

• When using a processor with 220-ohm termination, the bus can 
accommodate modules that have up to 20 ac loads before additional 
termination is required (Figure C— 16). If more than 20 ac loads are 
included, the other end of the bus must be terminated with 120 ohms, 
and then up to 35 ac loads may be present. 

• With 120-ohm processor termination, up to 35 ac loads can be used 
without additional termination. If 120-ohm bus termination is added, 
up to 45 ac loads can be configured in the backplane. 

• The bus can accommodate modules up to 20 dc loads (total). 

• The bus signal lines on the backplane can be up to 35.6 cm (14 in.) 
long. 



h 



BACKPLANE WIRE 

35.6 CM (14 IN) MAXIMUM 




PROCESSOR 



TERM 



MR-6034 
MA-1072-87 



Figure C-16 Single-Backplane Configuration 



Q22-bus Specification C-41 



Rules for configuring multiple backplane systems are as follows: 

• Figure C-17 shows that up to three backplanes can make up the 
system. 

• The signal lines on each backplane can be up to 25.4 cm (10 in.) long. 

• Each backplane can accommodate modules that have up to 22 ac 
loads. Unused ac loads from one backplane may not be added to 
another backplane if the second backplane loading exceeds 22 ac 
loads. It is desirable to load backplanes equally, or with the highest 
ac loads in the first and second backplanes. 

• DC loading of all modules in all backplanes cannot exceed 20 loads. 

• Both ends of the bus must be terminated with 120 ohms. This means 
the first and last backplanes must have an impedance of 120 ohms. 
Td achieve this, each backplane can be lumped together as a single 
point. The resistive termination can be provided by a combination of 
two modules in the backplane — the processor providing 220 ohms to 
ground in parallel with an expansion paddle card providing 250 ohms 
to give the needed 120-ohm termination. 

Alternately, a processor with 120-ohm termination would need no 
additional termination on the paddle card to attain 120 ohms in the 
first box. The 120-ohm termination in the last box can be provided 
in two ways: the termination resistors may reside either on the 
expansion paddle card, or on a bus termination card (such as the 
BDV11). 

• The cable(s) connecting the first two backplanes is 61 cm (2 ft) or more 
in length. 

• The cable(s) connecting the second backplane to the third backplane 
is 122 cm (4 ft) longer or shorter than the cable(s) connecting the first 
and second backplanes. 

• The combined length of both cables cannot exceed 4.88 m (16 ft). 

• The cables used must have a characteristic impedance of 120 ohms. 



C-42 Q22-bus Specification 



PROCESSOR 



ADDITIONAL 
CABLES AND 
BACKPLANE 



h 



BACKPLANE WIRE - 
35.6 CM (14 in. ) MAX 




BACKPLANE WIRE 
25.4 CM (10 IN) MAX 



20 AC LOADS MAX 

BACKPLANE WIRE 
'25.4 CM (10 IN) MAX 



H 















) I 




















ONE 
UNIT 
LOAD 




ONE 

UNIT 

LOAD 




















CAE 


LE 


V. 








J 


CABLE 




20 AC LOADS MAX 



NOTES: 

1. TWO CABLES (MAX) 4.88 M (16 FT) (MAX) 
TOTAL LENGTH. 

2. 20 DC LOADS TOTAL (MAX). 



MR-6035 
MA- 1073-87 



Figure C-17 Multiple Backplane Configuration 



Q22-bus Specification C-43 



C.8.1 Power Supply Loading 

Total power requirements for each backplane can be determined by 
obtaining the total power requirements for each module in the backplane. 
Obtain separate totals for +5 V and +12 V power. Power requirements for 
each module are specified in the Microcomputer Interfaces Handbook. 

When distributing power in multiple backplane systems, do not attempt 
to distribute power through the Q22-bus cables. Provide separate, 
appropriate power wiring from each power supply to each backplane. 
Each power supply should be capable of asserting BPOK H and BDCOK 
H signals according to bus protocol; this is required if automatic power- 
fail/restart programs are implemented, or if specific peripherals require 
an orderly power-down halt sequence. The proper use of BPOK H and 
BDCOK H signals is strongly recommended. 

C.9 Module Contact Finger Identification 

Digital's plug-in modules all use the same contact finger (pin) 
identification system. A typical pin is shown in Figure C— 18. 



MODULE SIDE 

SLOT (ROW) IDENTIFIER IDENTIFIER 

"SLOT B" "SIDE 2" (SOLDER 

SIDE) 
PIN IDENTIFIER 
"PIN E" 



Figure C-18 Typical Pin Identification System 

The Q22-bus is based on the use of quad-height modules that plug into 
a 2-slot bus connector. Each slot contains 36 lines (18 lines on both the 
component side and the solder side of the circuit board). 

Slots, row A, and row B include a numeric identifier for the side of the 
module. The component side is designated side 1, the solder side is 
designated side 2, as shown in Figure C-19. 



C-44 Q22-bus Specification 




COMPONENT 



Figure C-19 Quad-Height Module Contact Finger identification 

Letters ranging from A through V (excluding G, I, O, and Q) identify a 
particular pin on a side of a slot. Table C— 7 lists and identifies the bus 
pins of the quad-height module. A bus pin identifier ending with a 1 
is found on the component side of the board, while a bus pin identifier 
ending with a 2 is found on the solder side of the board. 

The positioning notch between the two rows of pins mates with a 
protrusion on the connector block for correct module positioning. 



Q22-bus Specification C-45 



The dimensions for a typical Q22-bus module are represented in 
Figure C-20. 



NOTES: 

DIMENSIONS GIVEN IN INCHES 
DIMENSIONS DENOTEO BY • ARE FOB 
MAX. USEABLE CIRCUIT AREA 
UNLESS OTHERWISE SPECIFIED ALL 
DIMENSIONS ARE 1.005 in 




MAXIMUM HEIGHT OF 
SOLDERED COMPONENT 
LEADS 
2.125 TYP. 
(17 EQUAL SPACES) 



COMPONENT LIMIT 
•H U- CONDUCTIVE -.834 

NONCONDUCTIVE - 875 

SINGLE WIDTH 

■ COMPONENT LIMIT: 

~i U-CONDUCTIVE-.343in 

NONCONDUCTIVE -.375 in 



MA-1091-87 



Figure C-20 Typical Q22-bus Module Dimensions 



Table C-7 Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AA1 


BIRQ5 L 


AB1 


BIRQ6 L 


AC1 


BDAL16 L 



AD1 



BDAL17 L 



Interrupt request priority level 5. 

Interrupt request priority level 6. 

Extended address bit during addressing protocol; 
memory error data line during data transfer 
protocol. 

Extended address bit during addressing protocol; 
memory error logic enable during data transfer 
protocol. 



C-^-6 Q22-bus Specification 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AE1 



SSPARE1 
(alternate +5B) 



AF1 



SSPARE2 



AH1 



SSPARE3 
SRUN 



AJ1 


GND 


AK1 


MSPAREA 


AL1 


MSPAREB 



Special spare — not assigned or bused in 
Digital's cable or backplane assemblies. 
Available for user connection. Optionally, this 
pin can be used for +5 V battery (+5 B) back- 
up power to keep critical circuits alive during 
power failures. A jumper is required on Q22-bus 
options to open (disconnect) the +5 B circuit in 
systems that use this line as 
SSPARE1. 

Special spare — not assigned or bused in 
Digital's cable or backplane assemblies. 
Available for user interconnection. In the 
highest priority device slot, the processor can 
use this pin for a signal to indicate its run state. 

Special spare — not assigned or bused 
simultaneously in Digital's cable or backplane 
assemblies; available for user interconnection. 
An alternate SRUN signal can be connected in 
the highest priority set. 

Ground — system signal ground and dc return. 

Maintenance spare — normally connected 
together on the backplane at each option location 
(not a bused connection). 

Maintenance spare — normally connected 
together on the backplane at each option location 
(not a bused connection). 



AMI 



GND 



Ground — system signal ground and dc return. 



Q22-bus Specification C— 47 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AN1 



BDMRL 



API 



BHALTL 



AR1 



BREFL 



DMA request — a device asserts this signal 
to request bus mastership. The processor 
arbitrates bus mastership between itself and 
all DMA devices on the bus. If the processor is 
not bus master (it has completed a bus cycle and 
BSYNC L is not being asserted by the processor), 
it grants bus mastership to the requesting device 
by asserting BDMGO L. The device responds by 
negating BDMR L and asserting BSACK L. 

Processor halt — when BHALT L is asserted 
for at least 25 us, the processor services the 
halt interrupt and responds by halting normal 
program execution. External interrupts are 
ignored but memory refresh interrupts in Q22- 
bus operations are enabled if W4 on the M7264 
and M7264-YA processor modules is removed 
and DMA request/grant sequences are enabled. 
The processor executes the ODT microcode, and 
the console device operation is invoked. 

Memory refresh — asserted by a DMA device. 
This signal forces all dynamic MOS memory 
units requiring bus refresh signals to be 
activated for each BSYNC L/BDIN L bus 
transaction It is also used as a control signal 
for block mode DMA. 



CAUTION 

The user must avoid multiple DMA data 
transfers (burst or hot mode) that could 
delay refresh operation if using DMA 
refresh. Complete refresh cycles must 
occur once every 1.6 ms if required. 



C-48 Q22-bus Specification 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AS1 



+12 B or +5 B 



ATI 
AU1 

AVI 

BA1 

BB1 



GND 
PSPARE 1 

+5B 

BDCOK H 

BPOKH 



BC1 



BD1 



BE1 



SSPARE4 
BDAL18 L 
(22-bit only) 

SSPARE5 
BDAL19 L 
(22-bit only) 



SSPARE6 
BDAL20 L 



+12 Vdc or +5 V battery back-up power to keep 
critical circuits alive during power failures. This 
signal is not bused to BS1 in all of Digital's 
backplanes. A jumper is required on all Q22-bus 
options to open (disconnect) the backup circuit 
from the bus in systems that use this line at the 
alternate voltage. 

Ground — system signal ground and dc return. 

Spare — not assigned. Customer usage not 
recommended. Prevents damage when modules 
are inserted upside down. 

+5 V battery power — secondary +5 V power 
connection. Battery power can be used with 
certain devices. 

DC power OK — a power supply generated 
signal that is asserted when the available dc 
voltage is sufficient to sustain reliable system 
operation. 

Power OK — asserted by the power supply 70 
ms after BDCOK is negated when ac power 
drops below the value required to sustain power 
(approximately 75% of nominal). When negated 
during processor operation, a power-fail trap 
sequence is initiated. 

Special spare in the Q22-bus — not assigned. 
Bused in 22-bit cable and backplane assemblies. 
Available for user interconnection. 



CAUTION 

These pins may be used by manufacturing 

as test points in some options. 

In the Q22-bus, these bused address lines are 
address lines <21:18>. Currently not used 
during data time. 



Q22-bus Specification C-49 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin 



Signal 



Definition 



BF1 



BH1 



BJ1 



BS1 

BT1 
BUI 



SSPARE7 
BDAL21 L 

SSPARE8 
GND 



BK1 


MSPAREB 


BL1 


MSPAREB 


BM1 


GND 


BN1 


BSACKL 


BP1 


BIRQ7 L 


BR1 


BEVNTL 



+12 B 

GND 

PSPARE2 



BV1 
AA2 



+5 
+5 



In the Q22-bus, these bused address lines are 
address lines <21:18>. Currently not used 
during data time. 

Special spare — not assigned or bused in 
Digital's cable and backplane assemblies. 
Available for user interconnection. 

Ground — system signal ground and dc return. 

Maintenance spare — normally connected 
together on the backplane at each option location 
(not a bused connection). 

Ground — system signal ground and dc return. 

This signal is asserted by a DMA device in 
response to the processor's BDMGO L signal, 
indicating that the DMA device is bus master. 

Interrupt request priority level 7. 

External event interrupt request — when 
asserted, the processor responds by entering 
a service routine through vector address 1008. A 
typical use of this signal is as a line time clock 
(LTC) interrupt. 

+12 Vdc battery back-up power (not bused to 
AS1 in all of Digital's backplanes). 

Ground — system signal ground and dc return. 

Power spare 2 — not assigned a function and not 
recommended for use. If a module is using 
-12 V (on pin AB2), and, if the module is 
accidentally inserted upside down in the 
backplane, -12 Vdc appears on pin BUI. 

+5 V power — normal +5 Vdc system power. 

+5 V power — normal +5 Vdc system power. 



C— 50 Q22-bus Specification 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AB2 



-12 



AC2 
AD2 
AE2 



GND 

+12 
BDOUT L 



AF2 



BRPLY L 



AH2 



BDINL 



-12 V power 12 Vdc power for (optional) 

devices requiring this voltage. Each Q22- 
bus module that requires negative voltages 
contains an inverter circuit that generates the 
required voltage(s). Therefore, -12 V power is 
not required with Digital's options. 

Ground — system signal ground and dc return. 

+12 V power 1-12 Vdc system power. 

Data output — when asserted, BDOUT implies 
that valid data is available on BDAL<0:15> L 
and that an output transfer, with respect to the 
bus master device, is taking place. BDOUT L is 
deskewed with respect to data on the bus. The 
slave device responding to the BDOUT L signal 
must assert BRPLY L to complete the transfer. 

Reply — BRPLY L is asserted in response 
to BDIN L or BDOUT L and during IAK 
transactions. It is generated by a slave device to 
indicate that it has placed its data on the BDAL 
bus or that it has accepted output data from the 
bus. 

Data input — BDIN L is used for two types of 
bus operations. 

• When asserted during BSYNC L time, BDIN 
L implies an input transfer with respect 

to the current bus master, and requires a 
response (BRPLY L). BDIN L is asserted 
when the master device is ready to accept 
data from the slave device. 

• When asserted without BSYNC L, it 
indicates that an interrupt operation is 
occurring. The master device must deskew 
input data from BRPLY L. 



Q22-bus Specification C-51 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AJ2 BSYNC L Synchronize — BSYNC L is asserted by the bus 

master device to indicate that it has placed an 
address on BDAL<0:17> L. The transfer is in 
process until BSYNC L is negated. 

AK2 BWTBT L Write/byte — BWTBT L is used in two ways to 

control a bus cycle. 

• It is asserted at the leading edge of BSYNC 
L to indicate that an output sequence (DATO 
or DATOB), rather than an input sequence, 
is to follow. 

• It is asserted during BDOUT L, in a DATOB 
bus cycle, for byte addressing. 



AL2 



BIRQ4 L 



AM2 

AN2 



BIAKIL 
BIAKOL 



Interrupt request priority level 4 — a level 4 
device asserts this signal when its interrupt 
enable and interrupt request flip-flops are set. If 
the PS word bit 7 is 0, the processor responds by 
acknowledging the request by asserting BDIN L 
and BIAKO L. 

Interrupt acknowledge — in accordance with 
interrupt protocol, the processor asserts BIAKO 
L to acknowledge receipt of an interrupt. The 
bus transmits this to BIAKI L of the device 
electrically closest to the processor. This device 
accepts the interrupt acknowledge under two 
conditions. 

• The device requested the bus by asserting 
BIRQn L (where n= 4, 5, 6 or 7) 

• The device has the highest priority interrupt 
request on the bus at that time. 



C— 52 Q22-bus Specification 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AP2 



BBS7L 



AR2 
AS2 



BDMGI L 
BDMGOL 



AT2 



BINIT L 



If these conditions are not met, the device 
asserts BIAKO L to the next device on the bus. 
This process continues in a daisy chain fashion 
until the device with the highest interrupt 
priority receives the interrupt acknowledge 
signal. 

Bank 7 select — the bus master asserts this 
signal to reference the I/O page (including 
that part of the page reserved for nonexistent 
memory). The address in BDAL<0:12> L when 
BBS7 L is asserted is the address within the I/O 
page. 

Direct memory access grant — the bus arbitrator 
asserts this signal to grant bus mastership to a 
requesting device, according to bus mastership 
protocol. The signal is passed in a daisy-chain 
from the arbitrator (as BDMGO L) through the 
bus to BDMGI L of the next priority device (the 
device electrically closest on the bus). 

This device accepts the grant only if it requested 
to be the bus master (by a BDMR L). If 
not, the device passes the grant (asserts 
BDMGO L) to the next device on the bus. This 
process continues until the requesting device 
acknowledged the grant. 

CAUTION 

DMA device transfers must not interfere 

with the memory refresh cycle. 

Initialize — this signal is used for system reset. 
All devices on the bus are to return to a known, 
initial state; that is, registers are reset to zero, 
and logic is reset to state 0. Exceptions should 
be completely documented in programming and 
engineering specifications for the device. 



Q22-bus Specification C-53 



Table C-7 (Cont.) Bus Pin Identifiers 



Bus Pin Signal 



Definition 



AU2 
AV2 



BDALOL 
BDAL1L 



BA2 
BB2 

BC2 
BD2 



+5 
-12 

GND 
+12 



BE2 


BDAL2L 


BF2 


BDAL3L 


BH2 


BDAL4L 


BJ2 


BDAL5L 


BK2 


BDAL6L 


BL2 


BDAL7L 


BM2 


BDAL8L 


BN2 


BDAL9L 


BP2 


BDAL10 L 


BR2 


BDAL11 L 


BS2 


BDAL12 L 


BT2 


BDAL13 L 


BU2 


BDAL14 L 


BV2 


BDAL15 L 



Data/address lines — these two lines are part 
of the 16-line data/address bus over which 
address and data information are communicated. 
Address information is first placed on the bus 
by the bus master device. The same device then 
either receives input data from, or outputs data 
to, the addressed slave device or memory over 
the same bus lines. 

+5 V power — normal +5 Vdc system power. 

-12 V power (voltage not supplied) 12 Vdc 

power for (optional) devices requiring this 
voltage. 

Ground — system signal ground and dc return. 

+12 V power — +12 V system power. 

Data/address lines — these 14 lines are part of 
the 16-line data/address bus. 



D 

Acronyms 



This appendix lists and defines the acronyms that are most frequently 
used in this manual. 



ACRONYM 


DEFINITION 


ACV 


Access control violation 


AIE 


Alarm interrupt enable 


ANSI 


American National Standards Institute 


AP 


Argument pointer 


ASTLVL 


Asynchronous system trap level 


BBU 


Battery back-up unit 


BCD 


Binary coded decimal 


BDR 


Boot and diagnostic register 


BM 


Byte mask 


BRS 


Baud rate select signals 


CMCTL 


CVAX memory controller chip 


CPMBX 


Console program mailbox 


CQBIC 


CVAX Q22-bus interface chip 


CRC 


Cyclic redundancy check 


CSR 


Control and status register 


CSTD 


Console storage transmit data 


CSTS 


Console storage transmit status 


DEAR 


DMA error address register 


DIP 


Dual in-line package 


DM 


Data mode 


DMA 


Direct memory access 



D-1 



D— 2 Acronyms 



ACRONYM 



DEFINITION 



DSE 

DSER 

DSSI 

EDITPC 

EIA 

EPC 

EPROM 

ERR 

ESP 

FP 

FPA 

FPU 

GPR 

ICCS 

ICR 

IORESET 

IPCR 

IPL 

IPR 

IR 

ISP 

ISR 

KSP 

LANCE 

LSI 

MAPEN 

MBRK 

MBZ 

MCESR 

MCS 

MFPR 

MMU 

MOP 

MOS 

MSER 

MSI 

MTPR 

NI 



Daylight saving enable 

DMA system error register 

Digital small storage interconnect 

EDIT packed to character string 

Electronic Industries Association 

Exception program counter 

Erasable programmable read-only memory 

Error signal 

Executive stack pointer 

Frame pointer 

Floating-point accelerator 

Floating point unit 

General purpose register 

Interval clock control and status register 

Interval count register 

I/O bus reset register 

Interprocessor communication register 

Interrupt priority level 

Internal processor register 

Index register 

Interrupt stack pointer 

Interrupt status register 

Kernel stack pointer 

Local area network controller chip 

Large scale integration 

Memory management mapping enable register 

Microprogram break register 

Must be zero 

Machine check error summary register 

Multinational character set 

Move from process register 

Memory management unit 

Maintenance operation protocol 

Metal oxide semiconductor 

Memory system error register 

Mass storage interface 

Move to process register 

Network interface 



Acronyms D— 3 



ACRONYM 



DEFINITION 



NICR 

NIRAP 

NIRDP 

NPA 

NXM 

POBR 

P1BR 

PC 

PCB 

PCBB 

PIE 

POLR 

P1LR 

PMR 

POPT 

P1PT 

PROM 

PRR 

PSL 

PSW 

PTE 

QBEAR 

RAM 

RBD 

RPB 

RR 

RXCS 

RXDB 

SAVPC 

SAVPSL 

SBR 

SCA 

SCB 

SCBB 

SCR 

SID 

SIE 

SIRR 



Next interval count register 

Network interface register address port 

Network interface register data port 

Network physical address 

Nonexistent memory 

PO base register 

PI base register 

Program counter 

Process control block 

Process control block base 

Periodic interrupt enable 

PO length register 

PI length register 

Performance monitor enable register 

PO page table 

PI page table 

Programmable read only memory 

Processor revision identifier register 

Processor status longword 

Processor status word 

Page table entry 

Q22-bus error address register 

Random-access memory 

Receive Buffer Descriptor 

Restart parameter block 

Random register 

Console receiver control/status register 

Console receiver data buffer 

Console saved PC register 

Console saved PSL register 

System base register 

System communications architecture 

System control block 

System control block base 

System configuration register 

System identification register 

System identification extension 

Software interrupt request register 



D-4 Acronyms 



ACRONYM 



DEFINITION 



SISR 

SLR 

SLU 

SP 

SPT 

SQWE 

SR 

ssc 

SSP 

TBCHK 

TBD 

TBDATA 

TBDR 

TBIA 

TBIS 

TLB 

TNV 

TODR 

TXCS 

TXDB 

UIE 

UIP 

USP 

VLSI 

VPN 

VRR 

VRT 

VMB 

XFC 

ZIP 



Software interrupt summary register 

System length register 

Serial line unit 

Stack pointer 

System page table 

Square-wave enable 

Status register 

System support chip 

Supervisor stack pointer 

Translation buffer check register 

Transmit buffer descriptor 

Translation buffer data 

Translation buffer disable register 

Translation buffer invalidate all 

Translation buffer invalidate single 

Translation lookaside buffer 

Translation not valid 

Time-of-year register 

Console transmit control/status register 

Console transmit data buffer 

Update interrupt enable 

Update in progress bit 

User stack pointer 

Very large scale integration 

Virtual page number 

Vector read register 

Valid RAM and time bit 

Virtual memory bootstrap 

Extended Function Call 

Zig-zag in-line package 



Index 



Abort, 5-14 

Accessing the Q22-bus map 

registers, 3—59 
Adding to a buffer list, 3-122 



B 



Backplane wiring, C— 38 

BadVaddr register, 3-16 

Baud rate, 3—41 

Block mode DMA, C-18 

BOOT, 6-18 

Boot and diagnostic facility, 3—49 

Boot and diagnostic register, 3—49 

Boot devices, 4—15, 6-58 

Boot flags, 6-60 

Bootstrap 

conditions, 4-11 
Bootstrapping, 6-58 
Break response, 3-41 
Buffer management, 3—95 
Bus cycle protocol, C-7 
Bus drivers, C-36 
Bus interconnecting wiring, C-38 
Bus receivers, C-36 
Bus termination, C— 37 



Cache isolation, 3—23 
Cache line format, 3-23 
Cache memory, 1—5, 3-23 



Cache organization, 3—23 
Cache swapping, 3—23 
Call-back entry points, 6-82 
Cause register, 3-12 
CDAL bus to Q22-bus address 

translation, 3—62 
Clock functions, 1-8 
CMCTL registers, 6-79 
Collision detect routine, 3—114 
Command address specifiers, 6-14 
! - Comment, 6-54 
CONFIGURE, 6-20 
Configuring the KN210, 2-3 
Configuring the Q22-bus map, 3-64 
Console command keywords, 6-12 
Console command qualifiers, 6—14 
Console commands, 6—18 
Console command syntax, 6-12 
Console control characters, 6-10 
Console error messages, 6—89 
Console interrupt specifications, 

3-42 
Console program mailbox, 6-85 
Console receiver control/status 

register, 3—37 
Console receiver data buffer, 3-37 
Console registers, 3-36 
Console Berial line, 3-36 
Console service, 6-9 
Console transmitter control/status 

register, 3-39 
Console transmitter data buffer, 

3-^0 
Contents of main memory, 6-79 



Index 1 



2 Index 



Context register, 3-16 
Continue, 4—20 
CONTINUE, 6-22 
Control functions, C— 34 
Coprocessor 0, 3—6 
Coprocessor 1, 3—6 
Coprocessors, 3—6 
CVAX initial power-up test, 4—2 
CVAX Physical address space map, 

B-4 
CVAX references, 5-28 



D, 4-21 

Data-stream read references, 5-29 

Data transfer bus cycles, C-6 

Data types, 5-8 

DATBI bus cycle, C-23 

DATBO bus cycle, C-24 

DEPOSIT, 6-22 

Device addressing, C-7 

Device dependent bootstrap 

procedures, 6-66 
Device priority, C-28 
Diagnostic and test registers, 3-139 
Diagnostic interdependencies, 6-74 
Diagnostic LED register, 3—51 
Diagnostic processor, 1—5, 5—1 
Diagnostic processor hardware 

detected errors, 5—24 
Diagnostics, 4-23, 6-71 
Direct memory access, C— 17 
Disk and tape bootstrap procedure, 

6-66 
DMA error address register, 3-69 
DMA guidelines, C-26 
DMA protocol, C-17 
DMA system error register, 3-66 
DSSIbus, 3-117 
Dump, 4-21 



E, 4-21 

Electrical specifications, A— 1 

EntryHi and EntryLo registers, 3-9 

Environmental specifications, A— 2 

Environment variables, 4—19 

Error handling, 3-70 

Error messages, 6-87 

Ethernet, 3-72 

EXAMINE, 6-24 

Exception program counter, 3-15 

Exceptions, 5-13 

Exceptions and interrupts, 5-11 

EXIT, 6-27 

External halts, 6-4 

External IPRs, B-6 



Fault, 5-14 
Fill, 4-21 
FIND, 6-28 
Firmware, 1-8 

Floating-point accelerator, 3—22 
Floating-Point accelerator, 1-5 
FPA instructions, 3-22 
Function switch, 4—3 



General exception vector, 3-21 
General purpose registers, 5-1 
Global Q22-bus address Bpace map, 

B-7 
Go, 4-21 



H 



H3602-SA CPU cover panel, 2-11 

Halt, C-34 

HALT, 6-29 

Halt code messages, 6-88 

Halt dispatch, 6-3 

Halt entry, 6-2 



Index 3 



Halt entry, exit and dispatch, 6-2 

Halt exit, 6-3 

Halt protected space, 6-80 

Hardware halt procedure, 5—25 

Help, 4-22 

HELP, 6-29 



Lexical conventions, 4—18 
List pointer registers, 3—138 
Load definition, C— 35 
Locating a console device, 6-5 
Locating the RPB, 6-76 
Look-for-work routine, 3—111 



I 



Index register, 3—11 
Information saved on a machine 

check, 5-16 
Init, 4-22 
Initialization, C— 34 
Initialization routine, 3—110 
INITIALIZE, 6-31 
Initial power-up test, 6-5 
Initiator operation, 3—121 
Instruction set, 5—8 
Instruction- stream read references, 

5-28 
Internal processor registers, 5—4 
Interprocessor communication 

register, 3—62 
Interprocessor interaction, 4—8 
Interrupt errors, 5-17 
Interrupt protocol, C-28 
Interrupts, 5-11, C-27 
Interrupt status register, 3-17 
Interval timer, 3—44 
Intrabackplane bus wiring, C— 39 



Kernel mode, 3-9 
KN2 10 Connectors, 2-4 
KN210 Firmware, 4-1 



LANCE chip, 3-75 
LANCE operation, 3-109 
LANCE programming notes, 3-114 
LED codes, 6-9 



M 



Machine state on power-up, 6-77 
Main memory addressing, 3—27 
Main memory behavior on writes, 

3-28 
Main memory control and diagnostic 

status register, 3—32 
Main memory error detection and 

correction, 3—34 
Main memory error status register, 

3-28 
Main memory layout and state, 

6-77 
Main memory organization, 3—27 
Main memory system, 3—24 
Maint, 4-22 
Maintenance mode EPROM layout, 

6-80 
Maintenance mode firmware, 6-1 
Maintenance power-up operation, 

4-10 
Mass storage interface, 3-117 
Mass storage interface command 

block, 3-124 
Memory controller, 1—5 
Memory management, 5-9 
Memory management control 

registers, 5—10 
Memory management errors, 5—17 
Microcode errors, 5-18 
Mode switch set to "Normal", 6-8 
Mode switch set to "Query", 6-7 
Mode switch set to "Test", 6-6 
Module contact finger identification, 

C--43 
MOVE, 6-33 



4 Index 



MS650-AA Memory modules, 1—6 
MS650-BA Memory modules, 1-5 
MSI clock control register, 3-145 
MSI command block word 0, 3-124 
MSI command block word 1, 3-125 
MSI command block word 2, 3-127 
MSI command block words 3-5, 

3-128 
MSI control/status register, 3-128 
MSI diagnostic control register, 

3-140 
MSI diagnostic register 0, 3—141 
MSI diagnostic register 1, 3—142 
MSI diagnostic register 2, 3—144 
MSI DSSI connection register, 

3-132 
MSI DSSI control register, 3-130 
MSI DSSI timeout register, 3-136 
MSI ID register, 3-135 
MSI initiator list pointer register, 

3-139 
MSI internal state registers, 3-146 
MSI link word 0, 3-121 
MSI link word 1, 3-122 
MSI target list pointer register, 

3-138 



N 



Network bootstrap procedure, 6-68 

Network interface, 3—72 

Network interface control and status 

register, 3—78 
Network interface control and status 

register 1, 3—84 
Network interface control and status 

register 2, 3-84 
Network interface control and status 

register 3, 3—85 
Network interface initialization 

block word 0, 3-87 
Network interface initialization 

block words 10,11, 3-94 



Network interface initialization 

block words 1-3, 3-90 
Network interface initialization 

block words 4-7, 3-91 
Network interface receive descriptor 

ring, 3-96 
Network interface register address 

port, 3-77 
Network interface register data port, 

3-78 
Network interface transmit 

descriptor ring, 3-103 
Network listening, 6-69 
NEXT, 6-35 

NI initialization block, 3—86 
NI initialization block words 8,9, 

3-92 
NISAROM, 3-74 
Nonoperating conditions greater 

than 60 days, A-3 
Nonoperating conditions less than 

60 days, A-2 



120-Ohm Q22-bus, C-35 
Operating conditions, A— 2 
Operating system restart, 6-75 
Operating systems, 4—2 
Operation switch, 4—3 



PFN bitmap, 6-78 

Physical specifications, A-l 

Power status, C— 34 

Power supply loading, C— 43 

Power-up, 6-5 

Preparing for the bootstrap, 6-62 

Primary bootstrap, VMB, 6-63 

Printenv, 4-22 

Processor revision identifier register, 

3-17 
Processor state, 5—1 



Index 5 



Processor status longword, 5-2 
Programmable timers, 3-45 
PROM bootstrap procedure, 6-67 
Public data structures, 6-85 
Public data structures and entry 
points, 6-80 



Q22-bus electrical characteristics, 

C-34 
Q22-bus error address register, 

3-69 
Q22-bus four-level interrupt 

configurations, C-32 
Q22-bus interface, 1-7, 3-55 
Q22-bus interrupt handling, 3-63 
Q22-bus map base address register, 

3-64 
Q22-bus map cache, 3-60 
Q22-bus map registers, 3-58 
Q22-bus signal assignments, C— 3 
Q22-bus to main memory address 

translation, 3—56 



R3000 console command language, 

4-17 
R3000 general purpose registers, 

3-2 
R3000 instruction set types, 3-3 
R3000 interval timer register, 3—42 
R3000 memory management, 3-6 
R3000 physical address space map, 

B-l 
R3000 RISC processor, 1-4 
R3000 sys_type environment 

variable, 4-10 
Random register, 3-11 
Read errors, 5—18 
Receive buffer descriptor n word 0, 

3-98 



Receive buffer descriptor n word 1, 

3-99 
Receive buffer descriptor n word 2, 

3-100 
Receive buffer descriptor n word 3, 

3-101 
Receive buffer descriptors, 3-97 
Receive buffers, 3—102 
Receive DMA routine, 3-112 
Receive poll routine, 3—111 
Receive routine, 3-111 
References to processor registers and 

memory, 6-17 
REPEAT, 6-36 
Reserved main memory, 6-78 
Reset exception vector, 3-21 
Restoring processor state, 6-3 
RISC processor, 3—1 
ROM memory, 3-52 



Saving processor state, 6-2 
Scatter/gather map, 6-79 
SEARCH, 6-37 
Select processor register operation, 

4-9 
SET, 6-40 
Setenv, 4-22 
SHOW, 6-44 
SIE, 4-10 

Signal level specifications, C-35 
START, 6-48 
Status register, 3—15 
Switch routine, 3-110 
System configuration register, 3-65 
System configurations, C— 39 
System control block, 5-21 
System identification, 5—27 
System support functions, 1-7 



Target operation, 3-119 



6 Index 



TEST, 6-48 
Time-of-year clock, 3—43 
Time-of-year clock and timers, 3-42 
Timer control registers, 3—45 
Timer interrupt vector registers, 

3-48 
Timer interval registers, 3—47 
Timer next interval registers, 3-48 
Translation buffer, 5-9 
Transmit buffer descriptor n word 0, 

3-104 
Transmit buffer descriptor n word 1, 

3-105 
Transmit buffer descriptor n word 2, 

3-106 
Transmit buffer descriptor n word 3, 

3-107 
Transmit buffer descriptors, 3-104 
Transmit buffers, 3-109 
Transmit data segment links, 3-121 
Transmit DMA routine, 3-113 
Transmit poll routine, 3-112 



Transmit routine, 3-113 
Trap, 5-13 

u 

UNJAM, 6-52 
Unsetenv, 4-22 
User mode, 3—9 

V 

Vector read registers, 3—18 
VMB error messages, 6-91 

w 

Write errors, 5-19 
Write references, 5—29 



X - binary load and unload, 6-52 



KN210 CPU Module Set 

Technical Manual 

READER'S COMMENTS EK-KN210-TM-001 

Your comments and suggestions will help us in our efforts to improve the quality of our publications. 



1. How did you use this manual? (Circle your response.) 



(a) Installation 

(b) Operation/use 



(c) Maintenance 

(d) Programming 



(e) Training 

(f) Other (Please specify.) 



2. Did the manual meet your needs? Yes D No D Why? 



Unacceptable 



3. Please rate the manual on the following categories. (Circle your response.) 

Excellent Good Fair Poor 

Accuracy 5 4 3 2 

Clarity 5 4 3 2 

Completeness 5 4 3 2 

Table of Contents, Index 5 4 3 2 

Illustrations, examples 5 4 3 2 

Overall ease of use 5 4 3 2 



4. What things did you like most about this manual? . 



5. What things did you like least about this manual? 



6. Please list and describe any errors you found in the manual. 
Page Description/Location of Error 



Name . 
Street . 
City 



Job Title. 



State/Country 



Postal (ZIP) Code 



Company 

Department 

Telephone Number. 
Date 



THANK YOU FOR YOUR COMMENTS AND SUGGESTIONS. 

Please do not use this form to order manuals. Contact your representative at Digital Equipment Corporation 
or (in the USA) call our DECdirect™ department at this toll-free number: 800-258-1710. 

81 1989 by Digital Equipment Corporation myo 



FOLD HERE AND TAPE. DO NOT STAPLE. 




BUSINESS REPLY MAIL 

FIRST CLASS PERMIT NO. 33 MAYNARD, MA 